{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,13]],"date-time":"2026-05-13T02:20:09Z","timestamp":1778638809988,"version":"3.51.4"},"reference-count":29,"publisher":"Ubiquity Press, Ltd.","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,8,21]]},"DOI":"10.5334\/gh.1344","type":"journal-article","created":{"date-parts":[[2024,8,22]],"date-time":"2024-08-22T00:57:38Z","timestamp":1724288258000},"source":"Crossref","is-referenced-by-count":1,"title":["Pilot Study of Intelligent Office Blood Pressure Measurement Model in Shanghai, China, 2022"],"prefix":"10.5334","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0009-0004-5139-1563","authenticated-orcid":false,"given":"Guoli","family":"Wu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0003-5401-1266","authenticated-orcid":false,"given":"Qinghua","family":"Yan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8562-4477","authenticated-orcid":false,"given":"Fernando","family":"Mart\u00ednez-Garc\u00eda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1501-2990","authenticated-orcid":false,"given":"Dinesh","family":"Neupane","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuheng","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fei","family":"Wu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cui","family":"Wu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Barbara Lee","family":"Smith","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2952-8565","authenticated-orcid":false,"given":"Yan","family":"Shi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1270-6153","authenticated-orcid":false,"given":"Minna","family":"Cheng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"3285","reference":[{"key":"key20240822005732_B1","unstructured":"National Bureau of Statistics of China. Communiqu\u00e9 of the Seventh National Population Census (No. 5). China: NBS of China; 2021. Available from: http:\/\/www.stats.gov.cn\/english\/PressRelease\/202105\/t20210510_1817190.html"},{"issue":"4","key":"key20240822005732_B2","doi-asserted-by":"crossref","first-page":"576","DOI":"10.1038\/s41440-022-00875-7","article-title":"STEP to blood pressure management of elderly hypertension: evidence from Asia","volume":"45","year":"2022","journal-title":"Hypertension Research"},{"issue":"22","key":"key20240822005732_B3","doi-asserted-by":"crossref","first-page":"2344","DOI":"10.1161\/CIRCULATIONAHA.117.032380","article-title":"Status of hypertension in China: Results from the China Hypertension Survey, 2012\u20132015","volume":"137","year":"2018","journal-title":"Circulation"},{"issue":"4","key":"key20240822005732_B4","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1097\/MBP.0000000000000121","article-title":"Reliability of home blood pressure monitoring: in the context of validation and accuracy","volume":"20","year":"2015","journal-title":"Blood Press Monit"},{"issue":"9","key":"key20240822005732_B5","doi-asserted-by":"crossref","first-page":"1737","DOI":"10.1097\/HJH.0000000000002112","article-title":"Optimizing observer performance of clinic blood pressure measurement: a position statement from the Lancet Commission on Hypertension Group","volume":"37","year":"2019","journal-title":"J Hypertens"},{"issue":"6","key":"key20240822005732_B6","doi-asserted-by":"crossref","first-page":"1072","DOI":"10.1097\/HJH.0000000000002384","article-title":"Associations between various attended automated office blood pressure estimations and all-cause and cardiovascular mortality: Minhang study","volume":"38","year":"2020","journal-title":"J Hypertens"},{"key":"key20240822005732_B7","volume-title":"Technical Management Specification of the Auto-Measuring Device for Office Blood Pressure Monitoring in Community-based Health Management for Non-communicable Diseases","author":"Shanghai Municipal Center for Disease Control and Prevention","year":"2020"},{"issue":"3","key":"key20240822005732_B8","first-page":"182","article-title":"2018 Chinese Guidelines for Prevention and Treatment of Hypertension-A report of the Revision Committee of Chinese Guidelines for Prevention and Treatment of Hypertension","volume":"16","author":"Joint Committee for Guideline Revision","year":"2019","journal-title":"J Geriatr Cardiol"},{"key":"key20240822005732_B9","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1186\/s12872-015-0177-z","article-title":"Validation of Omron HBP-1300 professional blood pressure monitor based on auscultation in children and adults","volume":"16","year":"2016","journal-title":"BMC Cardiovasc Disord"},{"key":"key20240822005732_B10","unstructured":"Cheng MN, Wang YH, Yan QH, Yao HH, Shi Y. Epidemic status of hypertension among residents aged 18 years and older of Shanghai in 2013. China J Hypertens. 2017; 25(5): 451\u2013455. http:\/\/dx.chinadoi.cn\/10.16439\/j.cnki.1673-7245.2017.05.013"},{"issue":"8","key":"key20240822005732_B11","article-title":"Association of an automated blood pressure measurement quality improvement program with terminal digit preference and recorded mean blood pressure in 11 Clinics","volume":"5","year":"2022","journal-title":"JAMA Netw Open"},{"issue":"1","key":"key20240822005732_B12","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1038\/s41371-021-00650-0","article-title":"Protocol to improve hypertension management in a VA outpatient clinic","volume":"37","year":"2023","journal-title":"J Hum Hypertens"},{"issue":"12","key":"key20240822005732_B13","doi-asserted-by":"crossref","first-page":"1655","DOI":"10.1001\/jamainternmed.2020.5028","article-title":"Concordance between blood pressure in the systolic blood pressure intervention trial and in routine clinical practice","volume":"180","year":"2020","journal-title":"JAMA Intern Med"},{"issue":"4","key":"key20240822005732_B14","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1097\/MBP.0000000000000392","article-title":"Comparison of routine and automated office blood pressure measurement","volume":"24","year":"2019","journal-title":"Blood Press Monit"},{"issue":"1","key":"key20240822005732_B15","article-title":"Are self-reported telemonitored blood pressure readings affected by end-digit preference: a prospective cohort study in Scotland","volume":"8","year":"2018","journal-title":"BMJ Open"},{"issue":"3","key":"key20240822005732_B16","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1097\/MBP.0000000000000035","article-title":"Use of home blood pressure monitoring among hypertensive adults in primary care: Minhang community survey","volume":"19","year":"2014","journal-title":"Blood Press Monit"},{"issue":"5","key":"key20240822005732_B17","doi-asserted-by":"crossref","first-page":"521","DOI":"10.1093\/ajh\/hpaa196","article-title":"Digit preference in office blood pressure measurements, United States 2015\u20132019","volume":"34","year":"2021","journal-title":"Am J Hypertens"},{"issue":"2","key":"key20240822005732_B18","doi-asserted-by":"crossref","first-page":"85","DOI":"10.5830\/CVJA-2011-045","article-title":"End digit preference in blood pressure measurement in a hypertension specialty clinic in southwest Nigeria","volume":"23","year":"2012","journal-title":"Cardiovasc J Afr"},{"issue":"6","key":"key20240822005732_B19","doi-asserted-by":"crossref","first-page":"567","DOI":"10.1016\/j.amjhyper.2005.04.004","article-title":"The impact of observer and patient factors on the occurrence of digit preference for zero in blood pressure measurement in a hypertension specialty clinic: Evidence for the need of continued observation","volume":"19","year":"2006","journal-title":"Am J Hypertens"},{"issue":"1","key":"key20240822005732_B20","article-title":"Trends in end digit preference for blood pressure and associations with cardiovascular outcomes in Canadian and UK primary care: A retrospective observational study","volume":"9","year":"2019","journal-title":"BMJ Open"},{"issue":"2","key":"key20240822005732_B21","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1097\/MBP.0000000000000092","article-title":"Longitudinal change in end-digit preference in blood pressure recordings of patients with hypertension in primary care clinics: Minhang study","volume":"20","year":"2015","journal-title":"Blood Press Monit"},{"issue":"1","key":"key20240822005732_B22","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1111\/j.1742-1241.2011.02781.x","article-title":"Trends and transient change in end-digit preference in blood pressure recording: Studies of sequential and longitudinal collected primary care data","volume":"66","year":"2012","journal-title":"Int J Clin Pract"},{"issue":"10304","key":"key20240822005732_B23","doi-asserted-by":"crossref","first-page":"957","DOI":"10.1016\/S0140-6736(21)01330-1","article-title":"Worldwide trends in hypertension prevalence and progress in treatment and control from 1990 to 2019: a pooled analysis of 1201 population-representative studies with 104 million participants","volume":"398","author":"NCD Risk Factor Collaboration (NCD-RisC)","year":"2021","journal-title":"Lancet"},{"key":"key20240822005732_B24","article-title":"Intelligent Assist Office Blood Pressures (IOBP) versus awake ambulatory monitoring and conventional auscultatory office readings in Chinese primary medical institutions","year":"2024","journal-title":"Hypertens Res"},{"issue":"1","key":"key20240822005732_B25","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1007\/s11906-017-0700-y","article-title":"The un-observed automated office blood pressure measurement technique used in the SPRINT Study Points to a standard target office systolic blood pressure <140 mmHg","volume":"19","year":"2017","journal-title":"Curr Hypertens Rep"},{"issue":"7","key":"key20240822005732_B26","doi-asserted-by":"crossref","first-page":"1104","DOI":"10.1111\/jch.13276","article-title":"Office blood pressure measurement in the 21st century","volume":"20","year":"2018","journal-title":"J Clin Hypertens"},{"issue":"8","key":"key20240822005732_B27","doi-asserted-by":"crossref","first-page":"721","DOI":"10.1111\/jch.12820","article-title":"A short history of automated office blood pressure \u2013 15 years to SPRINT","volume":"18","year":"2016","journal-title":"J Clin Hypertens"},{"issue":"7","key":"key20240822005732_B28","doi-asserted-by":"crossref","first-page":"1084","DOI":"10.1111\/jch.13323","article-title":"Achieving reliable blood pressure measurements in clinical practice: It\u2019s time to meet the challenge","volume":"20","year":"2018","journal-title":"J Clin Hypertens"},{"issue":"12","key":"key20240822005732_B29","doi-asserted-by":"crossref","first-page":"1874","DOI":"10.1097\/HJH.0000000000003480","article-title":"2023 ESH Guidelines for the management of arterial hypertension The Task Force for the management of arterial hypertension of the European Society of Hypertension: Endorsed by the International Society of Hypertension (ISH) and the European Renal Association (ERA)","volume":"41","year":"2023","journal-title":"J Hypertens"}],"container-title":["Global Heart"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/storage.googleapis.com\/jnl-up-j-gh-files\/journals\/1\/articles\/1344\/66c5d2d707c87.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,27]],"date-time":"2025-10-27T08:02:02Z","timestamp":1761552122000},"score":1,"resource":{"primary":{"URL":"https:\/\/globalheartjournal.com\/articles\/10.5334\/gh.1344\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024]]},"references-count":29,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2024,8,21]]}},"alternative-id":["10.5334\/gh.1344"],"URL":"https:\/\/doi.org\/10.5334\/gh.1344","relation":{},"ISSN":["2211-8179"],"issn-type":[{"value":"2211-8179","type":"print"}],"subject":[],"published":{"date-parts":[[2024]]},"article-number":"67"}}