{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T15:57:25Z","timestamp":1787759845912,"version":"build-2784847793"},"reference-count":19,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["J Am Acad Orthop Surg","JAAOS"],"published-print":{"date-parts":[[2022,5,15]]},"abstract":"<jats:sec>\n                    <jats:title>Introduction:<\/jats:title>\n                    <jats:p>The purpose of this study was to arthroscopically evaluate syndesmotic stability after fixation with several combinations of suture buttons (SBs) and suture tape reinforcement in a completely unstable cadaver model.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Fifteen cadaver above-knee specimens underwent sequential ligament transection and fixation to create six experimental models: (1) intact model, (2) after complete disruption of the syndesmotic ligaments, and after repair with either suture tape reinforcement (3), suture tape reinforcement with a single SB (4), suture tape reinforcement with two diverging SBs (5), or two diverging SBs alone (6). Instability measurements included anterior and posterior tibiofibular spaces measured arthroscopically under 100 N coronal stress, tibiofibular anteroposterior and posteroanterior translation in sagittal plane measured arthroscopically under sagittal stress of 100 N, and anterior tibiofibular space measured directly with a caliper under external rotation torque of 7.5 N\u00b7m. Instability measurements taken after each fixation method were compared with the uninjured model and with the complete unstable model using the Wilcoxon signed-rank test.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Fixation using a combination of one SB and singular suture tape reinforcement augmentation provided stability similar to the intact stage (coronal anterior space 1.24 versus 1.15,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.887; coronal posterior space 1.63 versus 1.64,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.8421; anteroposterior translation 0.91 versus 0.46,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.003; posteroanterior translation 0.51 versus 0.57,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.051; external rotation anterior tibiofibular space 1.08 versus 0.55,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.069). Moreover, adding a second SB led to further gains in fixation stability.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Discussion:<\/jats:title>\n                    <jats:p>This study suggests that although a destabilizing syndesmotic injury that includes the anterior inferior tibiofibular ligament, interosseous ligament, and posterior inferior tibiofibular ligament is not adequately stabilized by either one or two SBs, the addition of a suture tape reinforcement to even one SB restores syndesmotic stability to the preinjury level.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.5435\/jaaos-d-21-00508","type":"journal-article","created":{"date-parts":[[2022,2,16]],"date-time":"2022-02-16T13:07:32Z","timestamp":1645016852000},"page":"e769-e778","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":13,"title":["Comparison of Several Combinations of Suture Tape Reinforcement and Suture Button Constructs for Fixation of Unstable Syndesmosis"],"prefix":"10.5435","volume":"30","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9271-6932","authenticated-orcid":false,"given":"Haggai","family":"Schermann","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takahisa","family":"Ogawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bart","family":"Lubberts","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"William R.","family":"Taylor","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gregory R.","family":"Waryasz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amal","family":"Khoury","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher W.","family":"DiGiovanni","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Guss","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,2,15]]},"reference":[{"key":"R1-20260212","doi-asserted-by":"crossref","first-page":"2","DOI":"10.2106\/JBJS.16.01011","article-title":"Randomized trial comparing suture button with single syndesmotic screw for syndesmosis injury","volume":"100","author":"Andersen","year":"2018","journal-title":"J Bone Joint Surg Am"},{"key":"R2-20260212","first-page":"32","article-title":"Ebeling, PB: Treatment of syndesmoses disruptions: A prospective, randomized study comparing conventional screw fixation vs TightRope fiber wire fixation\u2013medium term results","volume":"8","author":"Coetzee","year":"2009","journal-title":"SA Orthop J"},{"key":"R3-20260212","doi-asserted-by":"crossref","first-page":"1119","DOI":"10.1016\/j.injury.2015.02.004","article-title":"A prospective randomised study comparing TightRope and syndesmotic screw fixation for accuracy and maintenance of syndesmotic reduction assessed with bilateral computed tomography","volume":"46","author":"Kortekangas","year":"2015","journal-title":"Injury"},{"key":"R4-20260212","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1097\/BOT.0000000000000245","article-title":"A prospective randomized multicenter trial comparing clinical outcomes of patients treated surgically with a static or dynamic implant for acute ankle syndesmosis rupture","volume":"29","author":"Laflamme","year":"2015","journal-title":"J Orthop Trauma"},{"key":"R5-20260212","doi-asserted-by":"crossref","first-page":"3156","DOI":"10.1007\/s00167-017-4820-3","article-title":"Lower complication rate and faster return to sports in patients with acute syndesmotic rupture treated with a new knotless suture button device","volume":"26","author":"Colcuc","year":"2018","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"R6-20260212","doi-asserted-by":"crossref","first-page":"1245","DOI":"10.1053\/j.jfas.2019.01.015","article-title":"Clinical evidence for treatment of distal tibiofibular syndesmosis injury: A systematic review of clinical studies","volume":"58","author":"Liu","year":"2019","journal-title":"J Foot Ankle Surg"},{"key":"R7-20260212","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1302\/0301-620X.102B2.BJJ-2019-0692.R2","article-title":"Better outcome for suture button compared with single syndesmotic screw for syndesmosis injury: Five-year results of a randomized controlled trial","volume":"102-B","author":"R\u00e6der","year":"2020","journal-title":"Bone Joint J"},{"key":"R8-20260212","doi-asserted-by":"crossref","first-page":"1345","DOI":"10.1177\/1071100718786500","article-title":"Biomechanical comparison of syndesmotic repair techniques during external rotation stress","volume":"39","author":"Goetz","year":"2018","journal-title":"Foot Ankle Int"},{"key":"R9-20260212","doi-asserted-by":"crossref","first-page":"463","DOI":"10.1177\/1071100719898181","article-title":"Kinematic analysis of combined suture-button and suture anchor augment constructs for ankle syndesmosis injuries","volume":"41","author":"Wood","year":"2020","journal-title":"Foot Ankle Int"},{"key":"R10-20260212","doi-asserted-by":"crossref","first-page":"2325967118804204","DOI":"10.1177\/2325967118804204","article-title":"Biomechanical comparison of 3 syndesmosis repair techniques with suture button implants","volume":"6","author":"Parker","year":"2018","journal-title":"Orthop J Sports Med"},{"key":"R11-20260212","doi-asserted-by":"crossref","first-page":"301","DOI":"10.5312\/wjo.v8.i4.301","article-title":"Syndesmotic Internal Brace for anatomic distal tibiofibular ligament augmentation","volume":"8","author":"Regauer","year":"2017","journal-title":"World J Orthop"},{"key":"R12-20260212","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1053\/j.jfas.2017.07.007","article-title":"Suture-button fixation and mini-open anterior inferior tibiofibular ligament augmentation using suture tape for tibiofibular syndesmosis injuries","volume":"57","author":"Teramoto","year":"2018","journal-title":"J Foot Ankle Surg"},{"key":"R13-20260212","doi-asserted-by":"crossref","first-page":"745","DOI":"10.1016\/j.csm.2020.06.002","article-title":"Acute and chronic syndesmotic instability: Role of surgical stabilization","volume":"39","author":"Stenquist","year":"2020","journal-title":"Clin Sports Med"},{"key":"R14-20260212","doi-asserted-by":"crossref","first-page":"1387","DOI":"10.1177\/1071100717729492","article-title":"Effect of sequential sectioning of ligaments on syndesmotic instability in the coronal plane evaluated arthroscopically","volume":"38","author":"Massri-Pugin","year":"2017","journal-title":"Foot Ankle Int"},{"key":"R15-20260212","doi-asserted-by":"crossref","first-page":"558","DOI":"10.1016\/S0749-8063(05)80014-3","article-title":"Disruption of the ankle syndesmosis: Biomechanical study of the ligamentous restraints","volume":"10","author":"Ogilvie-Harris","year":"1994","journal-title":"Arthroscopy"},{"key":"R16-20260212","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","article-title":"A guideline of selecting and reporting intraclass correlation coefficients for reliability research","volume":"15","author":"Koo","year":"2016","journal-title":"J Chiropr Med"},{"key":"R17-20260212","first-page":"65","article-title":"A simple sequentially rejective multiple test procedure A simple sequentially rejective multiple test procedure","volume":"6","author":"Holm","year":"1979","journal-title":"Source Scand J Stat"},{"key":"R18-20260212","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1007\/s00167-018-5229-3","article-title":"The arthroscopic syndesmotic assessment tool can differentiate between stable and unstable ankle syndesmoses","volume":"28","author":"Lubberts","year":"2020","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"R20-20260212","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1016\/j.clinbiomech.2018.10.014","article-title":"Suture-button fixation and anterior inferior tibiofibular ligament augmentation with suture-tape for syndesmosis injury: A biomechanical cadaveric study","volume":"60","author":"Shoji","year":"2018","journal-title":"Clin Biomech (Bristol, Avon)"}],"container-title":["Journal of the American Academy of Orthopaedic Surgeons"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-21-00508","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T14:41:24Z","timestamp":1787668884000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-21-00508"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,2,15]]},"references-count":19,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.5435\/jaaos-d-21-00508","relation":{},"ISSN":["1067-151X","1940-5480"],"issn-type":[{"value":"1067-151X","type":"print"},{"value":"1940-5480","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,2,15]]},"assertion":[{"value":"2021-04-22","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-11-08","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}