{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,13]],"date-time":"2026-11-13T15:39:45Z","timestamp":1794584385014,"version":"4.9.1"},"reference-count":40,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"19","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Am Acad Orthop Surg","JAAOS"],"published-print":{"date-parts":[[2019,10,1]]},"abstract":"<jats:p>An orthopaedic surgeon's knowledge of anatomical landmarks is crucial, but other modalities supplement this by providing guidance and feedback to a surgeon. Advances in imaging have enabled three-dimensional visualization of the surgical field and patient anatomy, whereas advances in computer technology have allowed for real-time tracking of instruments and implants. Together, these innovations have given rise to intraoperative navigation systems. The authors review these advances in intraoperative navigation across orthopaedic subspecialties, focusing on the most recent evidence on patient outcomes and complications, the associated learning curve, and the effects on operative time, radiation exposure, and cost. In spine surgery, navigated pedicle screw placement may increase accuracy and safety, especially valuable when treating complex deformities. Improved accuracy of pelvic and peri-articular tumor resection and percutaneous fixation of acetabular and femoral neck fractures has also been achieved using navigation. Early applications in arthroscopy have included surface-based registration for tunnel positioning for anterior cruciate ligament reconstruction and osteochondroplasty for femoro-acetabular impingement. Navigated arthroplasty techniques have addressed knee gap balancing and mechanical axis restoration as well as acetabular cup and glenoid baseplate positioning. Among these orthopaedic subspecialties, significant variation is found in the clinical relevance and dedication to research of navigation techniques.<\/jats:p>","DOI":"10.5435\/jaaos-d-18-00478","type":"journal-article","created":{"date-parts":[[2019,2,9]],"date-time":"2019-02-09T00:41:38Z","timestamp":1549672898000},"page":"e849-e858","source":"Crossref","is-referenced-by-count":66,"title":["The Role of Intraoperative Navigation in Orthopaedic Surgery"],"prefix":"10.5435","volume":"27","author":[{"given":"Alexa J.","family":"Karkenny","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joseph R.","family":"Mendelis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David S.","family":"Geller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jaime A.","family":"Gomez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230714","doi-asserted-by":"crossref","first-page":"E12","DOI":"10.3171\/2009.7.FOCUS09118","article-title":"Early history of the stereotactic apparatus in neurosurgery","volume":"27","author":"Rahman","year":"2009","journal-title":"Neurosurg Focus"},{"key":"R2-20230714","doi-asserted-by":"crossref","first-page":"641","DOI":"10.3171\/jns.1995.83.4.0641","article-title":"Application of frameless stereotaxy to pedicle screw fixation of the spine","volume":"83","author":"Kalfas","year":"1995","journal-title":"J Neurosurg"},{"key":"R3-20230714","first-page":"S121","article-title":"An 8- to 10-year follow-up of 26 computer-assisted total knee arthroplasties","volume":"30","author":"Saragaglia","year":"2007","journal-title":"Orthopedics"},{"key":"R4-20230714","doi-asserted-by":"crossref","first-page":"800","DOI":"10.5435\/JAAOS-22-12-800","article-title":"Three-dimensional intraoperative imaging modalities in orthopaedic surgery: A narrative review","volume":"22","author":"Qureshi","year":"2014","journal-title":"J Am Acad Orthop Surg"},{"issue":"suppl 2","key":"R5-20230714","doi-asserted-by":"crossref","first-page":"S131","DOI":"10.1007\/s00586-012-2360-6","article-title":"Improving safety in spinal deformity surgery: Advances in navigation and neurologic monitoring","volume":"22","author":"Flynn","year":"2013","journal-title":"Eur Spine J"},{"key":"R6-20230714","doi-asserted-by":"crossref","first-page":"E473","DOI":"10.1097\/BRS.0b013e318238bbd9","article-title":"Computed tomography-guided navigation of thoracic pedicle screws for adolescent idiopathic scoliosis results in more accurate placement and less screw removal","volume":"37","author":"Ughwanogho","year":"2012","journal-title":"Spine"},{"key":"R7-20230714","doi-asserted-by":"crossref","first-page":"E1580","DOI":"10.1097\/BRS.0b013e318271b1fa","article-title":"A prospective multicenter registry on the accuracy of pedicle screw placement in the thoracic, lumbar, and sacral levels with the use of the O-arm imaging system and StealthStation Navigation","volume":"37","author":"Van de Kelft","year":"2012","journal-title":"Spine"},{"key":"R8-20230714","doi-asserted-by":"crossref","first-page":"1756","DOI":"10.1007\/s00586-016-4930-5","article-title":"Accuracy of pedicle screw insertion in posterior scoliosis surgery: A comparison between intraoperative navigation and preoperative navigation techniques","volume":"26","author":"Zhang","year":"2017","journal-title":"Eur Spine J"},{"key":"R9-20230714","doi-asserted-by":"crossref","first-page":"E14","DOI":"10.3171\/2017.3.FOCUS179","article-title":"Accuracy of robot-guided versus freehand fluoroscopy-assisted pedicle screw insertion in thoracolumbar spinal surgery","volume":"42","author":"Molliqaj","year":"2017","journal-title":"Neurosurg Focus"},{"key":"R10-20230714","doi-asserted-by":"crossref","first-page":"1397","DOI":"10.1097\/BRS.0000000000001026","article-title":"Safety and efficacy of reconstruction of complex cervical spine pathology using pedicle screws inserted with stealth navigation and 3D image-guided (O-arm) technology","volume":"40","author":"Theologis","year":"2015","journal-title":"Spine (Phila Pa 1976)"},{"key":"R11-20230714","doi-asserted-by":"crossref","first-page":"e23","DOI":"10.1097\/BPO.0b013e318263a39e","article-title":"The accuracy of navigation and 3D image-guided placement for the placement of pedicle screws in congenital spine deformity","volume":"32","author":"Larson","year":"2012","journal-title":"J Pediatr Orthop"},{"key":"R12-20230714","doi-asserted-by":"crossref","first-page":"1729","DOI":"10.1007\/s00586-015-4012-0","article-title":"Does intraoperative navigation improve the accuracy of pedicle screw placement in the apical region of dystrophic scoliosis secondary to neurofibromatosis type I: Comparison between O-arm navigation and free-hand technique","volume":"25","author":"Jin","year":"2016","journal-title":"Eur Spine J"},{"key":"R13-20230714","doi-asserted-by":"crossref","first-page":"530","DOI":"10.1097\/BPO.0000000000000493","article-title":"Comparison of effective dose of radiation during pedicle screw placement using intraoperative computed tomography navigation versus fluoroscopy in children with spinal deformities","volume":"36","author":"Dabaghi Richerand","year":"2016","journal-title":"J Pediatr Orthop"},{"key":"R14-20230714","doi-asserted-by":"crossref","first-page":"621","DOI":"10.1097\/BPO.0000000000000504","article-title":"Switching to a pediatric dose O-arm protocol in spine surgery significantly reduced patient radiation exposure","volume":"36","author":"Su","year":"2016","journal-title":"J Pediatr Orthop"},{"key":"R15-20230714","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1097\/BPO.0000000000000608","article-title":"How does patient radiation exposure compare with low-dose O-arm versus fluoroscopy for pedicle screw placement in idiopathic scoliosis?","volume":"37","author":"Su","year":"2017","journal-title":"J Pediatr Orthop"},{"key":"R16-20230714","doi-asserted-by":"crossref","first-page":"2516","DOI":"10.1097\/01.brs.0000238675.91612.2f","article-title":"Radiation exposure during pedicle screw placement in adolescent idiopathic scoliosis: Is fluoroscopy safe?","volume":"31","author":"Ul Haque","year":"2006","journal-title":"Spine"},{"key":"R17-20230714","doi-asserted-by":"crossref","first-page":"E56","DOI":"10.1097\/01.brs.0000252094.64857.ab","article-title":"Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries","volume":"32","author":"Rajasekaran","year":"2007","journal-title":"Spine"},{"key":"R18-20230714","doi-asserted-by":"crossref","first-page":"651","DOI":"10.1007\/s00586-016-4773-0","article-title":"Radiation exposure using the O-arm((R)) surgical imaging system","volume":"26","author":"Pitteloud","year":"2017","journal-title":"Eur Spine J"},{"key":"R19-20230714","doi-asserted-by":"crossref","first-page":"875","DOI":"10.1007\/s00586-010-1683-4","article-title":"Computer tomography assessment of pedicle screw placement in lumbar and sacral spine: Comparison between free-hand and O-arm based navigation techniques","volume":"20","author":"Silbermann","year":"2011","journal-title":"Eur Spine J"},{"key":"R20-20230714","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1016\/j.jocn.2016.02.033","article-title":"Effect of intraoperative navigation on operative time in 1-level lumbar fusion surgery","volume":"32","author":"Khanna","year":"2016","journal-title":"J Clin Neurosci"},{"key":"R21-20230714","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1016\/j.spinee.2015.09.062","article-title":"Economic evaluation comparing intraoperative cone beam CT-based navigation and conventional fluoroscopy for the placement of spinal pedicle screws: A patient-level data cost-effectiveness analysis","volume":"16","author":"Dea","year":"2016","journal-title":"Spine J"},{"key":"R22-20230714","doi-asserted-by":"crossref","first-page":"1067","DOI":"10.1016\/j.arthro.2009.05.016","article-title":"Anterior cruciate ligament reconstruction with and without computer navigation: A clinical and magnetic resonance imaging evaluation 2 years after surgery","volume":"25","author":"Street","year":"2009","journal-title":"Arthroscopy"},{"key":"R23-20230714","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1016\/j.knee.2016.12.007","article-title":"Registration accuracy enhancement of a surgical navigation system for anterior cruciate ligament reconstruction: A phantom and cadaveric study","volume":"24","author":"Kim","year":"2017","journal-title":"Knee"},{"key":"R24-20230714","doi-asserted-by":"crossref","first-page":"e397","DOI":"10.1016\/j.eats.2017.10.013","article-title":"Computer-assisted hip arthroscopic surgery for femoroacetabular impingement","volume":"7","author":"Kobayashi","year":"2018","journal-title":"Arthrosc Tech"},{"key":"R25-20230714","doi-asserted-by":"crossref","first-page":"40","DOI":"10.2106\/JBJS.N.00276","article-title":"Navigated pelvic osteotomy and tumor resection: A study assessing the accuracy and reproducibility of resection planes in sawbones and cadavers","volume":"97","author":"Sternheim","year":"2015","journal-title":"J Bone Joint Surg Am"},{"key":"R26-20230714","doi-asserted-by":"crossref","first-page":"2533","DOI":"10.1007\/s11999-008-0374-5","article-title":"Image fusion for computer-assisted bone tumor surgery","volume":"466","author":"Wong","year":"2008","journal-title":"Clin Orthop Relat Res"},{"key":"R27-20230714","doi-asserted-by":"crossref","first-page":"796","DOI":"10.1007\/s11999-014-3604-z","article-title":"Does intraoperative navigation assistance improve bone tumor resection and allograft reconstruction results?","volume":"473","author":"Aponte-Tineo","year":"2015","journal-title":"Clin orthopaedics Relat Res"},{"key":"R28-20230714","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1016\/j.arth.2017.06.004","article-title":"Comparison of the iAssist handheld guidance system to conventional instruments for mechanical Axis restoration in total knee arthroplasty","volume":"33","author":"Kinney","year":"2018","journal-title":"J Arthroplasty"},{"key":"R29-20230714","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1016\/j.arth.2017.09.005","article-title":"Accelerometer-based and computer-assisted navigation in total knee arthroplasty: A reduction in mechanical Axis outliers does not lead to improvement in functional outcomes or quality of life when compared to conventional total knee arthroplasty","volume":"33","author":"Goh","year":"2017","journal-title":"J Arthroplasty"},{"key":"R30-20230714","doi-asserted-by":"crossref","first-page":"635","DOI":"10.2106\/JBJS.M.01496","article-title":"Computer navigation for total knee arthroplasty reduces revision rate for patients less than sixty-five years of age","volume":"97","author":"de Steiger","year":"2015","journal-title":"J Bone Joint Surg Am"},{"key":"R31-20230714","doi-asserted-by":"crossref","first-page":"627","DOI":"10.2106\/JBJS.15.00664","article-title":"Improved accuracy of component positioning with robotic-assisted unicompartmental knee arthroplasty: Data from a prospective, randomized controlled study","volume":"98","author":"Bell","year":"2016","journal-title":"J Bone Joint Surg Am"},{"key":"R32-20230714","doi-asserted-by":"crossref","first-page":"1076","DOI":"10.1016\/j.arth.2017.11.030","article-title":"Computer-assisted total knee arthroplasty: Is there a difference between image-based and imageless techniques?","volume":"33","author":"Tabatabaee","year":"2017","journal-title":"J Arthroplasty"},{"key":"R33-20230714","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1016\/j.arth.2017.08.001","article-title":"Accuracy of cup positioning with the computed tomography-based two-dimensional to three-dimensional matched navigation system: A prospective, randomized controlled study","volume":"33","author":"Yamada","year":"2018","journal-title":"J Arthroplasty"},{"key":"R34-20230714","doi-asserted-by":"crossref","first-page":"1563","DOI":"10.1016\/j.jse.2014.01.051","article-title":"Accuracy of patient-specific guided glenoid baseplate positioning for reverse shoulder arthroplasty","volume":"23","author":"Levy","year":"2014","journal-title":"J Shoulder Elbow Surg"},{"key":"R35-20230714","doi-asserted-by":"crossref","first-page":"2842","DOI":"10.1016\/j.arth.2017.03.073","article-title":"Pin site complications associated with computer-assisted navigation in hip and knee arthroplasty","volume":"32","author":"Kamara","year":"2017","journal-title":"J Arthroplasty"},{"key":"R36-20230714","doi-asserted-by":"crossref","first-page":"1748","DOI":"10.2106\/JBJS.E.00137","article-title":"Computerized navigation for the internal fixation of femoral neck fractures","volume":"88","author":"Liebergall","year":"2006","journal-title":"J Bone Joint Surg Am"},{"key":"R37-20230714","doi-asserted-by":"crossref","first-page":"1387","DOI":"10.1007\/s00264-017-3659-z","article-title":"Three-dimensional navigation-guided percutaneous screw fixation for nondisplaced and displaced pelvi-acetabular fractures in a major trauma centre","volume":"42","author":"Chui","year":"2017","journal-title":"Int Orthop"},{"key":"R38-20230714","doi-asserted-by":"crossref","first-page":"716","DOI":"10.1097\/BOT.0b013e31828fc4a5","article-title":"CT-3D-fluoroscopy matching navigation can reduce the malposition rate of iliosacral screw insertion for less-experienced surgeons","volume":"27","author":"Takao","year":"2013","journal-title":"J Orthop Trauma"},{"key":"R39-20230714","doi-asserted-by":"crossref","first-page":"613","DOI":"10.1016\/j.jhsa.2013.12.032","article-title":"Computer-assisted navigation for dorsal percutaneous scaphoid screw placement: A cadaveric study","volume":"39","author":"Kam","year":"2014","journal-title":"J Hand Surg Am"},{"key":"R40-20230714","doi-asserted-by":"crossref","first-page":"462","DOI":"10.4055\/cios.2014.6.4.462","article-title":"Robotic and navigation systems in orthopaedic surgery: How much do our patients understand?","volume":"6","author":"Jassim","year":"2014","journal-title":"Clin Orthop Surg"}],"container-title":["Journal of the American Academy of Orthopaedic Surgeons"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-18-00478","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T14:49:07Z","timestamp":1787669347000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-18-00478"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,10,1]]},"references-count":40,"journal-issue":{"issue":"19","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.5435\/jaaos-d-18-00478","relation":{},"ISSN":["1067-151X","1940-5480"],"issn-type":[{"value":"1067-151X","type":"print"},{"value":"1940-5480","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,10,1]]}}}