{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,9,13]],"date-time":"2023-09-13T12:45:29Z","timestamp":1694609129314},"reference-count":36,"publisher":"Universa BV","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Acta Orthop Belg"],"published-print":{"date-parts":[[2023,6]]},"abstract":"<jats:p>This study aimed to evaluate the effect of pelvis type in percutaneous acetabular column fixation. What is the effect of pelvis type in percutaneous acetabular colon fixation? The available pelvic computed tomography (CT) scans which were obtained in the diagnostic imaging center with a 1 mm slice width were evaluated. The pelvic type was classified with the help of MPR (Multiplanar Reformat) and 3D (Three Dimensional) imaging modes. All evaluated bony pelvic structures were anatomically intact. 40 types of android, gynecoid, anthropoid, and platypelloid pelvis were determined. CT sections were created in MPR imaging mode. Anterior obturator oblique (AOO) and inlet images were created for anterior column evaluation, while iliac oblique (IO) and outlet images were created for posterior column evaluation. The possibility of obtaining a linear corridor for acetabular columns was investigated by measuring corridor width and lengthon images of pelvic CTs. A linear corridor could not be obtained between the pubic tubercle and the supraacetabular region of 12 (30%) CTs in the anterior column of gynecoid pelvis group. The diameter of the anterior column corridor was below 5.5 mm in 10 (25%) of Gynecoid pelvis group, 5 (12.5%) of Anthropoid pelvis group, and 10 of Platypelloid pelvis group, , and all those scans belonged to the female gender. There was a statistically significant difference between pelvis types in terms of anterior and posterior column diameters (p &lt;0.001). While the android pelvis type had the highest diameter and corridor length in both anterior column and posterior column measurements, the gynecoid pelvic type had the lowest diameter and corridor length. In the evaluations made according to gender, both anterior and posterior column diameters were larger and longer in males than in females (p &lt;0.001). Pelvis type is an important factor which can affect anterior and posterior column diameter and length of acetabulum. Pelvic typing before acetabular surgery can help the surgeon determining the most appropriate patient position, surgical approach, and implant selection.\n\nLevel of Evidence: Level 2..<\/jats:p>","DOI":"10.52628\/89.2.9727","type":"journal-article","created":{"date-parts":[[2023,9,12]],"date-time":"2023-09-12T14:22:09Z","timestamp":1694528529000},"page":"333-339","source":"Crossref","is-referenced-by-count":0,"title":["Evaluation of the effect of pelvis type in percutaneous acetabular column fixation: a computed tomography study"],"prefix":"10.52628","volume":"89","author":[{"given":"Harun","family":"ALTINAYAK","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yavuz Selim","family":"KARATEKIN","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ibrahim","family":"T\u00dcL\u00dcCE","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Celal","family":"BITI\u015e","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"27062","published-online":{"date-parts":[[2023,8]]},"reference":[{"key":"ref0","doi-asserted-by":"publisher","unstructured":"Attias N, Lindsey RW, Starr AJ, Borer D, Bridges K, Hipp JA. The use of a virtual three-dimensional model to evaluate the intraosseous space available for percutaneous screw fixation of acetabular fractures. J Bone Joint Surg Br 2005;87:1520-3.","DOI":"10.1302\/0301-620x.87b11.16614"},{"key":"ref1","doi-asserted-by":"publisher","unstructured":"Banaszek D, Starr AJ, Lefaivre KA. Technical considerations and fluoroscopy in percutaneous fixation of the pelvis and acetabulum, J. Am. Acad. Orthop. Surg. 2019;27: 899-908","DOI":"10.5435\/jaaos-d-18-00102"},{"key":"ref2","doi-asserted-by":"publisher","unstructured":"Bishop JA, Routt ML Jr. Osseous fixation pathways in pelvic and acetabular fracture surgery: osteology, radiology, and clinical applications. J Trauma Acute Care Surg 2012;72:1502-9.","DOI":"10.1097\/ta.0b013e318246efe5"},{"key":"ref3","doi-asserted-by":"publisher","unstructured":"Bozzio AE, Johnson CR, Mauffrey C: Short-term results of percutaneous treatment of acetabular fractures: Functional outcomes, radiographic assessment and complications. Int Orthop 2016;40:1703-8.","DOI":"10.1007\/s00264-015-2987-0"},{"key":"ref4","doi-asserted-by":"publisher","unstructured":"Briffa N, Pearce R, Hill AM, Bircher M. Outcomes of acetabular fracture fixation with ten years\u2019 follow-up. J Bone Joint Surg Br 2011;93-B:229-36","DOI":"10.1302\/0301-620x.93b2.24056"},{"key":"ref5","doi-asserted-by":"publisher","unstructured":"Caldwell WE, Moloy HC. Anatomical variations in the female pelvis: their classification and obstetrical significance. Proc R Soc Med 1938; 32:1-30.","DOI":"10.1177\/003591573803200101"},{"key":"ref6","doi-asserted-by":"publisher","unstructured":"Chen KN, Wang G, Cao LG, Zhang MC. Differences of percutaneous retrograde screw fixation of anterior column acetabular fractures between male and female: a study of 164 virtual three- dimensional models. Injury 2009; 40:1067-72","DOI":"10.1016\/j.injury.2009.01.014"},{"key":"ref7","doi-asserted-by":"publisher","unstructured":"Chen H, Wang G, Li R, Sun Y, Wang F, Zhao H, et al. A novel navigation template for fixation of acetabular posterior column fractures with antegrade lag screws: design and application. International orthopaedics 2016;40:827-34.","DOI":"10.1007\/s00264-015-2813-8"},{"key":"ref8","doi-asserted-by":"publisher","unstructured":"Ebraheim NA, Xu R, Biyani A, Benedetti JA. Anatomic basis of lag screw placement in the anterior column of the acetabulum. Clinical Orthopaedics and Related Research 1997; 339: 200-5","DOI":"10.1097\/00003086-199706000-00028"},{"key":"ref9","doi-asserted-by":"publisher","unstructured":"Gras F, Gottschling H, Schroder M, Marintschev I, Reimers N, Burgkart R. Sex-specific differences of the infraacetabular corridor: a biomorphometric CT-based analysis on a database of 523 pelves. Clin Orthop Relat Res 2015;473:361-9.","DOI":"10.1007\/s11999-014-3932-z"},{"key":"ref10","doi-asserted-by":"publisher","unstructured":"Grossterlinden L, Nuechtern J, Begemann PG, Fuhrhop I, Petersen JP, Ruecker A, et al.Computer-assisted surgery and intraoperative three-dimensional imaging for screw placement in different pelvic regions. J Trauma 2011;71:926-32","DOI":"10.1097\/ta.0b013e31820333dd"},{"key":"ref11","doi-asserted-by":"crossref","unstructured":"Jimenez ML, Vrabas MS. Surgical approaches to the acetabulum. Orthop Clin North Am 1997;28:419-34","DOI":"10.1016\/S0030-5898(05)70299-6"},{"key":"ref12","unstructured":"Judet, R. and E. Letournel, Les fractures du cotyle. 1974, Paris: Masson."},{"key":"ref13","doi-asserted-by":"publisher","unstructured":"Jung GH, Lee Y, Kim JW, Kim JW. Computational analysis of the safe zone for the antegrade lag screw in posterior column fixation with the anterior approach in acetabular fracture: a cadaveric study. Injury 2017;48:608-14.","DOI":"10.1016\/j.injury.2017.01.028"},{"key":"ref14","doi-asserted-by":"publisher","unstructured":"Kannus P, Parkkari J, Niemi S, Siev\u00e4nen H. Low-trauma pelvic fractures in elderly Finns in 1970-2013. Calcif Tissue Int 2015; 97:577-80.","DOI":"10.1007\/s00223-015-0056-8"},{"key":"ref15","doi-asserted-by":"publisher","unstructured":"Lenhard M, Johnson T, Weckbach S, Nikolaou K, Friese K, Hasbargen U. Three-dimensional pelvimetry by computed tomography. Radiol Med. 2009;114:827-34.","DOI":"10.1007\/s11547-009-0390-x"},{"key":"ref16","doi-asserted-by":"publisher","unstructured":"Levin S, Krumins R, Shaath MK, Avilucea FR. Clinical outcomes in prone positioning for percutaneous fixation of posterior column acetabular fractures. Eur J Trauma Emerg Surg 2021. https:\/\/doi.org\/10.1007\/s00068-021-01636-w","DOI":"10.1007\/s00068-021-01636-w"},{"key":"ref17","doi-asserted-by":"publisher","unstructured":"Lin YC, Chen CH, Huang HT, Chen JC, Huang PJ, Hung SH, et al. Percutaneous antegrade screwing for anterior column fracture of acetabulum with fluoroscopic-based computerized navigation. Arch Orthop Trauma Surg 2008;128:223-6","DOI":"10.1007\/s00402-007-0369-9"},{"key":"ref18","doi-asserted-by":"crossref","unstructured":"Matta JM, Mehne DK, Roffi R. Fractures of the acetabulum. Early results of a prospective study. Clin Orthop Relat Res 1986;205:241-50","DOI":"10.1097\/00003086-198604000-00030"},{"key":"ref19","doi-asserted-by":"crossref","unstructured":"Matta JM, Merritt PO. Displaced acetabular fractures. Clin Orthop Relat Res 1988;230:83-97.","DOI":"10.1097\/00003086-198805000-00009"},{"key":"ref20","doi-asserted-by":"publisher","unstructured":"Melhem E, Riouallon G, Habboubi K, Gabbas M, Jouffroy P. Epidemiology of pelvic and acetabular fractures in France. Orthop Traumatol Surg Res 2020;106: 831-9.","DOI":"10.1016\/j.otsr.2019.11.019"},{"key":"ref21","doi-asserted-by":"publisher","unstructured":"Mouhsine E, Garofalo R, Borens O, Wettstein M, Blanc CH, Fischer JF, et al. Percutaneous retrograde screwing for stabilisation of acetabular fractures. Injury 2005;36:1330-6.","DOI":"10.1016\/j.injury.2006.05.019"},{"key":"ref22","doi-asserted-by":"publisher","unstructured":"vMu WD, Wang XQ, Jia TH, Zhou DS, Cheng AX. Quantitative anatomic basis of antegrade lag screw placement in posterior column of acetabulum. Arch Orthop Trauma Surg 2009;129:1531-7","DOI":"10.1007\/s00402-009-0836-6"},{"key":"ref23","doi-asserted-by":"publisher","unstructured":"Puchwein P, Enninghorst N, Sisak K, Ortner T, Schildhauer TA, Balogh ZJ, et al. Percutaneous fixation of acetabular fractures: computer-assisted determination of safe zones, angles and lengths for screw insertion. Arch Orthop Trauma Surg 2012; 132: 805-11.","DOI":"10.1007\/s00402-012-1486-7"},{"key":"ref24","doi-asserted-by":"publisher","unstructured":"Quan Q, Hong L, Chang B, Liu R, Zhang Y, Zhao Q, Lu S. A radiographic simulation study of fixed superior pubis ramus fractures with retrograde screw insertion. J Orthop 2016;13:364-8.","DOI":"10.1016\/j.jor.2016.07.005"},{"key":"ref25","doi-asserted-by":"publisher","unstructured":"Rickman M, Varghese VD. Contemporary acetabular fracture surgery: treading water or swimming upstream? Bone Joint J 2017; 99-B(9):1125-31.","DOI":"10.1302\/0301-620x.99b9.bjj-2017-0185.r1"},{"key":"ref26","doi-asserted-by":"publisher","unstructured":"Rinne PP, Laitinen MK, Huttunen T, Kannus P, Mattila VM. The incidence and trauma mechanisms of acetabular fractures: a nationwide study in Finland between 1997 and 2014. Injury 2017; 48:2157-61","DOI":"10.1016\/j.injury.2017.08.003"},{"key":"ref27","doi-asserted-by":"crossref","unstructured":"Rommens PM. Is there a role for percutaneous pelvic and acetabular reconstruction? Injury 2007;38:463-77.","DOI":"10.1016\/j.injury.2007.01.025"},{"key":"ref28","doi-asserted-by":"publisher","unstructured":"Routt Jr ML, Simonian PT, Grujic L. The retrograde medullary superior pubic ramus screw for the treatment of anterior pelvic ring disruptions: a new technique. J Orthop Trauma 1995; 9: 35-44","DOI":"10.1097\/00005131-199502000-00006"},{"key":"ref29","doi-asserted-by":"publisher","unstructured":"Salk I, Cetin A, Salk S, Cetin M. Pelvimetry by three-dimensional computed tomography in non-pregnant multiparous women who delivered vaginally. Pol. J. Radiol 2016;81: 219-27","DOI":"10.12659\/pjr.896380"},{"key":"ref30","doi-asserted-by":"publisher","unstructured":"Shahulhameed A, Roberts CS, Pomeroy CL, Acland RD, Giannoudis PV. Mapping the columns of the acetabulum implications for percutaneous fixation. Injury 2010;41:339-42.","DOI":"10.1016\/j.injury.2009.08.004"},{"key":"ref31","doi-asserted-by":"publisher","unstructured":"Starr AJ, Reinert CM, Jones AL. Percutaneous fixation of the columns of the acetabulum: a new technique. J Orthop Trauma 1998; 12: 51-8.","DOI":"10.1097\/00005131-199801000-00009"},{"key":"ref32","doi-asserted-by":"publisher","unstructured":"Suzuki T, Soma K, Shindo M, Minehara H, Itoman M. Anatomic study for pubic medullary screw insertion. J Orthop Surg 2008; 16: 321-5","DOI":"10.1177\/230949900801600311"},{"key":"ref33","doi-asserted-by":"publisher","unstructured":"Tannast M, Najibi S, Matta JM. Two to Twenty-Year Survivorship of the Hip in 810 Patients with Operatively Treated Acetabular Fractures. J Bone Joint Surg Am 2012;94:1559-67.","DOI":"10.2106\/jbjs.k.00444"},{"key":"ref34","doi-asserted-by":"publisher","unstructured":"Yu YH, Tseng IC, Su CY, Huang JW, Wu CC. Modified technique of percutaneous posterior columnar screw insertion and neutralization plate for complex acetabular fractures. J Trauma 2011; 71:198-03.","DOI":"10.1097\/ta.0b013e3181f2d50f"},{"key":"ref35","doi-asserted-by":"publisher","unstructured":"Zhang P, Tang J, Dong Y, Lu L, Wang S, Song S, et al. A new navigational apparatus for fixation of acetabular posterior column fractures with percutaneous retrograde lagscrew. Medicine 2018;97(36):e12134.","DOI":"10.1097\/md.0000000000012134"}],"container-title":["Acta Orthopaedica Belgica"],"original-title":[],"deposited":{"date-parts":[[2023,9,12]],"date-time":"2023-09-12T14:22:14Z","timestamp":1694528534000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.actaorthopaedica.be\/archive\/volume-89\/issue-2\/original-studies\/evaluaton-of-the-effect-of-pelvis-type-in-percutaneous-acetabular-column-fixation-a-computed-tomog\/http:\/\/www.actaorthopaedica.be\/archive\/volume-89\/issue-2\/original-studies\/evaluaton-of-the-effect-of-pelvis-type-in-percutaneous-acetabular-column-fixation-a-computed-tomog\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,6]]},"references-count":36,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2023,8]]},"published-print":{"date-parts":[[2023,6,30]]}},"URL":"https:\/\/doi.org\/10.52628\/89.2.9727","relation":{},"ISSN":["0001-6462"],"issn-type":[{"value":"0001-6462","type":"print"}],"subject":[],"published":{"date-parts":[[2023,6]]}}}