{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,2]],"date-time":"2026-09-02T02:10:42Z","timestamp":1788315042059,"version":"build-2803163510"},"reference-count":26,"publisher":"Open Medical Publishing","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"abstract":"<jats:sec id=\"introduction\">\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>Proximal femoral fractures (PFF) are a significant health concern among the elderly, often leading to complications and high mortality rates. Intramedullary nailing is widely considered the most effective treatment for lateral proximal femoral fractures (LPFF), with the Tip Apex Distance (TAD) being a crucial predictor of surgical success. This study aimed to compare outcomes between patients treated with and without the ADAPT (ADAptive Positioning Technology) system, which aids in the precise placement of the cephalic screw.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"materials-and-methods\">\n                    <jats:title>Materials and Methods<\/jats:title>\n                    <jats:p>A retrospective analysis was conducted on 97 patients with intertrochanteric fractures treated in 2022. Patients were divided into two groups: those treated with the ADAPT system (group I, n=34) and those treated without it (group II, n=63). Fractures were classified according to AO\/OTA classification. The primary outcomes measured were operative time, cephalic screw angle, TAD, and incidence of lag screw cut-out. Statistical analyses included chi-square tests and t-tests, with significance set at P &lt; 0.05.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"results\">\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The ADAPT system did not significantly reduce TAD (18.21 mm in the ADAPT group vs.\u00a019.94 mm in the control group, p=0.149). Operative times were similar between the groups. The incidence of lag screw cut-out was low in both groups, with no significant differences. The study confirmed a strong correlation between higher TAD and increased risk of screw cut-out, underscoring the importance of precise screw placement.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"discussion\">\n                    <jats:title>Discussion<\/jats:title>\n                    <jats:p>Computer-assisted surgery, such as the ADAPT system, aims to enhance the accuracy of cephalic screw placement. In this study, the ADAPT system didn\u2019t demonstrate a statistically significant advantage in reducing TAD or preventing screw cut-out. Nevertheless, the critical role of TAD in preventing fixation failure was reaffirmed, emphasising the need for precise surgical techniques.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"conclusion\">\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>While the ADAPT system did not show a significant advantage in reducing TAD or preventing screw cut-out in this study, the importance of achieving optimal TAD in cephalomedullary nailing was reinforced. Future research should continue to explore the role of computer-assisted systems in enhancing surgical accuracy and improving outcomes for patients with LPFF.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.52965\/001c.121094","type":"journal-article","created":{"date-parts":[[2024,7,16]],"date-time":"2024-07-16T21:05:25Z","timestamp":1721163925000},"source":"Crossref","is-referenced-by-count":2,"title":["One year \u201cADAPT system\u201d use for proximal femoral fracture osteosynthesis with intramedullary nail . A case control study."],"prefix":"10.52965","volume":"16","author":[{"given":"Michele Dario","family":"Gurz\u00ec","sequence":"first","affiliation":[{"id":[{"id":"https:\/\/ror.org\/00enq8e33","id-type":"ROR","asserted-by":"publisher"}],"name":"Aurelia Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luigi","family":"Cianni","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/00rg70c39","id-type":"ROR","asserted-by":"publisher"}],"name":"Agostino Gemelli University Polyclinic","department":["Department of Aging, Orthopaedic and Rheumatological Sciences"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1230-9537","authenticated-orcid":true,"given":"Giovan Giuseppe","family":"Mazzella","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/00rg70c39","id-type":"ROR","asserted-by":"publisher"}],"name":"Agostino Gemelli University Polyclinic","department":["Department of Aging, Orthopaedic and Rheumatological Sciences"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sara","family":"Calori","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/00rg70c39","id-type":"ROR","asserted-by":"publisher"}],"name":"Agostino Gemelli University Polyclinic","department":["Department of Aging, Orthopaedic and Rheumatological Sciences"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eugenio","family":"Libutti","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/00enq8e33","id-type":"ROR","asserted-by":"publisher"}],"name":"Aurelia Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raffaele","family":"Vitiello","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/00rg70c39","id-type":"ROR","asserted-by":"publisher"}],"name":"Agostino Gemelli University Polyclinic","department":["Department of Aging, Orthopaedic and Rheumatological Sciences"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giulio","family":"Maccauro","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/00rg70c39","id-type":"ROR","asserted-by":"publisher"}],"name":"Agostino Gemelli University Polyclinic","department":["Department of Aging, Orthopaedic and Rheumatological Sciences"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Massimiliano","family":"Nannerini","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/00enq8e33","id-type":"ROR","asserted-by":"publisher"}],"name":"Aurelia Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"30777","published-online":{"date-parts":[[2024,7,17]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","first-page":"427","DOI":"10.1097\/01.ta.0000239255.47280.6f","article-title":"Surgical treatment of basicervical fractures of femur\u2013a prospective evaluation of 269 patients","volume":"64","author":"C. Y. Chen","year":"2008","journal-title":"J Trauma"},{"key":"ref2","first-page":"256","article-title":"Basicervical fractures of the proximal femur. A biomechanical study of 3 internal fixation techniques","volume":"306","author":"B. Blair","year":"1994","journal-title":"Clin Orthop Relat Res"},{"issue":"4","key":"ref3","doi-asserted-by":"publisher","first-page":"502","DOI":"10.1093\/intqhc\/mzw055","article-title":"Impact of antibiotic stewardship on perioperative antimicrobial prophylaxis","volume":"28","author":"R. Murri","year":"2016","journal-title":"Int J Qual Health Care"},{"issue":"5","key":"ref4","doi-asserted-by":"publisher","first-page":"247","DOI":"10.5435\/00124635-201005000-00001","article-title":"Computer-assisted trauma surgery","volume":"18","author":"K. Atesok","year":"2010","journal-title":"J Am Acad Orthop Surg"},{"key":"ref5","doi-asserted-by":"publisher","first-page":"387","DOI":"10.2106\/00004623-199503000-00008","article-title":"Age-related reductions in strength of the femur tested in a fall loading configuration","volume":"77","author":"A., et al. Courtney","year":"1995","journal-title":"J. Bone Jt Surg"},{"issue":"10","key":"ref6","doi-asserted-by":"publisher","first-page":"994","DOI":"10.1016\/j.injury.2003.10.028","article-title":"Prediction of fixation failure after sliding hip screw fixation","volume":"35","author":"H. Pervez","year":"2004","journal-title":"Injury"},{"issue":"1","key":"ref7","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1002\/rcs.231","article-title":"Computer-assisted surgery for dynamic hip screw, using Surgix, a novel intraoperative guiding system","volume":"5","author":"A. Herman","year":"2009","journal-title":"Int J Med Robot"},{"issue":"8","key":"ref8","doi-asserted-by":"publisher","first-page":"1273","DOI":"10.1007\/s00264-009-0866-2","article-title":"Risk factors in cutout of sliding hip screw in intertrochanteric fractures: an evaluation of 937 patients","volume":"34","author":"K. K. Hsueh","year":"2010","journal-title":"Int Orthop"},{"issue":"6","key":"ref9","doi-asserted-by":"publisher","first-page":"1149","DOI":"10.1016\/j.injury.2018.03.014","article-title":"Accuracy analysis of computer-assisted surgery for femoral trochanteric fracture using a fluoroscopic navigation system: Stryker ADAPT\u00ae system","volume":"49","author":"H. Takai","year":"2018","journal-title":"Injury"},{"key":"ref10","first-page":"206","article-title":"Correct placement of the screw or nail in trochanteric fractures. Effect of the initial placement in the migration","volume":"313","author":"I. A. Galanakis","year":"1995","journal-title":"Clin Orthop Relat Res"},{"key":"ref11","doi-asserted-by":"publisher","first-page":"1507","DOI":"10.1007\/s00198-016-3894-y","article-title":"Mind the (treatment) gap: A global perspective on current and future strategies for prevention of fragility fractures","volume":"28","author":"N. C. W. Harvey","year":"2017","journal-title":"Osteoporos. Int."},{"issue":"7","key":"ref12","doi-asserted-by":"publisher","first-page":"785","DOI":"10.1016\/j.injury.2007.03.010","article-title":"Anterior or posterior obliquity of the lag screw in the lateral view--does it affect the sliding characteristics on unstable trochanteric fractures?","volume":"38","author":"S. Y. Park","year":"2007","journal-title":"Injury"},{"issue":"11","key":"ref13","doi-asserted-by":"publisher","first-page":"2347","DOI":"10.1007\/s00264-012-1636-0","article-title":"Tip apex distance, hip screw placement, and neck shaft angle as potential risk factors for cut-out failure of hip screws after surgical treatment of intertrochanteric fractures","volume":"36","author":"H., et al. Andruszkow","year":"2012","journal-title":"Int Orthop"},{"issue":"5","key":"ref14","doi-asserted-by":"publisher","first-page":"719","DOI":"10.1007\/s00264-009-0837-7","article-title":"Tip-apex distance of intramedullary devices as a predictor of cut-out failure in the treatment of peritrochanteric elderly hip fractures","volume":"34","author":"J. A., et al. Geller","year":"2010","journal-title":"Int Orthop"},{"key":"ref15","doi-asserted-by":"publisher","first-page":"2151459320979975","DOI":"10.1177\/2151459320979975","article-title":"Outcomes of U-Blade Lag Screw for Cephalomedullary Fixation of Unstable Trochanteric Femur Fractures: A Case Control Study","volume":"11","author":"J.S. Kang","year":"2020","journal-title":"Geriatr Orthop Surg Rehabil"},{"issue":"2018","key":"ref16","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2018\/7618079","article-title":"Biomechanical comparison of three different intramedullary nails for fixation of unstable basicervical intertrochanteric fractures of the proximal femur: experimental studies","volume":"2018","author":"D. K. Kwak","journal-title":"Biomed Res Int"},{"key":"ref17","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1051\/sicotj\/2021056","article-title":"ADAPT system is a dramatic advance in computer-assisted surgery for femoral trochanteric fractures","volume":"7","author":"T. Murakami","year":"2021","journal-title":"SICOT J"},{"issue":"3","key":"ref18","doi-asserted-by":"publisher","first-page":"744","DOI":"10.1016\/j.injury.2019.02.010","article-title":"Optimising the tip-apex-distance in trochanteric femoral fracture fixation using the ADAPT-navigated technique, a longitudinal matched cohort study","volume":"50","author":"J. Herzog","year":"2019","journal-title":"Injury"},{"issue":"1","key":"ref19","doi-asserted-by":"publisher","first-page":"15","DOI":"10.4103\/0019-5413.73656","article-title":"Epidemiology of hip fracture: Worldwide geographic variation","volume":"45","author":"D. K. Dhanwal","year":"2011","journal-title":"Indian J Orthop"},{"issue":"S2","key":"ref20","doi-asserted-by":"publisher","first-page":"e2023047","DOI":"10.23750\/abm.v94iS2.12572","article-title":"Predictor of hip fracture type: a systematic review","volume":"94","author":"M. R. Matrangolo","year":"2023","journal-title":"Acta Biomed"},{"issue":"1","key":"ref21","doi-asserted-by":"publisher","first-page":"449","DOI":"10.1186\/s13018-019-1506-1","article-title":"Intramedullary nailing for pertrochanteric fractures of proximal femur: a consecutive series of 323 patients treated with two devices","volume":"14","author":"P. Catania","year":"2019","journal-title":"J Orthop Surg Res"},{"issue":"1","key":"ref22","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/1471-2474-14-1","article-title":"Critical factors in cut-out complication after Gamma Nail treatment of proximal femoral fractures","volume":"14","author":"A. J. Bojan","year":"2013","journal-title":"BMC Musculoskelet Disord"},{"issue":"7","key":"ref23","doi-asserted-by":"publisher","first-page":"1058","DOI":"10.2106\/00004623-199507000-00012","article-title":"The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip","volume":"77","author":"M. R. Baumgaertner","year":"1995","journal-title":"J Bone Joint Surg Am"},{"issue":"5","key":"ref24","doi-asserted-by":"publisher","first-page":"719","DOI":"10.1007\/s00264-009-0837-7","article-title":"Tip-apex distance of intramedullary devices as a predictor of cut-out failure in the treatment of peritrochanteric elderly hip fractures","volume":"34","author":"J. A. Geller","year":"2010","journal-title":"Int Orthop"},{"issue":"Suppl. 10","key":"ref25","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1097\/00005131-200711101-00001","article-title":"Fracture and dislocation classification compendium \u2013 2007: orthopaedic trauma association classification, database and outcomes committee","volume":"21","author":"J. L. Marsh","year":"2007","journal-title":"J Orthop Trauma"},{"key":"ref26","doi-asserted-by":"publisher","first-page":"1097","DOI":"10.2106\/JBJS.15.01093","article-title":"Outcomes of low-energy basicervical proximal femoral fractures treated with cephalomedullary fixation","volume":"98","author":"S.T. Watson","year":"2016","journal-title":"J Bone Joint Surg Am"}],"container-title":["Orthopedic Reviews"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/orthopedicreviews.openmedicalpublishing.org\/article\/121094-one-year-adapt-system-use-for-proximal-femoral-fracture-osteosynthesis-with-intramedullary-nail-a-case-control-study","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,2,11]],"date-time":"2025-02-11T15:03:55Z","timestamp":1739286235000},"score":1,"resource":{"primary":{"URL":"https:\/\/orthopedicreviews.openmedicalpublishing.org\/article\/121094-one-year-adapt-system-use-for-proximal-femoral-fracture-osteosynthesis-with-intramedullary-nail-a-case-control-study"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7,17]]},"references-count":26,"URL":"https:\/\/doi.org\/10.52965\/001c.121094","relation":{},"ISSN":["2035-8164"],"issn-type":[{"value":"2035-8164","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,7,17]]}}}