{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T10:24:23Z","timestamp":1791973463286,"version":"4.4.0"},"reference-count":12,"publisher":"Termedia Sp. z.o.o.","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pol J Radiol"],"abstract":"<jats:sec><jats:title>Introduction<\/jats:title><jats:p>Foreign body implantation into the soft tissues, either in the early period or late period, is a\u00a0common cause of emergency department admissions. Direct X-rays are preferred in the diagnosis of soft-tissue foreign-bodies. Herein, we aimed to analyse the detection rates of foreign bodies of various sizes placed in phantoms implanted into soft tissue by ultrasonography.<\/jats:p><\/jats:sec><jats:sec><jats:title>Material and methods<\/jats:title><jats:p>A\u00a0total of 740 pieces of chicken fillet were prepared as phantoms. No objects were implanted into 100 phantoms. We inserted glass, porcelain, plastic, wood, pencil tip, chicken bone, iron, walnut shell, and fishbone with a\u00a0length of &lt; 1 cm, 1-3 cm, and 3-5 cm into 20 pieces of chicken phantom in each size of foreign body (FB). In addition, 1-3 cm long peanut shell, &lt; 1 cm rose spikes, &lt; 1 cm cactus thorns, &lt; 1 cm pellets, and &lt; 1 cm staples were inserted into 20 pieces of chicken for each object. Each of the chicken pieces was placed inside a\u00a0latex glove and examined by ultrasonography.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The sensitivity of ultrasonography in the detection of the cactus thorn was 5%, whereas it ranged between 82.5 and 100% for other objects. For glass, plastic, wood, iron, and fishbone, we found that when the size exceeded 1 cm, the sensitivity increased.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>In the evaluation of soft tissue FBs, as the size of the FBs increases, the diagnostic value of ultrasonography increases.<\/jats:p><\/jats:sec>","DOI":"10.5114\/pjr.2021.108879","type":"journal-article","created":{"date-parts":[[2021,9,16]],"date-time":"2021-09-16T09:04:55Z","timestamp":1631783095000},"page":"496-499","source":"Crossref","is-referenced-by-count":9,"title":["Ultrasonography in soft-tissue foreign-body detection: a phantom study"],"prefix":"10.5114","volume":"86","author":[{"given":"Sermin","family":"Tok","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emine","family":"Kadioglu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"3061","published-online":{"date-parts":[[2021,8,20]]},"reference":[{"key":"ref-1147825","doi-asserted-by":"crossref","first-page":"1753","DOI":"10.4103\/0366-6999.209910","article-title":"Ultrasound-guided removal of retained soft tissue foreign body with late presentation","volume":"130","author":"Fu Y","year":"2017","unstructured":"Fu Y, Cui LG, Romagnoli C, et al. Ultrasound-guided removal of retained soft tissue foreign body with late presentation. Chin Med J 2017; 130: 1753-1754.","journal-title":"Chin Med J"},{"key":"ref-1147826","doi-asserted-by":"crossref","first-page":"531","DOI":"10.1016\/j.crad.2011.10.029","article-title":"Image-guided soft-tissue foreign body extraction\u2013success and pitfalls","volume":"67","author":"Bradley M","year":"2012","unstructured":"Bradley M. Image-guided soft-tissue foreign body extraction\u2013success and pitfalls. Clin Radiol 2012; 67: 531-534.","journal-title":"Clin Radiol"},{"key":"ref-1147827","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1016\/S0196-0644(96)70130-0","article-title":"Ultrasound versus radiography in the detection of soft-tissue foreign bodies","volume":"28","author":"Manthey DE","year":"1996","unstructured":"Manthey DE, Storrow AB, Milbourn JM, Wagner BJ. Ultrasound versus radiography in the detection of soft-tissue foreign bodies. Ann Emerg Med 1996; 28: 7-9.","journal-title":"Ann Emerg Med"},{"key":"ref-1147828","doi-asserted-by":"crossref","first-page":"1779","DOI":"10.1016\/j.ajem.2016.06.004","article-title":"Ultrasound for the evaluation of soft tissue foreign bodies before and after the addition of fluid to the surrounding interstitial space in a cadaveric model","volume":"34","author":"Saul T","year":"2016","unstructured":"Saul T, Siadecki SD, Rose G, et al. Ultrasound for the evaluation of soft tissue foreign bodies before and after the addition of fluid to the surrounding interstitial space in a cadaveric model. Am J Emerg Med 2016; 34: 1779-1782.","journal-title":"Am J Emerg Med"},{"key":"ref-1147829","doi-asserted-by":"crossref","first-page":"570","DOI":"10.1016\/j.annemergmed.2015.07.499","article-title":"Imaging foreign bodies: ingested, aspirated, and inserted","volume":"66","author":"Tseng HJ","year":"2015","unstructured":"Tseng HJ, Hanna TN, Shuaib W, et al. Imaging foreign bodies: ingested, aspirated, and inserted. Ann Emerg Med 2015; 66: 570-582.","journal-title":"Ann Emerg Med"},{"key":"ref-1147830","doi-asserted-by":"crossref","first-page":"1277","DOI":"10.2214\/ajr.155.6.2122680","article-title":"Localization and guided removalof soft-tissue foreign bodies with sonography","volume":"155","author":"Shiels II WE","year":"1990","unstructured":"Shiels II WE, Babcock DS, Wilson JL, et al. Localization and guided removalof soft-tissue foreign bodies with sonography. AJR Am J Roentgenol 1990; 155: 1277-1278.","journal-title":"AJR Am J Roentgenol"},{"key":"ref-1147831","first-page":"5","article-title":"The role of ultrasonography in detection and localization of radiolucent foreignbody in soft tissues of extremities","volume":"48","author":"Shrestha D","year":"2009","unstructured":"Shrestha D, Sharma UK, Mohammad R, Dhoju D. The role of ultrasonography in detection and localization of radiolucent foreignbody in soft tissues of extremities. JNMA J Nepal Med Assoc 2009; 48: 5-9.","journal-title":"JNMA J Nepal Med Assoc"},{"key":"ref-1147832","doi-asserted-by":"crossref","first-page":"661","DOI":"10.1016\/S0363-5023(05)80287-4","article-title":"Sensitivity and specificity of ultrasound in the diagnosis of foreign bodies in the hand","volume":"20","author":"Bray PW","year":"1995","unstructured":"Bray PW, Mahoney JL, Campbell JP. Sensitivity and specificity of ultrasound in the diagnosis of foreign bodies in the hand. J Hand Surg Am 1995; 20: 661-666.","journal-title":"J Hand Surg Am"},{"key":"ref-1147833","doi-asserted-by":"crossref","first-page":"147","DOI":"10.4103\/JMU.JMU_12_18","article-title":"Ultrasound evaluation of soft-tissue foreign bodies by US Army medics","volume":"26","author":"Driskell DL","year":"2018","unstructured":"Driskell DL, Gillum JB, Monti JD, Cronin A. Ultrasound evaluation of soft-tissue foreign bodies by US Army medics. J Med Ultrasound 2018; 26: 147-152.","journal-title":"J Med Ultrasound"},{"key":"ref-1147834","doi-asserted-by":"crossref","first-page":"1155","DOI":"10.2214\/ajr.176.5.1761155","article-title":"Sonography and radiography of soft-tissue foreign bodies","volume":"176","author":"Horton LK","year":"2001","unstructured":"Horton LK, Jacobson JA, Powell A, Fessell DP, Hayes CW. Sonography and radiography of soft-tissue foreign bodies. AJR Am J Roentgenol 2001; 176: 1155-1159.","journal-title":"AJR Am J Roentgenol"},{"key":"ref-1147835","doi-asserted-by":"crossref","first-page":"467","DOI":"10.11152\/mu-1562","article-title":"Comparison of cone beam computed tomography and ultrasonography with two types of probes in the detection of opaque and non-opaque foreign bodies","volume":"20","author":"Demiralp KO","year":"2018","unstructured":"Demiralp KO, Orhan K, Kur\u015fun-\u00c7akmak E\u015e, et al. Comparison of cone beam computed tomography and ultrasonography with two types of probes in the detection of opaque and non-opaque foreign bodies. Med Ultrason 2018; 20: 467-474.","journal-title":"Med Ultrason"},{"key":"ref-1147836","doi-asserted-by":"crossref","first-page":"855","DOI":"10.1148\/rg.2017160116","article-title":"Shear-wave elastography: basic physics and musculoskeletal applications","volume":"37","author":"Taljanovic MS","year":"2017","unstructured":"Taljanovic MS, Gimber LH, Becker GW, et al. Shear-wave elastography: basic physics and musculoskeletal applications. Radiographics 2017; 37: 855-870.","journal-title":"Radiographics"}],"container-title":["Polish Journal of Radiology"],"original-title":[],"link":[{"URL":"https:\/\/www.polradiol.com\/pdf-124163-108905","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.polradiol.com\/pdf-124163-108905","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,22]],"date-time":"2024-05-22T11:28:54Z","timestamp":1716377334000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.polradiol.com\/Ultrasonography-in-soft-tissue-foreign-body-detection-a-phantom-study,124163,0,2.html"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,8,20]]},"references-count":12,"alternative-id":["124163"],"URL":"https:\/\/doi.org\/10.5114\/pjr.2021.108879","relation":{},"ISSN":["1899-0967"],"issn-type":[{"value":"1899-0967","type":"print"}],"subject":[],"published":{"date-parts":[[2021,8,20]]}}}