{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,10]],"date-time":"2026-11-10T12:18:54Z","timestamp":1794313134999,"version":"4.9.0"},"reference-count":46,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"11","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["J Am Acad Orthop Surg","JAAOS"],"published-print":{"date-parts":[[2021,6,1]]},"abstract":"<jats:p>Proximal humerus fractures are common, particularly in elderly patients and those with osteopenia or osteoporosis. Although nonsurgical management results in satisfactory outcomes for most patients, surgical treatment is indicated in select cases. Despite an increasing trend toward arthroplasty, open reduction and internal fixation of proximal humerus fractures can still provide excellent clinical outcomes. Proper technique for internal fixation of the proximal humerus requires an understanding of osseous and neurovascular anatomy. In particular, understanding reliable regions of biomechanically superior bone can help prevent failure of fixation. Biomechanical studies have shown that locked plating of proximal humerus fractures provides stable fixation. Cadaveric and finite element models underscore the importance of screw placement in the posteromedial metaphysis. When medial column support is challenging to obtain, or when bone quality is poor, augmentation with bone autograft, allograft, and\/or synthetic composites can improve the biomechanics of internal fixation constructs. The purpose of this review is to outline the anatomic, biologic, and biomechanical principles of plate fixation for proximal humerus fractures to provide evidence-based recommendations for optimizing fixation and preventing fixation failure.<\/jats:p>","DOI":"10.5435\/jaaos-d-20-00558","type":"journal-article","created":{"date-parts":[[2021,2,13]],"date-time":"2021-02-13T12:36:26Z","timestamp":1613219786000},"page":"e523-e535","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":44,"title":["Principles of Locking Plate Fixation of Proximal Humerus Fractures"],"prefix":"10.5435","volume":"29","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7506-8734","authenticated-orcid":false,"given":"Reza","family":"Omid","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9458-8623","authenticated-orcid":false,"given":"Nicholas A.","family":"Trasolini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9024-9584","authenticated-orcid":false,"given":"Michael A.","family":"Stone","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Surena","family":"Namdari","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2021,2,4]]},"reference":[{"key":"R1-20250503","doi-asserted-by":"crossref","first-page":"2072","DOI":"10.1016\/j.jse.2019.03.034","article-title":"Nationwide trends in management of proximal humeral fractures: An analysis of 77,966 cases from 2008 to 2017","volume":"28","author":"McLean","year":"2019","journal-title":"J Shoulder Elbow Surg"},{"key":"R2-20250503","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1177\/1758573217736744","article-title":"Cortical thickness analysis of the proximal humerus","volume":"11","author":"Majed","year":"2019","journal-title":"Shoulder Elbow"},{"key":"R3-20250503","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1016\/j.jse.2004.01.034","article-title":"Predictors of humeral head ischemia after intracapsular fracture of the proximal humerus","volume":"13","author":"Hertel","year":"2004","journal-title":"J Shoulder Elbow Surg"},{"key":"R4-20250503","doi-asserted-by":"crossref","first-page":"943","DOI":"10.2106\/JBJS.H.01144","article-title":"Quantitative assessment of the vascularity of the proximal part of the humerus","volume":"92","author":"Hettrich","year":"2010","journal-title":"J Bone Joint Surg Am"},{"key":"R5-20250503","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1302\/0301-620X.75B1.8421010","article-title":"Vascularity of the humeral head after proximal humeral fractures. An anatomical cadaver study","volume":"75","author":"Brooks","year":"1993","journal-title":"J Bone Joint Surg Br"},{"key":"R6-20250503","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1007\/s00276-019-02356-y","article-title":"Quantitative localization of the entry point of the lateral ascending branch of the anterior circumflex humeral artery: A high definition CT-scan radiological study","volume":"42","author":"Sergent","year":"2020","journal-title":"Surg Radiol Anat"},{"key":"R7-20250503","doi-asserted-by":"crossref","first-page":"766","DOI":"10.1302\/0301-620X.91B6.22109","article-title":"The impact of stereo-visualisation of three-dimensional CT datasets on the inter- and intraobserver reliability of the AO\/OTA and Neer classifications in the assessment of fractures of the proximal humerus","volume":"91-B","author":"Brunner","year":"2009","journal-title":"J Bone Joint Surg Br"},{"key":"R8-20250503","doi-asserted-by":"crossref","first-page":"1077","DOI":"10.2106\/00004623-197052060-00001","article-title":"Displaced proximal humeral fractures. I. Classification and evaluation","volume":"52","author":"Neer","year":"1970","journal-title":"J Bone Joint Surg Am"},{"key":"R9-20250503","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1097\/BOT.0000000000001063","article-title":"Fracture and Dislocation Classification Compendium\u20142018","volume":"32","author":"Meinberg","year":"2018","journal-title":"J Orthop Trauma"},{"key":"R10-20250503","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1186\/s10195-020-0543-1","article-title":"Reliability and reproducibility of the new AO\/OTA 2018 classification system for proximal humeral fractures: A comparison of three different classification systems","volume":"21","author":"Marongiu","year":"2020","journal-title":"J Orthop Traumatol"},{"key":"R11-20250503","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1097\/00003086-200003000-00016","article-title":"Osteoporosis","volume":"372","author":"Lane","year":"2000","journal-title":"Clin Orthop Relat Res"},{"key":"R12-20250503","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1007\/s00223-017-0279-y","article-title":"High-resolution tomography-based quantification of cortical porosity and cortical thickness at the surgical neck of the humerus during aging","volume":"101","author":"Helfen","year":"2017","journal-title":"Calcif Tissue Int"},{"key":"R13-20250503","doi-asserted-by":"crossref","first-page":"3038","DOI":"10.1007\/s11999-015-4322-x","article-title":"Deltoid tuberosity index: A simple radiographic tool to assess local bone quality in proximal humerus fractures","volume":"473","author":"Spross","year":"2015","journal-title":"Clin Orthop Relat Res"},{"key":"R14-20250503","doi-asserted-by":"crossref","first-page":"611","DOI":"10.1302\/0301-620X.85B4.12843","article-title":"The cortical thickness of the proximal humeral diaphysis predicts bone mineral density of the proximal humerus","volume":"85-B","author":"Tingart","year":"2003","journal-title":"J Bone Joint Surg Br"},{"key":"R15-20250503","doi-asserted-by":"crossref","first-page":"12","DOI":"10.5435\/00124635-200701000-00003","article-title":"Innovations in the management of displaced proximal humerus fractures","volume":"15","author":"Nho","year":"2007","journal-title":"J Am Acad Orthop Surg"},{"key":"R16-20250503","doi-asserted-by":"crossref","first-page":"1689","DOI":"10.1016\/j.jse.2019.11.026","article-title":"Locking plate fixation of proximal humerus fractures in patients older than 60 years continues to be associated with a high complication rate","volume":"29","author":"Barlow","year":"2020","journal-title":"J Shoulder Elbow Surg"},{"key":"R17-20250503","doi-asserted-by":"crossref","first-page":"2129","DOI":"10.2106\/JBJS.19.00595","article-title":"Complications and long-term outcomes of open reduction and plate fixation of proximal humeral fractures","volume":"101","author":"Robinson","year":"2019","journal-title":"J Bone Joint Surg Am"},{"key":"R18-20250503","doi-asserted-by":"crossref","first-page":"1283","DOI":"10.1016\/j.injury.2011.01.017","article-title":"Predicting failure after surgical fixation of proximal humerus fractures","volume":"42","author":"Krappinger","year":"2011","journal-title":"Injury"},{"key":"R19-20250503","doi-asserted-by":"crossref","first-page":"1566","DOI":"10.1016\/j.jse.2017.02.026","article-title":"How bone quality may influence intraoperative and early postoperative problems after angular stable open reduction\u2013internal fixation of proximal humeral fractures","volume":"26","author":"Spross","year":"2017","journal-title":"J Shoulder Elbow Surg"},{"key":"R20-20250503","doi-asserted-by":"crossref","first-page":"222","DOI":"10.1097\/BOT.0b013e31822421f7","article-title":"Relationship of cortical thickness of the proximal humerus and pullout strength of a locked plate and screw construct","volume":"26","author":"Wallace","year":"2012","journal-title":"J Orthop Trauma"},{"key":"R21-20250503","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1016\/j.jse.2019.06.014","article-title":"Failure to restore the calcar and locking screw cross-threading predicts varus collapse in proximal humerus fracture fixation","volume":"29","author":"Padegimas","year":"2020","journal-title":"J Shoulder Elbow Surg"},{"key":"R22-20250503","doi-asserted-by":"crossref","first-page":"1777","DOI":"10.2106\/JBJS.16.00112","article-title":"Quality of reduction influences outcome after locked-plate fixation of proximal humeral type-C fractures","volume":"98","author":"Schnetzke","year":"2016","journal-title":"J Bone Joint Surg Am"},{"key":"R23-20250503","doi-asserted-by":"crossref","first-page":"1931","DOI":"10.1016\/j.jse.2017.05.003","article-title":"Defining optimal calcar screw positioning in proximal humerus fracture fixation","volume":"26","author":"Padegimas","year":"2017","journal-title":"J Shoulder Elbow Surg"},{"key":"R24-20250503","doi-asserted-by":"crossref","first-page":"624","DOI":"10.1016\/j.injury.2018.02.007","article-title":"Calcar screw position in proximal humerus fracture fixation: Don't miss high!","volume":"49","author":"Mehta","year":"2018","journal-title":"Injury"},{"key":"R25-20250503","doi-asserted-by":"crossref","first-page":"957","DOI":"10.1002\/jor.24235","article-title":"Importance of locking plate positioning in proximal humeral fractures as predicted by computer simulations","volume":"37","author":"Fletcher","year":"2019","journal-title":"J Orthop Res"},{"key":"R26-20250503","doi-asserted-by":"crossref","first-page":"663","DOI":"10.1097\/BOT.0000000000000997","article-title":"Cadaveric analysis of proximal humerus locking plate fit: Contour mismatch may lead to malreduction","volume":"31","author":"Ravindra","year":"2017","journal-title":"J Orthop Trauma"},{"key":"R27-20250503","doi-asserted-by":"crossref","first-page":"620","DOI":"10.1016\/j.jse.2005.09.007","article-title":"Proximal humeral fractures: Regional differences in bone mineral density of the humeral head affect the fixation strength of cancellous screws","volume":"15","author":"Tingart","year":"2006","journal-title":"J Shoulder Elbow Surg"},{"key":"R28-20250503","doi-asserted-by":"crossref","first-page":"452","DOI":"10.1097\/BOT.0000000000000057","article-title":"Effect of calcar screw use in surgical neck fractures of the proximal humerus with unstable medial support: A biomechanical study","volume":"28","author":"Bai","year":"2014","journal-title":"J Orthop Trauma"},{"key":"R29-20250503","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s13018-018-1031-7","article-title":"Inferomedial cortical bone contact and fixation with calcar screws on the dynamic and static mechanical stability of proximal humerus fractures","volume":"14","author":"Zhang","year":"2019","journal-title":"J Orthop Surg Res"},{"key":"R30-20250503","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1097\/BOT.0b013e3180333094","article-title":"The importance of medial support in locked plating of proximal humerus fractures","volume":"21","author":"Gardner","year":"2007","journal-title":"J Orthop Trauma"},{"key":"R31-20250503","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1097\/BOT.0000000000001112","article-title":"Biomechanical comparison of 3 inferiorly directed versus 3 superiorly directed locking screws on stability in a 3-part proximal humerus fracture model","volume":"32","author":"Donohue","year":"2018","journal-title":"J Orthop Trauma"},{"key":"R32-20250503","doi-asserted-by":"crossref","first-page":"306","DOI":"10.3928\/01477447-20180828-04","article-title":"Proximal humeral locking plates: A cadaveric study of 5 versus 7 metaphyseal locking screws","volume":"41","author":"Lindsay","year":"2018","journal-title":"Orthopedics"},{"key":"R33-20250503","doi-asserted-by":"crossref","first-page":"1816","DOI":"10.1016\/j.jse.2019.02.013","article-title":"Screw configuration in proximal humerus plating has a significant impact on fixation failure risk predicted by finite element models","volume":"28","author":"Fletcher","year":"2019","journal-title":"J Shoulder Elbow Surg"},{"key":"R34-20250503","doi-asserted-by":"crossref","first-page":"1069","DOI":"10.1007\/s00402-019-03175-x","article-title":"The influence of screw length on predicted cut-out failures for proximal humeral fracture fixations predicted by finite element simulations","volume":"139","author":"Fletcher","year":"2019","journal-title":"Arch Orthop Trauma Surg"},{"key":"R35-20250503","doi-asserted-by":"crossref","first-page":"1557","DOI":"10.1016\/j.injury.2014.05.025","article-title":"How many radiographs are needed to detect angular stable head screw cut outs of the proximal humerus: A cadaver study","volume":"45","author":"Spross","year":"2014","journal-title":"Injury"},{"key":"R36-20250503","doi-asserted-by":"crossref","first-page":"474","DOI":"10.1016\/j.injury.2016.12.022","article-title":"The results of tension band rotator cuff suture fixation of locked plating of displaced proximal humerus fractures","volume":"48","author":"Shukla","year":"2017","journal-title":"Injury"},{"key":"R37-20250503","doi-asserted-by":"crossref","first-page":"458","DOI":"10.1097\/BOT.0000000000000051","article-title":"No contribution of tension-reducing rotator cuff sutures on locking plate fixation in a 2-part proximal humerus fracture model","volume":"28","author":"Sinatra","year":"2014","journal-title":"J Orthop Trauma"},{"key":"R38-20250503","doi-asserted-by":"crossref","first-page":"e262","DOI":"10.1097\/BOT.0000000000000575","article-title":"Biomechanical contribution of tension-reducing rotator cuff sutures in 3-part proximal humerus fractures","volume":"30","author":"Arvesen","year":"2016","journal-title":"J Orthop Trauma"},{"key":"R39-20250503","doi-asserted-by":"crossref","first-page":"1075","DOI":"10.1007\/s00402-019-03162-2","article-title":"Augmentation of plate osteosynthesis for proximal humeral fractures: A systematic review of current biomechanical and clinical studies","volume":"139","author":"Biermann","year":"2019","journal-title":"Arch Orthop Trauma Surg"},{"key":"R40-20250503","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1097\/BOT.0000000000001668","article-title":"Mechanical effects of bone substitute and far-cortical locking techniques in 2-Part Proximal humerus fracture reconstruction: A cadaveric study","volume":"34","author":"Hast","year":"2020","journal-title":"J Orthop Trauma"},{"key":"R41-20250503","doi-asserted-by":"crossref","first-page":"1759","DOI":"10.1016\/j.injury.2012.07.003","article-title":"The effect of in situ augmentation on implant anchorage in proximal humeral head fractures","volume":"43","author":"Unger","year":"2012","journal-title":"Injury"},{"key":"R42-20250503","doi-asserted-by":"crossref","first-page":"1968","DOI":"10.1016\/j.jse.2015.06.028","article-title":"Screw augmentation reduces motion at the bone-implant interface: A biomechanical study of locking plate fixation of proximal humeral fractures","volume":"24","author":"Schliemann","year":"2015","journal-title":"J Shoulder Elbow Surg"},{"key":"R43-20250503","doi-asserted-by":"crossref","first-page":"741","DOI":"10.1016\/j.jse.2011.09.017","article-title":"Fracture site augmentation with calcium phosphate cement reduces screw penetration after open reduction-internal fixation of proximal humeral fractures","volume":"21","author":"Egol","year":"2012","journal-title":"J Shoulder Elbow Surg"},{"key":"R44-20250503","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1097\/BOT.0000000000001376","article-title":"Does supplemental intramedullary grafting increase stability of plated proximal humerus fractures?","volume":"33","author":"Rusimov","year":"2019","journal-title":"J Orthop Trauma"},{"key":"R45-20250503","doi-asserted-by":"crossref","first-page":"937","DOI":"10.1302\/0301-620X.93B7.26125","article-title":"The biomechanical performance of locking plate fixation with intramedullary fibular strut graft augmentation in the treatment of unstable fractures of the proximal humerus","volume":"93","author":"Bae","year":"2011","journal-title":"J Bone Joint Surg Br"},{"key":"R46-20250503","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1016\/j.ocl.2018.10.005","article-title":"Surgical considerations in the treatment of osteoporotic proximal humerus fractures","volume":"50","author":"Stone","year":"2019","journal-title":"Orthop Clin North Am"}],"container-title":["Journal of the American Academy of Orthopaedic Surgeons"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-20-00558","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T14:48:36Z","timestamp":1787669316000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-20-00558"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,2,4]]},"references-count":46,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.5435\/jaaos-d-20-00558","relation":{},"ISSN":["1067-151X","1940-5480"],"issn-type":[{"value":"1067-151X","type":"print"},{"value":"1940-5480","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,2,4]]},"assertion":[{"value":"2020-06-04","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-12-24","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}