{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T15:28:03Z","timestamp":1787671683041,"version":"build-2736575974"},"reference-count":44,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Am Acad Orthop Surg","JAAOS"],"published-print":{"date-parts":[[2017,10]]},"abstract":"<jats:p>Allergic or hypersensitivity reactions to orthopaedic implants can pose diagnostic and therapeutic challenges. Although 10% to 15% of the population exhibits cutaneous sensitivity to metals, deep-tissue reactions to metal implants are comparatively rare. Nevertheless, the link between cutaneous sensitivity and clinically relevant deep-tissue reactions is unclear. Most reactions to orthopaedic devices are type IV, or delayed-type hypersensitivity reactions. The most commonly implicated allergens are nickel, cobalt, and chromium; however, reactions to nonmetal compounds, such as polymethyl methacrylate, antibiotic spacers, and suture materials, have also been reported. Symptoms of hypersensitivity to implants are nonspecific and include pain, swelling, stiffness, and localized skin reactions. Following arthroplasty, internal fixation, or implantation of similarly allergenic devices, the persistence or early reappearance of inflammatory symptoms should raise suspicions for hypersensitivity. However, hypersensitivity is a diagnosis of exclusion. Infection, as well as aseptic loosening, particulate synovitis, instability, and other causes of failure must first be eliminated.<\/jats:p>","DOI":"10.5435\/jaaos-d-16-00007","type":"journal-article","created":{"date-parts":[[2017,9,27]],"date-time":"2017-09-27T12:19:16Z","timestamp":1506514756000},"page":"693-702","source":"Crossref","is-referenced-by-count":41,"title":["Allergic or Hypersensitivity Reactions to Orthopaedic Implants"],"prefix":"10.5435","volume":"25","author":[{"given":"Timothy T.","family":"Roberts","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Colin M.","family":"Haines","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Richard L.","family":"Uhl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"issue":"6","key":"R1-20230714","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1007\/s40629-014-0023-3","article-title":"Clinical and diagnostic challenges of metal implant allergy using the example of orthopaedic surgical implants: Part 15 of the Series Molecular Allergology","volume":"23","author":"Thomas","year":"2014","journal-title":"Allergo J Int"},{"issue":"3","key":"R2-20230714","doi-asserted-by":"crossref","first-page":"428","DOI":"10.2106\/00004623-200103000-00017","article-title":"Metal sensitivity in patients with orthopaedic implants","volume":"83","author":"Hallab","year":"2001","journal-title":"J Bone Joint Surg Am"},{"issue":"12","key":"R3-20230714","doi-asserted-by":"crossref","first-page":"724","DOI":"10.5435\/JAAOS-D-14-00183","article-title":"Metal-on-metal total hip arthroplasty: Patient evaluation and treatment","volume":"23","author":"Bolognesi","year":"2015","journal-title":"J Am Acad Orthop Surg"},{"issue":"12","key":"R4-20230714","first-page":"749561","article-title":"Metal allergy and systemic contact dermatitis: An overview","volume":"2012","author":"Yoshihisa","year":"2012","journal-title":"Dermatol Res Pract"},{"issue":"1","key":"R5-20230714","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1097\/DER.0000000000000091","article-title":"Hypersensitivity reactions to titanium: Diagnosis and management","volume":"26","author":"Wood","year":"2015","journal-title":"Dermatitis"},{"issue":"5","key":"R7-20230714","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1111\/j.1600-0536.2007.01220.x","article-title":"The epidemiology of contact allergy in the general population: Prevalence and main findings","volume":"57","author":"Thyssen","year":"2007","journal-title":"Contact Dermatitis"},{"issue":"2","key":"R8-20230714","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.det.2008.11.003","article-title":"Prevention of nickel allergy: The case for regulation?","volume":"27","author":"Lu","year":"2009","journal-title":"Dermatol Clin"},{"issue":"2","key":"R10-20230714","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1021\/tx9002726","article-title":"Metal allergy: A review on exposures, penetration, genetics, prevalence, and clinical implications","volume":"23","author":"Thyssen","year":"2010","journal-title":"Chem Res Toxicol"},{"issue":"4","key":"R12-20230714","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1111\/j.1440-0960.2010.00664.x","article-title":"Type 1 and type IV hypersensitivity to nickel","volume":"51","author":"Walsh","year":"2010","journal-title":"Australas J Dermatol"},{"issue":"1","key":"R13-20230714","doi-asserted-by":"crossref","first-page":"9","DOI":"10.2310\/6620.2008.06069","article-title":"Systemic contact dermatitis","volume":"19","author":"Jacob","year":"2008","journal-title":"Dermatitis"},{"issue":"3","key":"R14-20230714","doi-asserted-by":"crossref","first-page":"420","DOI":"10.1002\/jbm.10106","article-title":"Concentration- and composition-dependent effects of metal ions on human MG-63 osteoblasts","volume":"60","author":"Hallab","year":"2002","journal-title":"J Biomed Mater Res"},{"issue":"12","key":"R15-20230714","doi-asserted-by":"crossref","first-page":"3665","DOI":"10.1007\/s11999-014-3579-9","article-title":"What are the advantages and disadvantages of imaging modalities to diagnose wear-related corrosion problems?","volume":"472","author":"Nam","year":"2014","journal-title":"Clin Orthop Relat Res"},{"issue":"1","key":"R16-20230714","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1007\/s12178-016-9321-3","article-title":"Diagnosis of adverse local tissue reactions following metal-on-metal hip arthroplasty","volume":"9","author":"Chalmers","year":"2016","journal-title":"Curr Rev Musculoskelet Med"},{"issue":"23","key":"R17-20230714","doi-asserted-by":"crossref","first-page":"2164","DOI":"10.2106\/JBJS.J.01884","article-title":"Prevalence of pseudotumor in asymptomatic patients after metal-on-metal hip arthroplasty","volume":"93","author":"Williams","year":"2011","journal-title":"J Bone Joint Surg Am"},{"issue":"12","key":"R18-20230714","doi-asserted-by":"crossref","first-page":"2239","DOI":"10.1016\/j.arth.2014.04.030","article-title":"Is ultrasound screening reliable for adverse local tissue reaction after hip arthroplasty?","volume":"29","author":"Nishii","year":"2014","journal-title":"J Arthroplasty"},{"issue":"10","key":"R19-20230714","doi-asserted-by":"crossref","first-page":"1308","DOI":"10.1302\/0301-620X.93B10.26249","article-title":"Sensitivity and specificity of blood cobalt and chromium metal ions for predicting failure of metal-on-metal hip replacement","volume":"93","author":"Hart","year":"2011","journal-title":"J Bone Joint Surg Br"},{"issue":"1","key":"R20-20230714","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1186\/s12891-015-0851-4","article-title":"Diagnostic utility of joint fluid metal ion measurement for histopathological findings in metal-on-metal hip replacements","volume":"16","author":"Reito","year":"2015","journal-title":"BMC Musculoskelet Disord"},{"issue":"2","key":"R21-20230714","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1111\/j.1600-0536.1985.tb01060.x","article-title":"False-positive, follicular and irritant patch test reactions to metal salts","volume":"12","author":"Fischer","year":"1985","journal-title":"Contact Dermatitis"},{"issue":"6","key":"R22-20230714","first-page":"1171","article-title":"Loosening and osteolysis associated with metal-on-metal bearings: A local effect of metal hypersensitivity?","volume":"88","author":"Jacobs","year":"2006","journal-title":"J Bone Joint Surg Am"},{"issue":"4","key":"R23-20230714","doi-asserted-by":"crossref","first-page":"616","DOI":"10.1067\/mjd.2001.110873","article-title":"Flare-up reactions after oral challenge with nickel in relation to challenge dose and intensity and time of previous patch test reactions","volume":"44","author":"Hinds\u00e9n","year":"2001","journal-title":"J Am Acad Dermatol"},{"issue":"7","key":"R24-20230714","doi-asserted-by":"crossref","first-page":"E492","DOI":"10.1097\/BRS.0b013e31820ea9a2","article-title":"Early failure of metal-on-metal artificial disc prostheses associated with lymphocytic reaction: Diagnosis and treatment experience in four cases","volume":"36","author":"Guyer","year":"2011","journal-title":"Spine (Phila Pa 1976)"},{"issue":"1","key":"R25-20230714","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1111\/j.1600-0536.2011.01971.x","article-title":"Hypersensitivity reactions to metallic implants: Diagnostic algorithm and suggested patch test series for clinical use","volume":"66","author":"Schalock","year":"2012","journal-title":"Contact Dermatitis"},{"issue":"2","key":"R26-20230714","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1111\/j.1600-0536.2011.01970.x","article-title":"Metal allergy and second-generation metal-on-metal arthroplasties","volume":"66","author":"Cousen","year":"2012","journal-title":"Contact Dermatitis"},{"issue":"1","key":"R27-20230714","first-page":"62","article-title":"Implantation of orthopaedic devices in patients with metal allergy","volume":"69","author":"Carlsson","year":"1989","journal-title":"Acta Derm Venereol"},{"issue":"2","key":"R28-20230714","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1007\/s00264-015-3001-6","article-title":"Allergic reactions in arthroplasty: Myth or serious problem?","volume":"40","author":"Guenther","year":"2016","journal-title":"Int Orthop"},{"issue":"12","key":"R29-20230714","doi-asserted-by":"crossref","first-page":"e49","DOI":"10.2106\/JBJS.15.01082","article-title":"Eighty-six percent failure rate of a modular-neck femoral stem design at 3 to 5 years: Lessons learned","volume":"98","author":"Bernstein","year":"2016","journal-title":"J Bone Joint Surg Am"},{"issue":"2","key":"R30-20230714","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1302\/0301-620X.94B2.27247","article-title":"Mixing and matching causing taper wear: Corrosion associated with pseudotumour formation","volume":"94","author":"Chana","year":"2012","journal-title":"J Bone Joint Surg Br"},{"issue":"1","key":"R32-20230714","doi-asserted-by":"crossref","first-page":"40","DOI":"10.2106\/JBJS.N.01121","article-title":"Comprehensive analysis of a recalled modular total hip system and recommendations for management","volume":"98","author":"Nawabi","year":"2016","journal-title":"J Bone Joint Surg Am"},{"issue":"3","key":"R33-20230714","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1007\/s00256-014-1978-3","article-title":"Trunnionosis: The latest culprit in adverse reactions to metal debris following hip arthroplasty","volume":"44","author":"Shulman","year":"2015","journal-title":"Skeletal Radiol"},{"issue":"2","key":"R34-20230714","doi-asserted-by":"crossref","first-page":"375.e5","DOI":"10.1016\/j.arth.2012.04.005","article-title":"Adverse local tissue response lesion of the knee associated with Morse taper corrosion","volume":"28","author":"McMaster","year":"2013","journal-title":"J Arthroplasty"},{"issue":"1","key":"R35-20230714","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1111\/j.1468-3083.1993.tb00005.x","article-title":"Orthopaedic metallic implants in extremity fractures and contact allergy","volume":"2","author":"Hindsen","year":"1993","journal-title":"J Eur Acad Dermatol Venereol"},{"issue":"2","key":"R36-20230714","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1097\/00005131-200102000-00002","article-title":"Cutaneous metal sensitivity in patients with orthopaedic injuries","volume":"15","author":"Swiontkowski","year":"2001","journal-title":"J Orthop Trauma"},{"issue":"4","key":"R37-20230714","doi-asserted-by":"crossref","first-page":"320","DOI":"10.1016\/S0002-9610(98)00197-4","article-title":"Are allergic reactions to skin clips associated with delayed wound healing?","volume":"176","author":"Lhotka","year":"1998","journal-title":"Am J Surg"},{"issue":"4","key":"R38-20230714","doi-asserted-by":"crossref","first-page":"546","DOI":"10.1302\/0301-620X.78B4.0780546","article-title":"Hypersensitivity in aseptic loosening of total hip replacements: The role of constituents of bone cement","volume":"78","author":"Haddad","year":"1996","journal-title":"J Bone Joint Surg Br"},{"issue":"1","key":"R39-20230714","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1111\/j.1600-0536.2011.01996.x","article-title":"Allergic complications from orthopaedic joint implants: The role of delayed hypersensitivity to benzoyl peroxide in bone cement","volume":"66","author":"Bricher","year":"2012","journal-title":"Contact Dermat"},{"issue":"6","key":"R40-20230714","doi-asserted-by":"crossref","first-page":"825","DOI":"10.1302\/0301-620X.74B6.1447242","article-title":"Lymphocyte response to polymethylmethacrylate in loose total hip prostheses","volume":"74","author":"Gil-Albarova","year":"1992","journal-title":"J Bone Joint Surg Br"},{"issue":"7","key":"R41-20230714","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1016\/j.spinee.2015.04.011","article-title":"Polyetheretherketone (PEEK) intervertebral cage as a cause of chronic systemic allergy: A case report","volume":"15","author":"Maldonado-Naranjo","year":"2015","journal-title":"Spine J"},{"issue":"371","key":"R42-20230714","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1097\/00003086-200002000-00026","article-title":"Adverse tissue reactions to bioabsorbable fixation devices","author":"B\u00f6stman","year":"2000","journal-title":"Clin Orthop Relat Res"},{"issue":"4","key":"R44-20230714","doi-asserted-by":"crossref","first-page":"204","DOI":"10.2310\/6620.2006.06014","article-title":"Triclosan","volume":"17","author":"Campbell","year":"2006","journal-title":"Dermatitis"},{"issue":"11","key":"R45-20230714","doi-asserted-by":"crossref","first-page":"828","DOI":"10.3928\/01477447-20090922-11","article-title":"Biologic response to orthopedic sutures: A histologic study in a rabbit model","volume":"32","author":"Carr","year":"2009","journal-title":"Orthopedics"},{"issue":"4","key":"R46-20230714","first-page":"183","article-title":"Allergic contact dermatitis to 2-octyl cyanoacrylate","volume":"94","author":"Bowen","year":"2014","journal-title":"Curtis"},{"issue":"2","key":"R47-20230714","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1097\/DER.0000000000000018","article-title":"Allergic contact dermatitis to dermabond (2-octyl cyanoacrylate) after total knee arthroplasty","volume":"25","author":"Durando","year":"2014","journal-title":"Dermatitis"},{"issue":"1","key":"R48-20230714","doi-asserted-by":"crossref","first-page":"e4","DOI":"10.2106\/JBJS.M.00160","article-title":"Risk stratification algorithm for management of patients with metal-on-metal hip arthroplasty: Consensus statement of the American Association of Hip and Knee Surgeons, the American Academy of Orthopaedic Surgeons, and the Hip Society","volume":"96","author":"Kwon","year":"2014","journal-title":"J Bone Joint Surg Am"},{"issue":"2","key":"R49-20230714","doi-asserted-by":"crossref","first-page":"106","DOI":"10.5435\/JAAOS-D-14-00290","article-title":"Metal hypersensitivity and total knee arthroplasty","volume":"24","author":"Lachiewicz","year":"2016","journal-title":"J Am Acad Orthop Surg"}],"container-title":["Journal of the American Academy of Orthopaedic Surgeons"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/00124635-201710000-00004","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T14:48:07Z","timestamp":1787669287000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/00124635-201710000-00004"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,10]]},"references-count":44,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.5435\/jaaos-d-16-00007","relation":{},"ISSN":["1067-151X","1940-5480"],"issn-type":[{"value":"1067-151X","type":"print"},{"value":"1940-5480","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,10]]}}}