{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,7]],"date-time":"2026-09-07T16:09:25Z","timestamp":1788797365108,"version":"build-2803163510"},"reference-count":40,"publisher":"Termedia Sp. z.o.o.","license":[{"start":{"date-parts":[[2025,5,12]],"date-time":"2025-05-12T00:00:00Z","timestamp":1747008000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2025,5,12]],"date-time":"2025-05-12T00:00:00Z","timestamp":1747008000000},"content-version":"am","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2025,5,12]],"date-time":"2025-05-12T00:00:00Z","timestamp":1747008000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Human Kinetics"],"abstract":"<jats:p>Wearable technology for running analysis is growing in both sports science research and applied fields. This study examined the reliability of some spatiotemporal and kinetic variables estimated from an inertial measurement unit (IMU) fastened over the lumbar spine. Eighteen recreational endurance runners performed two maximal incremental treadmill running tests during a 7\u201310  day period under standard conditions. Contact time (CT), stride time (ST), stride length (SL), stride frequency (SF), as well as anteroposterior (AP) impulses and vertical (VT) peak brake data were analysed at 9, 15 and 21 km\u00b7h\u22121. Test-retest reliability was measured as the intraclass correlation coefficient (ICC), the coefficient of variation (CV) and minimal detectable change (MDC). No significant differences between tests were observed (p &gt; 0.05; effect size (ES) &lt; 0.28; trivial to small). Reliability increased from 9 to 21 km\u00b7h\u22121 (ICC from 0.88 to 0.93; ES = 1.0; moderate) and was higher in spatiotemporal (CV &lt; 2.3%) than kinetic variables (CV &lt; 6.8%). This study adds novel data regarding the reliability of the MTw IMU. The results  reported in this study enable researchers to determine whether the changes in IMU-derived data are outside of the measurement error following training and rehabilitation settings.<\/jats:p>","DOI":"10.5114\/jhk\/195895","type":"journal-article","created":{"date-parts":[[2025,5,12]],"date-time":"2025-05-12T06:43:02Z","timestamp":1747032182000},"page":"65-76","source":"Crossref","is-referenced-by-count":3,"title":["Reliability of inertial measurement unit-based spatiotemporal and kinetic variables in endurance runners during treadmill running"],"prefix":"10.5114","volume":"97","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7939-9485","authenticated-orcid":true,"given":"Unai","family":"Miqueleiz","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9029-0886","authenticated-orcid":false,"given":"Roberto","family":"Aguado-Jimenez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pablo","family":"Lecumberri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8553-8154","authenticated-orcid":true,"given":"Ibai","family":"Garcia-Tabar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Esteban","family":"M. Gorostiaga","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"3061","published-online":{"date-parts":[[2025,5,12]]},"reference":[{"key":"ref-1430285","doi-asserted-by":"crossref","unstructured":"Alcantara, R. S., Day, E. M., Hahn, M. E., & Grabowski, A. M. (2021). Sacral acceleration can predict whole-body kinetics and stride kinematics across running speeds.\u00a0PeerJ,\u00a09, e11199.","DOI":"10.7717\/peerj.11199"},{"key":"ref-1430286","doi-asserted-by":"crossref","unstructured":"Bredeweg, S. W., Buist, I., & Kluitenberg, B. (2013). Differences in kinetic asymmetry between injured and noninjured novice runners: a prospective cohort study.\u00a0Gait & Posture,\u00a038(4), 847\u2013852.","DOI":"10.1016\/j.gaitpost.2013.04.014"},{"key":"ref-1430287","unstructured":"Buchheit, M., Gray, A., & Morin, J. B. (2015). Assessing stride variables and vertical stiffness with GPS-embedded accelerometers: preliminary insights for the monitoring of neuromuscular fatigue on the field.\u00a0Journal of Sports Science & Medicine,\u00a014(4), 698."},{"key":"ref-1430288","doi-asserted-by":"crossref","unstructured":"Chew, D. K., Ngoh, K. J. H., Gouwanda, D., & Gopalai, A. A. (2018). Estimating running spatial and temporal parameters using an inertial sensor.\u00a0Sports Engineering,\u00a021, 115\u2013122.","DOI":"10.1007\/s12283-017-0255-9"},{"key":"ref-1430289","doi-asserted-by":"crossref","unstructured":"Eggers, T. M., Massard, T. I., Clothier, P. J., & Lovell, R. (2018). Measuring vertical stiffness in sport with accelerometers: exercise caution!.\u00a0Journal of Strength & Conditioning Research,\u00a032(7), 1919\u20131922.","DOI":"10.1519\/JSC.0000000000002318"},{"key":"ref-1430290","doi-asserted-by":"crossref","unstructured":"Fadillioglu, C., Stetter, B. J., Ringhof, S., Krafft, F. C., Sell, S., & Stein, T. (2020). Automated gait event detection for a variety of locomotion tasks using a novel gyroscope-based algorithm.\u00a0Gait & Posture,\u00a081, 102\u2013108.","DOI":"10.1016\/j.gaitpost.2020.06.019"},{"key":"ref-1430291","doi-asserted-by":"crossref","unstructured":"Garcia-Pinillos, F., Latorre-Roman, P. A., Soto-Hermoso, V. M., Parraga-Montilla, J. A., Pantoja-Vallejo, A., Ramirez-Campillo, R., & Roche-Seruendo, L. E. (2019). Agreement between the spatiotemporal gait parameters from two different wearable devices and high-speed video analysis.\u00a0PLoS One,\u00a014(9), e0222872.","DOI":"10.1371\/journal.pone.0222872"},{"key":"ref-1430292","doi-asserted-by":"crossref","unstructured":"Garcia-Pinillos, F., Roche-Seruendo, L. E., Marcen-Cinca, N., Marco-Contreras, L. A., & Latorre-Roman, P. A. (2021). Absolute reliability and concurrent validity of the Stryd system for the assessment of running stride kinematics at different velocities.\u00a0Journal of Strength & Conditioning Research,\u00a035(1), 78\u201384.","DOI":"10.1519\/JSC.0000000000002595"},{"key":"ref-1430293","doi-asserted-by":"crossref","unstructured":"Giandolini, M., Arnal, P. J., Millet, G. Y., Peyrot, N., Samozino, P., Dubois, B., & Morin, J. B. (2013). Impact reduction during running: efficiency of simple acute interventions in recreational runners.\u00a0European Journal of Applied Physiology,\u00a0113, 599\u2013609.","DOI":"10.1007\/s00421-012-2465-y"},{"key":"ref-1430294","doi-asserted-by":"crossref","unstructured":"Gindre, C., Lussiana, T., Hebert-Losier, K., & Morin, J. B. (2015). Reliability and validity of the Myotest\u00ae for measuring running stride kinematics.\u00a0Journal of Sports Sciences,\u00a034(7), 664\u2013670.","DOI":"10.1080\/02640414.2015.1068436"},{"key":"ref-1430295","doi-asserted-by":"crossref","unstructured":"Girard, O., Brocherie, F., Morin, J. B., & Millet, G. P. (2017). Mechanical alterations during interval-training treadmill runs in high-level male team-sport players.\u00a0Journal of Science and Medicine in Sport,\u00a020(1), 87\u201391.","DOI":"10.1016\/j.jsams.2016.05.002"},{"key":"ref-1430296","doi-asserted-by":"crossref","unstructured":"Girard, O., Morin, J. B., Ryu, J., Read, P., & Townsend, N. (2019). Running velocity does not influence lower limb mechanical asymmetry.\u00a0Frontiers in Sports and Active Living,\u00a01, 36.","DOI":"10.3389\/fspor.2019.00036"},{"key":"ref-1430297","doi-asserted-by":"crossref","unstructured":"Gouttebarge, V., Wolfard, R., Griek, N., de Ruiter, C. J., Boschman, J. S., & van Die\u00ebn, J. H. (2015). Reproducibility and validity of the myotest for measuring step frequency and ground contact time in recreational runners.\u00a0Journal of Human Kinetics,\u00a045(1), 19\u201326.","DOI":"10.1515\/hukin-2015-0003"},{"key":"ref-1430298","doi-asserted-by":"crossref","unstructured":"Hopkins, W., Marshall, S., Batterham, A., & Hanin, J. (2009). Progressive statistics for studies in sports medicine and exercise science.\u00a0Medicine and Science in Sports and Exercise,\u00a041(1), 3.","DOI":"10.1249\/MSS.0b013e31818cb278"},{"key":"ref-1430299","doi-asserted-by":"crossref","unstructured":"Hunter, I., McLeod, A., Valentine, D., Low, T., Ward, J., & Hager, R. (2019). Running economy, mechanics, and marathon racing shoes.\u00a0Journal of Sports Sciences,\u00a037(20), 2367\u20132373.","DOI":"10.1080\/02640414.2019.1633837"},{"key":"ref-1430300","doi-asserted-by":"crossref","unstructured":"Hunter, J. P., Marshall, R. N., & McNair, P. J. (2005). Relationships between ground reaction force impulse and kinematics of sprint-running acceleration.\u00a0Journal of Applied Biomechanics,\u00a021(1), 31\u201343.","DOI":"10.1123\/jab.21.1.31"},{"key":"ref-1430301","doi-asserted-by":"crossref","unstructured":"Kawamori, N., Nosaka, K., & Newton, R. U. (2013). Relationships between ground reaction impulse and sprint acceleration performance in team sport athletes.\u00a0 Journal of Strength & Conditioning Research,\u00a027(3), 568\u2013573.","DOI":"10.1519\/JSC.0b013e318257805a"},{"key":"ref-1430302","doi-asserted-by":"crossref","unstructured":"Kluitenberg, B., Bredeweg, S. W., Zijlstra, S., Zijlstra, W., & Buist, I. (2012). Comparison of vertical ground reaction forces during overground and treadmill running. A validation study.\u00a0BMC Musculoskeletal Disorders,\u00a013(1), 1\u20138.","DOI":"10.1186\/1471-2474-13-235"},{"key":"ref-1430303","doi-asserted-by":"crossref","unstructured":"Koo, T. K., & Li, M. Y. (2016). A guideline of selecting and reporting intraclass correlation coefficients for reliability research.\u00a0Journal of Chiropractic Medicine,\u00a015(2), 155\u2013163.","DOI":"10.1016\/j.jcm.2016.02.012"},{"key":"ref-1430304","doi-asserted-by":"crossref","unstructured":"Mercer, J. A., Vance, J., Hreljac, A., & Hamill, J. (2002). Relationship between shock attenuation and stride length during running at different velocities.\u00a0European Journal of Applied Physiology,\u00a087, 403\u2013408.","DOI":"10.1007\/s00421-002-0646-9"},{"key":"ref-1430305","doi-asserted-by":"crossref","unstructured":"Mero, A., & Komi, P. V. (1986). Force-, EMG-, and elasticity-velocity relationships at submaximal, maximal and supramaximal running speeds in sprinters.\u00a0European Journal of Applied Physiology and Occupational Physiology,\u00a055, 553\u2013561.","DOI":"10.1007\/BF00421652"},{"key":"ref-1430306","doi-asserted-by":"crossref","unstructured":"Mo, S., & Chow, D. H. (2018). Accuracy of three methods in gait event detection during overground running.\u00a0Gait & posture,\u00a059, 93\u201398.","DOI":"10.1016\/j.gaitpost.2017.10.009"},{"key":"ref-1430307","doi-asserted-by":"crossref","unstructured":"Moon, Y., McGinnis, R. S., Seagers, K., Motl, R. W., Sheth, N., Wright Jr, J. A., Ghaffari, R., & Sosnoff, J. J. (2017). Monitoring gait in multiple sclerosis with novel wearable motion sensors.\u00a0PloS One,\u00a012(2), e0171346.","DOI":"10.1371\/journal.pone.0171346"},{"key":"ref-1430308","doi-asserted-by":"crossref","unstructured":"Morin, J. B., Slawinski, J., Dorel, S., Couturier, A., Samozino, P., Brughelli, M., & Rabita, G. (2015). Acceleration capability in elite sprinters and ground impulse: push more, brake less?\u00a0Journal of Biomechanics,\u00a048(12), 3149\u20133154.","DOI":"10.1016\/j.jbiomech.2015.07.009"},{"key":"ref-1430309","doi-asserted-by":"crossref","unstructured":"Morin, J. B., Tomazin, K., Samozino, P., Edouard, P., & Millet, G. Y. (2012). High-intensity sprint fatigue does not alter constant-submaximal velocity running mechanics and spring-mass behavior.\u00a0European Journal of Applied Physiology,\u00a0112, 1419\u20131428.","DOI":"10.1007\/s00421-011-2103-0"},{"key":"ref-1430310","doi-asserted-by":"crossref","unstructured":"Munro, C. F., Miller, D. I., & Fuglevand, A. J. (1987). Ground reaction forces in running: a reexamination.\u00a0Journal of Biomechanics,\u00a020(2), 147\u2013155.","DOI":"10.1016\/0021-9290(87)90306-X"},{"key":"ref-1430311","doi-asserted-by":"crossref","unstructured":"Nedergaard, N. J., Verheul, J., Drust, B., Etchells, T., Lisboa, P., Robinson, M. A., & Vanrenterghem, J. (2018). The feasibility of predicting ground reaction forces during running from a trunk accelerometry driven mass-spring-damper model.\u00a0PeerJ,\u00a06, e6105.","DOI":"10.7717\/peerj.6105"},{"key":"ref-1430312","doi-asserted-by":"crossref","unstructured":"Raper, D. P., Witchalls, J., Philips, E. J., Knight, E., Drew, M. K., & Waddington, G. (2018). Use of a tibial accelerometer to measure ground reaction force in running: A reliability and validity comparison with force plates.\u00a0Journal of Science and Medicine in Sport,\u00a021(1), 84\u201388.","DOI":"10.1016\/j.jsams.2017.06.010"},{"key":"ref-1430313","doi-asserted-by":"crossref","unstructured":"Reenalda, J., Maartens, E., Buurke, J. H., & Gruber, A. H. (2019). Kinematics and shock attenuation during a prolonged run on the athletic track as measured with inertial magnetic measurement units.\u00a0Gait & Posture,\u00a068, 155\u2013160.","DOI":"10.1016\/j.gaitpost.2018.11.020"},{"key":"ref-1430314","doi-asserted-by":"crossref","unstructured":"Scrimgeour, A. G., Noakes, T. D., Adams, B., & Myburgh, K. (1986). The influence of weekly training distance on fractional utilization of maximum aerobic capacity in marathon and ultramarathon runners.\u00a0European Journal of Applied Physiology and Occupational Physiology,\u00a055(2), 202\u2013209.","DOI":"10.1007\/BF00715006"},{"key":"ref-1430315","doi-asserted-by":"crossref","unstructured":"Seeley, M. K., Evans-Pickett, A., Collins, G. Q., Tracy, J. B., Tuttle, N. J., Rosquist, P. G., Merrell, A., Christensen, W.F., Fullwood, D.T., & Bowden, A. E. (2020). Predicting vertical ground reaction force during running using novel piezoresponsive sensors and accelerometry.\u00a0Journal of Sports Sciences,\u00a038(16), 1844\u20131858.","DOI":"10.1080\/02640414.2020.1757361"},{"key":"ref-1430316","doi-asserted-by":"crossref","unstructured":"Setuain, I., Martinikorena, J., Gonzalez-Izal, M., Martinez-Ramirez, A., G\u00f3mez, M., Alfaro-Adrian, J., & Izquierdo, M. (2016). Vertical jumping biomechanical evaluation through the use of an inertial sensor-based technology.\u00a0Journal of Sports Sciences,\u00a034(9), 843\u2013851.","DOI":"10.1080\/02640414.2015.1075057"},{"key":"ref-1430317","doi-asserted-by":"crossref","unstructured":"Sinclair, J., Hobbs, S. J., Protheroe, L., Edmundson, C. J., & Greenhalgh, A. (2013). Determination of gait events using an externally mounted shank accelerometer.\u00a0Journal of Applied Biomechanics,\u00a029(1), 118\u2013122.","DOI":"10.1123\/jab.29.1.118"},{"key":"ref-1430318","doi-asserted-by":"crossref","unstructured":"Tan, H., Wilson, A. M., & Lowe, J. (2008). Measurement of stride parameters using a wearable GPS and inertial measurement unit.\u00a0Journal of Biomechanics,\u00a041(7), 1398\u20131406.","DOI":"10.1016\/j.jbiomech.2008.02.021"},{"key":"ref-1430319","doi-asserted-by":"crossref","unstructured":"Tura, A., Raggi, M., Rocchi, L., Cutti, A. G., & Chiari, L. (2010). Gait symmetry and regularity in transfemoral amputees assessed by trunk accelerations.\u00a0Journal of Neuroengineering and Rehabilitation,\u00a07, 1\u201310.","DOI":"10.1186\/1743-0003-7-4"},{"key":"ref-1430320","doi-asserted-by":"crossref","unstructured":"Van Alsenoy, K., Thomson, A., & Burnett, A. (2019). Reliability and validity of the Zebris FDM-THQ instrumented treadmill during running trials.\u00a0Sports Biomechanics,\u00a018(5), 501\u2013514.","DOI":"10.1080\/14763141.2018.1452966"},{"key":"ref-1430321","doi-asserted-by":"crossref","unstructured":"Van Hooren, B., Goudsmit, J., Restrepo, J., & Vos, S. (2020). Real-time feedback by wearables in running: Current approaches, challenges and suggestions for improvements.\u00a0Journal of Sports Sciences,\u00a038(2), 214\u2013230.","DOI":"10.1080\/02640414.2019.1690960"},{"key":"ref-1430322","doi-asserted-by":"crossref","unstructured":"Watari, R., Hettinga, B., Osis, S., & Ferber, R. (2016). Validation of a torso-mounted accelerometer for measures of vertical oscillation and ground contact time during treadmill running.\u00a0Journal of Applied Biomechanics,\u00a032(3), 306\u2013310.","DOI":"10.1123\/jab.2015-0200"},{"key":"ref-1430323","doi-asserted-by":"crossref","unstructured":"Weart, A. N., Miller, E. M., Freisinger, G. M., Johnson, M. R., & Goss, D. L. (2020). Agreement between the OptoGait and instrumented treadmill system for the quantification of spatiotemporal treadmill running parameters.\u00a0Frontiers in Sports and Active Living,\u00a02, 571385.","DOI":"10.3389\/fspor.2020.571385"},{"key":"ref-1430324","doi-asserted-by":"crossref","unstructured":"Winter, S., Gordon, S., Brice, S., & Lindsay, D. (2018). Centre of mass acceleration-derived variables detects differences between runners of different abilities and fatigue-related changes during a long distance over ground run.\u00a0Journal of Physical Fitness, Medicine & Treatment in Sports,\u00a04(2), 1\u201312.","DOI":"10.19080\/JPFMTS.2018.04.555632"}],"container-title":["Journal of Human Kinetics"],"original-title":[],"link":[{"URL":"https:\/\/jhk.termedia.pl\/pdf-195895-124926","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/jhk.termedia.pl\/pdf-195895-124926","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,12]],"date-time":"2025-05-12T06:43:16Z","timestamp":1747032196000},"score":1,"resource":{"primary":{"URL":"https:\/\/jhk.termedia.pl\/Reliability-of-inertial-measurement-unit-based-spatiotemporal-and-kinetic-variables,195895,0,2.html"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,12]]},"references-count":40,"alternative-id":["195895"],"URL":"https:\/\/doi.org\/10.5114\/jhk\/195895","relation":{},"ISSN":["1640-5544","1899-7562"],"issn-type":[{"value":"1640-5544","type":"print"},{"value":"1899-7562","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,12]]}}}