{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T06:31:53Z","timestamp":1792737113997,"version":"4.5.0"},"reference-count":14,"publisher":"Termedia Sp. z.o.o.","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pol J Radiol"],"abstract":"<jats:sec><jats:title>Introduction<\/jats:title><jats:p>Computed tomography (CT)-guided percutaneous drainage is an established method for the treatment of abdominal abscesses. The purpose of this study is to evaluate the effectiveness and safety of drainage of abdominal abscesses with small-bore (6F and 9F) drains.<\/jats:p><\/jats:sec><jats:sec><jats:title>Material and methods<\/jats:title><jats:p>The analysis of a prospectively maintained database included 135 consecutive patients from a single centre with abdominal or pelvic abscesses, who underwent CT-guided drainage. Procedures were performed using a one-step trocar technique with 6F (40 procedures) or 9F (95 procedures) catheters. Technical success was defined as insertion of the drain into the abscess cavity and aspiration of the fluid sample. Clinical success was defined as resolution of infection without surgical intervention or upsizing of the drain.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The mean size of abscesses was 77.0 \u00b1 28.8 mm (32-220 mm). Thick fluid was aspirated from 129 collections; 6 collections contained thin fluid. Technical success was achieved in 100% of procedures. Clinical success was achieved in 94.8% of patients. Surgical drainage was necessary in 3.7% of patients and upsizing in 1.5% of patients. Complications of Clavien-Dindo grade III were noted in 2.2% of patients without grade IV or V adverse events. The mean radiation dose in terms of Dose Length Product was 617 \u00b1 467 mGy x cm. The mean procedure time was 28.0 \u00b1 11.3 min.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>CT-guided drainage of abdominal abscesses with small- and very small-bore drains is usually sufficient to obtain clinical success with a low complication rate in the case of thick fluid collections.<\/jats:p><\/jats:sec>","DOI":"10.5114\/pjr.2024.136420","type":"journal-article","created":{"date-parts":[[2024,3,22]],"date-time":"2024-03-22T08:14:16Z","timestamp":1711095256000},"page":"156-160","source":"Crossref","is-referenced-by-count":5,"title":["Effectiveness and safety of CT-guided drainage of abdominal abscesses with small and extra-small-bore drains: a\u00a0single-centre observational study"],"prefix":"10.5114","volume":"89","author":[{"given":"Grzegorz","family":"Rosiak","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jakub","family":"Franke","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Krzysztof","family":"Milczarek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dariusz","family":"Konecki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emilia","family":"Wnuk","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"3061","published-online":{"date-parts":[[2024,3,19]]},"reference":[{"key":"ref-1161199","doi-asserted-by":"crossref","first-page":"862","DOI":"10.1177\/000313481107700720","article-title":"Differences in morbidity and mortality with percutaneous versus open surgical drainage of postoperative intra-abdominal infections: a review of 686 cases","volume":"77","author":"Politano AD","year":"2011","unstructured":"Politano AD, Hranjec T, Rosenberger LH, et al. Differences in morbidity and mortality with percutaneous versus open surgical drainage of postoperative intra-abdominal infections: a review of 686 cases. Am Surg 2011; 77: 862-867.","journal-title":"Am Surg"},{"key":"ref-1161200","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvir.2019.12.001"},{"key":"ref-1161201","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1080\/13645706.2016.1261901","article-title":"CT fluoroscopy-guided percutaneous drainage: comparison of the one step and the Seldinger techniques","volume":"26","author":"Kajiwara K","year":"2017","unstructured":"Kajiwara K, Yamagami T, Ishikawa M, et al. CT fluoroscopy-guided percutaneous drainage: comparison of the one step and the Seldinger techniques. Minim Invasive Ther Allied Technol 2017; 26: 162-167.","journal-title":"Minim Invasive Ther Allied Technol"},{"key":"ref-1161202","doi-asserted-by":"crossref","first-page":"2160","DOI":"10.1007\/s00261-017-1108-5","article-title":"Bending percutaneous drainage catheters to facilitate CT-guided insertion using curved trocar technique","volume":"42","author":"Young AS","year":"2017","unstructured":"Young AS, Shyn PB, Johnson OW, et al. Bending percutaneous drainage catheters to facilitate CT-guided insertion using curved trocar technique. Abdom Radiol 2017; 42: 2160-2167.","journal-title":"Abdom Radiol"},{"key":"ref-1161203","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1097\/01.sla.0000133083.54934.ae","article-title":"Classification of surgical complications: A new proposal with evaluation in a cohort of 6336 patients and results of a survey","volume":"240","author":"Dindo D","year":"2004","unstructured":"Dindo D, Demartines N, Clavien PA. Classification of surgical complications: A new proposal with evaluation in a cohort of 6336 patients and results of a survey. Ann Surg 2004; 240: 205-213.","journal-title":"Ann Surg"},{"key":"ref-1161204","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvir.2017.06.019"},{"key":"ref-1161205","doi-asserted-by":"crossref","first-page":"1141","DOI":"10.1007\/s00270-017-1703-4","article-title":"Cirse quality assurance document and standards for classification of complications: the Cirse classification system","volume":"40","author":"Filippiadis DK","year":"2017","unstructured":"Filippiadis DK, Binkert C, Pellerin O, et al. Cirse quality assurance document and standards for classification of complications: the Cirse classification system. Cardiovasc Intervent Radiol 2017; 40: 1141-1146.","journal-title":"Cardiovasc Intervent Radiol"},{"key":"ref-1161206","doi-asserted-by":"crossref","first-page":"718","DOI":"10.1016\/j.amjsurg.2016.07.027","article-title":"Effect of abdominopelvic abscess drain size on drainage time and probability of occlusion","volume":"213","author":"Rotman JA","year":"2017","unstructured":"Rotman JA, Getrajdman GI, Maybody M, et al. Effect of abdominopelvic abscess drain size on drainage time and probability of occlusion. Am J Surg 2017; 213: 718-722.","journal-title":"Am J Surg"},{"key":"ref-1161207","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1080\/110241598750004229","article-title":"Percutaneous drainage of abdominal abscesses: are large-bore catheters necessary?","volume":"164","author":"R\u00f6thlin MA","year":"1998","unstructured":"R\u00f6thlin MA, Sch\u00f6b O, Klotz H, et al. Percutaneous drainage of abdominal abscesses: are large-bore catheters necessary? Eur J Surg 1998; 164: 419-424.","journal-title":"Eur J Surg"},{"key":"ref-1161208","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1007\/BF02552867","article-title":"The effect of drainage tube size on adequacy of percutaneous abscess drainage","volume":"8","author":"Gobien RP","year":"1985","unstructured":"Gobien RP, Stanley JH, Schabel SI, et al. The effect of drainage tube size on adequacy of percutaneous abscess drainage. Cardiovasc Intervent Radiol 1985; 8: 100-102.","journal-title":"Cardiovasc Intervent Radiol"},{"key":"ref-1161209","doi-asserted-by":"publisher","DOI":"10.3390\/diagnostics11050826"},{"key":"ref-1161210","doi-asserted-by":"crossref","first-page":"701","DOI":"10.1016\/j.crad.2021.05.018","article-title":"Initial experience of operatorcontrolled gating technique under free breathing during CT-guided percutaneous drainage of postoperative deep upper abdominal fluid collections","volume":"76","author":"Suyama Y","year":"2021","unstructured":"Suyama Y, Edo H, Kuwamura H, et al. Initial experience of operatorcontrolled gating technique under free breathing during CT-guided percutaneous drainage of postoperative deep upper abdominal fluid collections. Clin Radiol 2021; 76: 701-705.","journal-title":"Clin Radiol"},{"key":"ref-1161211","doi-asserted-by":"crossref","first-page":"2195","DOI":"10.1007\/s00261-020-02864-1","article-title":"Factors influencing cumulative radiation dose from percutaneous intra-abdominal abscess drainage in the setting of inflammatory bowel disease","volume":"46","author":"An TJ","year":"2021","unstructured":"An TJ, Tabari A, Gee MS, et al. Factors influencing cumulative radiation dose from percutaneous intra-abdominal abscess drainage in the setting of inflammatory bowel disease. Abdom Radiol (NY) 2021; 46: 2195-2202.","journal-title":"Abdom Radiol (NY)"},{"key":"ref-1161212","doi-asserted-by":"publisher","DOI":"10.3390\/diagnostics12092243"}],"container-title":["Polish Journal of Radiology"],"original-title":[],"link":[{"URL":"https:\/\/www.polradiol.com\/pdf-183149-109150","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.polradiol.com\/pdf-183149-109150","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,22]],"date-time":"2024-05-22T11:14:14Z","timestamp":1716376454000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.polradiol.com\/Effectiveness-and-safety-of-CT-guided-drainage-of-abdominal-abscesses-with-small,183149,0,2.html"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,3,19]]},"references-count":14,"alternative-id":["183149"],"URL":"https:\/\/doi.org\/10.5114\/pjr.2024.136420","relation":{},"ISSN":["1899-0967"],"issn-type":[{"value":"1899-0967","type":"print"}],"subject":[],"published":{"date-parts":[[2024,3,19]]}}}