{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T15:28:21Z","timestamp":1787671701159,"version":"build-2736575974"},"reference-count":40,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Am Acad Orthop Surg","JAAOS"],"published-print":{"date-parts":[[2017,4]]},"abstract":"<jats:p>As the number of primary total hip arthroplasties increases, so does the burden of revision procedures. The decision to revise well-fixed components in the setting of polyethylene wear and osteolysis is controversial. Modular head and liner exchange offers the advantages of reduced invasiveness, faster recovery, and bone preservation. These advantages come at the expense of higher rates of revision surgery for instability. Using the native locking mechanism for securing the new liner is preferred; however, cementing a liner into a well-fixed acetabular component is a practical alternative. The use of bone allograft or bone graft substitute for areas of osteolysis is controversial. In the setting of osteolysis, outcomes associated with the use of highly cross-linked polyethylene liners have been better than those associated with the use of conventional polyethylene; therefore, thinner liners and larger femoral heads can be used and reduce the risk of instability.<\/jats:p>","DOI":"10.5435\/jaaos-d-15-00144","type":"journal-article","created":{"date-parts":[[2017,3,14]],"date-time":"2017-03-14T10:49:12Z","timestamp":1489488552000},"page":"288-296","source":"Crossref","is-referenced-by-count":27,"title":["Isolated Head and Liner Exchange in Revision Hip Arthroplasty"],"prefix":"10.5435","volume":"25","author":[{"given":"David William","family":"Walmsley","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James P.","family":"Waddell","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emil H.","family":"Schemitsch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"issue":"6","key":"R1-20230714","doi-asserted-by":"crossref","first-page":"2131","DOI":"10.1007\/s11999-014-4078-8","article-title":"Comparative epidemiology of revision arthroplasty: Failed THA poses greater clinical and economic burdens than failed TKA","volume":"473","author":"Bozic","year":"2015","journal-title":"Clin Orthop Relat Res"},{"issue":"suppl 1","key":"R2-20230714","doi-asserted-by":"crossref","first-page":"12","DOI":"10.2106\/JBJS.N.00461","article-title":"Effect of femoral head size on metal-on-HXLPE hip arthroplasty outcome in a combined analysis of six national and regional registries","volume":"96","author":"Allepuz","year":"2014","journal-title":"J Bone Joint Surg Am"},{"issue":"4 suppl 1","key":"R3-20230714","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1016\/j.arth.2004.02.019","article-title":"Surgical management of polyethylene wear and pelvic osteolysis with modular uncemented acetabular components","volume":"19","author":"Naudie","year":"2004","journal-title":"J Arthroplasty"},{"issue":"6","key":"R4-20230714","doi-asserted-by":"crossref","first-page":"798","DOI":"10.1054\/arth.2002.32705","article-title":"Polyethylene liner exchange for excessive wear and osteolysis","volume":"17","author":"Terefenko","year":"2002","journal-title":"J Arthroplasty"},{"issue":"2","key":"R5-20230714","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1007\/s11999-015-4319-5","article-title":"Wear and osteolysis of highly crosslinked polyethylene at 10 to 14 Years: The effect of femoral head size","volume":"474","author":"Lachiewicz","year":"2016","journal-title":"Clin Orthop Relat Res"},{"issue":"11","key":"R6-20230714","doi-asserted-by":"crossref","first-page":"3164","DOI":"10.1007\/s11999-012-2500-7","article-title":"Aggressive early d\u00e9bridement for treatment of acutely infected cemented total hip arthroplasty","volume":"470","author":"Sukeik","year":"2012","journal-title":"Clin Orthop Relat Res"},{"issue":"447","key":"R7-20230714","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1097\/01.blo.0000218751.14989.a6","article-title":"Revision hip arthroplasty for late instability secondary to polyethylene wear","volume":"447","author":"Parvizi","year":"2006","journal-title":"Clin Orthop Relat Res"},{"issue":"11","key":"R8-20230714","doi-asserted-by":"crossref","first-page":"2992","DOI":"10.1007\/s11999-011-2102-9","article-title":"New definition for periprosthetic joint infection: From the workgroup of the Musculoskeletal Infection Society","volume":"469","author":"Parvizi","year":"2011","journal-title":"Clin Orthop Relat Res"},{"key":"R9-20230714","first-page":"20","article-title":"Radiological demarcation of cemented sockets in total hip replacement","volume":"121","author":"DeLee","year":"1976","journal-title":"Clin Orthop Relat Res"},{"key":"R10-20230714","first-page":"17","article-title":"\u201cModes of failure\u201d of cemented stem-type femoral components: A radiographic analysis of loosening","volume":"141","author":"Gruen","year":"1979","journal-title":"Clin Orthop Relat Res"},{"issue":"2","key":"R11-20230714","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1302\/0301-620X.81B2.0810289","article-title":"Improving the detection of acetabular osteolysis using oblique radiographs","volume":"81","author":"Southwell","year":"1999","journal-title":"J Bone Joint Surg Br"},{"issue":"12","key":"R12-20230714","doi-asserted-by":"crossref","first-page":"2288","DOI":"10.2106\/00004623-200312000-00004","article-title":"Fate of cementless acetabular components retained during revision total hip arthroplasty","volume":"85-A","author":"Beaul\u00e9","year":"2003","journal-title":"J Bone Joint Surg Am"},{"key":"R13-20230714","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1097\/01.blo.0000164028.14504.46","article-title":"Comparison of CT, MRI, and radiographs in assessing pelvic osteolysis: A cadaveric study","volume":"437","author":"Walde","year":"2005","journal-title":"Clin Orthop Relat Res"},{"issue":"10","key":"R14-20230714","first-page":"2323","article-title":"Radiographic methods for the assessment of polyethylene wear after total hip arthroplasty","volume":"87","author":"McCalden","year":"2005","journal-title":"J Bone Joint Surg Am"},{"issue":"5","key":"R15-20230714","doi-asserted-by":"crossref","first-page":"775","DOI":"10.1016\/j.arth.2008.05.027","article-title":"Cementation of a polyethylene liner into a metal acetabular shell: A biomechanical study","volume":"24","author":"Hofmann","year":"2009","journal-title":"J Arthroplasty"},{"issue":"6","key":"R16-20230714","doi-asserted-by":"crossref","first-page":"1041","DOI":"10.1016\/j.arth.2015.01.041","article-title":"Long term results of liner polyethylene cementation technique in revision for peri-acetabular osteolysis","volume":"30","author":"Rivkin","year":"2015","journal-title":"J Arthroplasty"},{"issue":"9 suppl","key":"R17-20230714","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1016\/j.arth.2014.03.055","article-title":"Do you have to remove a corroded femoral stem?","volume":"29","author":"Goyal","year":"2014","journal-title":"J Arthroplasty"},{"issue":"12","key":"R18-20230714","doi-asserted-by":"crossref","first-page":"3674","DOI":"10.1007\/s11999-014-3652-4","article-title":"The surgical options and clinical evidence for treatment of wear or corrosion occurring with THA or TKA","volume":"472","author":"Engh","year":"2014","journal-title":"Clin Orthop Relat Res"},{"issue":"4","key":"R19-20230714","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1053\/j.sart.2013.01.013","article-title":"Biologic implications of taper corrosion in total hip arthroplasty","volume":"23","author":"Cooper","year":"2012","journal-title":"Semin Arthroplasty"},{"issue":"5","key":"R20-20230714","doi-asserted-by":"crossref","first-page":"949","DOI":"10.1007\/s00264-011-1372-x","article-title":"Retention of a well-fixed acetabular component in the setting of acetabular osteolysis","volume":"36","author":"Kang","year":"2012","journal-title":"Int Orthop"},{"issue":"5","key":"R21-20230714","doi-asserted-by":"crossref","first-page":"654","DOI":"10.1016\/S0883-5403(03)00266-3","article-title":"Dislocation after polyethylene liner exchange in total hip arthroplasty","volume":"18","author":"Boucher","year":"2003","journal-title":"J Arthroplasty"},{"issue":"7 suppl 2","key":"R22-20230714","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1016\/j.arth.2004.06.014","article-title":"Early morbidity of modular exchange for polyethylene wear and osteolysis","volume":"19","author":"Griffin","year":"2004","journal-title":"J Arthroplasty"},{"key":"R23-20230714","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1097\/01.blo.0000194091.10447.79","article-title":"Isolated liner exchange using the anterolateral approach is associated with a low risk of dislocation","volume":"441","author":"Smith","year":"2005","journal-title":"Clin Orthop Relat Res"},{"issue":"5","key":"R24-20230714","doi-asserted-by":"crossref","first-page":"929","DOI":"10.2106\/00004623-200405000-00007","article-title":"Cementing a liner into a stable cementless acetabular shell: The double-socket technique","volume":"86-A","author":"Beaul\u00e9","year":"2004","journal-title":"J Bone Joint Surg Am"},{"issue":"2","key":"R25-20230714","doi-asserted-by":"crossref","first-page":"624","DOI":"10.1007\/s11999-013-3153-x","article-title":"Short-term wear evaluation of thin acetabular liners on 36-mm femoral heads","volume":"472","author":"Johnson","year":"2014","journal-title":"Clin Orthop Relat Res"},{"issue":"4","key":"R26-20230714","doi-asserted-by":"crossref","first-page":"681","DOI":"10.1007\/s00264-015-2841-4","article-title":"Is the use of thin, highly cross-linked polyethylene liners safe in total hip arthroplasty?","volume":"40","author":"Jauregui","year":"2016","journal-title":"Int Orthop"},{"issue":"3","key":"R27-20230714","doi-asserted-by":"crossref","first-page":"342","DOI":"10.1177\/230949901402200315","article-title":"Total hip replacement using a highly crosslinked polyethylene liner in Asians with small acetabulum","volume":"22","author":"Chua","year":"2014","journal-title":"J Orthop Surg (Hong Kong)"},{"issue":"12","key":"R28-20230714","doi-asserted-by":"crossref","first-page":"3652","DOI":"10.1007\/s11999-014-3746-z","article-title":"What is the trouble with trunnions?","volume":"472","author":"Esposito","year":"2014","journal-title":"Clin Orthop Relat Res"},{"issue":"6","key":"R29-20230714","doi-asserted-by":"crossref","first-page":"1100","DOI":"10.2106\/00004623-200306000-00019","article-title":"A biomechanical analysis of polyethylene liner cementation into a fixed metal acetabular shell","volume":"85-A","author":"Haft","year":"2003","journal-title":"J Bone Joint Surg Am"},{"issue":"6 suppl","key":"R30-20230714","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1016\/j.arth.2009.05.004","article-title":"Polyethylene exchange in a second-generation cementless acetabular component","volume":"24","author":"Archibeck","year":"2009","journal-title":"J Arthroplasty"},{"issue":"1","key":"R31-20230714","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1007\/s11999-008-0533-8","article-title":"Isolated polyethylene exchange versus acetabular revision for polyethylene wear","volume":"467","author":"Restrepo","year":"2009","journal-title":"Clin Orthop Relat Res"},{"issue":"6 suppl","key":"R32-20230714","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1016\/j.arth.2010.04.004","article-title":"Survivorship of polyethylene liner exchanges performed for the treatment of wear and osteolysis among porous-coated cups","volume":"25","author":"Hamilton","year":"2010","journal-title":"J Arthroplasty"},{"issue":"1","key":"R33-20230714","doi-asserted-by":"crossref","first-page":"61","DOI":"10.5301\/hipint.5000191","article-title":"Outcomes of polyethylene liner cementation into a fixed metal acetabular shell with minimum follow-up of 7 years","volume":"25","author":"Park","year":"2015","journal-title":"Hip Int"},{"issue":"9","key":"R34-20230714","doi-asserted-by":"crossref","DOI":"10.3928\/01477447-20090728-17","article-title":"Shell retention with a cemented acetabular liner","volume":"32","author":"Callaghan","year":"2009","journal-title":"Orthopedics"},{"issue":"12","key":"R35-20230714","doi-asserted-by":"crossref","first-page":"1015","DOI":"10.2106\/JBJS.L.01177","article-title":"Revision total hip arthroplasty with retained acetabular component","volume":"96","author":"Adelani","year":"2014","journal-title":"J Bone Joint Surg Am"},{"issue":"5","key":"R36-20230714","doi-asserted-by":"crossref","first-page":"591","DOI":"10.1302\/0301-620X.89B5.18623","article-title":"Isolated acetabular liner exchange compared with complete acetabular component revision in revision of primary uncemented acetabular components: A study of 1649 revisions from the Norwegian Arthroplasty Register","volume":"89","author":"Lie","year":"2007","journal-title":"J Bone Joint Surg Br"},{"issue":"4","key":"R37-20230714","doi-asserted-by":"crossref","first-page":"576","DOI":"10.1016\/j.arth.2010.05.028","article-title":"Management of polyethylene wear associated with a well-fixed modular cementless shell during revision total hip arthroplasty","volume":"26","author":"Talmo","year":"2011","journal-title":"J Arthroplasty"},{"issue":"11 suppl A","key":"R38-20230714","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1302\/0301-620X.96B11.34452","article-title":"The revision acetabulum\u2014allograft and bone substitutes: Vestigial organs for bone deficiency","volume":"96-B","author":"Callaghan","year":"2014","journal-title":"Bone Joint J"},{"issue":"2","key":"R39-20230714","doi-asserted-by":"crossref","first-page":"480","DOI":"10.1007\/s11999-009-1050-0","article-title":"A three-dimensional method for evaluating changes in acetabular osteolytic lesions in response to treatment","volume":"468","author":"Egawa","year":"2010","journal-title":"Clin Orthop Relat Res"},{"key":"R40-20230714","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1097\/00003086-199805000-00018","article-title":"The fate of pelvic osteolysis after reoperation: No recurrence with lesional treatment","volume":"350","author":"Schmalzried","year":"1998","journal-title":"Clin Orthop Relat Res"}],"container-title":["Journal of the American Academy of Orthopaedic Surgeons"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/00124635-201704000-00005","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T14:47:51Z","timestamp":1787669271000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/00124635-201704000-00005"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,4]]},"references-count":40,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.5435\/jaaos-d-15-00144","relation":{},"ISSN":["1067-151X","1940-5480"],"issn-type":[{"value":"1067-151X","type":"print"},{"value":"1940-5480","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,4]]}}}