{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,10]],"date-time":"2026-11-10T13:24:44Z","timestamp":1794317084143,"version":"4.9.0"},"reference-count":34,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"16","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Am Acad Orthop Surg","JAAOS"],"published-print":{"date-parts":[[2020,8,15]]},"abstract":"<jats:p>Hip arthroscopy is rapidly growing as a treatment with good outcomes for pathologic conditions such as femoroacetabular impingement syndrome and labral tears. At the same time, it is one of the most technically challenging and demanding procedures in orthopaedics with a technically demanding skill. The first challenge is to safely access the joint, which requires accurate anatomical knowledge, a strong sense of spatial orientation, and repeated practice. Iatrogenic chondrolabral injury has been reported as the most common complication in hip arthroscopy and most frequently occurs during hip joint access. As such, basic foundations cannot be overstated. These complications can be minimized with adequate patient positioning, reproducible hip joint access techniques, and proper portals placement. Nonetheless, these three points are perhaps the greatest hurdles that orthopaedic surgeons face when entering the hip arthroscopy field. In this review, we outlined a stepwise approach for a safe access to hip arthroscopy.<\/jats:p>","DOI":"10.5435\/jaaos-d-19-00856","type":"journal-article","created":{"date-parts":[[2020,5,26]],"date-time":"2020-05-26T00:11:47Z","timestamp":1590451907000},"page":"651-659","source":"Crossref","is-referenced-by-count":44,"title":["Stepwise Safe Access in Hip Arthroscopy in the Supine Position: Tips and Pearls From A to Z"],"prefix":"10.5435","volume":"28","author":[{"given":"David R.","family":"Maldonado","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8914-4769","authenticated-orcid":false,"given":"Philip J.","family":"Rosinsky","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jacob","family":"Shapira","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3937-8647","authenticated-orcid":false,"given":"Benjamin G.","family":"Domb","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2020,5,22]]},"reference":[{"key":"R1-20230714","doi-asserted-by":"crossref","first-page":"81","DOI":"10.5435\/JAAOS-D-18-00041","article-title":"Best practice guidelines for hip arthroscopy in femoroacetabular impingement: Results of a Delphi process","volume":"28","author":"Lynch","year":"2020","journal-title":"J Am Acad Orthop Surg"},{"key":"R2-20230714","doi-asserted-by":"crossref","first-page":"1284","DOI":"10.1177\/0363546517749219","article-title":"Defining the learning curve for hip arthroscopy: A threshold analysis of the volume-outcomes relationship","volume":"46","author":"Mehta","year":"2018","journal-title":"Am J Sports Med"},{"key":"R3-20230714","doi-asserted-by":"crossref","first-page":"1342","DOI":"10.1016\/j.arthro.2014.04.103","article-title":"Safety measures in hip arthroscopy and their efficacy in minimizing complications: A systematic review of the evidence","volume":"30","author":"Gupta","year":"2014","journal-title":"Arthroscopy"},{"key":"R4-20230714","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1016\/j.arthro.2012.11.003","article-title":"Complications and reoperations during and after hip arthroscopy: A systematic review of 92 studies and more than 6,000 patients","volume":"29","author":"Harris","year":"2013","journal-title":"Arthroscopy"},{"key":"R5-20230714","doi-asserted-by":"crossref","first-page":"e575","DOI":"10.1016\/j.eats.2019.01.017","article-title":"Forget the greater trochanter! Hip joint access with the 12 O'clock portal in hip arthroscopy","volume":"8","author":"Maldonado","year":"2019","journal-title":"Arthrosc Tech"},{"key":"R6-20230714","doi-asserted-by":"crossref","first-page":"716","DOI":"10.1016\/j.arthro.2015.12.028","article-title":"A comparison of supine and lateral decubitus positions for hip arthroscopy: A systematic review of outcomes and complications","volume":"32","author":"de Sa","year":"2016","journal-title":"Arthroscopy"},{"key":"R7-20230714","doi-asserted-by":"crossref","first-page":"1277","DOI":"10.1007\/s12630-016-0718-7","article-title":"Anesthesia for hip arthroscopy: A narrative review","volume":"63","author":"Yu","year":"2016","journal-title":"Can J Anaesth"},{"key":"R8-20230714","first-page":"325","article-title":"Hip arthroscopy by the supine approach","volume":"55","author":"Byrd","year":"2006","journal-title":"Instr Course Lect"},{"key":"R9-20230714","doi-asserted-by":"crossref","first-page":"703","DOI":"10.1016\/S0278-5919(05)70280-5","article-title":"Hip arthroscopy: The supine position","volume":"20","author":"Byrd","year":"2001","journal-title":"Clin Sports Med"},{"key":"R10-20230714","doi-asserted-by":"crossref","first-page":"733","DOI":"10.1016\/S0278-5919(05)70281-7","article-title":"Hip arthroscopy: The lateral approach","volume":"20","author":"Glick","year":"2001","journal-title":"Clin Sports Med"},{"key":"R11-20230714","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1007\/s00402-016-2572-z","article-title":"Patient-specific factors influencing the traction forces in hip arthroscopy","volume":"137","author":"Ellenrieder","year":"2017","journal-title":"Arch Orthop Trauma Surg"},{"key":"R12-20230714","doi-asserted-by":"crossref","first-page":"773","DOI":"10.5435\/JAAOS-D-17-00230","article-title":"Incidence of nerve injury after hip arthroscopy","volume":"26","author":"Kern","year":"2018","journal-title":"J Am Acad Orthop Surg"},{"key":"R13-20230714","doi-asserted-by":"crossref","first-page":"969","DOI":"10.1007\/s00167-017-4783-4","article-title":"Pudendal nerve injury is a relatively common but transient complication of hip arthroscopy","volume":"26","author":"Habib","year":"2018","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"R14-20230714","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.3928\/01477447-20121217-10","article-title":"Hip arthroscopy distraction without the use of a perineal post: Prospective study","volume":"36","author":"Mei-Dan","year":"2013","journal-title":"Orthopedics"},{"key":"R15-20230714","doi-asserted-by":"crossref","first-page":"632","DOI":"10.1177\/0363546517741704","article-title":"Hip distraction without a perineal post: A prospective study of 1000 hip arthroscopy cases","volume":"46","author":"Mei-Dan","year":"2018","journal-title":"Am J Sports Med"},{"key":"R16-20230714","doi-asserted-by":"crossref","first-page":"e363","DOI":"10.1016\/j.eats.2018.11.013","article-title":"Achieving post-free distraction in hip arthroscopy with a pink pad patient positioning device using standard hip distraction tables","volume":"8","author":"Kollmorgen","year":"2019","journal-title":"Arthrosc Tech"},{"key":"R17-20230714","doi-asserted-by":"crossref","first-page":"1931","DOI":"10.1177\/0363546519849663","article-title":"Effects of hip arthroscopy without a perineal post on venous blood flow, muscle damage, peripheral nerve conduction, and perineal injury: A prospective study","volume":"47","author":"Welton","year":"2019","journal-title":"Am J Sports Med"},{"key":"R18-20230714","doi-asserted-by":"crossref","first-page":"1851","DOI":"10.1097\/CORR.0000000000000804","article-title":"Perineal pressure during hip arthroscopy is reduced by use of Trendelenburg: A prospective study with randomized order of positioning","volume":"477","author":"Lall","year":"2019","journal-title":"Clin Orthop Relat Res"},{"key":"R19-20230714","doi-asserted-by":"crossref","first-page":"1804","DOI":"10.1016\/j.arthro.2017.03.026","article-title":"Fluoroscopy learning curve in hip arthroscopy: A single surgeon's experience","volume":"33","author":"Smith","year":"2017","journal-title":"Arthroscopy"},{"key":"R20-20230714","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1177\/1120700019887362","article-title":"Intraoperative radiation exposure in hip arthroscopy: A systematic review","volume":"30","author":"Shah","year":"2020","journal-title":"Hip Int"},{"key":"R21-20230714","doi-asserted-by":"crossref","first-page":"1261","DOI":"10.1016\/j.arthro.2015.01.017","article-title":"Cumulative radiation exposure to patients undergoing arthroscopic hip preservation surgery and occupational radiation exposure to the surgical team","volume":"31","author":"Canham","year":"2015","journal-title":"Arthroscopy"},{"key":"R22-20230714","doi-asserted-by":"crossref","first-page":"e247","DOI":"10.1016\/j.eats.2015.12.003","article-title":"Basic hip arthroscopy: Anatomic establishment of arthroscopic portals without fluoroscopic guidance","volume":"5","author":"Howse","year":"2016","journal-title":"Arthrosc Tech"},{"key":"R23-20230714","doi-asserted-by":"crossref","first-page":"864","DOI":"10.1177\/0363546512437152","article-title":"Labral penetration rate in a consecutive series of 300 hip arthroscopies","volume":"40","author":"Domb","year":"2012","journal-title":"Am J Sports Med"},{"key":"R24-20230714","doi-asserted-by":"crossref","first-page":"e851","DOI":"10.1016\/j.eats.2016.04.006","article-title":"Ultrasound-guided portal placement for hip arthroscopy","volume":"5","author":"Keough","year":"2016","journal-title":"Arthrosc Tech"},{"key":"R25-20230714","doi-asserted-by":"crossref","first-page":"2061","DOI":"10.1177\/0363546518779064","article-title":"In search of the spherical femoroplasty: Cam overresection leads to inferior functional scores before and after revision hip arthroscopic surgery","volume":"46","author":"Mansor","year":"2018","journal-title":"Am J Sports Med"},{"key":"R26-20230714","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1016\/0749-8063(95)90193-0","article-title":"Hip arthroscopy: An anatomic study of portal placement and relationship to the extra-articular structures","volume":"11","author":"Byrd","year":"1995","journal-title":"Arthroscopy"},{"key":"R27-20230714","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1016\/S0749-8063(05)80111-2","article-title":"Hip arthroscopy utilizing the supine position","volume":"10","author":"Byrd","year":"1994","journal-title":"Arthroscopy"},{"key":"R28-20230714","doi-asserted-by":"crossref","first-page":"e469","DOI":"10.1016\/j.eats.2014.05.005","article-title":"The modified mid-anterior portal for hip arthroscopy","volume":"3","author":"Matsuda","year":"2014","journal-title":"Arthrosc Tech"},{"key":"R29-20230714","doi-asserted-by":"crossref","first-page":"e883","DOI":"10.1016\/j.eats.2019.04.003","article-title":"Do not take for granted! The art of elevating the capsule in hip arthroscopy: A stepwise approach","volume":"8","author":"Maldonado","year":"2019","journal-title":"Arthrosc Tech"},{"key":"R30-20230714","doi-asserted-by":"crossref","first-page":"e671","DOI":"10.1016\/j.eats.2016.02.025","article-title":"Arthroscopic technique for acetabular labral reconstruction using iliotibial band autograft","volume":"5","author":"Chahla","year":"2016","journal-title":"Arthrosc Tech"},{"key":"R31-20230714","doi-asserted-by":"crossref","first-page":"2348","DOI":"10.1007\/s00167-012-2137-9","article-title":"Accessibility of extra-articular pathologies of iliopsoas tendon and bursitis of greater trochanter in hip arthroscopy","volume":"20","author":"Thorey","year":"2012","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"R32-20230714","doi-asserted-by":"crossref","first-page":"1510","DOI":"10.1016\/j.arthro.2005.09.014","article-title":"Safe arthroscopic access to the central compartment of the hip","volume":"21","author":"Dienst","year":"2005","journal-title":"Arthroscopy"},{"key":"R33-20230714","doi-asserted-by":"crossref","first-page":"e723","DOI":"10.1016\/j.eats.2014.09.003","article-title":"Arthroscopy of the nondistractable hip: A novel extracapsular approach","volume":"3","author":"Doron","year":"2014","journal-title":"Arthrosc Tech"},{"key":"R34-20230714","doi-asserted-by":"crossref","first-page":"2338","DOI":"10.1016\/j.arthro.2019.01.055","article-title":"Arthroscopic outcomes as a function of acetabular coverage from a large hip arthroscopy study group","volume":"35","author":"Matsuda","year":"2019","journal-title":"Arthroscopy"}],"container-title":["Journal of the American Academy of Orthopaedic Surgeons"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-19-00856","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T14:42:38Z","timestamp":1787668958000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-19-00856"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,5,22]]},"references-count":34,"journal-issue":{"issue":"16","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.5435\/jaaos-d-19-00856","relation":{},"ISSN":["1067-151X","1940-5480"],"issn-type":[{"value":"1067-151X","type":"print"},{"value":"1940-5480","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,5,22]]}}}