{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T05:42:53Z","timestamp":1787031773737,"version":"build-2736575974"},"reference-count":17,"publisher":"Korean Continence Society","issue":"4","license":[{"start":{"date-parts":[[2025,12,31]],"date-time":"2025-12-31T00:00:00Z","timestamp":1767139200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["einj.org"],"crossmark-restriction":true},"short-container-title":["Int Neurourol J"],"published-print":{"date-parts":[[2025,12,31]]},"abstract":"<jats:p>Purpose: To compare the accuracy of portable ultrasound bladder scanner (PUBS) for measuring bladder volume (BV) using manual fanning scan (MFS) and traditional motorized scan (TMS) methods.Methods: Patients with lower urinary tract symptoms who underwent a urodynamic study at the urology outpatient clinic from October to December 2024 were prospectively enrolled. BV was measured using TMS-type (TMS-BV) and MFS-type (MFS-BV) PUBS prior to free uroflowmetry. True BV (T-BV) was defined as the sum of the voided volume and the postvoid residual volume drained through the urethral catheter after voiding. TMS-BV and MFS-BV were compared and analyzed against T-BV.Results: Data from 39 patients (30 males and 9 females; mean age, 65.3\u00b114.8 years) were analyzed. TMS-BV (230.9\u00b1157.9 mL) and MFS-BV (222.6\u00b1154.2 mL) did not differ significantly from T-BV (230.6\u00b1156.6 mL) (P&gt;0.05). Comparison of the percentage of difference in volume between TMS-BV and MFS-BV across 100-mL BV ranges revealed no significant difference (P&gt;0.05). The mean difference between TMS-BV and T-BV (0.2\u00b150.2) did not differ significantly from the mean difference between MFS-BV and T-BV (-8.0\u00b169.1) (P&gt;0.05). The correlation between TMS-BV and T-BV (R&lt;sup&gt;2&lt;\/sup&gt;=0.90) was stronger than that between MFS-BV and T-BV (R&lt;sup&gt;2&lt;\/sup&gt;=0.81).Conclusions: The correlation between MFS-type PUBS and T-BV was lower than that between TMS-type PUBS and T-BV. However, the measurement accuracy of BV was similar using both methods.<\/jats:p>","DOI":"10.5213\/inj.2550190.095","type":"journal-article","created":{"date-parts":[[2025,12,29]],"date-time":"2025-12-29T00:02:08Z","timestamp":1766966528000},"page":"296-301","update-policy":"https:\/\/doi.org\/10.5213\/crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Accuracy of Portable Ultrasound Measurement of the Bladder Volume Using the Manual Fanning Scan and Traditional Motorized Scan Methods"],"prefix":"10.5213","volume":"29","author":[{"given":"Hyun Ju","family":"Jeong","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0322-3539","authenticated-orcid":true,"given":"Seung-June","family":"Oh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"3166","reference":[{"key":"ref1","volume-title":""},{"key":"ref2","volume-title":"","author":"Cornu"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1002\/nau.22671"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1016\/s0090-4295(03)00559-4"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1007\/s00192-016-3224-0"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1016\/j.urology.2008.02.033"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1002\/nau.20977"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpurol.2022.02.001"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1111\/tmi.12657"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.21106\/ijma.294"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1002\/mp.16638"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1016\/s0022-5347(17)63094-5"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.3390\/s21144893"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.14440\/bladder.2018.565"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1016\/s1028-4559(09)60300-4"},{"key":"ref16","first-page":"9829","volume-title":"Bladder volume correction factors measured with 3D ultrasound and BladderScan","author":"Vinod","year":"2019"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.4037\/ajcc2020741"}],"container-title":["International Neurourology Journal"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/einj.org\/upload\/pdf\/inj-2550190-095.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/einj.org\/journal\/view.php?doi=10.5213\/inj.2550190.095","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/einj.org\/upload\/pdf\/inj-2550190-095.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,29]],"date-time":"2025-12-29T07:26:38Z","timestamp":1766993198000},"score":1,"resource":{"primary":{"URL":"http:\/\/einj.org\/journal\/view.php?doi=10.5213\/inj.2550190.095"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,31]]},"references-count":17,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2025,12]]}},"URL":"https:\/\/doi.org\/10.5213\/inj.2550190.095","relation":{},"ISSN":["2093-6931"],"issn-type":[{"value":"2093-6931","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12,31]]},"assertion":[{"value":"2025-07-18","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-09-02","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-12-31","order":2,"name":"published","label":"Published online","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-12-31","order":3,"name":"published","label":"Print publication","group":{"name":"publication_history","label":"Publication History"}}]}}