{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,3]],"date-time":"2025-10-03T08:26:46Z","timestamp":1759480006661},"reference-count":47,"publisher":"Termedia Sp. z.o.o.","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pol J Radiol"],"abstract":"<jats:sec><jats:title>Purpose<\/jats:title><jats:p>The aim of the work was to share the practical experience of preclinical and clinical proton magnetic resonance spectroscopy (&lt;sup&gt;1&lt;\/sup&gt;HMRS) studies conducted using a 7-Tesla magnetic field strength scanner, taking into account the specificity of both settings in the context of translational research.<\/jats:p><\/jats:sec><jats:sec><jats:title>Material and methods<\/jats:title><jats:p>&lt;sup&gt;1&lt;\/sup&gt;HMRS volunteer studies conducted using a Discovery 950 GE 7T scanner, were carried out with PRESS sequence, and a VOI measuring 2.0 \u00d7 2.0 \u00d7 2.0 cm&lt;sup&gt;3&lt;\/sup&gt; placed in the white matter at the parietal occipital lobe. Rodent spectra obtained using a 7T Bruker were measured with PRESS, with a VOI 2.0 \u00d7 2.0 \u00d7 5.5 mm3 placed over the hippocampus.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>&lt;sup&gt;1&lt;\/sup&gt;HMRS data from humans and rats show that the brain spectra obtained in the same field are characterised by a similar neurochemical structure and spectral resolution. Spectra obtained from rats demonstrate the following metabolites: NAA, Glu, Gln, Ins, Cho, Cr, PCr, Tau, GABA, Lac, NAAG, and Asp. In turn, spectra from humans allowed estimation of the following metabolites: Ala, NAA, Glu, Gln, Ins, Cho, Cr, PCr, Tau, GABA, Lac, NAAG, and Asp. Signals from Gln, Glu with chemical shift around 2.4 ppm, from Cr, PCr, and GABA at 3 ppm, and signals from Cho and Tau at approximately 3.2 ppm, can be properly separated and estimated both in humans and in rats.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>These results are promising in terms of broadening the knowledge of many neurological diseases by inducing them on animal models and then transferring this knowledge to clinical practice. In spite of this, important distinctions in the technical aspects and methodological differences of high-field &lt;sup&gt;1&lt;\/sup&gt;HMRS in both preclinical and clinical conditions should be taken into account.<\/jats:p><\/jats:sec>","DOI":"10.5114\/pjr.2019.85147","type":"journal-article","created":{"date-parts":[[2019,6,12]],"date-time":"2019-06-12T07:16:15Z","timestamp":1560323775000},"page":"190-197","source":"Crossref","is-referenced-by-count":2,"title":["General technical remarks on 1HMRS translational research in 7T"],"prefix":"10.5114","volume":"84","author":[{"given":"Katarzyna","family":"Kochalska","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Artur","family":"\u0141azorczyk","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anna","family":"Pankowska","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Katarzyna","family":"Dyndor","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paulina","family":"Kozio\u0142","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrzej","family":"St\u0119pniewski","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Radoslaw","family":"Pietura","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"3061","published-online":{"date-parts":[[2019,4,12]]},"reference":[{"key":"ref-1141192","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.neuroimage.2018.01.072","article-title":"Neuroimaging with ultra-high field MRI: Present and future","volume":"168","author":"Polimeni JR","year":"2018","unstructured":"Polimeni JR, Uluda\u011f K. (2018). Neuroimaging with ultra-high field MRI: Present and future. Neuroimage. 168: 1-6.","journal-title":"Neuroimage"},{"key":"ref-1141193","volume-title":"Clinical MR spectroscopy: Techniques and applications","author":"Barker P","year":"2010","unstructured":"Barker P. (2010). Clinical MR spectroscopy: Techniques and applications.  Cambridge University Press, Cambridge."},{"key":"ref-1141194","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1002\/jmri.25356","article-title":"Reproducibility measurement of glutathione, GABA, and glutamate: Towards in vivo neurochemical profiling of multiple sclerosis with MR spectroscopy at 7T","volume":"45","author":"Prinsen H","year":"2017","unstructured":"Prinsen H, Graaf RA de, Mason GF, et al. (2017). Reproducibility measurement of glutathione, GABA, and glutamate: Towards in vivo neurochemical profiling of multiple sclerosis with MR spectroscopy at 7T. J Magn Reson Imaging. 45: 187-198.","journal-title":"J Magn Reson Imaging"},{"key":"ref-1141195","doi-asserted-by":"crossref","first-page":"S44","DOI":"10.3174\/ajnr.A3965","article-title":"Molecular imaging for depressive disorders","volume":"35","author":"Lee TS","year":"2014","unstructured":"Lee TS, Quek SY, Krishnan KRR. (2014). Molecular imaging for depressive disorders. AJNR Am J Neuroradiol. 35: S44-S54.","journal-title":"AJNR Am J Neuroradiol"},{"key":"ref-1141196","doi-asserted-by":"crossref","first-page":"123","DOI":"10.3389\/fpsyt.2017.00123","article-title":"Ultra-High-Field Magnetic Resonance Spectroscopy in Psychiatry","volume":"8","author":"Godlewska BR","year":"2017","unstructured":"Godlewska BR, Clare S, Cowen PJ, Emir UE. (2017). Ultra-High-Field Magnetic Resonance Spectroscopy in Psychiatry. Front Psychiatry. 8: 123.","journal-title":"Front Psychiatry"},{"key":"ref-1141197","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1016\/j.jmir.2017.06.004","article-title":"Magnetic Resonance Spectroscopy and its Clinical Applications: A Review","volume":"48","author":"Faghihi R","year":"2017","unstructured":"Faghihi R, Zeinali-Rafsanjani B, Mosleh-Shirazi MA, et al. (2017). Magnetic Resonance Spectroscopy and its Clinical Applications: A Review. Journal of Medical Imaging and Radiation Sciences. 48: 233-253.","journal-title":"Journal of Medical Imaging and Radiation Sciences"},{"key":"ref-1141198","doi-asserted-by":"crossref","first-page":"1083","DOI":"10.1002\/mrm.26022","article-title":"Test-retest reproducibility of neurochemical profiles with short-echo, single-voxel MR spectroscopy at 3T and 7T","volume":"76","author":"Terpstra M","year":"2016","unstructured":"Terpstra M, Cheong I, Lyu T, et al. (2016). Test-retest reproducibility of neurochemical profiles with short-echo, single-voxel MR spectroscopy at 3T and 7T. Magn Reson Med. 76: 1083-1091.","journal-title":"Magn Reson Med"},{"key":"ref-1141199","doi-asserted-by":"crossref","DOI":"10.1007\/978-3-540-85090-8","volume-title":"High-Field MR Imaging","author":"Hennig J","year":"2012","unstructured":"Hennig J, Speck O. (2012). High-Field MR Imaging.  Springer, Berlin Heidelberg."},{"key":"ref-1141200","doi-asserted-by":"crossref","first-page":"451","DOI":"10.1002\/mrm.1213","article-title":"In vivo 1H NMR spectroscopy of the human brain at 7 T","volume":"46","author":"Tk\u00e1c I","year":"2001","unstructured":"Tk\u00e1c I, Andersen P, Adriany G, et al. (2001). In vivo 1H NMR spectroscopy of the human brain at 7 T. Magn Reson Med. 46: 451-466.","journal-title":"Magn Reson Med"},{"key":"ref-1141201","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1007\/s11910-018-0841-7","article-title":"Present and Future of Ultra- High Field MRI in Neurodegenerative Disorders","volume":"18","author":"Donatelli G","year":"2018","unstructured":"Donatelli G, Ceravolo R, Frosini D, et al. (2018). Present and Future of Ultra- High Field MRI in Neurodegenerative Disorders. Curr Neurol Neurosci Rep. 18: 31.","journal-title":"Curr Neurol Neurosci Rep"},{"key":"ref-1141202","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1016\/j.braindev.2006.10.005","article-title":"Clinical application of high and ultra high-field MRI","volume":"29","author":"Nakada T","year":"2007","unstructured":"Nakada T. (2007). Clinical application of high and ultra high-field MRI. Brain Dev. 29: 325-335.","journal-title":"Brain Dev"},{"key":"ref-1141203","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1016\/j.neuroimage.2017.07.017","article-title":"Proton and multinuclear magnetic resonance spectroscopy in the human brain at ultra-high field strength: A review","volume":"168","author":"Henning A","year":"2018","unstructured":"Henning A. (2018). Proton and multinuclear magnetic resonance spectroscopy in the human brain at ultra-high field strength: A review. Neuroimage. 168: 181-198.","journal-title":"Neuroimage"},{"key":"ref-1141204","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1016\/j.neuroimage.2017.07.007","article-title":"Imaging at ultrahigh magnetic fields: History, challenges, and solutions","volume":"168","author":"U\u011furbil K","year":"2018","unstructured":"U\u011furbil K. (2018). Imaging at ultrahigh magnetic fields: History, challenges, and solutions. Neuroimage. 168: 7-32.","journal-title":"Neuroimage"},{"key":"ref-1141205","first-page":"12","article-title":"In vivo NMR Imaging Methods and Protocols","author":"Schr\u00f6der L","year":"2011","unstructured":"Schr\u00f6der L. (2011). In vivo NMR Imaging Methods and Protocols. Humana Press. : 12-20.","journal-title":"Humana Press"},{"key":"ref-1141206","doi-asserted-by":"crossref","first-page":"1015","DOI":"10.1016\/j.biopsych.2011.07.034","article-title":"Translational magnetic resonance spectroscopy reveals excessive central glutamate levels during alcohol withdrawal in humans and rats","volume":"71","author":"Hermann D","year":"2012","unstructured":"Hermann D, Weber-Fahr W, Sartorius A, et al. (2012). Translational magnetic resonance spectroscopy reveals excessive central glutamate levels during alcohol withdrawal in humans and rats. Biol Psychiatry. 71: 1015-1021.","journal-title":"Biol Psychiatry"},{"key":"ref-1141207","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.pnmrs.2018.06.001","article-title":"Pros and cons of ultra-high-field MRI\/MRS for human application","volume":"109","author":"Ladd ME","year":"2018","unstructured":"Ladd ME, Bachert P, Meyerspeer M, et al. (2018). Pros and cons of ultra-high-field MRI\/MRS for human application. Prog Nucl Magn Reson Spectrosc. 109: 1-50.","journal-title":"Prog Nucl Magn Reson Spectrosc"},{"key":"ref-1141208","volume-title":"Handbook of magnetic resonance spectroscopy in vivo: MRS theory, practice and applications","author":"Bottomley PA","year":"2016","unstructured":"Bottomley PA, Griffiths JR. (2016). Handbook of magnetic resonance spectroscopy in vivo: MRS theory, practice and applications.  Wiley, Chichester."},{"key":"ref-1141209","doi-asserted-by":"crossref","first-page":"1339","DOI":"10.1093\/ije\/dyw235","article-title":"Quantitative in vivo neurochemical profiling in humans: where are we now?","volume":"45","author":"McKay J","year":"2016","unstructured":"McKay J, Tk\u00e1\u010d I. (2016). Quantitative in vivo neurochemical profiling in humans: where are we now?. Int J Epidemiol. 45: 1339-1350.","journal-title":"Int J Epidemiol"},{"key":"ref-1141210","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1007\/BF03166960","article-title":"Methodology of H NMR Spectroscopy of the Human Brain at Very High Magnetic Fields","volume":"29","author":"Tk\u00e1\u010d I","year":"2005","unstructured":"Tk\u00e1\u010d I, Gruetter R. (2005). Methodology of H NMR Spectroscopy of the Human Brain at Very High Magnetic Fields. Appl Magn Reson. 29: 139-157.","journal-title":"Appl Magn Reson"},{"key":"ref-1141211","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1002\/mrm.25602","article-title":"Metabolite and macromolecule T1 and T2 relaxation times in the rat brain in vivo at 17.2T","volume":"75","author":"Lopez-Kolkovsky AL","year":"2016","unstructured":"Lopez-Kolkovsky AL, M\u00e9riaux S, Boumezbeur F. (2016). Metabolite and macromolecule T1 and T2 relaxation times in the rat brain in vivo at 17.2T. Magn Reson Med. 75: 503-514.","journal-title":"Magn Reson Med"},{"key":"ref-1141212","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1515\/revneuro-2015-0010","article-title":"Magnetic resonance spectroscopy of the brain: a review of physical principles and technical methods","volume":"26","author":"Buonocore MH","year":"2015","unstructured":"Buonocore MH, Maddock RJ. (2015). Magnetic resonance spectroscopy of the brain: a review of physical principles and technical methods. Rev Neurosci. 26: 609-632.","journal-title":"Rev Neurosci"},{"key":"ref-1141213","doi-asserted-by":"crossref","first-page":"1432","DOI":"10.1002\/jmri.24689","article-title":"Numerical evaluation of image homogeneity, signal-to-noise ratio, and specific absorption rate for human brain imaging at 1.5, 3, 7, 10.5, and 14T in an 8-channel transmit\/receive array","volume":"41","author":"Cao Z","year":"2015","unstructured":"Cao Z, Park J, Cho Z-H, Collins CM. (2015). Numerical evaluation of image homogeneity, signal-to-noise ratio, and specific absorption rate for human brain imaging at 1.5, 3, 7, 10.5, and 14T in an 8-channel transmit\/receive array. J Magn Reson Imaging. 41: 1432-1439.","journal-title":"J Magn Reson Imaging"},{"key":"ref-1141214","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1006\/jmrb.1993.1056","article-title":"Absolute Quantitation of Water and Metabolites in the Human Brain. II. Metabolite Concentrations","volume":"102","author":"Kreis R","year":"1993","unstructured":"Kreis R, Ernst T, Ross BD. (1993). Absolute Quantitation of Water and Metabolites in the Human Brain. II. Metabolite Concentrations. J Magn Reson B. 102: 9-19.","journal-title":"J Magn Reson B"},{"key":"ref-1141215","doi-asserted-by":"crossref","first-page":"451","DOI":"10.1002\/mrm.1213","article-title":"In vivo 1H NMR spectroscopy of the human brain at 7 T","volume":"46","author":"Tk\u00e1c I","year":"2001","unstructured":"Tk\u00e1c I, Andersen P, Adriany G, et al. (2001). In vivo 1H NMR spectroscopy of the human brain at 7 T. Magn Reson Med. 46: 451-456.","journal-title":"Magn Reson Med"},{"key":"ref-1141216","doi-asserted-by":"crossref","DOI":"10.1002\/9780470512968","volume-title":"In vivo NMR spectroscopy: Principles and techniques","author":"de Graaf RA","year":"2007","unstructured":"de Graaf RA. (2007). In vivo NMR spectroscopy: Principles and techniques, 2nd ed.  John Wiley & Sons, Chichester, West Sussex, England, Hoboken, NJ.","edition":"2nd ed"},{"key":"ref-1141217","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/j.ab.2016.06.003","article-title":"B0 magnetic field homogeneity and shimming for in vivo magnetic resonance spectroscopy","volume":"529","author":"Juchem C","year":"2017","unstructured":"Juchem C, de Graaf RA. (2017). B0 magnetic field homogeneity and shimming for in vivo magnetic resonance spectroscopy. Anal Biochem. 529: 17-29.","journal-title":"Anal Biochem"},{"key":"ref-1141218","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1006\/jmre.2001.2318","article-title":"Optimization of residual water signal removal by HLSVD on simulated short echo time proton MR spectra of the human brain","volume":"150","author":"Cabanes E","year":"2001","unstructured":"Cabanes E, Confort-Gouny S, Le Fur Y, et al. (2001). Optimization of residual water signal removal by HLSVD on simulated short echo time proton MR spectra of the human brain. J Magn Reson. 150: 116-125.","journal-title":"J Magn Reson"},{"key":"ref-1141219","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1002\/mrm.26658","article-title":"Modeling real shim fields for very high degree (and order) B0 shimming of the human brain at 9.4 T","volume":"79","author":"Chang P","year":"2018","unstructured":"Chang P, Nassirpour S, Henning A. (2018). Modeling real shim fields for very high degree (and order) B0 shimming of the human brain at 9.4 T. Magn Reson Med. 79: 529-540.","journal-title":"Magn Reson Med"},{"key":"ref-1141220","doi-asserted-by":"crossref","first-page":"1145","DOI":"10.1002\/mrm.26758","article-title":"A comparison of optimization algorithms for localized in vivo B0 shimming","volume":"79","author":"Nassirpour S","year":"2018","unstructured":"Nassirpour S, Chang P, Fillmer A, Henning A. (2018). A comparison of optimization algorithms for localized in vivo B0 shimming. Magn Reson Med. 79: 1145-1156.","journal-title":"Magn Reson Med"},{"key":"ref-1141221","doi-asserted-by":"crossref","first-page":"1841","DOI":"10.1002\/mrm.26873","article-title":"Metabolite-cycled STEAM and semi-LASER localization for MR spectroscopy of the human brain at 9.4T","volume":"79","author":"Giapitzakis IA","year":"2018","unstructured":"Giapitzakis IA, Shao T, Avdievich N, et al. (2018). Metabolite-cycled STEAM and semi-LASER localization for MR spectroscopy of the human brain at 9.4T. Magn Reson Med. 79: 1841-1850.","journal-title":"Magn Reson Med"},{"key":"ref-1141222","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1006\/jmrb.1993.1055","article-title":"Absolute Quantitation of Water and Metabolites in the Human Brain. I. Compartments and Water","volume":"102","author":"Ernst T","year":"1993","unstructured":"Ernst T. (1993). Absolute Quantitation of Water and Metabolites in the Human Brain. I. Compartments and Water. J Magn Res B. 102: 1-8.","journal-title":"J Magn Res B"},{"key":"ref-1141223","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1002\/nbm.698","article-title":"Automatic quantitation of localized in vivo 1H spectra with LCModel","volume":"14","author":"Provencher SW","year":"2001","unstructured":"Provencher SW. (2001). Automatic quantitation of localized in vivo 1H spectra with LCModel. J NMR Biomed. 14: 260-264.","journal-title":"J NMR Biomed"},{"key":"ref-1141224","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1016\/j.ab.2016.10.019","article-title":"A practical guide to in vivo proton magnetic resonance spectroscopy at high magnetic fields","volume":"529","author":"Xin L","year":"2017","unstructured":"Xin L, Tk\u00e1\u010d I. (2017). A practical guide to in vivo proton magnetic resonance spectroscopy at high magnetic fields. Anal Biochem. 529: 30-39.","journal-title":"Anal Biochem"},{"key":"ref-1141225","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1006\/jmre.1999.1895","article-title":"Toward an in vivo neurochemical profile: quantification of 18 metabolites in short-echo-time (1)H NMR spectra of the rat brain","volume":"141","author":"Pfeuffer J","year":"1999","unstructured":"Pfeuffer J, Tk\u00e1c I, Provencher SW, Gruetter R. (1999). Toward an in vivo neurochemical profile: quantification of 18 metabolites in short-echo-time (1)H NMR spectra of the rat brain. J Magn Reson. 141: 104-120.","journal-title":"J Magn Reson"},{"key":"ref-1141226","doi-asserted-by":"crossref","first-page":"222","DOI":"10.1016\/j.mri.2008.06.009","article-title":"On the Voxel Size and Magnetic Field Strength Dependence of Spectral Resolution in MR Spectroscopy","volume":"27","author":"Fleysher R","year":"2008","unstructured":"Fleysher R, Fleysher L, Liu S, Gonen O. (2008). On the Voxel Size and Magnetic Field Strength Dependence of Spectral Resolution in MR Spectroscopy. Magn Reson Imaging. 27: 222-232.","journal-title":"Magn Reson Imaging"},{"key":"ref-1141227","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1002\/mrm.26118","article-title":"Mechanisms of SNR and line shape improvement by B0 correction in overdiscrete MRSI reconstruction","volume":"77","author":"Kirchner T","year":"2017","unstructured":"Kirchner T, Fillmer A, Henning A. (2017). Mechanisms of SNR and line shape improvement by B0 correction in overdiscrete MRSI reconstruction. Magn Reson Med. 77: 44-56.","journal-title":"Magn Reson Med"},{"key":"ref-1141228","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1186\/s12917-018-1396-1","article-title":"Effects of isoflurane, sevoflurane, propofol and alfaxalone on brain metabolism in dogs assessed by proton magnetic resonance spectroscopy (1H MRS)","volume":"14","author":"S\u00f6bbeler FJ","year":"2018","unstructured":"S\u00f6bbeler FJ, Carrera I, Pasloske K, et al. (2018). Effects of isoflurane, sevoflurane, propofol and alfaxalone on brain metabolism in dogs assessed by proton magnetic resonance spectroscopy (1H MRS). BMC Vet Res. 14: 69.","journal-title":"BMC Vet Res"},{"key":"ref-1141229","doi-asserted-by":"crossref","first-page":"1432","DOI":"10.1038\/jcbfm.2011.1","article-title":"The metabolomic profile during isoflurane anesthesia differs from propofol anesthesia in the live rodent brain","volume":"31","author":"Makaryus R","year":"2011","unstructured":"Makaryus R, Lee H, Yu M, et al. (2011). The metabolomic profile during isoflurane anesthesia differs from propofol anesthesia in the live rodent brain. J Cereb Blood Flow Metab. 31: 1432-1442.","journal-title":"J Cereb Blood Flow Metab"},{"key":"ref-1141230","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1016\/j.ejrad.2008.03.003","article-title":"Spectroscopic imaging: basic principles","volume":"67","author":"Skoch A","year":"2008","unstructured":"Skoch A, Jiru F, Bunke J. (2008). Spectroscopic imaging: basic principles. Eur J Radiol. 67: 230-239.","journal-title":"Eur J Radiol"},{"key":"ref-1141231","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1007\/BF03166960","article-title":"Methodology of H NMR Spectroscopy of the Human Brain at Very High Magnetic Fields","volume":"29","author":"Tk\u00e1\u010d I","year":"2005","unstructured":"Tk\u00e1\u010d I, Gruetter R. (2005). Methodology of H NMR Spectroscopy of the Human Brain at Very High Magnetic Fields. Appl Magn Reson. 29: 139-157.","journal-title":"Appl Magn Reson"},{"key":"ref-1141232","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1002\/nbm.891","article-title":"Issues of spectral quality in clinical 1H-magnetic resonance spectroscopy and a gallery of artifacts","volume":"17","author":"Kreis R","year":"2004","unstructured":"Kreis R. (2004). Issues of spectral quality in clinical 1H-magnetic resonance spectroscopy and a gallery of artifacts. NMR Biomed. 17: 361-381.","journal-title":"NMR Biomed"},{"key":"ref-1141233","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1002\/mrm.21302","article-title":"Short echo time 1H-MRSI of the human brain at 3T with minimal chemical shift displacement errors using adiabatic refocusing pulses","volume":"59","author":"Scheenen T","year":"2008","unstructured":"Scheenen T, Klomp D, et al. (2008). Short echo time 1H-MRSI of the human brain at 3T with minimal chemical shift displacement errors using adiabatic refocusing pulses. Magn Reson Med. 59: 1-6.","journal-title":"Magn Reson Med"},{"key":"ref-1141234","doi-asserted-by":"crossref","first-page":"692","DOI":"10.1002\/mrm.1092","article-title":"Calculations of B(1) distribution, SNR, and SAR for a surface coil adjacent to an anatomically-accurate human body model","volume":"45","author":"Collins CM","year":"2001","unstructured":"Collins CM, Smith MB. (2001). Calculations of B(1) distribution, SNR, and SAR for a surface coil adjacent to an anatomically-accurate human body model. Magn Reson Med. 45: 692-699.","journal-title":"Magn Reson Med"},{"key":"ref-1141235","doi-asserted-by":"crossref","first-page":"779","DOI":"10.1016\/j.mri.2015.04.002","article-title":"On the safety margin of using simplified human head models for local SAR simulations of B1-shimming at 7 Tesla","volume":"33","author":"Shao Y","year":"2015","unstructured":"Shao Y, Shang S, Wang S. (2015). On the safety margin of using simplified human head models for local SAR simulations of B1-shimming at 7 Tesla. Magn Reson Imaging. 33: 779-786.","journal-title":"Magn Reson Imaging"},{"key":"ref-1141236","doi-asserted-by":"crossref","first-page":"650","DOI":"10.1002\/jmri.20041","article-title":"Temperature and SAR calculations for a human head within volume and surface coils at 64 and 300 MHz","volume":"19","author":"Collins CM","year":"2004","unstructured":"Collins CM, Liu W, Wang J, et al. (2004). Temperature and SAR calculations for a human head within volume and surface coils at 64 and 300 MHz. J Magn Reson Imaging. 19: 650-656.","journal-title":"J Magn Reson Imaging"},{"key":"ref-1141237","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1016\/j.ejrad.2008.02.034","article-title":"The principles of quantification applied to in vivo proton MR spectroscopy","volume":"67","author":"Helms G","year":"2008","unstructured":"Helms G. (2008). The principles of quantification applied to in vivo proton MR spectroscopy. Eur J Radiol. 67: 218-229.","journal-title":"Eur J Radiol"},{"key":"ref-1141238","volume-title":"Magnetic Resonance Spectroscopy: Tools for Neuroscience Research and Emerging Clinical Applications","author":"Stagg C","year":"2014","unstructured":"Stagg C, Rothman DL. (2014). Magnetic Resonance Spectroscopy: Tools for Neuroscience Research and Emerging Clinical Applications.  Elsevier Science, Burlington."}],"container-title":["Polish Journal of Radiology"],"original-title":[],"link":[{"URL":"https:\/\/www.polradiol.com\/pdf-106277-108777","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.polradiol.com\/pdf-106277-108777","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,22]],"date-time":"2024-05-22T11:23:57Z","timestamp":1716377037000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.polradiol.com\/General-technical-remarks-on-1HMRS-translational-research-in-7T,106277,0,2.html"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,4,12]]},"references-count":47,"alternative-id":["106277"],"URL":"https:\/\/doi.org\/10.5114\/pjr.2019.85147","relation":{},"ISSN":["1899-0967"],"issn-type":[{"value":"1899-0967","type":"print"}],"subject":[],"published":{"date-parts":[[2019,4,12]]}}}