{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T15:22:29Z","timestamp":1787671349857,"version":"build-2736575974"},"reference-count":51,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"18","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Am Acad Orthop Surg","JAAOS"],"published-print":{"date-parts":[[2018,9,15]]},"abstract":"<jats:p>Most closed humeral shaft fractures can be successfully managed nonsurgically. However, fractures for which closed treatment is unsuccessful are stabilized using either plates or intramedullary nails. There are shortcomings associated with each technique, including the potential complications of nonunion, infection, shoulder pain, and radial nerve injury. Minimally invasive plate osteosynthesis (MIPO), an innovative alternative treatment, is gaining in popularity. This technique is based on the anterior humeral shaft providing a relatively safe surface for plate application, and limited open exposures proximally and distally allow percutaneous insertion of the necessary implant. More than 40 articles have been published regarding MIPO, and it compares favorably to other available forms of treatment with excellent functional outcomes and a lower rate of iatrogenic radial nerve injury. Larger randomized controlled trials comparing this method with other accepted techniques, including nonsurgical management, are necessary to better define the role of MIPO in the management of humeral shaft fractures.<\/jats:p>","DOI":"10.5435\/jaaos-d-17-00238","type":"journal-article","created":{"date-parts":[[2018,8,15]],"date-time":"2018-08-15T23:05:03Z","timestamp":1534374303000},"page":"652-661","source":"Crossref","is-referenced-by-count":39,"title":["Minimally Invasive Plate Osteosynthesis of Humeral Shaft Fractures: Current State of the Art"],"prefix":"10.5435","volume":"26","author":[{"given":"Kevin","family":"Tetsworth","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Erik","family":"Hohmann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vaida","family":"Glatt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230714","doi-asserted-by":"crossref","first-page":"423","DOI":"10.5435\/JAAOS-20-07-423","article-title":"Management of humeral shaft fractures","volume":"20","author":"Carroll","year":"2012","journal-title":"J Am Acad Orthop Surg"},{"key":"R2-20230714","doi-asserted-by":"crossref","first-page":"478","DOI":"10.2106\/00004623-200004000-00003","article-title":"Functional bracing for the treatment of fractures of the humeral diaphysis","volume":"82","author":"Sarmiento","year":"2000","journal-title":"J Bone Joint Surg Am"},{"key":"R3-20230714","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1080\/17453670610046037","article-title":"Compression plating versus intramedullary nailing of humeral shaft fractures: A meta-analysis","volume":"77","author":"Bhandari","year":"2006","journal-title":"Acta Orthop"},{"key":"R4-20230714","doi-asserted-by":"crossref","first-page":"e307","DOI":"10.1016\/j.jse.2015.07.012","article-title":"Factors associated with radial nerve palsy after operative treatment of diaphyseal humeral shaft fractures","volume":"24","author":"Claessen","year":"2015","journal-title":"J Shoulder Elbow Surg"},{"key":"R5-20230714","doi-asserted-by":"crossref","first-page":"1647","DOI":"10.1302\/0301-620X.87B12.16132","article-title":"Radial nerve palsy associated with fractures of the shaft of the humerus: A systematic review","volume":"87","author":"Shao","year":"2005","journal-title":"J Bone Joint Surg Br"},{"key":"R6-20230714","doi-asserted-by":"crossref","first-page":"336","DOI":"10.1302\/0301-620X.82B3.0820336","article-title":"Fixation of fractures of the shaft of the humerus by dynamic compression plate or intramedullary nail: A prospective, randomised trial","volume":"82","author":"McCormack","year":"2000","journal-title":"J Bone Joint Surg Br"},{"key":"R7-20230714","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1097\/00005131-200003000-00002","article-title":"Randomized prospective study of humeral shaft fracture fixation: Intramedullary nails versus plates","volume":"14","author":"Chapman","year":"2000","journal-title":"J Orthop Trauma"},{"key":"R8-20230714","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1016\/j.jse.2012.06.007","article-title":"Plate versus intramedullary nail fixation in the treatment of humeral shaft fractures: An updated meta-analysis","volume":"22","author":"Ouyang","year":"2013","journal-title":"J Shoulder Elbow Surg"},{"key":"R9-20230714","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1007\/s00590-011-0827-5","article-title":"Treatment of middle third humeral shaft fractures: Minimal invasive plate osteosynthesis versus expandable nailing","volume":"22","author":"An","year":"2012","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"R10-20230714","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1007\/s00264-009-0753-x","article-title":"Plating osteosynthesis of mid-distal humeral shaft fractures: Minimally invasive versus conventional open reduction technique","volume":"34","author":"An","year":"2010","journal-title":"Int Orthop"},{"key":"R11-20230714","doi-asserted-by":"crossref","first-page":"530","DOI":"10.1016\/j.injury.2004.05.036","article-title":"Minimally invasive plate osteosynthesis (MIPO) of the humeral shaft fracture: Is it possible? A cadaveric study and preliminary report","volume":"36","author":"Apivatthakakul","year":"2005","journal-title":"Injury"},{"key":"R12-20230714","doi-asserted-by":"crossref","first-page":"602","DOI":"10.1007\/s00064-009-2008-9","article-title":"Less invasive plate osteosynthesis in humeral shaft fractures","volume":"21","author":"Apivatthakakul","year":"2009","journal-title":"Oper Orthop Traumatol"},{"key":"R13-20230714","doi-asserted-by":"crossref","first-page":"1297","DOI":"10.1007\/s00264-009-0893-z","article-title":"Minimally invasive plate osteosynthesis for humeral shaft fractures: Are results reproducible?","volume":"34","author":"Concha","year":"2010","journal-title":"Int Orthop"},{"key":"R14-20230714","doi-asserted-by":"crossref","first-page":"612","DOI":"10.1097\/BOT.0000000000000643","article-title":"Case-match controlled comparison of minimally invasive plate osteosynthesis and intramedullary nailing for the stabilization of humeral shaft fractures","volume":"30","author":"Davies","year":"2016","journal-title":"J Orthop Trauma"},{"key":"R15-20230714","first-page":"22","article-title":"Minimally invasive percutaneous plate osteosynthesis by anterior approach for fracture shaft of humerus","volume":"2","author":"Deepak","year":"2016","journal-title":"Int J Orthop Sci"},{"key":"R16-20230714","doi-asserted-by":"crossref","first-page":"543","DOI":"10.1007\/s00264-008-0522-2","article-title":"Minimally invasive percutaneous plate osteosynthesis (MIPPO) technique applied in the treatment of humeral shaft distal fractures through a lateral approach","volume":"33","author":"Ji","year":"2009","journal-title":"Int Orthop"},{"key":"R17-20230714","doi-asserted-by":"crossref","first-page":"531","DOI":"10.1007\/s00402-007-0313-z","article-title":"Minimally invasive plating for complex humeral shaft fractures","volume":"127","author":"Jiang","year":"2007","journal-title":"Arch Orthop Trauma Surg"},{"key":"R18-20230714","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1097\/BOT.0b013e3181c2fe49","article-title":"Early full range of shoulder and elbow motion is possible after minimally invasive plate osteosynthesis for humeral shaft fractures","volume":"24","author":"Kobayashi","year":"2010","journal-title":"J Orthop Trauma"},{"key":"R19-20230714","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1007\/s00402-013-1708-7","article-title":"Minimally invasive plate osteosynthesis for humeral shaft fracture: A reproducible technique with the assistance of an external fixator","volume":"133","author":"Lee","year":"2013","journal-title":"Arch Orthop Trauma Surg"},{"key":"R20-20230714","doi-asserted-by":"crossref","first-page":"587","DOI":"10.1016\/j.injury.2003.12.003","article-title":"Bridging plate osteosynthesis of humeral shaft fractures","volume":"35","author":"Livani","year":"2004","journal-title":"Injury"},{"key":"R21-20230714","doi-asserted-by":"crossref","first-page":"1625","DOI":"10.1302\/0301-620X.88B12.17924","article-title":"Fractures of the distal third of the humerus with palsy of the radial nerve: Management using minimally-invasive percutaneous plate osteosynthesis","volume":"88","author":"Livani","year":"2006","journal-title":"J Bone Joint Surg Br"},{"key":"R22-20230714","doi-asserted-by":"crossref","first-page":"358","DOI":"10.4055\/cios.2016.8.4.358","article-title":"Is anterior bridge plating for mid-shaft humeral fractures a suitable option for patients predominantly involved in overhead activities? A functional outcome study in athletes and manual laborers","volume":"8","author":"Mahajan","year":"2016","journal-title":"Clin Orthop Surg"},{"key":"R23-20230714","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1177\/230949901202000305","article-title":"Minimally invasive plate osteosynthesis using a locking compression plate for diaphyseal humeral fractures","volume":"20","author":"Malhan","year":"2012","journal-title":"J Orthop Surg (Hong Kong)"},{"key":"R24-20230714","first-page":"239","article-title":"Minimally invasive surgery in diaphyseal humeral fractures with helicoidal plate: One year result in seven patients [Spanish]","volume":"21","author":"Numbela","year":"2007","journal-title":"Acta Ortop Mex"},{"key":"R25-20230714","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1016\/j.otsr.2011.09.016","article-title":"Plating of humeral shaft fractures: Comparison of standard conventional plating versus minimally invasive plating","volume":"98","author":"Oh","year":"2012","journal-title":"Orthop Traumatol Surg Res"},{"key":"R26-20230714","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1159\/000095487","article-title":"Percutaneous fixation of comminuted fractures of the humerus: Initial experience at Al Razi hospital, Kuwait","volume":"15","author":"Pospula","year":"2006","journal-title":"Med Princ Pract"},{"key":"R27-20230714","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1007\/s00068-008-8047-3","article-title":"Minimally invasive anterior plate osteosynthesis in humeral shaft fractures","volume":"35","author":"Schwarz","year":"2009","journal-title":"Eur J Trauma Emerg Surg"},{"key":"R28-20230714","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1007\/s00590-012-1039-3","article-title":"Internal fixation of humeral shaft fractures using minimally invasive plating: Comparative study of two implants","volume":"23","author":"Shen","year":"2013","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"R29-20230714","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1097\/BOT.0b013e318254895f","article-title":"Minimally invasive plate osteosynthesis of humeral shaft fractures: A technique to aid fracture reduction and minimize complications","volume":"26","author":"Shin","year":"2012","journal-title":"J Orthop Trauma"},{"key":"R30-20230714","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1007\/s00590-009-0551-6","article-title":"Minimally invasive plating osteosynthesis technique applied to humeral shaft fractures: The lateral approach","volume":"20","author":"Spagnolo","year":"2010","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"R31-20230714","doi-asserted-by":"crossref","first-page":"628","DOI":"10.1097\/BOT.0b013e31815928c2","article-title":"Minimally invasive plating osteosynthesis (MIPO) of middle and distal third humeral shaft fractures","volume":"21","author":"Zhiquan","year":"2007","journal-title":"J Orthop Trauma"},{"key":"R32-20230714","doi-asserted-by":"crossref","first-page":"1047","DOI":"10.1016\/j.injury.2010.04.021","article-title":"Sub-muscular plating of the humerus: An emerging technique","volume":"41","author":"Ziran","year":"2010","journal-title":"Injury"},{"key":"R33-20230714","doi-asserted-by":"crossref","first-page":"1741","DOI":"10.1016\/j.jse.2015.07.032","article-title":"Is minimally invasive plating osteosynthesis for humeral shaft fracture advantageous compared with the conventional open technique?","volume":"24","author":"Wang","year":"2015","journal-title":"J Shoulder Elbow Surg"},{"key":"R34-20230714","doi-asserted-by":"crossref","first-page":"767","DOI":"10.1016\/j.jse.2014.02.010","article-title":"Shoulder function after surgical treatment of displaced fractures of the humeral shaft: A randomized trial comparing antegrade intramedullary nailing with minimally invasive plate osteosynthesis","volume":"23","author":"Benegas","year":"2014","journal-title":"J Shoulder Elbow Surg"},{"key":"R35-20230714","doi-asserted-by":"crossref","first-page":"e26271","DOI":"10.5812\/traumamon.26271v2","article-title":"Treatment of humeral shaft fractures: Minimally invasive plate osteosynthesis versus open reduction and internal fixation","volume":"20","author":"Esmailiejah","year":"2015","journal-title":"Trauma Mon"},{"key":"R36-20230714","doi-asserted-by":"crossref","first-page":"154","DOI":"10.4103\/1110-2098.155974","article-title":"Minimally invasive plate osteosynthesis versus open reduction and plate fixation of humeral shaft fractures","volume":"28","author":"Hadhoud","year":"2015","journal-title":"Menoufia Med J"},{"key":"R37-20230714","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1097\/BOT.0000000000000232","article-title":"A prospective randomized study of operative treatment for noncomminuted humeral shaft fractures: Conventional open plating versus minimal invasive plate osteosynthesis","volume":"29","author":"Kim","year":"2015","journal-title":"J Orthop Trauma"},{"key":"R38-20230714","doi-asserted-by":"crossref","first-page":"e1025","DOI":"10.3928\/01477447-20130724-18","article-title":"Minimally invasive plating osteosynthesis for mid-distal third humeral shaft fractures","volume":"36","author":"Lian","year":"2013","journal-title":"Orthopedics"},{"key":"R39-20230714","doi-asserted-by":"crossref","first-page":"583","DOI":"10.2106\/JBJS.16.00628","article-title":"Minimally invasive osteosynthesis with a bridge plate versus a functional brace for humeral shaft fractures: A randomized controlled trial","volume":"99","author":"Matsunaga","year":"2017","journal-title":"J Bone Joint Surg Am"},{"key":"R40-20230714","doi-asserted-by":"crossref","first-page":"1634","DOI":"10.1016\/j.jse.2016.05.014","article-title":"Minimally invasive plating versus either open reduction and plate fixation or intramedullary nailing of humeral shaft fractures: A systematic review and meta-analysis of randomized controlled trials","volume":"25","author":"Hohmann","year":"2016","journal-title":"J Shoulder Elbow Surg"},{"key":"R41-20230714","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1186\/s13018-016-0394-x","article-title":"Minimally invasive plate osteosynthesis vs conventional fixation techniques for surgically treated humeral shaft fractures: A meta-analysis","volume":"11","author":"Hu","year":"2016","journal-title":"J Orthop Surg Res"},{"key":"R42-20230714","doi-asserted-by":"crossref","first-page":"e5464","DOI":"10.1097\/MD.0000000000005464","article-title":"A Bayesian network meta-analysis of three different surgical procedures for the treatment of humeral shaft fractures","volume":"95","author":"Qiu","year":"2016","journal-title":"Medicine (Baltimore)"},{"key":"R43-20230714","doi-asserted-by":"crossref","first-page":"e4955","DOI":"10.1097\/MD.0000000000004955","article-title":"Comparison of minimally invasive plate osteosynthesis and conventional plate osteosynthesis for humeral shaft fracture: A meta-analysis","volume":"95","author":"Yu","year":"2016","journal-title":"Medicine (Baltimore)"},{"issue":"suppl 1","key":"R44-20230714","doi-asserted-by":"crossref","first-page":"A7","DOI":"10.1016\/S0020-1383(97)90110-8","article-title":"Minimally invasive plate osteosynthesis and vascularity: Preliminary results of a cadaver injection study","volume":"28","author":"Farouk","year":"1997","journal-title":"Injury"},{"issue":"suppl 2","key":"R45-20230714","doi-asserted-by":"crossref","first-page":"B11","DOI":"10.1016\/j.injury.2003.09.021","article-title":"Biomechanical testing of the LCP: How can stability in locked internal fixators be controlled?","volume":"34","author":"Stoffel","year":"2003","journal-title":"Injury"},{"key":"R46-20230714","doi-asserted-by":"crossref","first-page":"370","DOI":"10.1186\/s12891-016-1224-3","article-title":"Effects of different surgical techniques on mid-distal humeral shaft vascularity: Open reduction and internal fixation versus minimally invasive plate osteosynthesis","volume":"17","author":"Xue","year":"2016","journal-title":"BMC Musculoskelet Disord"},{"key":"R47-20230714","doi-asserted-by":"crossref","first-page":"1719","DOI":"10.1007\/s00264-008-0616-x","article-title":"Is MIPO in humeral shaft fractures really safe? Postoperative ultrasonographic evaluation","volume":"33","author":"Livani","year":"2009","journal-title":"Int Orthop"},{"issue":"suppl 1","key":"R48-20230714","first-page":"SA29","article-title":"The principle of helical implants: Unusual ideas worth considering. Case studies","volume":"33","author":"Fern\u00e1ndez Dell'Oca","year":"2002","journal-title":"Injury"},{"key":"R49-20230714","doi-asserted-by":"crossref","first-page":"294","DOI":"10.1097\/BOT.0b013e3181f98421","article-title":"Treatment of diaphyseal humeral fractures with the minimally invasive percutaneous plate (MIPPO) technique: A cadaveric study and clinical results","volume":"25","author":"L\u00f3pez-Ar\u00e9valo","year":"2011","journal-title":"J Orthop Trauma"},{"key":"R50-20230714","doi-asserted-by":"crossref","first-page":"520","DOI":"10.4103\/0019-5413.87123","article-title":"Minimally invasive plate osteosynthesis for humerus diaphyseal fractures","volume":"45","author":"Shetty","year":"2011","journal-title":"Indian J Orthop"},{"key":"R51-20230714","doi-asserted-by":"crossref","first-page":"406","DOI":"10.3944\/AOTT.2014.13.0009","article-title":"Functional outcomes of minimal invasive percutaneous plate osteosynthesis (MIPPO) in humerus shaft fractures: A clinical study","volume":"48","author":"Huri","year":"2014","journal-title":"Acta Orthop Traumatol Turc"}],"container-title":["Journal of the American Academy of Orthopaedic Surgeons"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/00124635-201809150-00004","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T14:43:13Z","timestamp":1787668993000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/00124635-201809150-00004"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,9,15]]},"references-count":51,"journal-issue":{"issue":"18","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.5435\/jaaos-d-17-00238","relation":{},"ISSN":["1067-151X","1940-5480"],"issn-type":[{"value":"1067-151X","type":"print"},{"value":"1940-5480","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,9,15]]}}}