{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T16:52:47Z","timestamp":1791219167206,"version":"4.1.0"},"reference-count":51,"publisher":"Organization for Human Brain Mapping","issue":"SI 1","license":[{"start":{"date-parts":[[2026,2,13]],"date-time":"2026-02-13T00:00:00Z","timestamp":1770940800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["U24-NS120056"],"award-info":[{"award-number":["U24-NS120056"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["R03-EB038095"],"award-info":[{"award-number":["R03-EB038095"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"abstract":"<jats:p>We present an open, vendor-neutral BOLD SMS-EPI protocol tailored for multi-site fMRI studies, intended as a drop-in replacement for conventional vendor-specific acquisition and reconstruction pipelines. Built on Pulseq\u2014an emerging standard for cross-platform MRI pulse sequence development\u2014our protocol ensures identical SMS-EPI pulse sequences and image reconstruction across scanner vendors. This provides, for the first time, known and consistent experimental conditions across sites and scanner software versions. We begin by reviewing the current capabilities of the Pulseq framework, including vendor support and safety considerations. We then detail our SMS-EPI implementation and demonstrate its performance using resting-state fMRI pilot data from healthy volunteers, showing reduced site variance compared to corresponding vendor protocols on Siemens and GE scanners. To support adoption, we provide practical resources to help researchers integrate Pulseq fMRI into their studies, including example text for grant proposals and IRB submissions. These resources are freely available at https:\/\/github.com\/HarmonizedMRI\/Functional (https:\/\/github.com\/HarmonizedMRI\/Functional). Our vision is for Pulseq fMRI to become the standard for multi-site research, enabling more reproducible science and serving as a reference for the development of novel acquisition and reconstruction methods.<\/jats:p>","DOI":"10.52294\/001c.155279","type":"journal-article","created":{"date-parts":[[2026,2,13]],"date-time":"2026-02-13T14:28:47Z","timestamp":1770992927000},"source":"Crossref","is-referenced-by-count":2,"title":["A vendor-neutral functional MRI acquisition protocol for multi-site studies"],"prefix":"10.52294","volume":"6","author":[{"given":"Jon-Fredrik","family":"Nielsen","sequence":"first","affiliation":[{"id":[{"id":"https:\/\/ror.org\/00jmfr291","id-type":"ROR","asserted-by":"publisher"}],"name":"University of Michigan","department":["Functional MRI Laboratory, Department of Radiology"]},{"id":[{"id":"https:\/\/ror.org\/00jmfr291","id-type":"ROR","asserted-by":"publisher"}],"name":"University of Michigan","department":["Department of Biomedical Engineering"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maximillian K.","family":"Egan","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/00jmfr291","id-type":"ROR","asserted-by":"publisher"}],"name":"University of Michigan","department":["Functional MRI Laboratory, Department of Radiology"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qingping","family":"Chen","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/03vzbgh69","id-type":"ROR","asserted-by":"publisher"}],"name":"University Medical Center Freiburg","department":["Division of Medical Physics, Department of Radiology"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mojtaba","family":"Shafiekhani","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/03vzbgh69","id-type":"ROR","asserted-by":"publisher"}],"name":"University Medical Center Freiburg","department":["Division of Medical Physics, Department of Radiology"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James H.","family":"Wang","sequence":"additional","affiliation":[{"name":"University of Wisconsin\u2013Madison","department":["Department of Radiology"]},{"name":"University of Wisconsin\u2013Madison","department":["Department of Medical Physics"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Samuel A.","family":"Hurley","sequence":"additional","affiliation":[{"name":"University of Wisconsin\u2013Madison","department":["Department of Medical Physics"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeffrey S.","family":"Soldate","sequence":"additional","affiliation":[{"name":"Fralin Biomedical Research institute at VTC"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan","family":"Lisinski","sequence":"additional","affiliation":[{"name":"Fralin Biomedical Research institute at VTC"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephen M.","family":"LaConte","sequence":"additional","affiliation":[{"name":"Fralin Biomedical Research institute at VTC"},{"id":[{"id":"https:\/\/ror.org\/02smfhw86","id-type":"ROR","asserted-by":"publisher"}],"name":"Virginia Tech","department":["Department of Biomedical Engineering"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bradley P.","family":"Sutton","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/047426m28","id-type":"ROR","asserted-by":"publisher"}],"name":"University of Illinois Urbana-Champaign","department":["Grainger College of Engineering, Bioengineering Department and Beckman Institute"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R. Allen","family":"Waggoner","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/04j1n1c04","id-type":"ROR","asserted-by":"publisher"}],"name":"RIKEN Center for Brain Science"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R\u00fcdiger","family":"Stirnberg","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/043j0f473","id-type":"ROR","asserted-by":"publisher"}],"name":"German Center for Neurodegenerative Diseases"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tony","family":"St\u00f6cker","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/043j0f473","id-type":"ROR","asserted-by":"publisher"}],"name":"German Center for Neurodegenerative Diseases"},{"id":[{"id":"https:\/\/ror.org\/041nas322","id-type":"ROR","asserted-by":"publisher"}],"name":"University of Bonn","department":["Department of Physics & Astronomy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeffrey A.","family":"Fessler","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/00jmfr291","id-type":"ROR","asserted-by":"publisher"}],"name":"University of Michigan","department":["Department of Biomedical Engineering"]},{"id":[{"id":"https:\/\/ror.org\/00jmfr291","id-type":"ROR","asserted-by":"publisher"}],"name":"University of Michigan","department":["Department of Electrical Engineering and Computer Science"]},{"id":[{"id":"https:\/\/ror.org\/00jmfr291","id-type":"ROR","asserted-by":"publisher"}],"name":"University of Michigan","department":["Department of Radiology"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Douglas C.","family":"Noll","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/00jmfr291","id-type":"ROR","asserted-by":"publisher"}],"name":"University of Michigan","department":["Functional MRI Laboratory, Department of Radiology"]},{"id":[{"id":"https:\/\/ror.org\/00jmfr291","id-type":"ROR","asserted-by":"publisher"}],"name":"University of Michigan","department":["Department of Biomedical Engineering"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maxim","family":"Zaitsev","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/03vzbgh69","id-type":"ROR","asserted-by":"publisher"}],"name":"University Medical Center Freiburg","department":["Division of Medical Physics, Department of Radiology"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Scott J.","family":"Peltier","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/00jmfr291","id-type":"ROR","asserted-by":"publisher"}],"name":"University of Michigan","department":["Functional MRI Laboratory, Department of Radiology"]},{"id":[{"id":"https:\/\/ror.org\/00jmfr291","id-type":"ROR","asserted-by":"publisher"}],"name":"University of Michigan","department":["Department of Biomedical Engineering"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"29889","published-online":{"date-parts":[[2026,2,13]]},"reference":[{"issue":"6","key":"ref1","doi-asserted-by":"publisher","first-page":"3128","DOI":"10.1002\/mrm.26990","article-title":"TOPPE: A framework for rapid prototyping of MR pulse sequences","volume":"79","author":"J. F. Nielsen","year":"2018","journal-title":"Magnetic resonance in medicine"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.30601","article-title":"pTx-Pulseq in hybrid sequences: Accessible and advanced hybrid open-source MRI sequences on Philips scanners","author":"T. H. M. Roos","year":"2025","journal-title":"Magnetic Resonance in Medicine"},{"key":"ref3","first-page":"3234","article-title":"Arbitrary pulse sequence execution with Pulseq on Philips MRI scanners","volume":"32","author":"I. A. Shaik","year":"2024","journal-title":"Proc Int Soc Magn Reson Med"},{"key":"ref4","article-title":"PulCeq: A C Representation of the Pulseq Specification","journal-title":"Github"},{"key":"ref5","first-page":"1275","article-title":"Pulserver: An Open-Source Pulseq-Based Client-Server Framework For Vendor Agnostic, Interactive MR Sequence Design","volume":"33","author":"M. Cencini","year":"2025","journal-title":"Proc Int Soc Magn Reson Med"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.30509","article-title":"Open-source implementation of X-nuclear sequences using the Pulseq framework","author":"X. Liu","year":"2025","journal-title":"Magnetic resonance in medicine"},{"key":"ref7","article-title":"Safe_pns_prediction: Matlab Implementation of Peripheral Nerve Stimulation (PNS) Prediction at Siemens MRI Systems Based on the SAFE Model by Herbank and Gebhardt","author":"F. Szczepankiewicz","journal-title":"Github"},{"key":"ref8","article-title":"SAFE-model\u2014a new method for predicting peripheral nerve stimulations in MRI","author":"F. X. Hebrank","year":"2000","journal-title":"Proc Intl Soc Mag Res Med"},{"issue":"109007","key":"ref9","doi-asserted-by":"publisher","first-page":"109007","DOI":"10.1016\/j.jneumeth.2020.109007","article-title":"Gradient waveform design for tensor-valued encoding in diffusion MRI","volume":"348","author":"F. Szczepankiewicz","year":"2021","journal-title":"J Neurosci Methods"},{"issue":"2","key":"ref10","doi-asserted-by":"publisher","first-page":"518","DOI":"10.1002\/mrm.25440","article-title":"Peripheral nerve stimulation-optimal gradient waveform design","volume":"74","author":"R. F. Schulte","year":"2015","journal-title":"Magnetic resonance in medicine"},{"issue":"6","key":"ref11","doi-asserted-by":"publisher","first-page":"1948","DOI":"10.1002\/jmri.26785","article-title":"Assessing effects of scanner upgrades for clinical studies","volume":"50","author":"K. E. Keenan","year":"2019","journal-title":"J Magn Reson Imaging"},{"key":"ref12","article-title":"MATLAB implementation of the IEC nerve impulse response PNS model"},{"key":"ref13","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1016\/j.dcn.2018.03.001","article-title":"The Adolescent Brain Cognitive Development (ABCD) study: Imaging acquisition across 21 sites","volume":"32","author":"B. J. Casey","year":"2018","journal-title":"Dev Cogn Neurosci"},{"issue":"3","key":"ref14","doi-asserted-by":"publisher","first-page":"1540","DOI":"10.1002\/mrm.28486","article-title":"Segmented K-space blipped-controlled aliasing in parallel imaging for high spatiotemporal resolution EPI","volume":"85","author":"R. Stirnberg","year":"2021","journal-title":"Magn Reson Med"},{"key":"ref15","article-title":"Vendor-Agnostic SMS-EPI fMRI Sequence and Image Reconstruction","year":"2023","journal-title":"University of Michigan"},{"issue":"1","key":"ref16","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1109\/42.75611","article-title":"Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm (NMR imaging)","volume":"10","author":"J. Pauly","year":"1991","journal-title":"IEEE transactions on medical imaging"},{"key":"ref17","first-page":"2209","article-title":"Optimized phase schedules for minimizing peak RF power in simultaneous multi-slice RF excitation pulses","volume":"20","author":"E. Wong","year":"2012","journal-title":"Proceedings of the 20th Annual Meeting of ISMRM, Melbourne, Australia"},{"issue":"2","key":"ref18","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1002\/mrm.1910210210","article-title":"Spoiling of transverse magnetization in steady-state sequences","volume":"21","author":"Y. Zur","year":"1991","journal-title":"Magn Reson Med"},{"issue":"6","key":"ref19","doi-asserted-by":"publisher","first-page":"2071","DOI":"10.1002\/mrm.24875","article-title":"Three-dimensional Fourier encoding of simultaneously excited slices: generalized acquisition and reconstruction framework: 3D Fourier Encoding for SMS Acquisitions","volume":"71","author":"B. Zahneisen","year":"2014","journal-title":"Magn Reson Med"},{"issue":"5","key":"ref20","doi-asserted-by":"publisher","first-page":"1210","DOI":"10.1002\/mrm.23097","article-title":"Blipped-controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g-factor penalty: Blipped-CAIPI for Simultaneous Multislice EPI","volume":"67","author":"K. Setsompop","year":"2012","journal-title":"Magn Reson Med"},{"key":"ref21","article-title":"Grappa-Tools: MATLAB Toolkit for GRAPPA and Slice GRAPPA Reconstruction","author":"M. Chiew","journal-title":"Github"},{"issue":"4","key":"ref22","doi-asserted-by":"publisher","first-page":"1544","DOI":"10.1002\/mrm.26235","article-title":"Pulseq: a rapid and hardware-independent pulse sequence prototyping framework","volume":"77","author":"K. J. Layton","year":"2017","journal-title":"Magnetic resonance in medicine"},{"key":"ref23","article-title":"Pygrappa: Python Implementations of GRAPPA-like Algorithms","author":"N. McKibben","journal-title":"Github"},{"key":"ref24","article-title":"BART Toolbox"},{"key":"ref25","first-page":"1195","article-title":"The BART toolbox for computational magnetic resonance imaging","volume":"1182","author":"M. Uecker","year":"2007"},{"key":"ref26","article-title":"Gadgetron"},{"issue":"3","key":"ref27","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1089\/brain.2012.0073","article-title":"Conn: a functional connectivity toolbox for correlated and anticorrelated brain networks","volume":"2","author":"S. Whitfield-Gabrieli","year":"2012","journal-title":"Brain Connect"},{"key":"ref28","doi-asserted-by":"publisher","DOI":"10.56441\/hilbertpress.2246.5840","article-title":"CONN functional connectivity toolbox: RRID SCR_009550, release 22","author":"S. Nieto-Castanon","year":"2022"},{"key":"ref29","article-title":"Statistical Parametric Mapping: The Analysis of Functional Brain Images","author":"W. D. Penny","year":"2011"},{"key":"ref30","doi-asserted-by":"publisher","DOI":"10.56441\/hilbertpress.2207.6598","article-title":"Handbook of functional connectivity magnetic resonance imaging methods in CONN","author":"A. Nieto-Castanon","year":"2020"},{"issue":"4","key":"ref31","doi-asserted-by":"publisher","first-page":"665","DOI":"10.1016\/j.neuron.2011.09.006","article-title":"Functional network organization of the human brain","volume":"72","author":"J. D. Power","year":"2011","journal-title":"Neuron"},{"issue":"3","key":"ref32","doi-asserted-by":"publisher","first-page":"533","DOI":"10.1007\/s10334-025-01247-1","article-title":"Automated, open-source, vendor-independent quality assurance protocol based on the Pulseq framework","volume":"38","author":"Q. Chen","year":"2025","journal-title":"MAGMA"},{"issue":"5","key":"ref33","doi-asserted-by":"publisher","first-page":"952","DOI":"10.1002\/(SICI)1522-2594(199911)42:5","article-title":"SENSE: sensitivity encoding for fast MRI","volume":"42","author":"K. P. Pruessmann","year":"1999","journal-title":"Magnetic Resonance in Medicine: An Official Journal of the International Society for Magnetic Resonance in Medicine"},{"issue":"3","key":"ref34","doi-asserted-by":"publisher","first-page":"367","DOI":"10.1007\/s10334-025-01236-4","article-title":"MRI acquisition and reconstruction cookbook: recipes for reproducibility, served with real-world flavour","volume":"38","author":"J. I. Tamir","year":"2025","journal-title":"MAGMA"},{"key":"ref35","article-title":"HarmonizedMRI NIH grant text templates"},{"key":"ref36","article-title":"University of Michigan Pulseq single IRB: Manual of Operations and Procedures"},{"key":"ref37","first-page":"3479","article-title":"Open-Source, Multi-Vendor B0 Shimming Protocol","volume":"33","author":"J. Pothoof","year":"2025","journal-title":"Proc Int Soc Magn Reson Med"},{"issue":"4","key":"ref38","doi-asserted-by":"publisher","first-page":"1401","DOI":"10.1002\/mrm.29528","article-title":"Shimming toolbox: An open-source software toolbox for B0 and B1 shimming in MRI","volume":"89","author":"A. D'Astous","year":"2023","journal-title":"Magn Reson Med"},{"issue":"4","key":"ref39","doi-asserted-by":"publisher","first-page":"1485","DOI":"10.1002\/mrm.30573","article-title":"gammaSTAR: A framework for the development of dynamic, real-time capable MR sequences","volume":"94","author":"S. Konstandin","year":"2025","journal-title":"Magn Reson Med"},{"key":"ref40","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1016\/j.mri.2018.03.008","article-title":"Pulseq-Graphical Programming Interface: Open source visual environment for prototyping pulse sequences and integrated magnetic resonance imaging algorithm development","volume":"52","author":"K. S. Ravi","year":"2018","journal-title":"Magn Reson Imaging"},{"key":"ref41","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1162\/imag_a_00308","article-title":"Combining the benefits of 3D acquisitions and spiral readouts for VASO fMRI at UHF","volume":"2","author":"A. Monreal-Madrigal","year":"2024","journal-title":"Imaging Neurosci (Camb)"},{"key":"ref42","article-title":"Mirt: Michigan Image Reconstruction Toolbox (MIRT) - Matlab Version","author":"J. Fessler","journal-title":"Github"},{"key":"ref43","article-title":"MIRT.jl: MIRT: Michigan Image Reconstruction Toolbox (Julia Version)","author":"J. Fessler","journal-title":"Github"},{"issue":"6","key":"ref44","doi-asserted-by":"publisher","first-page":"1202","DOI":"10.1002\/mrm.10171","article-title":"Generalized autocalibrating partially parallel acquisitions (GRAPPA)","volume":"47","author":"M. A. Griswold","year":"2002","journal-title":"Magnetic Resonance in Medicine: An Official Journal of the International Society for Magnetic Resonance in Medicine"},{"key":"ref45","article-title":"MATLAB Code for Split Slice GRAPPA Recon of SMS-EPI Data","journal-title":"Github"},{"key":"ref46","article-title":"Fisher transformation","author":"Wikipedia contributors","year":"2025","journal-title":"Wikipedia, The Free Encyclopedia"},{"key":"ref47","article-title":"Open file format for MR sequences Version 1.5.1","author":"S. K. K. L. Maxim Zaitsev","year":"2025"},{"issue":"42","key":"ref48","doi-asserted-by":"publisher","first-page":"1725","DOI":"10.21105\/joss.01725","article-title":"PyPulseq: a python package for MRI pulse sequence design","volume":"4","author":"K. S. Ravi","year":"2019","journal-title":"Journal of Open Source Software"},{"issue":"1","key":"ref49","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1002\/mrm.22406","article-title":"High-performance computing MRI simulations","volume":"64","author":"T. St\u00f6cker","year":"2010","journal-title":"Magn Reson Med"},{"issue":"5","key":"ref50","doi-asserted-by":"publisher","first-page":"e0216594","DOI":"10.1371\/journal.pone.0216594","article-title":"coreMRI: A high-performance, publicly available MR simulation platform on the cloud","volume":"14","author":"C. G. Xanthis","year":"2019","journal-title":"PLoS One"},{"key":"ref51","article-title":"MATLAB Pulseq Design Toolbox","journal-title":"Medical University Freiburg"}],"container-title":["Aperture Neuro"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/apertureneuro.org\/article\/155279-a-vendor-neutral-functional-mri-acquisition-protocol-for-multi-site-studies","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,13]],"date-time":"2026-02-13T14:28:49Z","timestamp":1770992929000},"score":1,"resource":{"primary":{"URL":"https:\/\/apertureneuro.org\/article\/155279-a-vendor-neutral-functional-mri-acquisition-protocol-for-multi-site-studies"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,13]]},"references-count":51,"journal-issue":{"issue":"SI 1","published-online":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.52294\/001c.155279","relation":{},"ISSN":["2957-3963"],"issn-type":[{"value":"2957-3963","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,13]]}}}