{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T15:08:08Z","timestamp":1785424088945,"version":"3.56.0"},"reference-count":24,"publisher":"Open Medical Publishing","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"abstract":"<jats:sec id=\"objective\">\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>Spinal Cord Stimulation (SCS) is a vital treatment for chronic intractable pain. In the last few years, the field has undergone dramatic changes in new waveform and frequency introduction as well as device miniaturization. It is important to understand contemporary practice patterns regarding these parameters.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"methods\">\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>We surveyed the active membership of Spine Intervention Society (SIS), and American Society of Regional Anesthesia (ASRA) on their practices regarding various aspects of Spinal Cord Stimulation therapy. Here we report on SCS waveform usage, battery types, and causes of explant in this cohort of providers.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"results\">\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>There was similar degree of usage of tonic, burst, and 10 kHz usage at 71.5%, 74.1% and 61.7% respectively. Dorsal root ganglion stimulation was used by 32.6% and other modes of stimulation by 13.5%. Rechargeable systems were often or always used by 67.2% whereas 10% never used a rechargeable system. Most common cause of explant was loss of effectiveness, reported by 53.7%.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"conclusion\">\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>There has been significant adoption of new waveforms in daily practice of spinal cord stimulation therapy and there is robust mixed usage of new waveforms and frequencies. Rechargeable systems are the most commonly used but primary cell is also used in significant numbers. Loss of efficacy remains the most common cause of explant for the majority of practitioners. This survey establishes practice patterns of SCS usage regarding these important variables against which future changes can be gauged.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.52965\/001c.39648","type":"journal-article","created":{"date-parts":[[2022,11,12]],"date-time":"2022-11-12T12:12:32Z","timestamp":1668255152000},"source":"Crossref","is-referenced-by-count":13,"title":["A Survey on the Choice of Spinal Cord Stimulation Parameters and Implantable Pulse Generators and on Reasons for Explantation"],"prefix":"10.52965","volume":"14","author":[{"given":"Jatinder S","family":"Gill","sequence":"first","affiliation":[{"name":"Beth Israel Deaconess Medical Center, Department of Anesthesia, Critical Care, and Pain Medicine, Harvard Medical School, Boston, MA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lynn R","family":"Kohan","sequence":"additional","affiliation":[{"name":"University of Virginia Medical Center, Department of Anesthesia, Critical Care, and Pain Medicine, Charlottesville, VA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jamal","family":"Hasoon","sequence":"additional","affiliation":[{"name":"Beth Israel Deaconess Medical Center, Department of Anesthesia, Critical Care, and Pain Medicine, Harvard Medical School, Boston, MA"},{"name":"UTHealth McGovern Medical School, Department of Anesthesia and Pain Medicine, Houston, TX"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ivan","family":"Urits","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/01mgpsx86","id-type":"ROR","asserted-by":"publisher"}],"name":"SouthCoast Health"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Omar","family":"Viswanath","sequence":"additional","affiliation":[{"name":"Louisiana State University Health Shreveport, Department of Anesthesiology, Shreveport, LA"},{"name":"Valley Anesthesiology and Pain Consultants, Envision Physician Services, Phoenix, AZ"},{"name":"University of Arizona College of Medicine Phoenix, Department of Anesthesiology, Phoenix, AZ"},{"name":"Creighton University School of Medicine, Department of Anesthesiology, Omaha, NE"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Viet L","family":"Cai","sequence":"additional","affiliation":[{"name":"Beth Israel Deaconess Medical Center, Department of Anesthesia, Critical Care, and Pain Medicine, Harvard Medical School, Boston, MA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cyrus","family":"Yazdi","sequence":"additional","affiliation":[{"name":"Beth Israel Deaconess Medical Center, Department of Anesthesia, Critical Care, and Pain Medicine, Harvard Medical School, Boston, MA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Musa M","family":"Aner","sequence":"additional","affiliation":[{"name":"Dartmouth-Hitchcock Medical Center, Department of Anesthesia, Critical Care, and Pain Medicine, Dartmouth Medical School, Lebanon, NH"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alan D","family":"Kaye","sequence":"additional","affiliation":[{"name":"Louisiana State University Health Shreveport, Department of Anesthesiology, Shreveport, LA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas T","family":"Simopoulos","sequence":"additional","affiliation":[{"name":"Beth Israel Deaconess Medical Center, Department of Anesthesia, Critical Care, and Pain Medicine, Harvard Medical School, Boston, MA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"30777","published-online":{"date-parts":[[2022,11,12]]},"reference":[{"key":"ref1","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1111\/pme.12294","article-title":"Sustained effectiveness of 10kHz high-frequency spinal cord stimulation for patients with chronic, low back pain: 24-month results of a prospective multicenter study","volume":"15","author":"A. Al-Kaisy","year":"2014","journal-title":"Pain Med"},{"issue":"1","key":"ref2","doi-asserted-by":"publisher","first-page":"59\u201365; discussion 65\u20136","DOI":"10.1111\/ner.12006","article-title":"High-frequency spinal cord stimulation for the treatment of chronic back pain patients: Results of a prospective multicenter European clinical study","volume":"16","author":"Jean-Pierre Van Buyten","year":"2013","journal-title":"Neuromodulation: Technology at the Neural Interface","ISSN":"https:\/\/id.crossref.org\/issn\/1094-7159","issn-type":"print"},{"issue":"2","key":"ref3","doi-asserted-by":"publisher","first-page":"1719","DOI":"10.1007\/s40122-021-00332-2","article-title":"Percutaneous Spinal Cord Stimulation Lead Placement Under Deep Sedation and General Anesthesia","volume":"10","author":"Jamal Hasoon","year":"2021","journal-title":"Pain and Therapy","ISSN":"https:\/\/id.crossref.org\/issn\/2193-8237","issn-type":"print"},{"key":"ref4","doi-asserted-by":"publisher","first-page":"873","DOI":"10.2147\/jpr.s244084","article-title":"10 kHz Spinal Cord Stimulation for Combined Alleviation of Post-Laminectomy Syndrome and Chronic Abdominal Pain: A Case Report","volume":"13","author":"Amnon A Berger","year":"2020","journal-title":"Journal of Pain Research","ISSN":"https:\/\/id.crossref.org\/issn\/1178-7090","issn-type":"print"},{"key":"ref5","doi-asserted-by":"crossref","first-page":"e00171","DOI":"10.1016\/j.crwh.2020.e00171","article-title":"Spinal cord stimulation for the treatment of chronic pelvic pain after Tarlov cyst surgery in a 66-year-old woman: A case report","volume":"25","author":"J. Hasoon","year":"2020","journal-title":"Case Rep Womens Health"},{"issue":"4","key":"ref6","first-page":"331","article-title":"Paresthesia-Independence: An Assessment of Technical Factors Related to 10 kHz Paresthesia-Free Spinal Cord Stimulation","volume":"20","author":"G De Carolis","year":"2017","journal-title":"Pain Physician"},{"issue":"8","key":"ref7","first-page":"1534","article-title":"Spinal Cord Stimulation (SCS) with Anatomically Guided (3D) Neural Targeting Shows Superior Chronic Axial Low Back Pain Relief Compared to Traditional SCS-LUMINA Study","volume":"18","author":"E. Veizi","year":"2017","journal-title":"Pain Med"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1177\/1744806920918057","article-title":"Modulation of neuroglial interactions using differential target multiplexed spinal cord stimulation in an animal model of neuropathic pain","volume":"16","author":"Ricardo Vallejo","year":"2020","journal-title":"Molecular Pain","ISSN":"https:\/\/id.crossref.org\/issn\/1744-8069","issn-type":"print"},{"issue":"2","key":"ref9","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1016\/s1474-4422(19)30414-4","article-title":"Long-term safety and efficacy of closed-loop spinal cord stimulation to treat chronic back and leg pain (Evoke): a double-blind, randomised, controlled trial","volume":"19","author":"Nagy Mekhail","year":"2020","journal-title":"The Lancet Neurology","ISSN":"https:\/\/id.crossref.org\/issn\/1474-4422","issn-type":"print"},{"issue":"1","key":"ref10","doi-asserted-by":"publisher","first-page":"e113089","DOI":"10.5812\/aapm.113089","article-title":"Improved Pain Control with Combination Spinal Cord Stimulator Therapy Utilizing Sub-perception and Traditional Paresthesia Based Waveforms: A Pilot Study","volume":"11","author":"Amnon A. Berger","year":"2021","journal-title":"Anesthesiology and Pain Medicine","ISSN":"https:\/\/id.crossref.org\/issn\/2228-7523","issn-type":"print"},{"key":"ref11","doi-asserted-by":"crossref","first-page":"330\u2013335, discussion 335\u2013336","DOI":"10.1111\/j.1525-1403.2011.00371.x","article-title":"Spinal cord stimulation versus re-operation in patients with failed back surgery syndrome: an international multicenter randomized controlled trial (EVIDENCE study)","volume":"14","author":"R.B. North","year":"2011","journal-title":"Neuromodulation"},{"key":"ref12","doi-asserted-by":"crossref","first-page":"883","DOI":"10.1136\/rapm-2020-101681","article-title":"Explant rates of electrical neuromodulation devices in 1,177 patients in a single center over an 11 year period","volume":"45","author":"A. Al-Kaisy","year":"2020","journal-title":"Reg Anesth Pain Med"},{"issue":"7","key":"ref13","doi-asserted-by":"publisher","first-page":"845","DOI":"10.1111\/papr.12682","article-title":"The Long-Term Durability of Multilumen Concentric Percutaneous Spinal Cord Stimulator Leads","volume":"18","author":"Thomas Simopoulos","year":"2018","journal-title":"Pain Practice","ISSN":"https:\/\/id.crossref.org\/issn\/1530-7085","issn-type":"print"},{"issue":"1","key":"ref14","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1111\/ner.12565","article-title":"The Neurostimulation Appropriateness Consensus Committee (NACC) Recommendations for Infection Prevention and Management","volume":"20","author":"Timothy R. Deer","year":"2017","journal-title":"Neuromodulation: Technology at the Neural Interface","ISSN":"https:\/\/id.crossref.org\/issn\/1094-7159","issn-type":"print"},{"issue":"5","key":"ref15","doi-asserted-by":"publisher","first-page":"e120611","DOI":"10.5812\/aapm.120611","article-title":"Antibiotics for Spinal Cord Stimulation Trials and Implants: A Survey Analysis of Practice Patterns","volume":"11","author":"Syena Sarrafpour","year":"2021","journal-title":"Anesthesiology and Pain Medicine","ISSN":"https:\/\/id.crossref.org\/issn\/2228-7523","issn-type":"print"},{"issue":"6","key":"ref16","doi-asserted-by":"publisher","first-page":"571","DOI":"10.1111\/ner.12206","article-title":"The appropriate use of neurostimulation: avoidance and treatment of complications of neurostimulation therapies for the treatment of chronic pain","volume":"17","author":"Timothy R. Deer","year":"2014","journal-title":"Neuromodulation: Technology at the Neural Interface","ISSN":"https:\/\/id.crossref.org\/issn\/1094-7159","issn-type":"print"},{"issue":"1","key":"ref17","doi-asserted-by":"publisher","first-page":"179","DOI":"10.1016\/j.pain.2007.07.028","article-title":"Spinal cord stimulation versus conventional medical management for neuropathic pain: a multicentre randomised controlled trial in patients with failed back surgery syndrome","volume":"132","author":"Krishna Kumar","year":"2007","journal-title":"Pain","ISSN":"https:\/\/id.crossref.org\/issn\/0304-3959","issn-type":"print"},{"issue":"4","key":"ref18","doi-asserted-by":"publisher","first-page":"851","DOI":"10.1097\/aln.0000000000000774","article-title":"Novel 10-kHz high-frequency therapy (HF10 therapy) is superior to traditional low-frequency spinal cord stimulation for the treatment of chronic back and leg pain: the SENZA-RCT randomized controlled trial","volume":"123","author":"Leonardo Kapural","year":"2015","journal-title":"Anesthesiology","ISSN":"https:\/\/id.crossref.org\/issn\/0003-3022","issn-type":"print"},{"issue":"4","key":"ref19","doi-asserted-by":"publisher","first-page":"669","DOI":"10.1097\/j.pain.0000000000000814","article-title":"Dorsal root ganglion stimulation yielded higher treatment success rate for complex regional pain syndrome and causalgia at 3 and 12 months: a randomized comparative trial","volume":"158","author":"Timothy R. Deer","year":"2017","journal-title":"Pain","ISSN":"https:\/\/id.crossref.org\/issn\/0304-3959","issn-type":"print"},{"issue":"1","key":"ref20","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1111\/ner.12698","article-title":"Success Using Neuromodulation With BURST (SUNBURST) Study: Results From a Prospective, Randomized Controlled Trial Using a Novel Burst Waveform","volume":"21","author":"Timothy Deer","year":"2018","journal-title":"Neuromodulation: Technology at the Neural Interface","ISSN":"https:\/\/id.crossref.org\/issn\/1094-7159","issn-type":"print"},{"issue":"6","key":"ref21","doi-asserted-by":"publisher","first-page":"543","DOI":"10.1111\/ner.12634","article-title":"Multicenter Retrospective Study of Neurostimulation With Exit of Therapy by Explant","volume":"20","author":"Jason E. Pope","year":"2017","journal-title":"Neuromodulation: Technology at the Neural Interface","ISSN":"https:\/\/id.crossref.org\/issn\/1094-7159","issn-type":"print"},{"issue":"7","key":"ref22","doi-asserted-by":"publisher","first-page":"1355","DOI":"10.1093\/pm\/pny245","article-title":"Explantation of Percutaneous Spinal Cord Stimulator Devices: A Retrospective Descriptive Analysis of a Single-Center 15-Year Experience","volume":"20","author":"Thomas Simopoulos","year":"2019","journal-title":"Pain Med","ISSN":"https:\/\/id.crossref.org\/issn\/1526-2375","issn-type":"print"},{"issue":"7","key":"ref23","doi-asserted-by":"publisher","first-page":"603","DOI":"10.1111\/ner.12312","article-title":"Treatment-limiting complications of percutaneous spinal cord stimulator implants: A review of eight years of experience from an academic center database","volume":"18","author":"Salim M. Hayek","year":"2015","journal-title":"Neuromodulation: Technology at the Neural Interface","ISSN":"https:\/\/id.crossref.org\/issn\/1094-7159","issn-type":"print"},{"issue":"6","key":"ref24","doi-asserted-by":"publisher","first-page":"589","DOI":"10.1111\/ner.12587","article-title":"A spinal cord stimulation service review from a single center using a single manufacturer over a 7.5 year follow up period","volume":"20","author":"Simon J. Thomson","year":"2017","journal-title":"Neuromodulation: Technology at the Neural Interface","ISSN":"https:\/\/id.crossref.org\/issn\/1094-7159","issn-type":"print"}],"container-title":["Orthopedic Reviews"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/orthopedicreviews.openmedicalpublishing.org\/article\/39648-a-survey-on-the-choice-of-spinal-cord-stimulation-parameters-and-implantable-pulse-generators-and-on-reasons-for-explantation","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,2,11]],"date-time":"2025-02-11T15:09:22Z","timestamp":1739286562000},"score":1,"resource":{"primary":{"URL":"https:\/\/orthopedicreviews.openmedicalpublishing.org\/article\/39648-a-survey-on-the-choice-of-spinal-cord-stimulation-parameters-and-implantable-pulse-generators-and-on-reasons-for-explantation"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,11,12]]},"references-count":24,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.52965\/001c.39648","relation":{},"ISSN":["2035-8164"],"issn-type":[{"value":"2035-8164","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,11,12]]}}}