{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,5]],"date-time":"2026-09-05T23:12:44Z","timestamp":1788649964538,"version":"build-2803163510"},"reference-count":42,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Am Acad Orthop Surg","JAAOS"],"published-print":{"date-parts":[[2016,10]]},"abstract":"<jats:p>Stress modulation is the concept of manipulating bridge plate variables to provide a flexible fixation construct that allows callus formation through uneventful secondary bone healing. Obtaining absolute stability through the anatomic reduction of all fracture fragments comes at the expense of fracture biology, whereas intramedullary nailing, which is more advantageous for diaphyseal fractures of the lower extremity, is technically demanding and often may not be possible when stabilizing many metaphyseal fractures. Overly stiff plating constructs are associated with asymmetric callus formation, early implant failure, and fracture nonunion. Numerous surgeon-controlled variables can be manipulated to increase flexibility without sacrificing strength, including using longer plates with well-spaced screws, choosing titanium or stainless steel implants, and using locking or nonlocking screws. Axially dynamic emerging concepts, such as far cortical locking and near cortical overdrilling, provide further treatment options when bridge plating techniques are used.<\/jats:p>","DOI":"10.5435\/jaaos-d-15-00175","type":"journal-article","created":{"date-parts":[[2016,8,30]],"date-time":"2016-08-30T16:08:01Z","timestamp":1472573281000},"page":"711-719","source":"Crossref","is-referenced-by-count":64,"title":["Stress Modulation of Fracture Fixation Implants"],"prefix":"10.5435","volume":"24","author":[{"given":"Michael J.","family":"Beltran","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cory A.","family":"Collinge","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael J.","family":"Gardner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"issue":"2","key":"R1-20230714","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1097\/BOT.0b013e31829e6dd0","article-title":"Risk factors for failure of locked plate fixation of distal femur fractures: An analysis of 335 cases","volume":"28","author":"Ricci","year":"2014","journal-title":"J Orthop Trauma"},{"issue":"suppl 1","key":"R2-20230714","doi-asserted-by":"crossref","first-page":"S8","DOI":"10.1097\/BOT.0b013e3182070127","article-title":"Locking plates for distal femur fractures: Is there a problem with fracture healing?","volume":"25","author":"Henderson","year":"2011","journal-title":"J Orthop Trauma"},{"issue":"3","key":"R3-20230714","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1097\/BOT.0b013e3181be6720","article-title":"Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation","volume":"24","author":"Lujan","year":"2010","journal-title":"J Orthop Trauma"},{"issue":"7","key":"R4-20230714","doi-asserted-by":"crossref","first-page":"1575","DOI":"10.2106\/00004623-200707000-00022","article-title":"Timely fracture-healing requires optimization of axial fixation stability","volume":"89","author":"Epari","year":"2007","journal-title":"J Bone Joint Surg Am"},{"issue":"8","key":"R5-20230714","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1302\/0301-620X.84B8.0841093","article-title":"Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: Choosing a new balance between stability and biology","volume":"84","author":"Perren","year":"2002","journal-title":"J Bone Joint Surg Br"},{"issue":"339","key":"R6-20230714","doi-asserted-by":"crossref","first-page":"232","DOI":"10.1097\/00003086-199706000-00032","article-title":"Improved fracture healing with less rigid plates: A biomechanical study in dogs","author":"Foux","year":"1997","journal-title":"Clin Orthop Relat Res"},{"issue":"1","key":"R7-20230714","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1007\/BF02563988","article-title":"Quantitative histological evaluation of early fracture healing of cortical bones immobilized by stainless steel and composite plates","volume":"19","author":"Akeson","year":"1975","journal-title":"Calcif Tissue Res"},{"issue":"3","key":"R8-20230714","doi-asserted-by":"crossref","first-page":"241","DOI":"10.3109\/17453677608991984","article-title":"The effects of rigidity of internal fixation plates on long bone remodeling: A biomechanical and quantitative histological study","volume":"47","author":"Akeson","year":"1976","journal-title":"Acta Orthop Scand"},{"issue":"232","key":"R9-20230714","first-page":"139","article-title":"Early temporary porosis of bone induced by internal fixation implants: A reaction to necrosis, not to stress protection?","author":"Perren","year":"1988","journal-title":"Clin Orthop Relat Res"},{"issue":"241","key":"R10-20230714","first-page":"24","article-title":"The effect of rigidity on fracture healing in external fixation","author":"Chao","year":"1989","journal-title":"Clin Orthop Relat Res"},{"issue":"8517","key":"R11-20230714","doi-asserted-by":"crossref","first-page":"1185","DOI":"10.1016\/S0140-6736(86)92196-3","article-title":"Effect of controlled axial micromovement on healing of tibial fractures","volume":"2","author":"Kenwright","year":"1986","journal-title":"Lancet"},{"issue":"241","key":"R12-20230714","first-page":"36","article-title":"Controlled mechanical stimulation in the treatment of tibial fractures","author":"Kenwright","year":"1989","journal-title":"Clin Orthop Relat Res"},{"issue":"suppl 3","key":"R14-20230714","first-page":"C1","article-title":"Stress protection due to plates: Myth or reality? A parametric analysis made using the composite beam theory","volume":"31","author":"Cordey","year":"2000","journal-title":"Injury"},{"issue":"138","key":"R15-20230714","first-page":"175","article-title":"Physical and biological aspects of fracture healing with special reference to internal fixation","volume":"17","author":"Perren","year":"1979","journal-title":"Clin Orthop Relat Res"},{"issue":"3","key":"R16-20230714","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1016\/S0021-9290(98)00153-5","article-title":"Magnitudes of local stress and strain along bony surfaces predict the course and type of fracture healing","volume":"32","author":"Claes","year":"1999","journal-title":"J Biomech"},{"key":"R17-20230714","article-title":"Biomechanical investigation of plate working length on fatigue characteristics of locking plate constructs in cadaveric distal metadiaphyseal femoral fracture models","author":"Ricci"},{"issue":"10","key":"R18-20230714","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1097\/BOT.0000000000000315","article-title":"Dynamic locked plating of distal femur fractures","volume":"29","author":"Linn","year":"2015","journal-title":"J Orthop Trauma"},{"issue":"6","key":"R19-20230714","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1097\/BOT.0b013e318178417e","article-title":"Biomechanical comparison of bicortical versus unicortical screw placement of proximal tibia locking plates: A cadaveric model","volume":"22","author":"Dougherty","year":"2008","journal-title":"J Orthop Trauma"},{"issue":"8","key":"R20-20230714","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1097\/00005131-200409000-00006","article-title":"Treatment of distal femur fractures using the less invasive stabilization system: Surgical experience and early clinical results in 103 fractures","volume":"18","author":"Kregor","year":"2004","journal-title":"J Orthop Trauma"},{"issue":"8","key":"R21-20230714","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1097\/00005131-200409000-00005","article-title":"Early results of the less invasive stabilization system for mechanically unstable fractures of the distal femur (AO\/OTA types A2, A3, C2, and C3)","volume":"18","author":"Weight","year":"2004","journal-title":"J Orthop Trauma"},{"issue":"8","key":"R22-20230714","doi-asserted-by":"crossref","first-page":"571","DOI":"10.1097\/00005131-200409000-00016","article-title":"Locking compression plate loosening and plate breakage: A report of four cases","volume":"18","author":"Sommer","year":"2004","journal-title":"J Orthop Trauma"},{"issue":"8","key":"R23-20230714","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1097\/00005131-200409000-00015","article-title":"Failure of less invasive stabilization system plates in the distal femur: A report of four cases","volume":"18","author":"Button","year":"2004","journal-title":"J Orthop Trauma"},{"issue":"9","key":"R25-20230714","first-page":"1962","article-title":"Hybrid locked plating of osteoporotic fractures of the humerus","volume":"88","author":"Gardner","year":"2006","journal-title":"J Bone Joint Surg Am"},{"issue":"3","key":"R26-20230714","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1097\/BOT.0b013e3181d35c29","article-title":"How much do locked screws add to the fixation of \u201chybrid\u201d plate constructs in osteoporotic bone?","volume":"24","author":"Freeman","year":"2010","journal-title":"J Orthop Trauma"},{"issue":"2","key":"R27-20230714","first-page":"411","article-title":"Effects of hybrid plating with locked and nonlocked screws on the strength of locked plating constructs in the osteoporotic diaphysis","volume":"69","author":"Doornink","year":"2010","journal-title":"J Trauma"},{"issue":"3","key":"R28-20230714","doi-asserted-by":"crossref","first-page":"620","DOI":"10.2106\/JBJS.H.00408","article-title":"A nonlocking end screw can decrease fracture risk caused by locked plating in the osteoporotic diaphysis","volume":"91","author":"Bottlang","year":"2009","journal-title":"J Bone Joint Surg Am"},{"issue":"3","key":"R29-20230714","doi-asserted-by":"crossref","first-page":"166","DOI":"10.1097\/00005131-200203000-00005","article-title":"Minimal versus maximal plate fixation techniques of the ulna: The biomechanical effect of number of screws and plate length","volume":"16","author":"Sanders","year":"2002","journal-title":"J Orthop Trauma"},{"issue":"suppl 2","key":"R30-20230714","doi-asserted-by":"crossref","first-page":"B31","DOI":"10.1016\/j.injury.2003.09.023","article-title":"General principles for the clinical use of the LCP","volume":"34","author":"Wagner","year":"2003","journal-title":"Injury"},{"issue":"354","key":"R31-20230714","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1097\/00003086-199809000-00024","article-title":"The evolution of femoral shaft plating technique","author":"Rozbruch","year":"1998","journal-title":"Clin Orthop Relat Res"},{"issue":"suppl 2","key":"R32-20230714","doi-asserted-by":"crossref","first-page":"B11","DOI":"10.1016\/j.injury.2003.09.021","article-title":"Biomechanical testing of the LCP: How can stability in locked internal fixators be controlled?","volume":"34","author":"Stoffel","year":"2003","journal-title":"Injury"},{"issue":"3","key":"R33-20230714","doi-asserted-by":"crossref","first-page":"204","DOI":"10.1097\/00005131-199604000-00009","article-title":"The strength of plate fixation in relation to the number and spacing of bone screws","volume":"10","author":"T\u00f6rnkvist","year":"1996","journal-title":"J Orthop Trauma"},{"issue":"3","key":"R34-20230714","doi-asserted-by":"crossref","first-page":"554","DOI":"10.1016\/j.injury.2013.10.042","article-title":"Predictive factors of distal femoral fracture nonunion after lateral locked plating: A retrospective multicenter case-control study of 283 fractures","volume":"45","author":"Rodriguez","year":"2014","journal-title":"Injury"},{"issue":"2","key":"R35-20230714","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1097\/BOT.0b013e3181dc56b1","article-title":"Threaded screw head inserts improve locking plate biomechanical properties","volume":"25","author":"Bellapianta","year":"2011","journal-title":"J Orthop Trauma"},{"issue":"6","key":"R36-20230714","doi-asserted-by":"crossref","first-page":"652","DOI":"10.1016\/j.injury.2010.02.022","article-title":"Less rigid stable fracture fixation in osteoporotic bone using locked plates with near cortical slots","volume":"41","author":"Gardner","year":"2010","journal-title":"Injury"},{"issue":"suppl 1","key":"R37-20230714","doi-asserted-by":"crossref","first-page":"S35","DOI":"10.1097\/BOT.0b013e3182070f2d","article-title":"Effects of near cortical slotted holes in locking plate constructs","volume":"25","author":"Sellei","year":"2011","journal-title":"J Orthop Trauma"},{"issue":"7","key":"R38-20230714","doi-asserted-by":"crossref","first-page":"1652","DOI":"10.2106\/JBJS.I.01111","article-title":"Far cortical locking can improve healing of fractures stabilized with locking plates","volume":"92","author":"Bottlang","year":"2010","journal-title":"J Bone Joint Surg Am"},{"issue":"suppl 1","key":"R39-20230714","doi-asserted-by":"crossref","first-page":"S29","DOI":"10.1097\/BOT.0b013e3182070cda","article-title":"Far cortical locking enables flexible fixation with periarticular locking plates","volume":"25","author":"Doornink","year":"2011","journal-title":"J Orthop Trauma"},{"issue":"4","key":"R40-20230714","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1097\/01.bot.0000438368.44077.04","article-title":"Dynamic fixation of distal femur fractures using far cortical locking screws: A prospective observational study","volume":"28","author":"Bottlang","year":"2014","journal-title":"J Orthop Trauma"},{"issue":"3","key":"R41-20230714","doi-asserted-by":"crossref","first-page":"208","DOI":"10.2106\/JBJS.M.00529","article-title":"Dynamization at the near cortex in locking plate osteosynthesis by means of dynamic locking screws: An experimental study of transverse tibial osteotomies in sheep","volume":"97","author":"Richter","year":"2015","journal-title":"J Bone Joint Surg Am"},{"issue":"4","key":"R42-20230714","doi-asserted-by":"crossref","first-page":"e91933","DOI":"10.1371\/journal.pone.0091933","article-title":"DLS 5.0: The biomechanical effects of dynamic locking screws","volume":"9","author":"D\u00f6bele","year":"2014","journal-title":"PLoS One"},{"issue":"6","key":"R43-20230714","doi-asserted-by":"crossref","first-page":"372","DOI":"10.1097\/00005131-199608000-00002","article-title":"The results of open reduction and internal fixation of distal femur fractures using a biologic (indirect) reduction technique","volume":"10","author":"Bolhofner","year":"1996","journal-title":"J Orthop Trauma"},{"issue":"4","key":"R44-20230714","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1097\/00005131-199509040-00002","article-title":"Indirect reduction and internal fixation of supracondylar femur fractures without bone graft","volume":"9","author":"Ostrum","year":"1995","journal-title":"J Orthop Trauma"}],"container-title":["Journal of the American Academy of Orthopaedic Surgeons"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/00124635-201610000-00006","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T14:47:33Z","timestamp":1787669253000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/00124635-201610000-00006"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,10]]},"references-count":42,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2016]]}},"URL":"https:\/\/doi.org\/10.5435\/jaaos-d-15-00175","relation":{},"ISSN":["1067-151X","1940-5480"],"issn-type":[{"value":"1067-151X","type":"print"},{"value":"1940-5480","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,10]]}}}