{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,2]],"date-time":"2026-11-02T22:26:44Z","timestamp":1793658404156,"version":"4.5.1"},"reference-count":44,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"19","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["J Am Acad Orthop Surg","JAAOS"],"published-print":{"date-parts":[[2021,10,1]]},"abstract":"<jats:p>All-suture anchors (ASAs) are a relatively new alternative to traditional suture anchors, comprised of sutures, suture tapes, or ribbons woven through a soft sleeve. These novel anchors are typically smaller than traditional anchors, allowing for more anchors to be used in the same amount of space or for use when bone stock is limited, for example, in revision settings. They can be inserted through curved guides to reach more challenging locations, and they have thus far had similar loads to failure during biomechanical testing as traditional anchors. However, these benefits must be weighed against new challenges. When using ASAs, care must be taken to fully deploy and seat the anchor against cortical bone for optimal fixation and to prevent gap formation. Furthermore, decortication, often performed to enhance the biologic environment for soft-tissue healing, may weaken the cortical bone on which ASA fixation depends on. The purpose of this article is to provide insight on the designs, advantages, and potential disadvantages associated with ASAs, as well as review the available biomechanical and clinical data.<\/jats:p>","DOI":"10.5435\/jaaos-d-20-01224","type":"journal-article","created":{"date-parts":[[2021,9,22]],"date-time":"2021-09-22T09:10:12Z","timestamp":1632301812000},"page":"e950-e960","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":22,"title":["All-Suture Anchors in Orthopaedic Surgery: Design, Rationale, Biomechanical Data, and Clinical Outcomes"],"prefix":"10.5435","volume":"29","author":[{"given":"David P.","family":"Trofa","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3385-5454","authenticated-orcid":false,"given":"Elise C.","family":"Bixby","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James E.","family":"Fleischli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3984-4246","authenticated-orcid":false,"given":"Bryan M.","family":"Saltzman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2021,10,1]]},"reference":[{"key":"R1-20250503","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1016\/j.clinbiomech.2018.11.008","article-title":"The history of suture anchors in orthopaedic surgery","volume":"61","author":"Visscher","year":"2019","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"R2-20250503","doi-asserted-by":"crossref","first-page":"1351","DOI":"10.1016\/j.arthro.2018.12.011","article-title":"Comparison of clinical outcomes and computed tomography analysis for tunnel diameter after arthroscopic Bankart repair with the all-suture anchor and the biodegradable suture anchor","volume":"35","author":"Lee","year":"2019","journal-title":"Arthroscopy"},{"key":"R3-20250503","doi-asserted-by":"crossref","first-page":"81","DOI":"10.4103\/0973-6042.161440","article-title":"Triple labrum tears repaired with the JuggerKnot soft anchor: Technique and results","volume":"9","author":"Agrawal","year":"2015","journal-title":"Int J Shoulder Surg"},{"key":"R4-20250503","doi-asserted-by":"crossref","first-page":"1991","DOI":"10.1016\/j.jse.2019.03.003","article-title":"Arthroscopic glenoid labral lesion repair using all-suture anchor for traumatic anterior shoulder instability: Short-term results","volume":"28","author":"G\u00fcl","year":"2019","journal-title":"J Shoulder Elbow Surg"},{"key":"R5-20250503","first-page":"174","article-title":"Radiological and clinical outcome of arthroscopic labral repair with all-suture anchors","volume":"82","author":"Willemot","year":"2016","journal-title":"Acta Orthop Belg"},{"key":"R6-20250503","doi-asserted-by":"crossref","first-page":"3483","DOI":"10.1177\/0363546519886547","article-title":"All-suture anchor settling after arthroscopic repair of small and medium rotator cuff tears","volume":"47","author":"Ro","year":"2019","journal-title":"Am J Sports Med"},{"key":"R7-20250503","doi-asserted-by":"crossref","first-page":"2284","DOI":"10.1016\/j.arthro.2019.03.032","article-title":"Perianchor cyst formation after arthroscopic rotator cuff repair using all-suture\u2013type, bioabsorbable-type, and PEEK-type anchors","volume":"35","author":"Ro","year":"2019","journal-title":"Arthroscopy"},{"key":"R8-20250503","doi-asserted-by":"crossref","first-page":"2006","DOI":"10.1016\/j.jse.2018.03.006","article-title":"Rotator cuff repair with all-suture anchors: A midterm magnetic resonance imaging evaluation of repair integrity and cyst formation","volume":"27","author":"Van der Bracht","year":"2018","journal-title":"J Shoulder Elbow Surg"},{"key":"R9-20250503","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1016\/j.jcot.2018.02.014","article-title":"Mid-term clinical outcome following rotator cuff repair using all-suture anchors","volume":"10","author":"Dhinsa","year":"2019","journal-title":"J Clin Orthop Trauma"},{"key":"R10-20250503","doi-asserted-by":"crossref","first-page":"4005","DOI":"10.1007\/s00167-019-05663-4","article-title":"Double on-lay fixation using all suture-type anchor for subpectoral biceps tenodesis has favorable functional outcomes and leads to less cosmetic deformities than single on-lay fixation","volume":"27","author":"Rhee","year":"2019","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"R11-20250503","doi-asserted-by":"crossref","first-page":"1523","DOI":"10.1016\/j.arthro.2020.01.046","article-title":"Biomechanical evaluation of knotless and knotted all-suture anchor repair constructs in 4 Bankart repair configurations","volume":"36","author":"Lacheta","year":"2020","journal-title":"Arthroscopy"},{"key":"R12-20250503","doi-asserted-by":"crossref","first-page":"808","DOI":"10.1016\/j.clinbiomech.2015.06.009","article-title":"Biomechanical comparison of traditional anchors to all-suture anchors in a double-row rotator cuff repair cadaver model","volume":"30","author":"Goschka","year":"2015","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"R13-20250503","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1016\/j.jor.2018.01.049","article-title":"Analysis of glenoid inter-anchor distance with an all-suture anchor system","volume":"15","author":"Kramer","year":"2018","journal-title":"J Orthop"},{"key":"R14-20250503","doi-asserted-by":"crossref","first-page":"1113","DOI":"10.1016\/j.arthro.2016.09.031","article-title":"All-suture anchors: Biomechanical analysis of pullout strength, displacement, and failure mode","volume":"33","author":"Barber","year":"2017","journal-title":"Arthroscopy"},{"key":"R15-20250503","doi-asserted-by":"crossref","first-page":"2017","DOI":"10.1007\/s00264-013-1984-4","article-title":"Pullout strength of all suture anchors in the repair of rotator cuff tears: A biomechanical study","volume":"37","author":"Galland","year":"2013","journal-title":"Int Orthop"},{"key":"R16-20250503","doi-asserted-by":"crossref","first-page":"e0225648","DOI":"10.1371\/journal.pone.0225648","article-title":"Conventional rotator cuff versus all-suture anchors-A biomechanical study focusing on the insertion angle in an unlimited cyclic model","volume":"14","author":"Ntalos","year":"2019","journal-title":"PLoS One"},{"key":"R17-20250503","doi-asserted-by":"crossref","first-page":"2433","DOI":"10.1016\/j.jse.2019.04.053","article-title":"Biomechanical analysis of conventional anchor revision after all-suture anchor pullout: A human cadaveric shoulder model","volume":"28","author":"Ntalos","year":"2019","journal-title":"J Shoulder Elbow Surg"},{"key":"R18-20250503","doi-asserted-by":"crossref","first-page":"e52","DOI":"10.1016\/j.jse.2019.07.032","article-title":"Three anchor concepts for rotator cuff repair in standardized physiological and osteoporotic bone: A biomechanical study","volume":"29","author":"Rosso","year":"2020","journal-title":"J Shoulder Elbow Surg"},{"key":"R19-20250503","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1302\/2046-3758.62.BJR-2016-0225.R1","article-title":"Mechanical properties of all-suture anchors for rotator cuff repair","volume":"6","author":"Nagra","year":"2017","journal-title":"Bone Joint Res"},{"key":"R20-20250503","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1177\/1758573218779078","article-title":"Biomechanical testing of trans-humeral all-suture anchors for rotator cuff repair","volume":"11","author":"Aramberri-Guti\u00e9rrez","year":"2019","journal-title":"Shoulder Elbow"},{"key":"R21-20250503","first-page":"1370","article-title":"Biomechanical analysis of all-suture anchor fixation for rotator cuff repair","volume":"35","author":"Bernardoni","year":"2018","journal-title":"Orthop J Sports Med"},{"key":"R22-20250503","doi-asserted-by":"crossref","first-page":"1370","DOI":"10.1016\/j.arthro.2019.01.023","article-title":"Biomechanical analysis of medial-row all-suture suture anchor fixation for rotator cuff repair in a pair-matched cadaveric model","volume":"35","author":"Bernardoni","year":"2019","journal-title":"Arthroscopy"},{"key":"R23-20250503","doi-asserted-by":"crossref","first-page":"930","DOI":"10.1016\/j.arthro.2008.03.010","article-title":"Determination of anterior labral repair stress during passive arm motion in a cadaveric model","volume":"24","author":"Penna","year":"2008","journal-title":"Arthroscopy"},{"key":"R24-20250503","doi-asserted-by":"crossref","first-page":"2325967117717010","DOI":"10.1177\/2325967117717010","article-title":"Biomechanical comparison of a first- and a second-generation all-soft suture glenoid anchor","volume":"5","author":"Erickson","year":"2017","journal-title":"Orthop J Sports Med"},{"key":"R25-20250503","doi-asserted-by":"crossref","first-page":"1156","DOI":"10.1016\/j.jse.2013.12.036","article-title":"The histologic and biomechanical response of two commercially available small glenoid anchors for use in labral repairs","volume":"23","author":"Pfeiffer","year":"2014","journal-title":"J Shoulder Elbow Surg"},{"key":"R26-20250503","doi-asserted-by":"crossref","first-page":"1384","DOI":"10.1016\/j.arthro.2017.11.014","article-title":"Slight reduction in the insertion depth for an all-suture anchor decreases cyclic displacement in the shoulder glenoid","volume":"34","author":"Ruder","year":"2018","journal-title":"Arthroscopy"},{"key":"R27-20250503","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1007\/s00167-013-2760-0","article-title":"Maximum load to failure and tensile displacement of an all-suture glenoid anchor compared with a screw-in glenoid anchor","volume":"24","author":"Dwyer","year":"2016","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"R28-20250503","doi-asserted-by":"crossref","first-page":"1247","DOI":"10.1016\/j.arthro.2016.01.016","article-title":"Biomechanical comparison of all-suture anchor fixation and interference screw technique for subpectoral biceps tenodesis","volume":"32","author":"Chiang","year":"2016","journal-title":"Arthroscopy"},{"key":"R29-20250503","doi-asserted-by":"crossref","first-page":"1755","DOI":"10.1016\/j.arthro.2018.01.007","article-title":"Biomechanical evaluation of a transtendinous all-suture anchor technique versus interference screw technique for suprapectoral biceps tenodesis in a cadaveric model","volume":"34","author":"Hong","year":"2018","journal-title":"Arthroscopy"},{"key":"R30-20250503","doi-asserted-by":"crossref","first-page":"1760","DOI":"10.1016\/j.arthro.2019.01.026","article-title":"Biomechanical analysis of all-suture suture anchor fixation compared with conventional suture anchors and interference screws for biceps tenodesis","volume":"35","author":"Frank","year":"2019","journal-title":"Arthroscopy"},{"key":"R31-20250503","doi-asserted-by":"crossref","first-page":"2325967119876276","DOI":"10.1177\/2325967119876276","article-title":"Biomechanical comparison of subpectoral biceps tenodesis onlay techniques","volume":"7","author":"Lacheta","year":"2019","journal-title":"Orthop J Sports Med"},{"key":"R32-20250503","doi-asserted-by":"crossref","first-page":"e102","DOI":"10.3928\/01477447-20200107-03","article-title":"Open biceps tenodesis: A biomechanical comparison of 6 fixation techniques","volume":"43","author":"Diaz","year":"2020","journal-title":"Orthopedics"},{"key":"R33-20250503","doi-asserted-by":"crossref","first-page":"1019","DOI":"10.1007\/s00167-010-1348-1","article-title":"Biomechanical analysis suggests early rehabilitation is possible after single-incision EndoButton distal biceps repair with FiberWire","volume":"19","author":"Rose","year":"2011","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"R34-20250503","doi-asserted-by":"crossref","first-page":"2478","DOI":"10.1177\/0363546519860489","article-title":"Biomechanical comparison of onlay distal biceps tendon repair: All-suture anchors versus titanium suture anchors","volume":"47","author":"Otto","year":"2019","journal-title":"Am J Sports Med"},{"key":"R35-20250503","doi-asserted-by":"crossref","first-page":"1762","DOI":"10.1177\/0363546511404139","article-title":"Biomechanical in vitro validation of intramedullary cortical button fixation for distal biceps tendon repair: A new technique","volume":"39","author":"Siebenlist","year":"2011","journal-title":"Am J Sports Med"},{"key":"R36-20250503","doi-asserted-by":"crossref","first-page":"2325967119892925","DOI":"10.1177\/2325967119892925","article-title":"Biomechanical evaluation of proximal hamstring repair: All-suture anchor versus titanium suture anchor","volume":"8","author":"Otto","year":"2020","journal-title":"Orthop J Sports Med"},{"key":"R37-20250503","doi-asserted-by":"crossref","first-page":"977","DOI":"10.1016\/j.arthro.2016.11.022","article-title":"Cyclic and load to failure properties of all-suture anchors in synthetic acetabular and glenoid cancellous bone","volume":"33","author":"Douglass","year":"2017","journal-title":"Arthroscopy"},{"key":"R38-20250503","doi-asserted-by":"crossref","first-page":"1213","DOI":"10.1016\/j.arthro.2017.09.049","article-title":"Acetabular all-suture anchor for labral repair: Incidence of intraoperative failure due to pullout","volume":"34","author":"Byrd","year":"2018","journal-title":"Arthroscopy"},{"key":"R39-20250503","doi-asserted-by":"crossref","first-page":"2777","DOI":"10.1016\/j.arthro.2018.05.030","article-title":"Greater tuberosity decortication decreases load to failure of all-suture anchor constructs in rotator cuff repair","volume":"34","author":"Ruder","year":"2018","journal-title":"Arthroscopy"},{"key":"R40-20250503","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1016\/j.clinbiomech.2018.10.002","article-title":"Biomechanical effects of position and angle of insertion for all-suture anchors in arthroscopic Bankart repair","volume":"60","author":"Lee","year":"2018","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"R41-20250503","doi-asserted-by":"crossref","first-page":"2784","DOI":"10.1016\/j.arthro.2018.04.028","article-title":"Pullout strength of all-suture anchors: Effect of the insertion and traction angle-A biomechanical study","volume":"34","author":"Oh","year":"2018","journal-title":"Arthroscopy"},{"key":"R42-20250503","doi-asserted-by":"crossref","first-page":"1506","DOI":"10.1302\/0301-620X.101B12.BJJ-2019-0462.R2","article-title":"The formation of perianchor fluid associated with various suture anchors used in rotator cuff repair: All-suture, polyetheretherketone, and biocomposite anchors","volume":"101-B","author":"Kim","year":"2019","journal-title":"Bone Joint J"},{"key":"R43-20250503","doi-asserted-by":"crossref","first-page":"2840","DOI":"10.1177\/0363546517714476","article-title":"Postoperative recurrence of instability due to new anterior glenoid rim fractures after arthroscopic Bankart repair","volume":"45","author":"Nakagawa","year":"2017","journal-title":"Am J Sports Med"},{"key":"R44-20250503","doi-asserted-by":"crossref","first-page":"1479","DOI":"10.1016\/j.jse.2019.12.007","article-title":"Pullout strength and failure mode of industrially manufactured and self-made all-suture anchors: A biomechanical analysis","volume":"29","author":"Godry","year":"2020","journal-title":"J Shoulder Elbow Surg"}],"container-title":["Journal of the American Academy of Orthopaedic Surgeons"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-20-01224","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T14:46:24Z","timestamp":1787669184000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-20-01224"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,10,1]]},"references-count":44,"journal-issue":{"issue":"19","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.5435\/jaaos-d-20-01224","relation":{},"ISSN":["1067-151X","1940-5480"],"issn-type":[{"value":"1067-151X","type":"print"},{"value":"1940-5480","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,10,1]]},"assertion":[{"value":"2020-11-08","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-05-11","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}