{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,4,25]],"date-time":"2024-04-25T00:28:31Z","timestamp":1714004911696},"reference-count":27,"publisher":"Universa BV","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Acta Orthop Belg"],"published-print":{"date-parts":[[2024,3]]},"abstract":"<jats:p>The aim of the study was to evaluate the results of Dorsal Wrist Plating in intra-articular distal radius fractures with a dorsal displacement. In this prospective study, a single surgeon treated 20 patients with a (partially) intra-articular distal radius fracture with a dorsal rim avulsion or a dorsal Barton\u2019s type fragment. They all underwent an open reduction and internal fixation by Dorsal Wrist Plating. A total of 17 patients had a follow-up period of at least 12 months (mean follow- up of 17 months) and these patients were included in the study. Both functional and radiological outcome parameters were measured. The total range of motion was 92 % of the contralateral side. The mean grip strength and key pinch were 24.6 kg and 6.9kg respectively compared to 29.5 kg and 7.4 kg on the non-operated side. The average Mayo Wrist Score was 89.7 (range 80-100) and the mean Disability of the Arm, Shoulder and Hand score was 4.5 (range 0-9.2). An articular step-off was only noted in 2 patients (1 and 2 mm respectively). Radial inclination was restored in all patients. Palmar tilt was anatomically restored in five patients. In all other patients, the palmar tilt was acceptably restored. There was no significant radial shortening in any of the patients. No infections, no tendon ruptures, no Complex Regional Pain Syndrome, or union problems were observed. Dorsal wrist plating seems to be a safe and reliable procedure in the treatment of intra-articular distal radius fractures with dorsal displacement.<\/jats:p>","DOI":"10.52628\/90.1.8058","type":"journal-article","created":{"date-parts":[[2024,4,24]],"date-time":"2024-04-24T19:44:14Z","timestamp":1713987854000},"page":"110-114","source":"Crossref","is-referenced-by-count":0,"title":["Dorsal wrist plating for the management of intra-articular distal radius fractures"],"prefix":"10.52628","volume":"90","author":[{"given":"J","family":"BRAUNS","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"W","family":"VANDESANDE","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"27062","published-online":{"date-parts":[[2024,4]]},"reference":[{"key":"ref0","doi-asserted-by":"publisher","unstructured":"Mauck, B. M., & Swigler, C. W. Evidence-Based Review of Distal Radius Fractures. Orthopedic Clinics of North America, 2018: 49(2), 211-222.","DOI":"10.1016\/j.ocl.2017.12.001"},{"key":"ref1","doi-asserted-by":"publisher","unstructured":"Spiteri M, NG W, Matthews J et al. Three Year Review of Dorsal Plating for Complex Intra-Articular Fractures of the Distal Radius. J Hand Asian-Pac. 2018; 23: 221-226.","DOI":"10.1142\/s2424835518500248"},{"key":"ref2","doi-asserted-by":"publisher","unstructured":"Marsh JL, Slongo TF, Agel J, et al. Fracture and dislocation classification compendium - 2007: orthopaedic Trauma Association classification, database and outcomes committee. J Orthop Trauma. 2007;21(10):1-133.","DOI":"10.1097\/00005131-200711101-00001"},{"key":"ref3","doi-asserted-by":"publisher","unstructured":"Rikli DA et al. Dorsal double plate fixation of distal radial fractures. Eur J Trauma Emerg Surg. 2007 Feb;33(1):99-109","DOI":"10.1007\/s00068-007-9155-1"},{"key":"ref4","doi-asserted-by":"publisher","unstructured":"Rikli DA, Regazzoni P. Fractures of the distal end of the radius treated by internal fixation and early function. A preliminary report of 20 cases. J. Bone Joint Surg. Br. 1996 Jul;78(4):588- 92.","DOI":"10.1302\/0301-620x.78b4.0780588"},{"key":"ref5","doi-asserted-by":"publisher","unstructured":"Medoff, R. J. Essential Radiographic Evaluation for Distal Radius Fractures. Hand Clinics, 2005; 21(3), 279-288.","DOI":"10.1016\/j.hcl.2005.02.008"},{"key":"ref6","doi-asserted-by":"publisher","unstructured":"Anzarut, A., Johnson, J. A., Rowe, B. H., et al. Radiologic and patient-reported functional outcomes in an elderly cohort with conservatively treated distal radius fractures. The Journal of Hand Surgery. 2004; 29(6), 1121-1127.","DOI":"10.1016\/j.jhsa.2004.07.002"},{"key":"ref7","doi-asserted-by":"publisher","unstructured":"Rhee PC, Alexander YS. Management of Complex Distal Radius Fractures: Review of Treatment Principles and Select Surgical Techniques. The journal of hand surgery. 2016; 21(2):140-154.","DOI":"10.1142\/s2424835516400063"},{"key":"ref8","doi-asserted-by":"publisher","unstructured":"Peine R, Rikli DA, Hoffmann R, et al. Comparison of Three Different Plating Techniques of the Distal Radius: A Biomechanical Study. The journal of hand surgery. 2000; 25(A): 29-33.","DOI":"10.1053\/jhsu.2000.jhsu025a0029"},{"key":"ref9","doi-asserted-by":"publisher","unstructured":"Lutsky K., McKeon K., Goldfarb C., et al. Dorsal Fixation of Intra-articular Distal Radius Fractures Using 2.4-mm Locking Plates. Techniques in Hand & Upper Extremity Surgery. 2009; 13,4.","DOI":"10.1097\/bth.0b013e3181c15de2"},{"key":"ref10","doi-asserted-by":"publisher","unstructured":"Yangyang R, Melvin C, Shervin Tabrizi, et al. Complications of Low-Profile Dorsal Versus Volar Locking Plates in the Distal Radius: A Comparative Study. The journal of hand surgery. 2011. 36: 1135-1141.","DOI":"10.1016\/j.jhsa.2011.04.004"},{"key":"ref11","doi-asserted-by":"publisher","unstructured":"Gajados R, Bozik M, Stranak P. Is an implant removal after dorsal plating of distal radius fracture always needed? Bratisl Lek Listy. 2015; 116(6): 357-362.","DOI":"10.4149\/bll_2015_068"},{"key":"ref12","doi-asserted-by":"publisher","unstructured":"Kamath, A. F., Zurakowski, D., Day, C. S. Low-Profile Dorsal Plating for Dorsally Angulated Distal Radius Fractures: An Outcomes Study. The Journal of Hand Surgery, 2006; 31(7), 1061-1067.","DOI":"10.1016\/j.jhsa.2006.05.008"},{"key":"ref13","doi-asserted-by":"publisher","unstructured":"Simic, P. M., Robison, J., Gardner, M. J, et al. Treatment of Distal Radius Fractures With a Low-Profile Dorsal Plating System: An Outcomes Assessment. The Journal of Hand Surgery, 2006; 31(3), 382-386.","DOI":"10.1016\/j.jhsa.2005.10.016"},{"key":"ref14","doi-asserted-by":"publisher","unstructured":"Fernandez Baca F., Benrahho J. Traitement des fractures du radius distal \u00e0 d\u00e9placement post\u00e9rieur avec double plaque dorsale: \u00e0 propos de 12 cas. Chirurgie de La Main, 2006; 25(1), 27-32.","DOI":"10.1016\/j.main.2005.12.006"},{"key":"ref15","doi-asserted-by":"publisher","unstructured":"Matzon, J. L., Kenniston, J., Beredjiklian, P. K. Hardware- Related Complications After Dorsal Plating for Displaced Distal Radius Fractures. Orthopedics, 2014; 37(11), e978-e982.","DOI":"10.3928\/01477447-20141023-54"},{"key":"ref16","doi-asserted-by":"publisher","unstructured":"De Smet A et al. Dorsal approach and internal fixation of impacted intra-articular distal radius fractures with 2.4mm locking plates. Hand Surg Rehab. 2016.","DOI":"10.1016\/j.hansur.2016.01.006"},{"key":"ref17","doi-asserted-by":"publisher","unstructured":"Hamada Y, Gotani H, Hibino N et al. Surgical Strategy and Techniques for Low-Profile Plating in Treating Dorsally Displaced Unstable Distal Radius Fractures. J Wrist Surg. 2017; 6: 163-169.","DOI":"10.1055\/s-0036-1593763"},{"key":"ref18","doi-asserted-by":"publisher","unstructured":"Shauver MJ, Chang KW, Chung KC. Contribution of functional parameters to patient-rated outcomes after surgical treatment of distal radius fractures. J Hand Surg Am. 2014; 39(3):436-42.","DOI":"10.1016\/j.jhsa.2013.11.015"},{"key":"ref19","doi-asserted-by":"crossref","unstructured":"Nazar MA, Masingh R, Bassi RS et al. Is there a consensus in the management of distal radius fractures? Open Orthop Journal. 2009; 3: 96-99.","DOI":"10.2174\/1874325000903010096"},{"key":"ref20","doi-asserted-by":"publisher","unstructured":"Peine R, Rikli D, Hoffmann R et al. Comparison of three different plating techniques for the dorsum of the distal radius. J Hand Surg. 2000; 25:29-33.","DOI":"10.1053\/jhsu.2000.jhsu025a0029"},{"key":"ref21","unstructured":"Slutsky DJ. Outcomes assessment in wrist surgery. J Wrist Surg. 2013 Feb;2(1):1-4."},{"key":"ref22","unstructured":"De Smet L. The DASH questionnaire and score in the evaluation of hand and wrist disorders. Acta Orthop Belg. 2008 Oct;74(5):575-81."},{"key":"ref23","doi-asserted-by":"publisher","unstructured":"Herron M, Faraj A, Craigen MA. Dorsal plating for displaced intra-articular fractures of the distal radius. Injury. 2003 Jul;34(7):497-502.","DOI":"10.1016\/s0020-1383(02)00190-0"},{"key":"ref24","doi-asserted-by":"publisher","unstructured":"Alter TH, Sandrowski K, Gallant G, Kwok M, Ilyas AM. Complications of Volar Plating of Distal Radius Fractures: A Systematic Review. J Wrist Surg. 2019 Jun;8(3):255-262.","DOI":"10.1055\/s-0038-1667304"},{"key":"ref25","unstructured":"Chen HQ, Wen XL, Li YM, Wen CY. [Case-control study on T-shaped locking internal fixation and external fixation for the treatment of dorsal Barton\u2019s fracture]. Zhongguo Gu Shang. 2015 Jun;28(6):517-20."},{"key":"ref26","doi-asserted-by":"publisher","unstructured":"Bhashyam AR, Fernandez DL, Fernandez dell\u2019Oca A, Jupiter JB. Dorsal Barton fracture is a variation of dorsal radiocarpal dislocation: a clinical study. J Hand Surg Eur. 2019 Dec;44(10):1065-1071.","DOI":"10.1177\/1753193419872639"}],"container-title":["Acta Orthopaedica Belgica"],"original-title":[],"deposited":{"date-parts":[[2024,4,24]],"date-time":"2024-04-24T19:44:22Z","timestamp":1713987862000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.actaorthopaedica.be\/archive\/volume-90\/issue-1\/original-studies\/dorsal-wrist-plating-for-the-management-of-intra-articular-distal-radius-fractures\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,3]]},"references-count":27,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,4]]},"published-print":{"date-parts":[[2024,3]]}},"URL":"https:\/\/doi.org\/10.52628\/90.1.8058","relation":{},"ISSN":["0001-6462"],"issn-type":[{"value":"0001-6462","type":"print"}],"subject":[],"published":{"date-parts":[[2024,3]]}}}