{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,10]],"date-time":"2026-11-10T13:24:32Z","timestamp":1794317072086,"version":"4.9.0"},"reference-count":25,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"13","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["J Am Acad Orthop Surg","JAAOS"],"published-print":{"date-parts":[[2022,7,1]]},"abstract":"<jats:sec>\n                    <jats:title>Objectives:<\/jats:title>\n                    <jats:p>This biomechanical study seeks to define the relative effectiveness of contemporary single and dual implant constructs for fixation of an extra-articular proximal tibia fracture model.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>An extra-articular proximal tibia fracture model was created using synthetic tibias. Four constructs were tested. Constructs included (1) lateral locked plate (LLP), (2) intramedullary nail (IMN), (3) combined LLP and IMN (PN), and (4) LLP and medial locked plate. Specimens were axially loaded through the medial plateau to evaluate construct stiffness and the ability to resist varus collapse.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Dual implant constructs were stiffer than single implant constructs in this model. Although DP and PN were stiffer than IMN at all loads tested, the difference was notable only for DP at higher loads. Isolated LLP provided insufficient stability to be tested at higher loads.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Dual plate fixation provides the greatest resistance to varus collapse. In the clinical setting, consideration must be given to the fracture morphology, desired construct stiffness, and soft-tissue envelope in selecting the optimal construct to be used.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.5435\/jaaos-d-21-01089","type":"journal-article","created":{"date-parts":[[2022,4,20]],"date-time":"2022-04-20T16:06:12Z","timestamp":1650470772000},"page":"629-635","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":6,"title":["Fixation of Extra-articular Proximal Tibia Fractures: Biomechanical Comparison of Single and Dual Implant Constructs"],"prefix":"10.5435","volume":"30","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7926-5017","authenticated-orcid":false,"given":"John A.","family":"Scolaro","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David J.","family":"Wright","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wilson","family":"Lai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Genevieve","family":"Fraipont","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hunter","family":"Hitchens","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Kwak","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michelle","family":"McGarry","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thay Q.","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,4,19]]},"reference":[{"issue":"suppl 1","key":"R1-20250503","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1097\/BOT.0000000000001063","article-title":"Fracture and dislocation classification compendium-2018","volume":"32","author":"Meinberg","year":"2018","journal-title":"J Orthop Trauma"},{"key":"R2-20250503","doi-asserted-by":"crossref","first-page":"540","DOI":"10.1097\/00005131-200409000-00010","article-title":"Unstable proximal extraarticular tibia fractures: A biomechanical evaluation of four methods of fixation","volume":"18","author":"Peindl","year":"2004","journal-title":"J Orthop Trauma"},{"key":"R3-20250503","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1097\/QAI.0b013e3181a25368","article-title":"Biomechanical comparison of polyaxial and uniaxial locking plate fixation in a proximal tibial gap model","volume":"23","author":"Cullen","year":"2009","journal-title":"J Orthop Trauma"},{"key":"R4-20250503","doi-asserted-by":"crossref","first-page":"312","DOI":"10.4055\/cios.2014.6.3.312","article-title":"Biomechanical analysis of operative methods in the treatment of extra-articular fracture of the proximal tibia","volume":"6","author":"Lee","year":"2014","journal-title":"Clin Orthop Surg"},{"key":"R5-20250503","doi-asserted-by":"crossref","first-page":"426","DOI":"10.1302\/0301-620X.87B3.14353","article-title":"Primary stability of various forms of osteosynthesis in the treatment of fractures of the proximal tibia","volume":"87","author":"Mueller","year":"2005","journal-title":"J Bone Joint Surg Br"},{"key":"R6-20250503","doi-asserted-by":"crossref","first-page":"176","DOI":"10.5435\/00124635-200105000-00004","article-title":"Nonarticular proximal tibia fractures: Treatment options and decision making","volume":"9","author":"Bono","year":"2001","journal-title":"J Am Acad Orthop Surg"},{"key":"R7-20250503","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/j.ocl.2013.09.001","article-title":"Techniques for intramedullary nailing of proximal tibia fractures","volume":"45","author":"Stinner","year":"2014","journal-title":"Orthop Clin North Am"},{"key":"R8-20250503","doi-asserted-by":"crossref","first-page":"66","DOI":"10.5435\/JAAOS-D-18-00765","article-title":"Pearls and pitfalls with intramedullary nailing of proximal tibia fractures","volume":"28","author":"Lee","year":"2020","journal-title":"J Am Acad Orthop Surg"},{"issue":"suppl 1","key":"R9-20250503","doi-asserted-by":"crossref","first-page":"S25","DOI":"10.1097\/BOT.0000000000001094","article-title":"Endosteal substitution with an intramedullary rod in fractures of the femur","volume":"32","author":"Spitler","year":"2018","journal-title":"J Orthop Trauma"},{"issue":"suppl 6","key":"R10-20250503","doi-asserted-by":"crossref","first-page":"S18","DOI":"10.1097\/BOT.0000000000001571","article-title":"Nail and plate combination fixation for periprosthetic and interprosthetic fractures","volume":"33","author":"Yoon","year":"2019","journal-title":"J Orthop Trauma"},{"key":"R11-20250503","doi-asserted-by":"crossref","first-page":"642","DOI":"10.1097\/BOT.0000000000001591","article-title":"Supplementation of lateral locked plating for distal femur fractures: A biomechanical study","volume":"33","author":"Fontenot","year":"2019","journal-title":"J Orthop Trauma"},{"key":"R12-20250503","doi-asserted-by":"crossref","first-page":"434","DOI":"10.1097\/BOT.0000000000001749","article-title":"Supplemental fixation of supracondylar distal femur fractures: A biomechanical comparison of dual-plate and plate-nail constructs","volume":"34","author":"Wright","year":"2020","journal-title":"J Orthop Trauma"},{"key":"R13-20250503","doi-asserted-by":"crossref","first-page":"701","DOI":"10.1097\/BOT.0b013e31815aba5e","article-title":"Intramedullary stabilization of extraarticular proximal tibial fractures: A biomechanical comparison of intramedullary and extramedullary implants including a new proximal tibia nail (PTN)","volume":"21","author":"Hansen","year":"2007","journal-title":"J Orthop Trauma"},{"key":"R14-20250503","doi-asserted-by":"crossref","first-page":"485","DOI":"10.1097\/BOT.0b013e3181b013d2","article-title":"Intramedullary nailing versus percutaneous locked plating of extra-articular proximal tibial fractures: Comparison of 56 cases","volume":"23","author":"Lindvall","year":"2009","journal-title":"J Orthop Trauma"},{"key":"R15-20250503","doi-asserted-by":"crossref","first-page":"722","DOI":"10.1016\/j.jss.2012.04.014","article-title":"Biomechanical evaluation of various fixation methods for proximal extra-articular tibial fractures","volume":"178","author":"Feng","year":"2012","journal-title":"J Surg Res"},{"key":"R16-20250503","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1007\/s10195-014-0332-9","article-title":"Intramedullary nailing versus proximal plating in the management of closed extra-articular proximal tibial fracture: A randomized controlled trial","volume":"16","author":"Meena","year":"2015","journal-title":"J Orthop Traumatol"},{"key":"R17-20250503","doi-asserted-by":"crossref","first-page":"e49","DOI":"10.1097\/BOT.0000000000000729","article-title":"Fatigue failure in extra-articular proximal tibia fractures: Locking intramedullary nail versus double locking plates-A biomechanical study","volume":"31","author":"Kandemir","year":"2017","journal-title":"J Orthop Trauma"},{"key":"R18-20250503","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1007\/s00402-011-1380-8","article-title":"Angle stable locking nails versus conventionally locked intramedullary nails in proximal tibial shaft fractures: A biomechanical study","volume":"132","author":"Thelen","year":"2012","journal-title":"Arch Orthop Trauma Surg"},{"key":"R19-20250503","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1097\/BOT.0b013e3181f982e5","article-title":"Biomechanical comparison of tibial nail stability in a proximal third fracture: Do screw quantity and locked, interlocking screws make a difference?","volume":"25","author":"Freeman","year":"2011","journal-title":"J Orthop Trauma"},{"key":"R20-20250503","doi-asserted-by":"crossref","first-page":"e64","DOI":"10.1097\/BOT.0000000000001332","article-title":"Nail plate combination technique for native and periprosthetic distal femur fractures","volume":"33","author":"Liporace","year":"2019","journal-title":"J Orthop Trauma"},{"key":"R21-20250503","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1007\/s00590-021-02994-2","article-title":"Nail plate combination in the upper extremity: Surgical technique and clinical application","volume":"2","author":"Ganta","year":"2022","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"R22-20250503","doi-asserted-by":"crossref","first-page":"560","DOI":"10.1097\/BOT.0b013e318185fa7e","article-title":"Operative treatment of ipsilateral noncontiguous unicondylar tibial plateau and shaft fractures: Combining plates and nails","volume":"22","author":"Kubiak","year":"2008","journal-title":"J Orthop Trauma"},{"key":"R23-20250503","doi-asserted-by":"crossref","first-page":"S17","DOI":"10.1097\/BOT.0000000000000698","article-title":"Intramedullary nail and plate combination fixation for complex distal tibia fractures: When and how?","volume":"30","author":"Yoon","year":"2016","journal-title":"J Orthop Trauma"},{"key":"R24-20250503","doi-asserted-by":"crossref","DOI":"10.1016\/j.injury.2021.07.010","article-title":"Combined plate and nail fixation of bicondylar tibial plateau fractures","author":"Wright","year":"2021","journal-title":"Injury"},{"key":"R25-20250503","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1302\/0301-620X.84B8.0841093","article-title":"Evolution of the internal fixation of long bone fractures","volume":"84","author":"Perren","year":"2002","journal-title":"J Bone Joint Surg Br"}],"container-title":["Journal of the American Academy of Orthopaedic Surgeons"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-21-01089","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T14:47:54Z","timestamp":1787669274000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-21-01089"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,4,19]]},"references-count":25,"journal-issue":{"issue":"13","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.5435\/jaaos-d-21-01089","relation":{},"ISSN":["1067-151X","1940-5480"],"issn-type":[{"value":"1067-151X","type":"print"},{"value":"1940-5480","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,4,19]]},"assertion":[{"value":"2021-10-29","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-03-17","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}