{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T15:29:34Z","timestamp":1787671774066,"version":"build-2736575974"},"reference-count":29,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"18","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Am Acad Orthop Surg","JAAOS"],"published-print":{"date-parts":[[2019,9,15]]},"abstract":"<jats:sec>\n                    <jats:title>Introduction:<\/jats:title>\n                    <jats:p>Intramedullary devices are being used more frequently to treat intertrochanteric (IT) femur fractures but without clear benefit in several clinical trials. This study determines differences in complication rates in patients with IT fractures treated with intramedullary versus extramedullary devices.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Using the National Surgical Quality Improvement Program database, patients aged \u226555 years with an isolated IT fracture and an American Society of Anesthesiologists score of &lt;5 were identified. Thirty-day mortality and perioperative complications were assessed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Extramedullary fixation was performed in 4,392 patients, whereas 8,884 underwent intramedullary fixation. Intramedullary fixation was associated with increased 30-day mortality (odds ratio [OR], 1.18;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.038), ventilator use (OR, 1.57;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.004), transfusion (OR, 1.12;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001), and deep vein thrombosis (DVT) (OR, 1.45;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.032). Mean postoperative hospital stay was 1 day shorter for the intramedullary group (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001). After multivariate analysis, ventilator use (OR, 1.59), DVT (OR, 1.44), and transfusion (OR, 1.15) were more common with intramedullary fixation group.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Discussion:<\/jats:title>\n                    <jats:p>Intramedullary fixation for IT fractures was associated with an increased risk of pulmonary complications, DVT, and transfusion. Further randomized controlled studies are required to determine the relative safety of intramedullary versus extramedullary implants.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Level of Evidence:<\/jats:title>\n                    <jats:p>Level III, therapeutic, retrospective comparative study<\/jats:p>\n                  <\/jats:sec>","DOI":"10.5435\/jaaos-d-17-00921","type":"journal-article","created":{"date-parts":[[2019,2,1]],"date-time":"2019-02-01T18:46:44Z","timestamp":1549046804000},"page":"690-695","source":"Crossref","is-referenced-by-count":2,"title":["Increased Pulmonary Complications Associated with Intramedullary Fixation of Intertrochanteric Fractures: An Analysis of 13,276 Hips"],"prefix":"10.5435","volume":"27","author":[{"given":"Nathanael","family":"Heckmann","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J. Ryan","family":"Hill","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Venus","family":"Vakhshori","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Braden","family":"McKnight","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amir","family":"Mostofi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jason","family":"Davis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"George \u201cRick\u201d","family":"Hatch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Geoffrey","family":"Marecek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230714","doi-asserted-by":"crossref","first-page":"S2","DOI":"10.1097\/00005131-200309001-00002","article-title":"Mortality risk after hip fracture","volume":"17","author":"Richmond","year":"2003","journal-title":"J Orthop Trauma"},{"key":"R3-20230714","doi-asserted-by":"crossref","first-page":"1573","DOI":"10.1001\/jama.2009.1462","article-title":"Incidence and mortality of hip fractures in the United States","volume":"302","author":"Brauer","year":"2009","journal-title":"JAMA"},{"key":"R4-20230714","doi-asserted-by":"crossref","first-page":"700","DOI":"10.2106\/JBJS.G.00517","article-title":"Nail or plate fixation of intertrochanteric hip fractures: Changing pattern of practice: A review of the American board of orthopaedic surgery database","volume":"90","author":"Anglen","year":"2008","journal-title":"J Bone Joint Surg Am"},{"key":"R5-20230714","doi-asserted-by":"crossref","first-page":"604","DOI":"10.1097\/BCO.0000000000000424","article-title":"Cephalomedullary nail versus sliding hip screw for fixation of AO 31 A1\/2 intertrochanteric femoral fracture: A 12-year comparison of failure, complications, and mortality","volume":"27","author":"Whale","year":"2016","journal-title":"Curr Orthop Pract"},{"key":"R6-20230714","doi-asserted-by":"crossref","first-page":"792","DOI":"10.2106\/JBJS.I.00508","article-title":"A comparison of the long gamma nail with the sliding hip screw for the treatment of AO\/OTA 31-A2 fractures of the proximal part of the femur: A prospective randomized trial","volume":"92","author":"Barton","year":"2010","journal-title":"J Bone Joint Surg Am"},{"key":"R7-20230714","doi-asserted-by":"crossref","first-page":"1905","DOI":"10.2106\/JBJS.N.01007","article-title":"Intramedullary versus extramedullary fixation for unstable intertrochanteric fractures: A prospective randomized controlled trial","volume":"97","author":"Reindl","year":"2015","journal-title":"J Bone Joint Surg Am"},{"key":"R8-20230714","doi-asserted-by":"crossref","first-page":"1612","DOI":"10.2106\/JBJS.M.00603","article-title":"Cost-effectiveness analysis of fixation options for intertrochanteric hip fractures","volume":"96","author":"Swart","year":"2014","journal-title":"J Bone Joint Surg Am"},{"key":"R9-20230714","doi-asserted-by":"crossref","first-page":"642","DOI":"10.1097\/BOT.0000000000000689","article-title":"Femoral medialization, fixation failures, and functional outcome in trochanteric hip fractures treated with either a sliding hip screw or an intramedullary nail from within a randomized trial","volume":"30","author":"Bretherton","year":"2016","journal-title":"J Orthop Trauma"},{"key":"R10-20230714","doi-asserted-by":"crossref","first-page":"1871","DOI":"10.2106\/JBJS.N.00041","article-title":"Extramedullary compared with intramedullary implants for intertrochanteric hip fractures: Thirty-day outcomes of 4432 procedures from the ACS NSQIP database","volume":"96","author":"Bohl","year":"2014","journal-title":"J Bone Joint Surg Am"},{"key":"R11-20230714","doi-asserted-by":"crossref","first-page":"1629","DOI":"10.1016\/j.jvs.2011.05.116","article-title":"Impact of operative indication and surgical complexity on outcomes after thoracic endovascular aortic repair at National Surgical Quality Improvement Program Centers","volume":"54","author":"Ehlert","year":"2011","journal-title":"J Vasc Surg"},{"key":"R12-20230714","first-page":"CD000093","article-title":"Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults","author":"Parker","year":"2010","journal-title":"Cochrane Database Syst Rev"},{"key":"R13-20230714","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1016\/j.injury.2009.09.012","article-title":"Systematic effects of surgical treatment of hip fractures: Gliding screw-plating vs intramedullary nailing","volume":"41","author":"Verettas","year":"2010","journal-title":"Injury"},{"key":"R14-20230714","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1007\/s00264-013-2196-7","article-title":"Prospective randomised controlled trial of an intramedullary nail versus a sliding hip screw for intertrochanteric fractures of the femur","volume":"38","author":"Aktselis","year":"2014","journal-title":"Int Orthop"},{"key":"R15-20230714","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1097\/BOT.0000000000000713","article-title":"A multicenter randomized control trial comparing a novel intramedullary device (InterTAN) versus conventional treatment (sliding hip screw) of geriatric hip fractures","volume":"31","author":"Sanders","year":"2017","journal-title":"J Orthop Trauma"},{"key":"R16-20230714","doi-asserted-by":"crossref","first-page":"200","DOI":"10.2106\/JBJS.K.01497","article-title":"TRIGEN INTERTAN intramedullary nail versus sliding hip screw: A prospective, randomized multicenter study on pain, function, and complications in 684 patients with an intertrochanteric or subtrochanteric fracture and one year of follow-up","volume":"95","author":"Matre","year":"2013","journal-title":"J Bone Joint Surg Am"},{"key":"R17-20230714","doi-asserted-by":"crossref","first-page":"460","DOI":"10.1097\/BOT.0b013e318162f67f","article-title":"Gamma nails revisited: Gamma nails versus compression hip screws in the management of intertrochanteric fractures of the hip: A meta-analysis","volume":"23","author":"Bhandari","year":"2009","journal-title":"J Orthop Trauma"},{"key":"R18-20230714","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1302\/0301-620X.94B3.28406","article-title":"Sliding hip screw versus the targon PF nail in the treatment of trochanteric fractures of the hip: A randomised trial of 600 fractures","volume":"94","author":"Parker","year":"2012","journal-title":"J Bone Joint Surg Br"},{"key":"R19-20230714","doi-asserted-by":"crossref","first-page":"618","DOI":"10.2106\/00004623-199805000-00002","article-title":"Use of an intramedullary hip-screw compared with a compression hip-screw with a plate for intertrochanteric femoral fractures. A prospective, randomized study of one hundred patients","volume":"80","author":"Hardy","year":"1998","journal-title":"J Bone Joint Surg Am"},{"key":"R20-20230714","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1097\/01.bot.0000151819.95075.ad","article-title":"Trochanteric gamma nail and compression hip screw for trochanteric fractures: A randomized, prospective, comparative study in 210 elderly patients with a new design of the gamma nail","volume":"19","author":"Utrilla","year":"2005","journal-title":"J Orthop Trauma"},{"key":"R21-20230714","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1302\/0301-620X.87B1.15249","article-title":"Pertrochanteric femoral fractures treated with a dynamic hip screw or a proximal femoral nail. A randomised study comparing post-operative rehabilitation","volume":"87","author":"Pajarinen","year":"2005","journal-title":"J Bone Joint Surg Br"},{"key":"R22-20230714","doi-asserted-by":"crossref","first-page":"1293","DOI":"10.1007\/BF03012779","article-title":"Relationship of fat embolism to haemodynamic and echocardiographic changes during cemented arthroplasty","volume":"44","author":"Murphy","year":"1997","journal-title":"Can J Anaesth J Can Anesth"},{"key":"R23-20230714","doi-asserted-by":"crossref","first-page":"1416","DOI":"10.1164\/ajrccm.150.5.7952570","article-title":"Transpulmonary systemic fat embolism. Studies in mongrel dogs after cemented arthroplasty","volume":"150","author":"Byrick","year":"1994","journal-title":"Am J Respir Crit Care Med"},{"key":"R24-20230714","doi-asserted-by":"crossref","first-page":"1350","DOI":"10.2106\/00004623-197456070-00003","article-title":"Fat embolism during total hip replacement. A prospective study","volume":"56","author":"Herndon","year":"1974","journal-title":"J Bone Joint Surg Am"},{"key":"R25-20230714","doi-asserted-by":"crossref","first-page":"709","DOI":"10.1097\/00005373-199311000-00010","article-title":"Influences of different methods of intramedullary femoral nailing on lung function in patients with multiple trauma","volume":"35","author":"Pape","year":"1993","journal-title":"J Trauma"},{"key":"R26-20230714","doi-asserted-by":"crossref","first-page":"1244","DOI":"10.1016\/j.spinee.2013.06.022","article-title":"Complications of rhBMP-2 utilization for posterolateral lumbar fusions requiring reoperation: A single practice, retrospective case series report","volume":"13","author":"Hoffmann","year":"2013","journal-title":"Spine J"},{"key":"R27-20230714","doi-asserted-by":"crossref","first-page":"574","DOI":"10.1097\/00005373-199210000-00014","article-title":"Pulmonary damage after intramedullary femoral nailing in traumatized sheep: Is there an effect from different nailing methods?","volume":"33","author":"Pape","year":"1992","journal-title":"J Trauma"},{"key":"R28-20230714","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1097\/00005373-199402000-00010","article-title":"Intramedullary pressure changes and fat intravasation during intramedullary nailing: An experimental study in sheep","volume":"36","author":"Wozasek","year":"1994","journal-title":"J Trauma"},{"key":"R29-20230714","doi-asserted-by":"crossref","first-page":"980","DOI":"10.1097\/00005373-199606000-00020","article-title":"Nailing versus plating in thoracic trauma: An experimental study in sheep","volume":"40","author":"Neudeck","year":"1996","journal-title":"J Trauma"},{"key":"R30-20230714","doi-asserted-by":"crossref","first-page":"1519","DOI":"10.1016\/S0140-6736(17)30066-1","article-title":"Fracture fixation in the operative management of hip fractures (FAITH): An international, multicentre, randomised controlled trial","volume":"389","year":"2017","journal-title":"Lancet"}],"container-title":["Journal of the American Academy of Orthopaedic Surgeons"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-17-00921","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T14:49:06Z","timestamp":1787669346000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-17-00921"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,9,15]]},"references-count":29,"journal-issue":{"issue":"18","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.5435\/jaaos-d-17-00921","relation":{},"ISSN":["1067-151X","1940-5480"],"issn-type":[{"value":"1067-151X","type":"print"},{"value":"1940-5480","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,9,15]]}}}