{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T15:29:49Z","timestamp":1787671789601,"version":"build-2736575974"},"reference-count":29,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Am Acad Orthop Surg","JAAOS"],"published-print":{"date-parts":[[2020,2,15]]},"abstract":"<jats:sec>\n                    <jats:title>Introduction:<\/jats:title>\n                    <jats:p>This study establishes the construct validity of a low-cost training platform designed for high-repetition training of the skills required for fluent use of the five specific tools described for free-hand pedicle screw placement and breach avoidance.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>A total of 19 participants were included and divided into three groups based on spine surgery experience. Participants were asked to place five pedicle screws into the model. The performance was assessed by recording breaches, technical criteria (0 to 44 points), time to completion, and angulation of the screws. Success (no breaches, no protrusions) frequency (success\/time) was calculated and analyzed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Participants included three spine surgeons, seven advanced trainees (who had placed &gt;10 pedicle screws), and nine inexperienced trainees. None of the screws placed by the spine surgeons breached the pedicle wall. Eight of 35 screws placed by advanced trainees (22.9%) and 31 of 45 screws placed by inexperienced trainees (68.9%) had a pedicle breach. Spine surgeons had a higher median success frequency compared with inexperienced trainees and advanced trainees (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.015). The time needed to place a screw decreased over time (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.0001). There was a trend toward an association between increased training level and decreased time to place five screws (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.076). Increased training level was associated with greater total points scored (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.0001). More screws placed by inexperienced trainees were further away from the ideal pedicle axis compared with those placed by advanced trainees or spine surgeons.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>An association exists between training level and performance on the pedicle screw model, which suggests construct validity when evaluating our model's use for teaching surgeon learners. The model is easily assembled and is an alternative spine surgery training tool that overcomes limited availability and considerable costs of other training platforms. It can be used in high repetition to establish tool-skill fluency.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Level of Evidence:<\/jats:title>\n                    <jats:p>Level I<\/jats:p>\n                  <\/jats:sec>","DOI":"10.5435\/jaaos-d-18-00805","type":"journal-article","created":{"date-parts":[[2019,6,14]],"date-time":"2019-06-14T23:34:49Z","timestamp":1560555289000},"page":"e172-e180","source":"Crossref","is-referenced-by-count":8,"title":["Validity of a Novel Free-Hand Pedicle Screw Placement Training Tool"],"prefix":"10.5435","volume":"28","author":[{"given":"Joseph R.","family":"Mendelis","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jaime A.","family":"Gomez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yungtai","family":"Lo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Regina","family":"Hanstein","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"I. Martin","family":"Levy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230714","doi-asserted-by":"crossref","first-page":"512","DOI":"10.4103\/0028-3886.22622","article-title":"Thoracic pedicle screw placement: Free-hand technique","volume":"53","author":"Kim","year":"2005","journal-title":"Neurol India"},{"key":"R2-20230714","doi-asserted-by":"crossref","first-page":"1151","DOI":"10.1007\/s00586-011-2065-2","article-title":"Learning curve of thoracic pedicle screw placement using the free-hand technique in scoliosis: How many screws needed for an apprentice?","volume":"21","author":"Gang","year":"2012","journal-title":"Eur Spine J"},{"key":"R3-20230714","doi-asserted-by":"crossref","first-page":"678","DOI":"10.1186\/s13104-017-3029-3","article-title":"Development of a Saw Bones Model for training pedicle screw placement in scoliosis","volume":"10","author":"Tanner","year":"2017","journal-title":"BMC Res Notes"},{"key":"R4-20230714","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1007\/BF03393163","article-title":"Behavioral fluency: evolution of a new paradigm","volume":"19","author":"Binder","year":"1996","journal-title":"Behav Anal."},{"issue":"10 suppl","key":"R5-20230714","doi-asserted-by":"crossref","first-page":"S70","DOI":"10.1097\/00001888-200410001-00022","article-title":"Deliberate practice and the acquisition and maintenance of expert performance in medicine and related domains","volume":"79","author":"Ericsson","year":"2004","journal-title":"Acad Med"},{"key":"R8-20230714","doi-asserted-by":"crossref","first-page":"402","DOI":"10.2460\/ajvr.76.5.402","article-title":"Effect of screw position on single cycle to failure in bending and torsion of a locking plate-rod construct in a synthetic feline femoral gap model","volume":"76","author":"Niederhauser","year":"2015","journal-title":"Am J Vet Res"},{"key":"R11-20230714","doi-asserted-by":"crossref","first-page":"1558","DOI":"10.1097\/00007632-200207150-00015","article-title":"Accuracy of thoracic pedicle screws in patients with and without coronal plane spinal deformities","volume":"27","author":"Belmont","year":"2002","journal-title":"Spine (Phila Pa 1976)"},{"key":"R12-20230714","doi-asserted-by":"crossref","first-page":"E465","DOI":"10.1097\/BRS.0b013e3181d1021a","article-title":"Complications of pedicle screw fixation in scoliosis surgery: A systematic review","volume":"35","author":"Hicks","year":"2010","journal-title":"Spine (Phila Pa 1976)"},{"key":"R13-20230714","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1097\/00007632-199001000-00004","article-title":"Accuracy of pedicular screw placement in vivo","volume":"15","author":"Gertzbein","year":"1990","journal-title":"Spine (Phila Pa 1976)"},{"key":"R14-20230714","doi-asserted-by":"crossref","first-page":"2049","DOI":"10.1097\/00007632-200109150-00022","article-title":"Thoracic pedicle screw fixation in spinal deformities: Are they really safe?","volume":"26","author":"Suk","year":"2001","journal-title":"Spine (Phila Pa 1976)"},{"key":"R15-20230714","doi-asserted-by":"crossref","first-page":"384","DOI":"10.1097\/BRS.0b013e3181646ba1","article-title":"Outcome-based classification for assessment of thoracic pedicular screw placement","volume":"33","author":"Upendra","year":"2008","journal-title":"Spine (Phila Pa 1976)"},{"key":"R16-20230714","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1016\/j.jamcollsurg.2006.11.010","article-title":"Evaluation of resident laparoscopic performance using global operative assessment of laparoscopic skills","volume":"204","author":"Gumbs","year":"2007","journal-title":"J Am Coll Surg"},{"key":"R17-20230714","doi-asserted-by":"crossref","first-page":"1229","DOI":"10.1177\/0363546513483535","article-title":"The arthroscopic surgical skill evaluation tool (ASSET)","volume":"41","author":"Koehler","year":"2013","journal-title":"Am J Sports Med"},{"key":"R18-20230714","doi-asserted-by":"crossref","first-page":"972","DOI":"10.1002\/bjs.7115","article-title":"Objective assessment of technical surgical skills","volume":"97","author":"van Hove","year":"2010","journal-title":"Br J Surg"},{"key":"R19-20230714","doi-asserted-by":"crossref","first-page":"72","DOI":"10.5435\/00124635-201102000-00002","article-title":"Success in orthopaedic training: Resident selection and predictors of quality performance","volume":"19","author":"Egol","year":"2011","journal-title":"J Am Acad Orthop Surg"},{"key":"R20-20230714","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1016\/S0002-9610(98)00327-4","article-title":"Assessment of technical skills transfer from the bench training model to the human model","volume":"177","author":"Anastakis","year":"1999","journal-title":"Am J Surg"},{"key":"R21-20230714","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1002\/bjs.4407","article-title":"Randomized clinical trial of virtual reality simulation for laparoscopic skills training","volume":"91","author":"Grantcharov","year":"2004","journal-title":"Br J Surg"},{"key":"R22-20230714","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1097\/01.sla.0000133346.07434.30","article-title":"The educational impact of bench model fidelity on the acquisition of technical skill: The use of clinically relevant outcome measures","volume":"240","author":"Grober","year":"2004","journal-title":"Ann Surg"},{"key":"R23-20230714","doi-asserted-by":"crossref","first-page":"1243","DOI":"10.1016\/S0022-5347(05)65274-3","article-title":"The effect of bench model fidelity on endourological skills: A randomized controlled study","volume":"167","author":"Matsumoto","year":"2002","journal-title":"J Urol"},{"key":"R24-20230714","doi-asserted-by":"crossref","first-page":"458","DOI":"10.1097\/00000658-200210000-00008","article-title":"Virtual reality training improves operating room performance: Results of a randomized, double-blinded study","volume":"236","author":"Seymour","year":"2002","journal-title":"Ann Surg"},{"key":"R25-20230714","doi-asserted-by":"crossref","first-page":"50","DOI":"10.3109\/17453674.2010.548032","article-title":"The rate of screw misplacement in segmental pedicle screw fixation in adolescent idiopathic scoliosis","volume":"82","author":"Abul-Kasim","year":"2011","journal-title":"Acta Orthop"},{"key":"R26-20230714","doi-asserted-by":"crossref","first-page":"778","DOI":"10.3171\/2014.7.SPINE1489","article-title":"Freehand thoracic pedicle screw technique using a uniform entry point and sagittal trajectory for all levels: Preliminary clinical experience","volume":"21","author":"Fennell","year":"2014","journal-title":"J Neurosurg Spine"},{"key":"R27-20230714","doi-asserted-by":"crossref","first-page":"E548","DOI":"10.1097\/BRS.0000000000001318","article-title":"Are we underestimating the significance of pedicle screw misplacement?","volume":"41","author":"Sarwahi","year":"2016","journal-title":"Spine (Phila Pa 1976)"},{"key":"R28-20230714","doi-asserted-by":"crossref","first-page":"1836","DOI":"10.1097\/BRS.0b013e3181d3cfde","article-title":"A novel pedicle channel classification describing osseous anatomy: How many thoracic scoliotic pedicles have cancellous channels?","volume":"35","author":"Watanabe","year":"2010","journal-title":"Spine (Phila Pa 1976)"},{"key":"R29-20230714","first-page":"178","article-title":"Development of an orthopaedic surgical skills curriculum for post-graduate year one resident learners: The University of Iowa experience","volume":"33","author":"Karam","year":"2013","journal-title":"Iowa Orthop J"},{"key":"R30-20230714","doi-asserted-by":"crossref","first-page":"e140","DOI":"10.2106\/JBJS.M.01414","article-title":"A surgical skills training curriculum for PGY-1 residents: AAOS exhibit selection","volume":"96","author":"Westerlind","year":"2014","journal-title":"J Bone Joint Surg Am"},{"key":"R31-20230714","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1186\/s13018-018-0788-z","article-title":"Use of a life-size three-dimensional-printed spine model for pedicle screw instrumentation training","volume":"13","author":"Park","year":"2018","journal-title":"J Orthop Surg Res"},{"key":"R32-20230714","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1007\/s00586-011-2011-3","article-title":"Accuracy of pedicle screw placement: A systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques","volume":"21","author":"Gelalis","year":"2012","journal-title":"Eur Spine J"},{"key":"R33-20230714","doi-asserted-by":"crossref","first-page":"228","DOI":"10.7555\/JBR.28.20130159","article-title":"Position and complications of pedicle screw insertion with or without image-navigation techniques in the thoracolumbar spine: A meta-analysis of comparative studies","volume":"28","author":"Tang","year":"2014","journal-title":"J Biomed Res"}],"container-title":["Journal of the American Academy of Orthopaedic Surgeons"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-18-00805","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T14:49:56Z","timestamp":1787669396000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-18-00805"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,2,15]]},"references-count":29,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.5435\/jaaos-d-18-00805","relation":{},"ISSN":["1067-151X","1940-5480"],"issn-type":[{"value":"1067-151X","type":"print"},{"value":"1940-5480","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,2,15]]}}}