{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,9,30]],"date-time":"2023-09-30T11:49:23Z","timestamp":1696074563045},"reference-count":14,"publisher":"Surgical Technology Online","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Surg Technol Int."],"abstract":"<jats:p>Introduction: Post-thyroidectomy hemorrhage is a rare but potentially life-threatening and unpredictable complication of thyroid surgery. Therefore, intraoperative bleeding control and hemostasis are crucial. However, the most efficient, cost-effective, and standardized way to achieve this is not clear. This study aimed to evaluate the outcome of total thyroidectomy (TT) and partial thyroidectomy (PT) performed using the Vivostat\u00ae hemostatic system (Vivostat A\/S, Liller\u00f8d, Denmark). \nMethods: Patients underwent TT and PT for benign and malignant diseases (multinodular goiter, Graves\u2019 disease, differentiated thyroid carcinoma). The primary endpoint was 1st-day postoperative drain output and bleeding that required reintervention. Secondary endpoints included surgery duration and postsurgical complications (vocal fold palsy, hypocalcemia, seroma, wound infection). \nResults: Between October 2020 and December 2020, 56 patients were enrolled; 69.6% female; mean age 49.5 years. The mean 24-h drain output was 40 ml. No redo surgery was needed. Seroma was present in 5.3% of cases; no permanent vocal palsy or hypocalcemia was observed.  \nConclusion: This study shows that the Vivostat\u00ae system is both safe and effective for hemostasis during thyroid surgery.<\/jats:p>","DOI":"10.52198\/21.sti.38.so1441","type":"journal-article","created":{"date-parts":[[2021,6,15]],"date-time":"2021-06-15T08:34:43Z","timestamp":1623746083000},"source":"Crossref","is-referenced-by-count":2,"title":["Use of Vivostat\u00ae Autologous Fibrin Sealant in Thyroid Surgery"],"prefix":"10.52198","author":[{"given":"Antonella","family":"Pino","sequence":"first","affiliation":[{"name":"Division for Endocrine and Minimally Invasive Surgery, Department of Human Pathology in Adulthood and Childhood ''G. Barresi'', University Hospital G. Martino, University of Messina, Messina, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Francesco","family":"Frattini","sequence":"additional","affiliation":[{"name":"Division of General Surgery, Ospedale di Circolo e Fondazione Macchi di Varese - ASST dei Sette Laghi, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hui","family":"Sun","sequence":"additional","affiliation":[{"name":"Division of Thyroid Surgery, China-Japan Union Hospital of Jilin University, Jilin Provincial Key  Laboratory of Surgical Translational Medicine, Changchun, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daqi","family":"Zhang","sequence":"additional","affiliation":[{"name":"Division of Thyroid Surgery, China-Japan Union Hospital of Jilin University, Jilin Provincial Key  Laboratory of Surgical Translational Medicine, Changchun, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Che","family":"Wu","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology-Head and Neck Surgery, Kaohsiung Medical University Hospital,  Kaohsiung Medical University, Kaohsiung, Taiwan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hoon","family":"Kim\u00b8","sequence":"additional","affiliation":[{"name":"Department of Surgery, Division of Breast and Endocrine Surgery, Minimally Invasive Surgery and Robotic Surgery Center, KUMC Thyroid Center Korea University, Anam Hospital, Seoul, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gianlorenzo","family":"Dionigi","sequence":"additional","affiliation":[{"name":"Division for Endocrine and Minimally Invasive Surgery, Department of Human Pathology in Adulthood and Childhood ''G. Barresi'', University Hospital G. Martino, University of Messina, Messina, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"18996","published-online":{"date-parts":[[2021,5,6]]},"reference":[{"key":"ref0","doi-asserted-by":"publisher","unstructured":"1. Pontin A, Pino A, Caruso E, et al. Postoperative Bleeding After Thyroid Surgery: Care Instructions. Sisli Etfal Hastan Tip Bul 2019 Nov 21;53(4):329-36.","DOI":"10.14744\/semb.2019.95914"},{"key":"ref1","doi-asserted-by":"crossref","unstructured":"2. Liu J, Sun W, Dong W, et al. Risk factors for post-thyroidectomy haemorrhage: A meta-analysis. Eur J Endocrinol 2017 May;176(5):591-602.","DOI":"10.1530\/EJE-16-0757"},{"key":"ref2","doi-asserted-by":"publisher","unstructured":"3. Karanikolic A, Djordjevic M, Djordjevic N, Golubovic I. Effect of fibrin vs cellulose based haemostatic agents with traditional haemostatic procedures in thyroid surgery. Pak J Med Sci 2017 Nov-Dec;33(6): 1360-5.","DOI":"10.12669\/pjms.336.13692"},{"key":"ref3","doi-asserted-by":"publisher","unstructured":"4. Alesina PF, Rolfs T, Walz MK. Bipolar thermofusion vessel sealing system (TVS) versus conventional vessel ligation (CVL) in thyroid surgery-results of a prospective study. Langenbecks Arch Surg 2010 Feb;395(2): 115-9.","DOI":"10.1007\/s00423-009-0571-z"},{"key":"ref4","doi-asserted-by":"publisher","unstructured":"5. Dionigi G, Boni L, Rovera F, Dionigi R. Thyroid surgery: new approach to dissection and hemostasis. Surg Technol Int 2006;15:75-80. PMID: 17029165.","DOI":"10.1186\/1750-1164-1-3"},{"key":"ref5","doi-asserted-by":"publisher","unstructured":"6. Scaroni M, von Holzen U, Nebiker CA. Effectiveness of hemostatic agents in thyroid surgery for the prevention of postoperative bleeding. Sci Rep 2020;10:1753 doi.org\/10.1038\/s41598-020-58666-4","DOI":"10.1038\/s41598-020-58666-4"},{"key":"ref6","doi-asserted-by":"publisher","unstructured":"7. Al-Qahtani AS, Abouzeid Osman T. Could post-thyroidectomy bleeding be the clue to modify the concept of postoperative drainage? A prospective randomized controlled study. Asian J Surg 2018 Sep;41(5):511-6.","DOI":"10.1016\/j.asjsur.2017.08.004"},{"key":"ref7","doi-asserted-by":"publisher","unstructured":"8. Farooq MS, Nouraei R, Kaddour H, Saharay M. Patterns, timing and consequences of post-thyroidectomy haemorrhage. Ann R Coll Surg Engl 2017 Jan;99(1): 60-2.","DOI":"10.1308\/rcsann.2016.0270"},{"key":"ref8","doi-asserted-by":"publisher","unstructured":"9. Pacilli M, Tartaglia N, Gerundo A, Pavone G, Fersini A, Ambrosi A. Energy based vessel sealing devices in thyroid surgery: A systematic review to clarify the relationship with recurrent laryngeal nerve injuries. Medicina (Kaunas) 2020 Nov 27;56(12):651.","DOI":"10.3390\/medicina56120651"},{"key":"ref9","doi-asserted-by":"publisher","unstructured":"10. Tartaglia N, Di Lascia A, Lizzi V, et al. Haemostasis in Thyroid Surgery: Collagen-Fibrinogen-Thrombin Patch versus Cellulose Gauze - Our Experience. Surg Res Pract 2016;2016:3058754.","DOI":"10.1155\/2016\/3058754"},{"key":"ref10","doi-asserted-by":"publisher","unstructured":"11. Rossini R, Musumeci G, Visconti LO, et al. Perioperative management of antiplatelet therapy in patients with coronary stents undergoing cardiac and non-cardiac surgery: a consensus document from Italian cardiological, surgical and anaesthesiological societies. EuroIntervention 2014 May;10(1):38-46. doi: 10.4244\/ EIJV10I1A8. PMID: 24832636.","DOI":"10.4244\/eijv10i1a8"},{"key":"ref11","doi-asserted-by":"publisher","unstructured":"12. Dionigi G, Bacuzzi A, Bertocchi V, et al. Safe incorporation of new technologies in thyroid surgery. Expert Rev Med Devices 2008 Nov;5(6):747-58. doi: 10.1586\/17434440.5.6.747. PMID: 19025350.","DOI":"10.1586\/17434440.5.6.747"},{"key":"ref12","doi-asserted-by":"publisher","unstructured":"13. Boni L, Benevento A, Dionigi G, Dionigi R. A new device for minor bleeding control and blunt dissection in minimally invasive surgery. Surg Endosc 2003 Feb; 17(2):282-4. doi: 10.1007\/s00464-002-9038-9. Epub 2002 Oct 8. PMID: 12364993.","DOI":"10.1007\/s00464-002-9038-9"},{"key":"ref13","doi-asserted-by":"publisher","unstructured":"14. Dionigi G, Boni L, Rausei S, et al. The safety of energy-based devices in open thyroidectomy: a prospective, randomised study comparing the LigaSure\u2122 (LF1212) and the Harmonic\u00ae FOCUS. Langenbecks Arch Surg 2012 Jun;397(5):817-23. doi: 10.1007\/ s00423-011-0898-0. Epub 2012 Jan 10. PMID: 22230963.","DOI":"10.1007\/s00423-011-0898-0"}],"container-title":["Surgical Technology Online"],"original-title":[],"language":"en","deposited":{"date-parts":[[2021,6,15]],"date-time":"2021-06-15T08:34:52Z","timestamp":1623746092000},"score":1,"resource":{"primary":{"URL":"http:\/\/surgicaltechnology.com\/38-Surgical-Overview.htm#1441"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,5,6]]},"references-count":14,"URL":"https:\/\/doi.org\/10.52198\/21.sti.38.so1441","archive":["CLOCKSS"],"relation":{},"ISSN":["1090-3941"],"issn-type":[{"value":"1090-3941","type":"print"}],"subject":[],"published":{"date-parts":[[2021,5,6]]}}}