{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T05:44:02Z","timestamp":1787031842821,"version":"build-2736575974"},"reference-count":11,"publisher":"SAGE Publications","issue":"1","license":[{"start":{"date-parts":[[2017,5,27]],"date-time":"2017-05-27T00:00:00Z","timestamp":1495843200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["European Journal of Ophthalmology"],"published-print":{"date-parts":[[2018,1]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To discuss the limitations and benefits of the BrightOcular prosthetic artificial iris device in management of aniridia associated with aphakia or cataract.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>This is a retrospective study including 5 eyes of 4 patients who underwent implantation of the BrightOcular iris prosthesis (Stellar Devices) for total or partial aniridia. The cases included 2 eyes of 1 patient with congenital aniridia associated with congenital cataract and 3 eyes with traumatic aniridia: 1 with subluxated cataractous lens and 2 with aphakia. In all cases, the iris prosthesis was implanted after a 3-piece acrylic intraocular lens was implanted. We evaluated the clinical course with a minimum follow-up period of 6 months, the intraoperative and postoperative complications, and the cosmetic satisfaction of patients.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>All patients had improved uncorrected distance visual acuity and best-corrected distance visual acuity. All patients had a transient corneal edema that resolved within the first postoperative week. Only the patient with congenital aniridia had a permanent increase in intraocular pressure and developed a band keratopathy throughout a 2-year follow-up period. The prosthesis was well-centered in all eyes except for one case that required scleral suture fixation after 3 months. All patients had a satisfactory cosmetic appearance.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>BrightOcular iris prosthesis is a safe and useful tool to correct aniridia associated with pseudophakia or aphakia. Being foldable, it is easy to be implanted through a small incision and placed in the ciliary sulcus without sutures when properly sized. Cosmetic results are satisfactory. Sizing methods should be improved.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.5301\/ejo.5000991","type":"journal-article","created":{"date-parts":[[2017,6,2]],"date-time":"2017-06-02T05:56:11Z","timestamp":1496382971000},"page":"103-107","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":16,"title":["Iris reconstruction using artificial iris prosthesis for management of aniridia"],"prefix":"10.1177","volume":"28","author":[{"given":"Yehia S.","family":"Mostafa","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Cairo University, Cairo - Egypt"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amr A.","family":"Osman","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Cairo University, Cairo - Egypt"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dina H.","family":"Hassanein","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Cairo University, Cairo - Egypt"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ashraf M.","family":"Zeid","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Ain Shams University, Cairo - Egypt"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmed M.","family":"Sherif","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Cairo University, Cairo - Egypt"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2017,5,27]]},"reference":[{"key":"bibr1-ejo.5000991","doi-asserted-by":"publisher","DOI":"10.1177\/112067210901900633"},{"key":"bibr2-ejo.5000991","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcjo.2013.10.001"},{"key":"bibr3-ejo.5000991","doi-asserted-by":"publisher","DOI":"10.1001\/archophthalmol.2011.1778"},{"key":"bibr4-ejo.5000991","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2013.08.051"},{"key":"bibr5-ejo.5000991","doi-asserted-by":"publisher","DOI":"10.1111\/j.1755-3768.2008.01499.x"},{"key":"bibr6-ejo.5000991","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.02.035"},{"key":"bibr7-ejo.5000991","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2009.06.008"},{"key":"bibr8-ejo.5000991","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2010.11.010"},{"key":"bibr9-ejo.5000991","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2012.03.021"},{"key":"bibr10-ejo.5000991","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2014.09.015"},{"key":"bibr11-ejo.5000991","doi-asserted-by":"publisher","DOI":"10.1097\/ICU.0000000000000253"}],"container-title":["European Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.5301\/ejo.5000991","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.5301\/ejo.5000991","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.5301\/ejo.5000991","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T19:41:04Z","timestamp":1777405264000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.5301\/ejo.5000991"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,5,27]]},"references-count":11,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2018,1]]}},"alternative-id":["10.5301\/ejo.5000991"],"URL":"https:\/\/doi.org\/10.5301\/ejo.5000991","relation":{},"ISSN":["1120-6721","1724-6016"],"issn-type":[{"value":"1120-6721","type":"print"},{"value":"1724-6016","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,5,27]]}}}