{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,18]],"date-time":"2026-10-18T05:32:26Z","timestamp":1792301546983,"version":"4.4.0"},"reference-count":24,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["J Am Acad Orthop Surg","JAAOS"],"published-print":{"date-parts":[[2021,3,1]]},"abstract":"<jats:sec>\n                    <jats:title>Introduction:<\/jats:title>\n                    <jats:p>Acute patellar tendon ruptures are frequently observed in patients with metabolic comorbidities, and the benchmark treatment is surgical repair. It is desirable not to harm an already fragile biologic environment with sutures and hardware. We aimed to compare the mechanical requirements of an isolated, flexible, high-strength nonabsorbable transosseous suture frame with that of the Krackow suture technique.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>A total of 12 cadaveric pieces were randomized into two groups: the isolated flexible frame group (n = 6) and the standard Krackow fixation group (n = 6). A traumatic rupture of the patellar tendon was performed, and a transosseous displacement sensor was installed on a validated biomechanical system. Gap formation was measured during 50 cycles of flexion and extension with traction on the quadriceps (250 N). Subsequently, specimens underwent progressive loading in a fixed flexion position until failure occurred. The data were analyzed using nonparametric statistical tools with a significance level of 5%.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      The isolated frame group had a smaller gap formation (1.7 mm) than the Krackow group (3.4 mm;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.01). No significant difference existed in the median failure end points of the two groups (676 and 530 N, respectively;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.11).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Discussion:<\/jats:title>\n                    <jats:p>Patellar tendon repair using an isolated, transosseous, flexible, suture frame outperformed using the traditional Krakow repair technique in gap formation. Further studies are needed to determine if this will result in better functional outcomes or fewer clinical failures.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Level of Evidence:<\/jats:title>\n                    <jats:p>Level IV, experimental case series<\/jats:p>\n                  <\/jats:sec>","DOI":"10.5435\/jaaos-d-19-00509","type":"journal-article","created":{"date-parts":[[2020,6,27]],"date-time":"2020-06-27T04:29:32Z","timestamp":1593232172000},"page":"e251-e257","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":7,"title":["An Isolated Transosseous Flexible Suture Frame in the Treatment of Patellar Tendon Rupture Provides Adequate Mechanical Resistance"],"prefix":"10.5435","volume":"29","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6690-1678","authenticated-orcid":false,"given":"Pablo","family":"Besa","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2644-7906","authenticated-orcid":false,"given":"Alberto","family":"Telias","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francisca","family":"Orrego","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0567-4867","authenticated-orcid":false,"given":"Rodrigo","family":"Guzm\u00e1n-Venegas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5756-569X","authenticated-orcid":false,"given":"Mart\u00edn","family":"Cariola","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Diego","family":"Amen\u00e1bar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1342-2961","authenticated-orcid":false,"given":"Felipe H.","family":"Palma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1215-1709","authenticated-orcid":false,"given":"Sebasti\u00e1n","family":"Irarr\u00e1zaval","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mario","family":"Orrego","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2021,3,1]]},"reference":[{"key":"R1-20250503","doi-asserted-by":"crossref","first-page":"S67","DOI":"10.1016\/j.otsr.2012.12.002","article-title":"Acute and old ruptures of the extensor apparatus of the knee in adults (excluding knee replacement)","volume":"99","author":"Saragaglia","year":"2013","journal-title":"Orthop Traumatol Surg Res"},{"key":"R2-20250503","doi-asserted-by":"crossref","first-page":"336","DOI":"10.1055\/s-0036-1586725","article-title":"Repair of acute patellar tendon rupture augmented with strong sutures","volume":"30","author":"Otsubo","year":"2016","journal-title":"J Knee Surg"},{"key":"R3-20250503","doi-asserted-by":"crossref","first-page":"287","DOI":"10.5435\/00124635-199611000-00001","article-title":"Patellar tendon ruptures","volume":"4","author":"Matava","year":"1996","journal-title":"J Am Acad Orthop Surg"},{"key":"R4-20250503","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1177\/03635465020300040301","article-title":"Biomechanical comparison of patellar tendon repairs in a cadaver model: An evaluation of gap formation at the repair site with cyclic loading","volume":"30","author":"Ravalin","year":"2002","journal-title":"Am J Sports Med"},{"key":"R5-20250503","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1186\/s40634-017-0084-6","article-title":"Biomechanical cadaveric comparison of patellar ligament suture protected by a steel cable versus a synthetic cable","volume":"4","author":"Bouget","year":"2017","journal-title":"J Exp Orthop"},{"key":"R6-20250503","doi-asserted-by":"crossref","first-page":"1507","DOI":"10.2106\/00004623-199173100-00009","article-title":"Histopathological changes preceding spontaneous rupture of a tendon: A controlled study of 891 patients","volume":"73","author":"Kannus","year":"1991","journal-title":"J Bone Joint Surg Am"},{"key":"R7-20250503","doi-asserted-by":"crossref","first-page":"1153","DOI":"10.1007\/s00264-009-0879-x","article-title":"Repair of fresh patellar tendon rupture: Tension regulation at the suture line","volume":"34","author":"Massoud","year":"2010","journal-title":"Int Orthop"},{"key":"R8-20250503","doi-asserted-by":"crossref","first-page":"2540","DOI":"10.1177\/0363546513500633","article-title":"Biomechanical properties of suture anchor repair compared with transosseous sutures in patellar tendon ruptures","volume":"41","author":"Ettinger","year":"2013","journal-title":"Am J Sports Med"},{"key":"R9-20250503","doi-asserted-by":"crossref","first-page":"1717","DOI":"10.1007\/s00264-015-3003-4","article-title":"Biomechanical evaluation of different surgical techniques for treating patellar tendon ruptures","volume":"40","author":"Schliemann","year":"2016","journal-title":"Int Orthop"},{"key":"R10-20250503","doi-asserted-by":"crossref","first-page":"2611","DOI":"10.1007\/s11999-016-5009-7","article-title":"Novel augmentation technique for patellar tendon repair improves strength and decreases gap formation: A cadaveric study","volume":"474","author":"Black","year":"2016","journal-title":"Clin Orthop Relat Res"},{"key":"R11-20250503","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1097\/BOT.0b013e318191c353","article-title":"Patellar tendon repair with suture anchors using a combined suture technique of a Krackow-Bunnell weave","volume":"23","author":"Gaines","year":"2009","journal-title":"J Orthop Trauma"},{"key":"R12-20250503","doi-asserted-by":"crossref","first-page":"1492","DOI":"10.1177\/0363546506287489","article-title":"The use of suture anchors in repair of the ruptured patellar tendon","volume":"34","author":"Bushnell","year":"2006","journal-title":"Am J Sports Med"},{"key":"R13-20250503","doi-asserted-by":"crossref","first-page":"685","DOI":"10.1007\/s00113-007-1269-8","article-title":"Augmentation von Patellafrakturen und Patellarsehnenrupturen mittels McLaughlin-Cerclage","volume":"110","author":"Ahrberg","year":"2007","journal-title":"Unfallchirurg"},{"key":"R14-20250503","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1177\/0363546507308192","article-title":"Early motion after quadriceps and patellar tendon repairs","volume":"36","author":"West","year":"2008","journal-title":"Am J Sports Med"},{"key":"R15-20250503","doi-asserted-by":"crossref","first-page":"1969","DOI":"10.2106\/JBJS.17.01364","article-title":"Minimally invasive versus open repair for acute Achilles tendon rupture: Meta-analysis showing reduced complications, with similar outcomes, after minimally invasive surgery","volume":"100","author":"Grassi","year":"2018","journal-title":"J Bone Joint Surg Am"},{"key":"R16-20250503","doi-asserted-by":"crossref","first-page":"1957","DOI":"10.1177\/0363546515587082","article-title":"A biomechanical comparison of an open repair and 3 minimally invasive percutaneous Achilles tendon repair techniques during a simulated, progressive rehabilitation protocol","volume":"43","author":"Clanton","year":"2015","journal-title":"Am J Sports Med"},{"key":"R17-20250503","doi-asserted-by":"crossref","first-page":"2325967117701212","DOI":"10.1177\/2325967116S00078","article-title":"Tape versus suture\u2014A biomechanical and clinical analysis in arthroscopic rotator cuff repair of large tears","volume":"4","author":"Ruiwen","year":"2016","journal-title":"Orthop J Sport Med"},{"key":"R18-20250503","doi-asserted-by":"crossref","first-page":"789","DOI":"10.1007\/s00776-012-0275-z","article-title":"The failure mode of two reabsorbable fixation systems: Swivelock with Fibertape versus Bio-Corkscrew with Fiberwire in bovine rotator cuff","volume":"17","author":"De Carli","year":"2012","journal-title":"J Orthop Sci"},{"key":"R19-20250503","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1177\/0363546509343802","article-title":"Gap formation in transpatellar patellar tendon repair","volume":"38","author":"Krushinski","year":"2010","journal-title":"Am J Sports Med"},{"key":"R21-20250503","doi-asserted-by":"crossref","first-page":"975","DOI":"10.2106\/00004623-199907000-00010","article-title":"The effect of gap formation at the repair site on the strength and excursion of intrasynovial flexor tendons: An experimental study on the early stages of tendon-healing in dogs","volume":"81","author":"Gelberman","year":"1999","journal-title":"J Bone Joint Surg Am"},{"key":"R22-20250503","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1016\/j.knee.2014.10.007","article-title":"Reconstruction techniques and clinical results of patellar tendon ruptures: Evidence today","volume":"22","author":"Gilmore","year":"2015","journal-title":"Knee"},{"key":"R23-20250503","doi-asserted-by":"crossref","first-page":"825","DOI":"10.1055\/s-0038-1669790","article-title":"Biomechanical evaluation of suture anchor versus transosseous tunnel patellar tendon repair techniques","volume":"32","author":"Sherman","year":"2019","journal-title":"J Knee Surg"},{"key":"R24-20250503","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/j.injury.2003.11.015","article-title":"Stress fracture patella following patella tendon repair","volume":"35","author":"Singh","year":"2004","journal-title":"Inj Extra"},{"key":"R25-20250503","doi-asserted-by":"crossref","first-page":"616","DOI":"10.1016\/S0268-0033(98)00013-8","article-title":"The effects of axial and multi-plane loading of the extensor mechanism on the patellofemoral joint","volume":"13","author":"Powers","year":"1998","journal-title":"Clin Biomech (Bristol, Avon)"}],"container-title":["Journal of the American Academy of Orthopaedic Surgeons"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-19-00509","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T14:46:54Z","timestamp":1787669214000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-19-00509"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,3,1]]},"references-count":24,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.5435\/jaaos-d-19-00509","relation":{},"ISSN":["1067-151X","1940-5480"],"issn-type":[{"value":"1067-151X","type":"print"},{"value":"1940-5480","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,3,1]]},"assertion":[{"value":"2019-08-07","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-05-22","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}