{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,3]],"date-time":"2026-10-03T03:12:58Z","timestamp":1790997178420,"version":"4.1.0"},"reference-count":32,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"9","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Am Acad Orthop Surg","JAAOS"],"published-print":{"date-parts":[[2020,5,1]]},"abstract":"<jats:p>Proximal humeral fractures are a commonly encountered injury; however, no consensus has been reached for the ideal treatment. Current surgical fixation options include plate, plate with fibular strut allograft, intramedullary fixation, pinning, suture constructs, and external fixation. Each of these options possesses distinct advantages and disadvantages. With the evolution of implant design, a greater understanding of the mechanisms of failure of fixation, and the ability to preserve fracture biology, the management of proximal humeral fractures with intramedullary fixation has become an accepted treatment option. From a biomechanical perspective, intramedullary fixation may have advantages over laterally based fixation, in particular with fractures associated with significant calcar comminution. The ability to insert the implant from a superior starting point may help preserve vascular supply to the humeral head and tuberosities. With reported outcomes comparable with the aforementioned techniques and an evolving understanding of fracture characteristics and failures of fixation, intramedullary fixation represents an alternative treatment option for proximal humeral fractures with specific fixation and biologic advantages.<\/jats:p>","DOI":"10.5435\/jaaos-d-18-00360","type":"journal-article","created":{"date-parts":[[2019,12,19]],"date-time":"2019-12-19T12:32:53Z","timestamp":1576758773000},"page":"e374-e383","source":"Crossref","is-referenced-by-count":16,"title":["Intramedullary Fixation for Proximal Humeral Fractures"],"prefix":"10.5435","volume":"28","author":[{"given":"Benjamin W.","family":"Sears","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Armodios M.","family":"Hatzidakis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter S.","family":"Johnston","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2020,12,17]]},"reference":[{"key":"R1-20230714","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1097\/01.blo.0000194672.79634.78","article-title":"Update in the epidemiology of proximal humeral fractures","volume":"442","author":"Palvanen","year":"2006","journal-title":"Clin Orthop Relat Res"},{"key":"R2-20230714","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1002\/acr.21563","article-title":"Epidemiology of humerus fractures in the United States: Nationwide emergency department sample, 2008","volume":"64","author":"Kim","year":"2012","journal-title":"Arthritis Care Res (Hoboken)"},{"key":"R3-20230714","doi-asserted-by":"crossref","first-page":"e641","DOI":"10.3928\/01477447-20170411-03","article-title":"Trends in surgical management and costs for operative treatment of proximal humerus fractures in the elderly","volume":"40","author":"Hasty","year":"2017","journal-title":"Orthopedics"},{"key":"R4-20230714","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1186\/s13018-017-0639-3","article-title":"Current concepts in locking plate fixation of proximal humerus fractures","volume":"12","author":"Laux","year":"2017","journal-title":"J Orthop Surg Res"},{"key":"R5-20230714","doi-asserted-by":"crossref","first-page":"1486","DOI":"10.2106\/00004623-199072100-00009","article-title":"The arterial vascularization of the humeral head. An anatomical study","volume":"72","author":"Gerber","year":"1990","journal-title":"J Bone Joint Surg Am"},{"key":"R6-20230714","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1097\/BOT.0000000000000252","article-title":"Factors that influence reduction loss in proximal humerus fracture surgery","volume":"29","author":"Jung","year":"2015","journal-title":"J Orthop Trauma"},{"key":"R7-20230714","doi-asserted-by":"crossref","first-page":"1283","DOI":"10.1016\/j.injury.2011.01.017","article-title":"Predicting failure after surgical fixation of proximal humerus fractures","volume":"42","author":"Krappinger","year":"2011","journal-title":"Injury"},{"key":"R8-20230714","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1016\/j.jse.2013.08.023","article-title":"Proximal humerus nailing: A randomized clinical trial between curvilinear and straight nails","volume":"23","author":"Lopiz","year":"2014","journal-title":"J Shoulder Elbow Surg"},{"key":"R9-20230714","doi-asserted-by":"crossref","first-page":"1241","DOI":"10.1016\/j.jse.2010.12.010","article-title":"Surgical treatment of displaced proximal humerus fractures with a short intramedullary nail","volume":"20","author":"Nolan","year":"2011","journal-title":"J Shoulder Elbow Surg"},{"key":"R10-20230714","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1186\/1754-9493-8-18","article-title":"Straight proximal humeral nails are surrounded by more bone stock in comparison to bent nails in an experimental cadaveric study","volume":"8","author":"G\u00fcnther","year":"2014","journal-title":"Patient Saf Surg"},{"key":"R11-20230714","doi-asserted-by":"crossref","first-page":"602","DOI":"10.1097\/01.bot.0000246412.10176.14","article-title":"Vascular implications of minimally invasive plating of proximal humerus fractures","volume":"20","author":"Gardner","year":"2006","journal-title":"J Orthop Trauma"},{"key":"R12-20230714","doi-asserted-by":"crossref","first-page":"1395","DOI":"10.1302\/0301-620X.98B10.38011","article-title":"Anatomy of the terminal branch of the posterior circumflex humeral artery: Relevance to the deltopectoral approach to the shoulder","volume":"98-B","author":"Smith","year":"2016","journal-title":"Bone Joint J"},{"key":"R13-20230714","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1016\/j.injury.2010.11.058","article-title":"A systematic review of locking plate fixation of proximal humerus fractures","volume":"42","author":"Sproul","year":"2011","journal-title":"Injury"},{"key":"R14-20230714","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1007\/s10195-015-0384-5","article-title":"Outcomes of intramedullary nailing for acute proximal humerus fractures: A systematic review","volume":"17","author":"Wong","year":"2016","journal-title":"J Orthop Traumatol"},{"key":"R15-20230714","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/j.clinbiomech.2010.01.009","article-title":"Proximal humerus fracture rotational stability after fixation using a locking plate or a fixed-angle locked nail: The role of implant stiffness","volume":"25","author":"Foruria","year":"2010","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"R16-20230714","first-page":"2258","article-title":"Two-part surgical neck fractures of the proximal part of the humerus. A biomechanical evaluation of two fixation techniques","volume":"88","author":"Edwards","year":"2006","journal-title":"J Bone Joint Surg Am"},{"key":"R17-20230714","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1007\/s00402-002-0465-9","article-title":"Proximal humeral fractures: How stiff should an implant be? A comparative mechanical study with new implants in human specimens","volume":"123","author":"Lill","year":"2003","journal-title":"Arch Orthop Trauma Surg"},{"key":"R18-20230714","doi-asserted-by":"crossref","first-page":"261","DOI":"10.3233\/THC-2006-144-509","article-title":"A comparative biomechanical analysis of implants for the stabilization of proximal humerus fractures","volume":"14","author":"F\u00fcchtmeier","year":"2006","journal-title":"Technol Health Care"},{"key":"R19-20230714","doi-asserted-by":"crossref","first-page":"510","DOI":"10.1016\/j.injury.2013.08.024","article-title":"A comprehensive update on current fixation options for two-part proximal humerus fractures: A biomechanical investigation","volume":"45","author":"Yoon","year":"2014","journal-title":"Injury"},{"key":"R20-20230714","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1016\/j.clinbiomech.2015.12.005","article-title":"Anatomical and biomechanical evaluation of an intramedullary nail for fractures of proximal humerus fractures based on tuberosity fixation","volume":"32","author":"Clavert","year":"2016","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"R21-20230714","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1007\/s00264-015-2950-0","article-title":"Clinical and radiological outcomes of unstable proximal humeral fractures treated with a locking plate and fibular strut allograft","volume":"40","author":"Panchal","year":"2016","journal-title":"Int Orthop"},{"key":"R22-20230714","first-page":"471","article-title":"Technique of open reduction and internal fixation of comminuted proximal humerus fractures with allograft femoral head metaphyseal reconstruction","volume":"44","author":"Parada","year":"2015","journal-title":"Am J Orthop (Belle Mead NJ)"},{"key":"R23-20230714","doi-asserted-by":"crossref","first-page":"219","DOI":"10.3928\/0147-7447-19890201-05","article-title":"Humeral locking nail: A preliminary report","volume":"12","author":"Seidel","year":"1989","journal-title":"Orthopedics"},{"key":"R24-20230714","doi-asserted-by":"crossref","first-page":"2172","DOI":"10.2106\/JBJS.J.00754","article-title":"Angular-stable locked intramedullary nailing of two-part surgical neck fractures of the proximal part of the humerus. A multicenter retrospective observational study","volume":"93","author":"Hatzidakis","year":"2011","journal-title":"J Bone Joint Surg Am"},{"key":"R25-20230714","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1097\/01.ta.0000224148.73016.30","article-title":"Effectiveness of locked nailing for displaced three-part proximal humeral fractures","volume":"61","author":"Lin","year":"2006","journal-title":"J Trauma"},{"key":"R26-20230714","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1007\/s00590-014-1493-1","article-title":"Antegrade nailing evolution for proximal humeral fractures, the telegraph IV (\u00ae): A study of 67 patients","volume":"25","author":"Cuny","year":"2015","journal-title":"Eur J Orthop Surg Traumatol"},{"issue":"suppl 1","key":"R27-20230714","doi-asserted-by":"crossref","first-page":"S29","DOI":"10.1016\/j.injury.2013.10.038","article-title":"Nailing of three- and four-part fractures of the humeral head\u2014Long-term results","volume":"45","author":"Kloub","year":"2014","journal-title":"Injury"},{"key":"R28-20230714","doi-asserted-by":"crossref","first-page":"695","DOI":"10.1016\/j.jse.2016.02.003","article-title":"Locking intramedullary nails compared with locking plates for two- and three-part proximal humeral surgical neck fractures: A randomized controlled trial","volume":"25","author":"Gracitelli","year":"2016","journal-title":"J Shoulder Elbow Surg"},{"key":"R29-20230714","doi-asserted-by":"crossref","first-page":"963","DOI":"10.1016\/j.otsr.2016.09.015","article-title":"Fixation of 4-part fractures of the proximal humerus: Can we identify radiological criteria that support locking plates or IM nailing? Comparative, retrospective study of 107 cases","volume":"102","author":"Gadea","year":"2016","journal-title":"Orthop Traumatol Surg Res"},{"key":"R30-20230714","doi-asserted-by":"crossref","first-page":"917","DOI":"10.1016\/j.otsr.2014.09.021","article-title":"Locking plate fixation versus antegrade nailing of 3- and 4-part proximal humerus fractures in patients without osteoporosis. Comparative retrospective study of 63 cases","volume":"100","author":"Boudard","year":"2014","journal-title":"Orthop Traumatol Surg Res"},{"key":"R31-20230714","doi-asserted-by":"crossref","first-page":"733","DOI":"10.1080\/17434440.2017.1364624","article-title":"Locking intramedullary nails versus locking plates for the treatment of proximal humerus fractures","volume":"14","author":"Gracitelli","year":"2017","journal-title":"Expert Rev Med Devices"},{"key":"R32-20230714","doi-asserted-by":"crossref","first-page":"159","DOI":"10.2106\/JBJS.J.00155","article-title":"Locking intramedullary nails and locking plates in the treatment of two-part proximal humeralsurgical neck fractures: A prospective randomized trial with a minimum of three years of follow-up","volume":"93","author":"Zhu","year":"2011","journal-title":"J Bone Joint Surg Am"}],"container-title":["Journal of the American Academy of Orthopaedic Surgeons"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-18-00360","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T14:39:52Z","timestamp":1787668792000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-18-00360"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,5,1]]},"references-count":32,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.5435\/jaaos-d-18-00360","relation":{},"ISSN":["1067-151X","1940-5480"],"issn-type":[{"value":"1067-151X","type":"print"},{"value":"1940-5480","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,5,1]]}}}