{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T15:29:53Z","timestamp":1787671793843,"version":"build-2736575974"},"reference-count":35,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Am Acad Orthop Surg","JAAOS"],"published-print":{"date-parts":[[2020,1,15]]},"abstract":"<jats:p>Intramedullary fixation of proximal tibia fractures remains a challenging surgical technique, with malalignment reported as high as 84%. The pull from the extensor mechanism, the hamstring and iliotibial band, in addition to the lack of endosteal fit from the nail, has made surgical fixation of these fractures difficult. Commonly held principles to reduce angular deformity include ensuring adequate imaging, obtaining an optimal start and trajectory for the implant, and obtaining and maintaining a reduction throughout the duration of the procedure. Some adjunctive techniques to assist in the application of these principles include use of a semiextended technique, clamping, blocking screws\/wires, and unicortical plates. Understanding the challenges involved in intramedullary nailing of proximal tibia fractures and considering a wide array of techniques in the orthopaedic surgeon's armamentarium to combat these challenges is important.<\/jats:p>","DOI":"10.5435\/jaaos-d-18-00765","type":"journal-article","created":{"date-parts":[[2019,7,24]],"date-time":"2019-07-24T18:02:30Z","timestamp":1563991350000},"page":"66-73","source":"Crossref","is-referenced-by-count":9,"title":["Pearls and Pitfalls With Intramedullary Nailing of Proximal Tibia Fractures"],"prefix":"10.5435","volume":"28","author":[{"given":"Christopher","family":"Lee","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephen D.","family":"Zoller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paul W.","family":"Perdue","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jason W.","family":"Nascone","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230714","first-page":"64","article-title":"Proximal third tibial shaft fractures: Should they be nailed?","volume":"315","author":"Lang","year":"1995","journal-title":"Clin Orthop Rel Res"},{"key":"R2-20230714","first-page":"1055","article-title":"Proximal one-third tibial fracture solutions","volume":"18","author":"Benirschke","year":"1995","journal-title":"Orthop Trans"},{"key":"R3-20230714","first-page":"65","article-title":"Radiographic analysis of tibial fracture malalignment following intramedullary nailing","volume":"339","author":"Freedman","year":"1997","journal-title":"Clin Orthop Relat Res"},{"key":"R4-20230714","first-page":"334","article-title":"Extra-articular fractures of the proximal tibial diaphysis: Their epidemiology, management and outcome","volume":"42","author":"Tytherleigh-Strong","year":"1997","journal-title":"J R Coll Surg Edinb"},{"key":"R5-20230714","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1097\/00005131-200105000-00005","article-title":"A technique for intramedullary nailing of proximal third tibia fractures","volume":"15","author":"Buehler","year":"2001","journal-title":"J Orthop Trauma"},{"key":"R6-20230714","doi-asserted-by":"crossref","first-page":"690","DOI":"10.5435\/00124635-201111000-00005","article-title":"Intramedullary nailing of extra-articular proximal tibia fractures","volume":"19","author":"Histerman","year":"2011","journal-title":"JAAOS"},{"key":"R7-20230714","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1097\/00005131-200103000-00010","article-title":"Tibial portal placement: The radiographic correlate of the anatomic safe zone","volume":"15","author":"McConnell","year":"2001","journal-title":"J Orthop Trauma"},{"key":"R8-20230714","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1097\/00005131-199905000-00004","article-title":"Intraarticular anatomic risks of tibial nailing","volume":"13","author":"Tornetta","year":"1999","journal-title":"J Orthop Trauma"},{"key":"R9-20230714","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1097\/00003086-199607000-00029","article-title":"Semiextended position of intramedullary nailing of the proximal tibia","volume":"328","author":"Tornetta","year":"1996","journal-title":"Clin Orthop Relat Res"},{"key":"R10-20230714","doi-asserted-by":"crossref","first-page":"536","DOI":"10.1016\/j.injury.2006.01.042","article-title":"Prospective study of the clinico-radiological outcome of interlocked nailing in proximal third tibial shaft fractures","volume":"37","author":"Vidyadhara","year":"2006","journal-title":"Injury"},{"key":"R11-20230714","doi-asserted-by":"crossref","first-page":"172","DOI":"10.3928\/01477447-20100129-22","article-title":"Intramedullary nailing of tibial fractures: Review of surgical techniques and description of a percutaneous lateral suprapatellar approach","volume":"33","author":"Morandi","year":"2010","journal-title":"Orthopedics"},{"key":"R12-20230714","doi-asserted-by":"crossref","first-page":"704","DOI":"10.1097\/BOT.0b013e3181d5d9f4","article-title":"Extra-articular technique for semiextended tibial nailing","volume":"24","author":"Kubiak","year":"2010","journal-title":"J Orthop Trauma"},{"key":"R13-20230714","first-page":"556","article-title":"Percutaneous reduction during intramedullary nailing in comminuted tibial shaft fractures","volume":"31","author":"Kim","year":"2008","journal-title":"Orthopedics"},{"key":"R14-20230714","doi-asserted-by":"crossref","first-page":"963","DOI":"10.1302\/0301-620X.81B6.0810963","article-title":"The use of Poller screws as blocking screws in stabilising tibial fractures treated with small diameter intramedullary nails","volume":"81","author":"Krettek","year":"1999","journal-title":"J Bone Joint Surg Br"},{"key":"R15-20230714","doi-asserted-by":"crossref","first-page":"550","DOI":"10.1097\/00005131-199911000-00006","article-title":"The mechanical effect of blocking screws (\u201cPoller screws\u201d) in stabilizing tibia fractures with short proximal or distal fragments after insertion of small-diameter intramedullary nails","volume":"13","author":"Krettek","year":"1999","journal-title":"J Orthop Trauma"},{"key":"R16-20230714","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1097\/00005131-200105000-00005","article-title":"Fractures of the proximal third of the tibial shaft treated with intramedullary nails and blocking screws","volume":"15","author":"Ricci","year":"2001","journal-title":"J Orthop Trauma"},{"key":"R17-20230714","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1097\/01.bot.0000244993.60374.d6","article-title":"Intramedullary nailing of proximal quarter tibial fractures","volume":"20","author":"Nork","year":"2006","journal-title":"J Orthop Trauma"},{"key":"R18-20230714","doi-asserted-by":"crossref","first-page":"647","DOI":"10.3928\/0147-7447-19970701-14","article-title":"Anterior unicortical buttress plating in conjunction with an unreamed interlocking intramedullary nail for treatment of very proximal tibial diaphyseal fractures","volume":"20","author":"Matthews","year":"1997","journal-title":"Orthopedics"},{"key":"R19-20230714","doi-asserted-by":"crossref","first-page":"189","DOI":"10.3928\/01477447-20070301-10","article-title":"Provisional unicortical plating with reamed intramedullary nailing in segmental tibial fractures involving the high proximal metaphysis","volume":"30","author":"Kim","year":"2007","journal-title":"Orthopedics"},{"key":"R20-20230714","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1097\/00005131-200603000-00007","article-title":"Reduction plating for provisional fracture fixation","volume":"20","author":"Archdeacon","year":"2006","journal-title":"J Orthop Trauma"},{"key":"R21-20230714","doi-asserted-by":"crossref","first-page":"554","DOI":"10.1097\/BOT.0000000000000874","article-title":"Does provisional plating of closed tibia fractures have higher complications rates?","volume":"31","author":"Haller","year":"2017","journal-title":"J Orthop Trauma"},{"key":"R22-20230714","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1097\/BOT.0000000000000777","article-title":"Percutaneous or open reduction of closed tibial shaft fractures during intramedullary nailing does not increase wound complications, infection or nonunion rates","volume":"31","author":"Auston","year":"2017","journal-title":"J Orthop Trauma"},{"key":"R23-20230714","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1097\/00005131-199308000-00003","article-title":"Influences of some design parameters on the biomechanics of the unreamed tibial intramedullary nail","volume":"7","author":"Henley","year":"1993","journal-title":"J Orthop Trauma"},{"key":"R24-20230714","doi-asserted-by":"crossref","first-page":"496","DOI":"10.1097\/00005131-200308000-00004","article-title":"Proximal tibial fracture stability with intramedullary nail fixation using oblique interlocking screws","volume":"17","author":"Laflamme","year":"2003","journal-title":"J Orthop Trauma"},{"key":"R25-20230714","doi-asserted-by":"crossref","first-page":"1715","DOI":"10.1007\/s00402-009-0954-1","article-title":"Double or triple interlocking when nailing proximal tibial fractures? A biomechanical investigation","volume":"129","author":"Hansen","year":"2009","journal-title":"Arch Orthop Trauma Surg"},{"key":"R26-20230714","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1097\/BOT.0b013e3181e47d0f","article-title":"The biomechanics of varied proximal locking screw configurations in a synthetic model of proximal third tibial fracture fixation","volume":"25","author":"Wolinsky","year":"2009","journal-title":"J Orthop Trauma"},{"key":"R27-20230714","doi-asserted-by":"crossref","first-page":"1495","DOI":"10.1302\/0301-620X.89B11.19018","article-title":"Anatomical study of the placement of proximal oblique locking screws in intramedullary tibial nailing","volume":"11","author":"Jones","year":"2007","journal-title":"J Bone Joint Surg Br"},{"key":"R28-20230714","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1007\/s00402-011-1380-8","article-title":"Angle stable locking nails versus conventionally locked intramedullary nails in proximal tibial shaft fractures: A biomechanical study","volume":"132","author":"Thelen","year":"2012","journal-title":"Arch Orthop Trauma Surg"},{"key":"R29-20230714","doi-asserted-by":"crossref","first-page":"726","DOI":"10.1097\/BOT.0b013e31821148c7","article-title":"Ideal tibial intramedullary nail insertion point varies with tibial rotation","volume":"25","author":"Walker","year":"2011","journal-title":"J Orthop Trauma"},{"key":"R30-20230714","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1097\/BOT.0000000000000083","article-title":"Semi-extended nailing of metaphyseal tibia fractures: Alignment and incidence of postoperative knee pain","volume":"28","author":"Ryan","year":"2014","journal-title":"J Orthop Trauma"},{"key":"R31-20230714","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1097\/BOT.0000000000000082","article-title":"Semiextended intramedullary nailing of the tibia using a suprapatellar approach: Radiographic results and clinical outcomes at a minimum of 12 months follow-up","volume":"28","author":"Sanders","year":"2014","journal-title":"J Orthop Trauma"},{"key":"R32-20230714","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1097\/BOT.0000000000000499","article-title":"Suprapatellar versus infrapatellar tibial nail insertion: A prospective randomized control pilot study","volume":"30","author":"Chan","year":"2016","journal-title":"J Orthop Trauma"},{"key":"R33-20230714","first-page":"7","article-title":"The percutaneous use of a pointed reduction clamp during intramedullary nailing of distal third tibial shaft fractures","volume":"77","author":"Forman","year":"2001","journal-title":"Acta Orthop Belg"},{"key":"R34-20230714","doi-asserted-by":"crossref","first-page":"e208","DOI":"10.1097\/BOT.0000000000000256","article-title":"Percutaneous clamping of spiral and oblique fractures of the tibial shaft: A safe and effective reduction aid during intramedullary nailing","volume":"29","author":"Collinge","year":"2015","journal-title":"J Orthop Trauma"},{"key":"R35-20230714","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/j.ocl.2013.09.001","article-title":"Techniques for intramedullary nailing of proximal tibia fractures","author":"Stinner","year":"2014","journal-title":"Orthop Clin N Am"}],"container-title":["Journal of the American Academy of Orthopaedic Surgeons"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-18-00765","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T14:50:01Z","timestamp":1787669401000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-18-00765"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,1,15]]},"references-count":35,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.5435\/jaaos-d-18-00765","relation":{},"ISSN":["1067-151X","1940-5480"],"issn-type":[{"value":"1067-151X","type":"print"},{"value":"1940-5480","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,1,15]]}}}