{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T22:53:41Z","timestamp":1777676021596,"version":"3.51.4"},"reference-count":44,"publisher":"SAGE Publications","issue":"5","license":[{"start":{"date-parts":[[2013,9,1]],"date-time":"2013-09-01T00:00:00Z","timestamp":1377993600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["HIP International"],"published-print":{"date-parts":[[2013,9]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>To investigate the behavior of Arc2f polyethylene (PE) component after a minimum of 15 years post implantation and its possible reasons for failure.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"methods\">\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Between January 1988 and March 1995, 557 cementless total hip arthroplasties were performed in 578 patients. A total of 435 patients (450 hips) were followed up for 18.6 years (range 15-22).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"results\">\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>At 10 years follow-up no cup needed revision surgery. After 15 years of implantation, we observed massive PE wear in 140 cups (31%) with large osteolytic lesions. A revision procedure was performed in all cases. Exchange only of the PE liner was sufficient in 78 cases, whilst in 59 the cup was also revised. PE insert thickness and the type of prosthetic head were found to be related to PE wear.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"conclusions\">\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>We postulate that the massive failure seen is attributed to the manufacturing of the PE insert. We advocate following all patients that have an implant lasting a decade after implantation for routine monitoring to identify those at risk for accelerated PE wear.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.5301\/hipint.5000043","type":"journal-article","created":{"date-parts":[[2013,10,28]],"date-time":"2013-10-28T09:43:33Z","timestamp":1382953413000},"page":"478-483","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["Surveillance of Arc2f Polyethylene after 15 Years of Implantation"],"prefix":"10.1177","volume":"23","author":[{"given":"George A.","family":"Macheras","sequence":"first","affiliation":[{"name":"KAT Hospital, Athens, Attica - Greece"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stefanos D.","family":"Koutsostathis","sequence":"additional","affiliation":[{"name":"Mitera Hospital, Maroussi, Attica - Greece"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Spyridon","family":"Galanakos","sequence":"additional","affiliation":[{"name":"D Department of Orthopaedics, KAT Hospital, Athens - Greece"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Konstantinos","family":"Kateros","sequence":"additional","affiliation":[{"name":"2nd Orthopaedic Department, Gennimatas General Hospital, Athens - Greece"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stamatios A.","family":"Papadakis","sequence":"additional","affiliation":[{"name":"D Department of Orthopaedics, KAT Hospital, Athens - Greece"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2013,9,8]]},"reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.76B4.8027143"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200102000-00019"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(05)80199-8"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2004.11.006"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(99)90090-6"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.81B4.8715"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2007.04.026"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1177\/112070000801800201"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1054\/arth.2003.50039"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1080\/00016470052943856"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1080\/00016470410001213"},{"key":"e_1_3_2_13_2","first-page":"257","article-title":"Complications in primary total hip arthroplasty: avoidance and management: wear","volume":"52","author":"Ries MD","year":"2003","unstructured":"RiesMD Complications in primary total hip arthroplasty: avoidance and management: wear. Instr Course Lect 200352257\u201365","journal-title":"Instr Course Lect"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(98)90085-7"},{"key":"e_1_3_2_15_2","unstructured":"DuthoitE EpinetteJ-A CarlierY The Arc2f cup: biomechanics and interface. Systemic study of HA-coated vs. porous textured components. In: EpinetteJ-A GeesinkRGTeds Cahiers d'enseignement de la SOFCOT Paris Expansion Scientifique Francaise Paris France. 1995176"},{"issue":"121","key":"e_1_3_2_16_2","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1097\/00003086-197611000-00003","article-title":"Radiological demarcation of cemented sockets in total hip replacement","author":"DeLee JG","year":"1976","unstructured":"DeLeeJG CharnleyJ Radiological demarcation of cemented sockets in total hip replacement. Clin. Orthop Relat Res 197612120\u201332","journal-title":"Clin. Orthop Relat Res"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(07)80027-1"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(05)80208-6"},{"key":"e_1_3_2_19_2","unstructured":"We ScheierH SandelJ Wear affecting the plastic cup in metal-plastic endoprostheses. In: GschwendN DebrunnerHUeds Total hip prostheses. Huber Bern 1976186"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1243\/0954411971534683"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.85B4.13397"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1115\/1.3138543"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-200300004-00007"},{"key":"e_1_3_2_24_2","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1097\/00003086-199110000-00027","article-title":"Comparison of porous threaded and smooth-threaded acetabular components of identical design","volume":"271","author":"Pupparo F","year":"1991","unstructured":"PupparoF EnghCA Comparison of porous threaded and smooth-threaded acetabular components of identical design. Clin Orthop Relat Res 1991271201\u20136","journal-title":"Clin Orthop Relat Res"},{"key":"e_1_3_2_25_2","unstructured":"CartillierJC The contribution of hydroxyapatite: study of implants of identical geometry with and without hydroxyapatite coating p. In: EpinetteJ-A GeesinkRGT(eds) Cashiers d'enseignement de la SOFCOT. Paris Expansion Scientifique Francaise Paris France. 1995165"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199707000-00017"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1007\/s002640050198"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.3109\/17453679808999050"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.77B4.7615595"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(96)80001-5"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-200411000-00029"},{"key":"e_1_3_2_32_2","unstructured":"SiverhusS BryantDR Early clinical results of an arc-deposited hydroxyapatite coated acetabular component in total hip arthroplasty. In: EpinetteJA ManleyMTeds Fifteen years of clinical experience with hydroxyapatite coatings in joint arthroplasty. New York Springer 2004171\u20136"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-199072040-00008"},{"key":"e_1_3_2_34_2","doi-asserted-by":"publisher","DOI":"10.5435\/00124635-199407000-00004"},{"issue":"308","key":"e_1_3_2_35_2","first-page":"111","article-title":"Etiology of osteolysis around porous-coated cementless total hip arthroplasties","author":"Jasty M","year":"1994","unstructured":"JastyM BragdonC JiranekW ChandlerH MaloneyW HarrisWH Etiology of osteolysis around porous-coated cementless total hip arthroplasties. Clin Orthop Relat Res 1994308111\u201326","journal-title":"Clin Orthop Relat Res"},{"key":"e_1_3_2_36_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.79B3.6630"},{"key":"e_1_3_2_37_2","doi-asserted-by":"publisher","DOI":"10.1054\/arth.2002.33664"},{"key":"e_1_3_2_38_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2007.11.010"},{"key":"e_1_3_2_39_2","doi-asserted-by":"publisher","DOI":"10.3233\/BME-1997-7105"},{"key":"e_1_3_2_40_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2004.09.023"},{"issue":"3","key":"e_1_3_2_41_2","first-page":"294","article-title":"Unsatisfactory results with the cementless Omnifit acetabular component due to polyethylene and severe osteolysis","volume":"71","author":"Nieuwenhuis JJ","year":"2005","unstructured":"NieuwenhuisJJ MalefijtJdeW HendriksJC GosensT BonnetM Unsatisfactory results with the cementless Omnifit acetabular component due to polyethylene and severe osteolysis. Acta Orthop Belg 2005713294\u2013302","journal-title":"Acta Orthop Belg"},{"key":"e_1_3_2_42_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2010.09.009"},{"issue":"319","key":"e_1_3_2_43_2","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1097\/00003086-199510000-00004","article-title":"The Otto Aufranc Award. Impact of gamma sterilization on clinical performance of polyethylene in the hip","author":"Sutula LC","year":"1995","unstructured":"SutulaLC CollierJP SaumKA The Otto Aufranc Award. Impact of gamma sterilization on clinical performance of polyethylene in the hip. Clin Orthop Relat Res 199531928\u201340","journal-title":"Clin Orthop Relat Res"},{"key":"e_1_3_2_44_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.H.00538"},{"key":"e_1_3_2_45_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2010.04.018"}],"container-title":["HIP International"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.5301\/hipint.5000043","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.5301\/hipint.5000043","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.5301\/hipint.5000043","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T08:17:25Z","timestamp":1777450645000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.5301\/hipint.5000043"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,9]]},"references-count":44,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2013,9]]}},"alternative-id":["10.5301\/hipint.5000043"],"URL":"https:\/\/doi.org\/10.5301\/hipint.5000043","relation":{},"ISSN":["1120-7000","1724-6067"],"issn-type":[{"value":"1120-7000","type":"print"},{"value":"1724-6067","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,9]]}}}