{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,22]],"date-time":"2025-02-22T00:00:36Z","timestamp":1740182436504,"version":"3.37.3"},"reference-count":36,"publisher":"Korean Shoulder and Elbow Society","issue":"4","license":[{"start":{"date-parts":[[2024,11,8]],"date-time":"2024-11-08T00:00:00Z","timestamp":1731024000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["cisejournal.org"],"crossmark-restriction":true},"short-container-title":["Clin Shoulder Elb"],"published-print":{"date-parts":[[2024,12,1]]},"abstract":"<jats:p>Background: Adult humeral shaft fractures have traditionally been managed conservatively, but surgical intervention is considered for displaced fractures or when conservative treatment is unlikely to be successful. The optimal surgical approach remains controversial, with open reduction and internal fixation (ORIF) using plates and screws considered the gold standard. However, concerns about soft tissue damage have led to the development of less invasive techniques, such as anterior bridge plating using minimally invasive plate osteosynthesis (MIPO). This study aimed to evaluate the outcomes of MIPO for humeral shaft fractures.Methods: A prospective cohort study included 43 patients who underwent anterior bridge plating with MIPO for closed, displaced humeral shaft fractures. Forty patients had full follow-up (functional and radiological) and three patients were lost to follow-up. Fractures were classified using the AO classification system. Surgical technique involved incision, reduction, and fixation with locking compression plates. Follow-up assessments were conducted at various intervals, and functional outcomes were evaluated.Results: Fracture union was achieved in 38 of 40 patients (95%). Two patients required secondary bone grafts for non-union. The mean time to union was between 12 and 16 weeks. Excellent shoulder function was observed in 82.5% of patients, and excellent elbow function in 77.5%. The range of motion on the operated side differed statistically significantly from the nonoperated side but was not clinically significant.Conclusions: MIPO with anterior bridge plating is a viable option for the surgical management of humeral shaft fractures. It offers good fracture healing rates and satisfactory functional outcomes and avoids extensive soft tissue dissection associated with ORIF.Level of evidence: II.<\/jats:p>","DOI":"10.5397\/cise.2024.00423","type":"journal-article","created":{"date-parts":[[2024,11,11]],"date-time":"2024-11-11T07:51:48Z","timestamp":1731311508000},"page":"479-486","update-policy":"https:\/\/doi.org\/10.5397\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["A prospective cohort study: promising results with minimally invasive plate osteosynthesis of anterior bridge plating in adult humeral shaft fractures"],"prefix":"10.5397","volume":"27","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4655-7563","authenticated-orcid":true,"given":"Gur-Aziz Singh","family":"Sidhu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-3298-3679","authenticated-orcid":true,"given":"Deepak","family":"Jain","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0006-8592-5011","authenticated-orcid":true,"given":"Harpal Singh","family":"Selhi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8431-102X","authenticated-orcid":true,"given":"Harjot","family":"Kaur","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5222-0548","authenticated-orcid":true,"given":"Sergio","family":"Rowinski","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2285-2741","authenticated-orcid":true,"given":"Saphalya","family":"Pattnaik","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2238-5082","authenticated-orcid":true,"given":"Neil","family":"Ashwood","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"3351","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1016\/s0020-1383(05)80008-7"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-198204000-00033"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-197759050-00004"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2010.11.030"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1080\/17453670610046037"},{"key":"ref6","first-page":"336","volume-title":"Fixation of fractures of the shaft of the humerus by dynamic compression plate or intramedullary nail: a prospective, randomised trial","author":"McCormack","year":"2000"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1097\/00005131-200003000-00002"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-009-0753-x"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-007-0313-z"},{"key":"ref10","first-page":"239","volume-title":"Minimally invasive surgery in diaphyseal humeral fractures with helicoidal plate: one year result in seven patients","author":"Numbela","year":"2007"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1159\/000095487"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-008-0537-8"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.5435\/00124635-200600001-00028"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-004-0620-8"},{"key":"ref15","first-page":"391","volume-title":"Comparison of the use of the humerus intramedullary nail and dynamic compression plate for the management of diaphyseal fractures of the humerus: a randomized controlled study","author":"Changulani","year":"2007"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.4103\/0019-5413.33685"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-198668070-00002"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1097\/00005131-199506000-00003"},{"key":"ref19","first-page":"346","volume-title":"Fractures of the shaft of the humerus: systematic plate fixation: anatomic and functional results in 156 cases and a review of the literature","author":"Paris","year":"2000"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-009-0813-2"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2003.10.021"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620x.48b1.105"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.1016\/s0020-1383(03)00220-1"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200301000-00029"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.1097\/00005131-200106000-00007"},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.1007\/s001130050307"},{"key":"ref27","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199805000-00004"},{"key":"ref28","doi-asserted-by":"publisher","DOI":"10.1097\/bot.0b013e31815928c2"},{"key":"ref29","doi-asserted-by":"publisher","DOI":"10.1155\/2018\/4184190"},{"key":"ref30","first-page":"102","volume-title":"The effect of smoking on bone healing: a systematic review","author":"Patel","year":"2013"},{"key":"ref31","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0225539"},{"key":"ref32","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-198163060-00002"},{"key":"ref33","doi-asserted-by":"publisher","DOI":"10.1007\/s00776-005-0984-7"},{"key":"ref34","doi-asserted-by":"publisher","DOI":"10.1097\/bot.0b013e31818df8cb"},{"key":"ref35","doi-asserted-by":"publisher","DOI":"10.1016\/s0020-1383(98)95006-9"},{"key":"ref36","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2015.07.032"}],"container-title":["Clinics in Shoulder and Elbow"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/cisejournal.org\/upload\/pdf\/cise-2024-00423.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/cisejournal.org\/journal\/view.php?doi=10.5397\/cise.2024.00423","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/cisejournal.org\/upload\/pdf\/cise-2024-00423.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,12,2]],"date-time":"2024-12-02T04:59:24Z","timestamp":1733115564000},"score":1,"resource":{"primary":{"URL":"http:\/\/cisejournal.org\/journal\/view.php?doi=10.5397\/cise.2024.00423"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,1]]},"references-count":36,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2024,12]]}},"URL":"https:\/\/doi.org\/10.5397\/cise.2024.00423","relation":{},"ISSN":["2288-8721"],"issn-type":[{"type":"electronic","value":"2288-8721"}],"subject":[],"published":{"date-parts":[[2024,12,1]]},"assertion":[{"value":"2024-05-22","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-07-29","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-11-08","order":2,"name":"published","label":"Published online","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-12-01","order":3,"name":"published","label":"Print publication","group":{"name":"publication_history","label":"Publication History"}}]}}