{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,8]],"date-time":"2026-07-08T03:31:35Z","timestamp":1783481495616,"version":"3.55.0"},"reference-count":27,"publisher":"SAGE Publications","issue":"3","license":[{"start":{"date-parts":[[2015,4,29]],"date-time":"2015-04-29T00:00:00Z","timestamp":1430265600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["HIP International"],"published-print":{"date-parts":[[2015,5]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>Cross-linking has proven effective in reducing polyethylene wear in total hip replacements. However, increasing the amount of cross-links will impair other mechanical properties of the polyethylene. The optimal threshold of crosslinking has still not been established. This led to the development of a moderately cross-linked (5 Mrad) cemented cup in which wear and stability is yet to be determined.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A total of, 70 hips were included in this case series on the cemented Marathon\u00ae cup. Mean age of the patients was 78 years (SD 15). We measured wear and migration by radiostereometry at 3, 12 and 24 months.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The proximal wear rate estimate between 3 to 24 months was 0.036 mm\/year, and a total proximal wear estimate at 2 years of 0.11 mm (95% CI 0.09-0.14). Translations and rotations along the 3 cardinal axes were all at or below the precision limit, and less than what is believed to be predictive of later loosening, namely 0.2-1 mm for proximal migration. The cups remained stable after the initial \u201cbedding in\u201d that occurred during the first 3 months.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Our results indicate that moderate cross-linking (5Mrad) yields low wear and high stability in this specific acetabular cup, comparable to other cups with higher cross-linking.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.5301\/hipint.5000230","type":"journal-article","created":{"date-parts":[[2015,5,18]],"date-time":"2015-05-18T06:24:58Z","timestamp":1431930298000},"page":"199-203","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":6,"title":["Low Wear, High Stability - Promises of Success in a Moderately Cross-Linked Cup?"],"prefix":"10.1177","volume":"25","author":[{"given":"Bernhard","family":"Flat\u00f8y","sequence":"first","affiliation":[{"name":"Orthopaedic Department, Oslo University Hospital, Ullev\u00e5l, Oslo - Norway"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonas","family":"Rydinge","sequence":"additional","affiliation":[{"name":"Orthopaedic Department, Oslo University Hospital, Ullev\u00e5l, Oslo - Norway"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jon","family":"Dahl","sequence":"additional","affiliation":[{"name":"Orthopaedic Department, Oslo University Hospital, Rikshospitalet, Oslo - Norway"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephan M.","family":"R\u00f6hrl","sequence":"additional","affiliation":[{"name":"Orthopaedic Department, Oslo University Hospital, Ullev\u00e5l, Oslo - Norway"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lars","family":"Nordsletten","sequence":"additional","affiliation":[{"name":"Orthopaedic Department, Oslo University Hospital, Ullev\u00e5l, Oslo - Norway"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2015,4,29]]},"reference":[{"key":"bibr1-hipint.5000230","doi-asserted-by":"publisher","DOI":"10.3109\/17453670903161124"},{"issue":"10","key":"bibr2-hipint.5000230","first-page":"93","volume":"2","author":"Atkins H","year":"2011","journal-title":"Role of polyethylene particles in peri-prosthetic osteolysis: A review. World J Orthod"},{"key":"bibr3-hipint.5000230","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2008.12.006"},{"key":"bibr4-hipint.5000230","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.a.10090"},{"key":"bibr5-hipint.5000230","doi-asserted-by":"publisher","DOI":"10.1016\/j.nimb.2007.08.022"},{"key":"bibr6-hipint.5000230","doi-asserted-by":"publisher","DOI":"10.1016\/S0142-9612(97)00160-9"},{"issue":"18","key":"bibr7-hipint.5000230","first-page":"1741","volume":"17","author":"Premnath V","year":"1996","journal-title":"Ultra High Molecular Weight Poly Ethylene. Biomaterials"},{"key":"bibr8-hipint.5000230","doi-asserted-by":"publisher","DOI":"10.1097\/01.blo.0000152603.58384.e9"},{"key":"bibr9-hipint.5000230","doi-asserted-by":"publisher","DOI":"10.1097\/01.blo.0000073343.50837.03"},{"issue":"7","key":"bibr10-hipint.5000230","first-page":"1487","volume":"90","author":"Bitsch RG","year":"2008","journal-title":"A concise follow-up, at a minimum of five years, of a previous report. J Bone Joint Surg Am"},{"key":"bibr11-hipint.5000230","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-013-2789-x"},{"key":"bibr12-hipint.5000230","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2012.03.048"},{"key":"bibr13-hipint.5000230","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2008.05.009"},{"key":"bibr14-hipint.5000230","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-010-1379-4"},{"key":"bibr15-hipint.5000230","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-012-1738-8"},{"issue":"4","key":"bibr16-hipint.5000230","first-page":"235","volume":"1","author":"Molenberghs G","year":"2001","journal-title":"A review on linear mixed models for longitudinal data, possibly subject to dropout. Stat Model"},{"key":"bibr17-hipint.5000230","first-page":"40","author":"Machin D","year":"2005","journal-title":"2nd ed. Chichester, West Sussex: John Wiley & Sons Ltd"},{"key":"bibr18-hipint.5000230","doi-asserted-by":"publisher","DOI":"10.3109\/17453674.2012.742393"},{"key":"bibr19-hipint.5000230","doi-asserted-by":"publisher","DOI":"10.1054\/arth.2002.33664"},{"key":"bibr20-hipint.5000230","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2005.09.033"},{"key":"bibr21-hipint.5000230","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.K.00305"},{"key":"bibr22-hipint.5000230","doi-asserted-by":"publisher","DOI":"10.3109\/17453674.2012.745353"},{"issue":"228","key":"bibr23-hipint.5000230","first-page":"105","author":"Hodgkinson JP","year":"1988","journal-title":"Clin Orthop Relat Res"},{"key":"bibr24-hipint.5000230","doi-asserted-by":"publisher","DOI":"10.1002\/jor.21389"},{"key":"bibr25-hipint.5000230","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-012-2400-x"},{"key":"bibr26-hipint.5000230","doi-asserted-by":"publisher","DOI":"10.1097\/01.blo.0000150314.70919.e3"},{"key":"bibr27-hipint.5000230","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2004.09.040"}],"container-title":["HIP International"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.5301\/hipint.5000230","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.5301\/hipint.5000230","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.5301\/hipint.5000230","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T08:18:18Z","timestamp":1777450698000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.5301\/hipint.5000230"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,4,29]]},"references-count":27,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2015,5]]}},"alternative-id":["10.5301\/hipint.5000230"],"URL":"https:\/\/doi.org\/10.5301\/hipint.5000230","relation":{},"ISSN":["1120-7000","1724-6067"],"issn-type":[{"value":"1120-7000","type":"print"},{"value":"1724-6067","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,4,29]]}}}