{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T20:16:45Z","timestamp":1777580205978,"version":"3.51.4"},"reference-count":24,"publisher":"SAGE Publications","issue":"1","license":[{"start":{"date-parts":[[2016,6,27]],"date-time":"2016-06-27T00:00:00Z","timestamp":1466985600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["European Journal of Ophthalmology"],"published-print":{"date-parts":[[2017,1]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To evaluate morphologic changes in the anterior segment using ultrasound biomicroscopic imaging (UBM) after phacoemulsification and foldable intraocular lens implantation (IOL).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Thirty-six patients with a mean age of 68.68 \u00b1 8.44 years (range 51-89) who had phacoemulsification and foldable IOL implantation were included in this prospective study. Several anterior segment parameters including aqueous depth (AQD), trabecular meshwork-iris angle (TIA), ciliary body thickness (CBT), sclera thickness (ST), trabecular meshwork-ciliary process distance (T-CPD), iris-ciliary processes distance (I-CPD), and iris thickness (IT) were measured using UBM preoperatively and at postoperative month 2.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>There was a significant increase in AQD (p&lt;0.001) and TIA (p&lt;0.001) at postoperative month 2. However, CBT, ST, T-CPD, I-CPD, and IT did not significantly change (p&gt;0.05) during the study period.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Removal of the crystalline lens results in change in the anterior segment parameters. Our results confirmed that UBM is a helpful option for the analysis of anterior segment structures both qualitatively and quantitatively.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.5301\/ejo.5000812","type":"journal-article","created":{"date-parts":[[2016,7,5]],"date-time":"2016-07-05T04:14:00Z","timestamp":1467692040000},"page":"31-38","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":12,"title":["Morphologic Changes in the Anterior Segment using Ultrasound Biomicroscopy after Cataract Surgery and Intraocular Lens Implantation"],"prefix":"10.1177","volume":"27","author":[{"given":"Erkan","family":"\u00dcnsal","sequence":"first","affiliation":[{"name":"Istanbul Research and Training Hospital, Department of Ophthalmology, Kasap Ilyas Mah Org Abdurrahman Nafiz, Fatih, Istanbul - Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kadir","family":"Eltutar","sequence":"additional","affiliation":[{"name":"Istanbul Research and Training Hospital, Department of Ophthalmology, Kasap Ilyas Mah Org Abdurrahman Nafiz, Fatih, Istanbul - Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"\u0130lkay K.","family":"Muftuoglu","sequence":"additional","affiliation":[{"name":"Istanbul Research and Training Hospital, Department of Ophthalmology, Kasap Ilyas Mah Org Abdurrahman Nafiz, Fatih, Istanbul - Turkey"},{"name":"Jacobs Retina Center at the Shiley Eye Institute, University of California, San Diego, CA - USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2016,6,27]]},"reference":[{"key":"bibr1-ejo.5000812","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2005.06.024"},{"issue":"9","key":"bibr2-ejo.5000812","first-page":"3549","volume":"35","author":"Tello C","year":"1994","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"3","key":"bibr3-ejo.5000812","first-page":"293","volume":"77","author":"Urbak SF","year":"1999","journal-title":"III. Accuracy and agreement of measurements. Acta Ophthalmol Scand"},{"key":"bibr4-ejo.5000812","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(98)91132-0"},{"key":"bibr5-ejo.5000812","doi-asserted-by":"publisher","DOI":"10.1097\/00061198-199702000-00004"},{"issue":"2","key":"bibr6-ejo.5000812","first-page":"150","volume":"6","author":"Wang JK","year":"2013","journal-title":"Int J Ophthalmol"},{"key":"bibr7-ejo.5000812","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2011.02.033"},{"issue":"4","key":"bibr8-ejo.5000812","first-page":"632","volume":"153","author":"Kojima T","year":"2012","journal-title":"Optimization of an implantable collamer lens sizing method using high-frequency ultrasound biomicroscopy. Am J Ophthalmol"},{"issue":"3","key":"bibr9-ejo.5000812","first-page":"232","volume":"101","author":"Dick HB","year":"2004","journal-title":"Current status and limitations]. Ophthalmologe"},{"key":"bibr10-ejo.5000812","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(02)01893-X"},{"key":"bibr11-ejo.5000812","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(03)00413-9"},{"key":"bibr12-ejo.5000812","doi-asserted-by":"publisher","DOI":"10.1016\/j.exer.2004.12.004"},{"key":"bibr13-ejo.5000812","doi-asserted-by":"publisher","DOI":"10.1097\/00055735-200004000-00012"},{"key":"bibr14-ejo.5000812","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(91)32298-X"},{"key":"bibr15-ejo.5000812","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(14)76159-8"},{"key":"bibr16-ejo.5000812","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(14)71694-0"},{"key":"bibr17-ejo.5000812","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(03)00623-7"},{"key":"bibr18-ejo.5000812","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20150319-06"},{"key":"bibr19-ejo.5000812","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2014.08.033"},{"key":"bibr20-ejo.5000812","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(00)00524-9"},{"issue":"3","key":"bibr21-ejo.5000812","doi-asserted-by":"crossref","first-page":"e0120843","DOI":"10.1371\/journal.pone.0120843","volume":"10","author":"Wang Z","year":"2015","journal-title":"PLoS One"},{"key":"bibr22-ejo.5000812","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-015-3135-7"},{"key":"bibr23-ejo.5000812","doi-asserted-by":"publisher","DOI":"10.1038\/eye.2009.339"},{"key":"bibr24-ejo.5000812","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2004.047662"}],"container-title":["European Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.5301\/ejo.5000812","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.5301\/ejo.5000812","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.5301\/ejo.5000812","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T19:40:28Z","timestamp":1777405228000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.5301\/ejo.5000812"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,6,27]]},"references-count":24,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2017,1]]}},"alternative-id":["10.5301\/ejo.5000812"],"URL":"https:\/\/doi.org\/10.5301\/ejo.5000812","relation":{},"ISSN":["1120-6721","1724-6016"],"issn-type":[{"value":"1120-6721","type":"print"},{"value":"1724-6016","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,6,27]]}}}