{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T15:29:19Z","timestamp":1787671759785,"version":"build-2736575974"},"reference-count":17,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["J Am Acad Orthop Surg","JAAOS"],"published-print":{"date-parts":[[2025,2,1]]},"abstract":"<jats:sec>\n                    <jats:title>Introduction:<\/jats:title>\n                    <jats:p>Symptomatic interlocking screws are common after intramedullary nail fixation of tibia fractures. Low-profile headless interlocking screws recently became available and could potentially reduce the rate of symptomatic screws. The purpose of this study was to compare the rate of symptomatic screws and screw removals between these screw types.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>A retrospective review identified patients with tibia shaft fractures treated with tibia intramedullary nails between August 1, 2018 to September 1, 2023 by 11 surgeons. Low-profile headless interlocking screws became available on June 28, 2021 and were routinely used thereafter. Patients treated with low-profile headless versus standard headed interlocking screws were compared in terms of symptomatic screws, defined as a patient reporting pain or discomfort at the site of a screw head in clinical documentation, symptomatic screw removals, screw failure (breakage or backout), and procedures to promote bone union.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Overall, 79 patients were included in the analysis: 33 patients treated with 144 headless screws and 46 patients treated with 187 standard screws. The median patient age was 35 years, and a majority were male (68.4%, n = 54). The median follow-up length was 8.5 months (interquartile range 5.5 to 8.8 months). The headless screw group, compared with standard screw group, did not differ in age, injury mechanism severity, open fracture classification, tobacco use, American Society of Anesthesiologists classification &gt;2, number of interlocking screws used, or follow-up time (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &gt; 0.05). The headless screw group was less likely to have symptomatic screws (0.0% vs. 23.9%;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.002), less likely to have symptomatic screw removal (0.0% vs. 13.0%;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.03), and had no difference in procedures to promote bone union (10.0% vs. 6.8%;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.68) or screw backout (0.0% vs. 4.4%;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.50).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Discussion:<\/jats:title>\n                    <jats:p>Standard headed interlocking screws were symptomatic in 23.9% of patients and 13.0% underwent symptomatic screw removal. In comparison, no patients treated with low-profile headless interlocking screws had symptomatic screws.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Level of Evidence:<\/jats:title>\n                    <jats:p>Level 3, diagnostic<\/jats:p>\n                  <\/jats:sec>","DOI":"10.5435\/jaaos-d-24-00703","type":"journal-article","created":{"date-parts":[[2024,11,27]],"date-time":"2024-11-27T16:01:13Z","timestamp":1732723273000},"page":"145-149","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["A Retrospective Comparison of Headless Versus Standard Interlocking Screw Fixation of Tibia Intramedullary Nails"],"prefix":"10.5435","volume":"33","author":[{"given":"Benjamin D.","family":"Pesante","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Byron A.","family":"Ward","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephen C.","family":"Stacey","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8262-4065","authenticated-orcid":false,"given":"Joshua A.","family":"Parry","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,11,19]]},"reference":[{"key":"R1-20250205","first-page":"263","article-title":"Hardware removal after tibial fracture has healed","volume":"51","author":"Sidky","year":"2008","journal-title":"Can J Surg"},{"key":"R2-20250205","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1097\/BOT.0b013e31816ed974","article-title":"Radiographic and clinical comparisons of distal tibia shaft fractures (4 to 11 cm proximal to the plafond): Plating versus intramedullary nailing","volume":"22","author":"Vallier","year":"2008","journal-title":"J Orthop Trauma"},{"key":"R3-20250205","first-page":"33","article-title":"Single or double distal locking in intramedullary nailing of tibial shaft fractures: A prospective randomized study","volume":"16","author":"Hapa","year":"2010","journal-title":"Ulus Travma Acil Cerrahi Derg"},{"key":"R4-20250205","doi-asserted-by":"crossref","first-page":"779","DOI":"10.1016\/j.injury.2011.09.002","article-title":"Injury to the infrapatellar branch of the saphenous nerve, a possible cause for anterior knee pain after tibial nailing?","volume":"43","author":"Leliveld","year":"2012","journal-title":"Injury"},{"key":"R5-20250205","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1097\/00005131-200605000-00004","article-title":"Does open reduction increase the chance of infection during intramedullary nailing of closed tibial shaft fractures?","volume":"20","author":"Tang","year":"2006","journal-title":"J Orthop Trauma"},{"key":"R6-20250205","doi-asserted-by":"crossref","first-page":"2067","DOI":"10.2106\/JBJS.H.00661","article-title":"Is after-hours orthopaedic surgery associated with adverse outcomes? A prospective comparative study","volume":"91","author":"Ricci","year":"2009","journal-title":"J Bone Joint Surg Am"},{"key":"R7-20250205","doi-asserted-by":"crossref","first-page":"773","DOI":"10.1007\/s00402-008-0678-7","article-title":"Anterior knee pain following the lateral parapatellar approach for tibial nailing","volume":"129","author":"Weil","year":"2009","journal-title":"Arch Orthop Trauma Surg"},{"key":"R8-20250205","doi-asserted-by":"crossref","first-page":"418","DOI":"10.2174\/1874325001509010418","article-title":"High rates of postoperative wound infection following elective implant removal","volume":"9","author":"Backes","year":"2015","journal-title":"Open Orthop J"},{"key":"R9-20250205","doi-asserted-by":"crossref","first-page":"2438","DOI":"10.1001\/jama.2017.19343","article-title":"Effect of antibiotic prophylaxis on surgical site infections following removal of orthopedic implants used for treatment of foot, ankle, and lower leg fractures: A randomized clinical trial","volume":"318","author":"Backes","year":"2017","journal-title":"JAMA"},{"key":"R10-20250205","doi-asserted-by":"crossref","first-page":"1316","DOI":"10.2106\/JBJS.J.01756","article-title":"The benefits of implant removal from the foot and ankle","volume":"94","author":"Williams","year":"2012","journal-title":"J Bone Joint Surg Am"},{"key":"R11-20250205","first-page":"1","article-title":"Hardware related pain and hardware removal after open reduction and internal fixation of ankle fractures","volume":"4","author":"Pot","year":"2011","journal-title":"Foot Ankle Online J"},{"key":"R12-20250205","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1016\/j.foot.2011.11.010","article-title":"Metalwork removal in elective foot and ankle practice: Does it make any difference to the patient?","volume":"22","author":"Wadia","year":"2012","journal-title":"Foot (Edinb)"},{"key":"R13-20250205","doi-asserted-by":"crossref","first-page":"420","DOI":"10.1177\/1938640017744640","article-title":"A comparison of removal rates of headless screws versus headed screws in calcaneal osteotomy","volume":"11","author":"Kunzler","year":"2018","journal-title":"Foot Ankle Spec"},{"key":"R14-20250205","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s00590-020-02843-8","article-title":"Standardizing statistics and data reporting in orthopaedic research","volume":"31","author":"Strage","year":"2021","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"R15-20250205","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1016\/j.fas.2011.03.013","article-title":"Headless compression screw fixation prevents symptomatic metalwork in arthroscopic ankle arthrodesis","volume":"18","author":"Odutola","year":"2012","journal-title":"Foot Ankle Surg"},{"key":"R16-20250205","doi-asserted-by":"crossref","first-page":"e103","DOI":"10.1097\/BOT.0000000000001920","article-title":"Predictors of improved early clinical outcomes after elective implant removal","volume":"35","author":"Kempton","year":"2021","journal-title":"J Orthop Trauma"},{"key":"R17-20250205","doi-asserted-by":"crossref","first-page":"2473011420977864","DOI":"10.1177\/2473011420977864","article-title":"Cost of headless vs headed screw fixation for calcaneal osteotomy and subtalar arthrodesis","volume":"6","author":"Boren","year":"2021","journal-title":"Foot Ankle Orthop"}],"container-title":["Journal of the American Academy of Orthopaedic Surgeons"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-24-00703","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T14:50:21Z","timestamp":1787669421000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-24-00703"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11,19]]},"references-count":17,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.5435\/jaaos-d-24-00703","relation":{},"ISSN":["1067-151X","1940-5480"],"issn-type":[{"value":"1067-151X","type":"print"},{"value":"1940-5480","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,11,19]]},"assertion":[{"value":"2024-06-25","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-09-19","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}