{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T15:28:38Z","timestamp":1787671718368,"version":"build-2736575974"},"reference-count":31,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"24","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["J Am Acad Orthop Surg","JAAOS"],"published-print":{"date-parts":[[2025,12,15]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Bone mineral density is often considered in preoperative surgical planning for spinal fusions. CT imaging\u2013based measurement of Hounsfield units (HU) has been suggested as a surrogate marker for dual-energy x-ray absorptiometry scans. However, research establishing a threshold for HU at the uppermost instrumented vertebrae (UIV) that can mitigate the risk of mechanical and junctional complications following posterior spinal fusion is limited.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Adults who underwent posterior spinal fusion and had 1-year follow-up data available were included in this retrospective cohort study. HU measurements were collected at various vertebral levels, including at the UIV. Inter- and intrarater reliability were calculated using the using intraclass correlation coefficients (ICCs). HU thresholds for mechanical and junctional complications were established using receiver operating characteristic (ROC) curve analyses, while accounting for age, sex, UIV level, and osteoporosis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Across 70 patients, mean age was 64.4 years, 65.3% were female, and 10.0% had osteoporosis. The intrarater reliability ICCs were classified as excellent (ie, greater than 0.9) for all vertebral levels, whereas the interrater reliability ICCs were classified as good (ie, greater than 0.8) for all vertebral levels. ROC curve analyses identified a HU cutoff of 105. Patients below the HU threshold had markedly higher rates of mechanical and junctional complications (52.0% vs. 8.9%,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001), specifically adjacent segment disease (32.0% vs. 2.2%,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>CT-based measurement of HU at the upper instrumented vertebra has excellent intrarater and good interrater reliability. In this cohort of lumbar and thoracolumbar spinal fusion patients, patients with HU under 105 at the UIV had an increased risk of mechanical and junctional complications following spinal fusions. Future studies may work to refine HU assessment and the association with postoperative complications, as using HU to guide surgical candidacy and UIV selection may be beneficial.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.5435\/jaaos-d-24-01435","type":"journal-article","created":{"date-parts":[[2025,4,22]],"date-time":"2025-04-22T18:00:13Z","timestamp":1745344813000},"page":"e1505-e1513","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Upper Instrumented Vertebra Hounsfield Unit Assessment and Association With Mechanical Complications Following Posterior Spinal Fusion"],"prefix":"10.5435","volume":"33","author":[{"given":"Manjot","family":"Singh","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joseph E.","family":"Nassar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael J.","family":"Farias","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brian","family":"McCrae","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ashley","family":"Knebel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bassel G.","family":"Diebo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9597-4139","authenticated-orcid":false,"given":"Alan H.","family":"Daniels","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,4,18]]},"reference":[{"issue":"2","key":"R29-20251205","doi-asserted-by":"crossref","DOI":"10.2106\/JBJS.RVW.24.00210","article-title":"Preoperative Optimization Strategies in Elective Spine Surgery","volume":"13","author":"Daniels","year":"2025","journal-title":"JBJS Rev"},{"key":"R31-20251205","doi-asserted-by":"crossref","DOI":"10.1016\/j.spinee.2025.01.015","article-title":"Revision surgery rates following transforaminal lumbar interbody fusion in patients with and without osteoporosis","author":"Knebel","year":"2025","journal-title":"Spine J"},{"key":"R1-20251205","doi-asserted-by":"crossref","first-page":"436","DOI":"10.3171\/2022.11.SPINE22875","article-title":"Alternatives to DEXA for the assessment of bone density: A systematic review of the literature and future recommendations","volume":"38","author":"Deshpande","year":"2023","journal-title":"J Neurosurg Spine"},{"issue":"23","key":"R30-20251205","doi-asserted-by":"crossref","DOI":"10.3390\/jcm13237173","article-title":"Surgical Management of Adult Spinal Deformity Patients with Osteoporosis.","volume":"13","author":"Baroudi","year":"2024","journal-title":"J Clin Med"},{"key":"R2-20251205","doi-asserted-by":"crossref","first-page":"430","DOI":"10.1007\/s002239900258","article-title":"Impact of spinal degenerative changes on the evaluation of bone mineral density with dual energy X-ray absorptiometry (DXA)","volume":"60","author":"Rand","year":"1997","journal-title":"Calcif Tissue Int"},{"key":"R3-20251205","doi-asserted-by":"crossref","first-page":"1614","DOI":"10.1097\/01.brs.0000222030.32171.5f","article-title":"Discordantly high spinal bone mineral density values in patients with adult lumbar scoliosis","volume":"31","author":"Pappou","year":"2006","journal-title":"Spine (Phila Pa 1976)"},{"key":"R4-20251205","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1515\/med-2019-0061","article-title":"Hounsfield units on lumbar computed tomography for predicting regional bone mineral density","volume":"14","author":"Kim","year":"2019","journal-title":"Open Med (Wars)"},{"key":"R5-20251205","doi-asserted-by":"crossref","first-page":"84","DOI":"10.3171\/2023.8.SPINE23450","article-title":"Evaluating alternatives to dual-energy x-ray absorptiometry for assessing bone quality in patients undergoing spine surgery","volume":"40","author":"Courtois","year":"2024","journal-title":"J Neurosurg Spine"},{"key":"R6-20251205","doi-asserted-by":"crossref","first-page":"1427","DOI":"10.1016\/j.spinee.2023.05.015","article-title":"What is the role of CT-based Hounsfield unit assessment in the evaluation of bone mineral density in patients undergoing 1- or 2-level lumbar spinal fusion for degenerative spinal pathologies? A prospective study","volume":"23","author":"Viswanathan","year":"2023","journal-title":"Spine J"},{"key":"R7-20251205","first-page":"100130","article-title":"CT based bone mineral density as a predictor of proximal junctional fractures","volume":"11","author":"Kurra","year":"2022","journal-title":"N Am Spine Soc J"},{"key":"R8-20251205","doi-asserted-by":"crossref","first-page":"552719","DOI":"10.3389\/fendo.2020.552719","article-title":"Opportunistic osteoporosis screening reveals low bone density in patients with screw loosening after lumbar semi-rigid instrumentation: A case-control study","volume":"11","author":"L\u00f6ffler","year":"2020","journal-title":"Front Endocrinol"},{"key":"R9-20251205","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1186\/s13244-023-01400-1","article-title":"Opportunistic screening for osteoporosis by abdominal CT in a British population","volume":"14","author":"Vadera","year":"2023","journal-title":"Insights Imaging"},{"key":"R10-20251205","doi-asserted-by":"crossref","first-page":"5869","DOI":"10.2147\/IJGM.S368718","article-title":"Reliability of Hounsfield unit for assessing asymmetrical vertebral bone mass in adult degenerative scoliosis","volume":"15","author":"Jin","year":"2022","journal-title":"Int J Gen Med"},{"key":"R11-20251205","doi-asserted-by":"crossref","first-page":"e711","DOI":"10.1016\/j.wneu.2021.11.043","article-title":"Inter-rater reliability of Hounsfield units as a measure of bone density: Applications in the treatment of thoracolumbar fractures","volume":"158","author":"Ullrich","year":"2022","journal-title":"World Neurosurg"},{"key":"R12-20251205","doi-asserted-by":"crossref","first-page":"99","DOI":"10.22603\/ssrr.2020-0011","article-title":"Imaging in spine surgery: Current concepts and future directions","volume":"4","author":"Harada","year":"2020","journal-title":"Spine Surg Relat Res"},{"key":"R13-20251205","doi-asserted-by":"crossref","first-page":"1098","DOI":"10.1007\/s00586-020-06292-z","article-title":"Assessment of bone quality at the lumbar and sacral spine using CT scans: A retrospective feasibility study in 50 comparing CT and DXA data","volume":"29","author":"Berger-Groch","year":"2020","journal-title":"Eur Spine J"},{"key":"R14-20251205","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1016\/S1529-9430(01)00078-X","article-title":"Influence of bone mineral density on pedicle screw fixation: A study of pedicle screw fixation augmenting posterior lumbar interbody fusion in elderly patients","volume":"1","author":"Okuyama","year":"2001","journal-title":"Spine J"},{"key":"R15-20251205","doi-asserted-by":"crossref","first-page":"851","DOI":"10.1177\/2192568220975365","article-title":"Average lumbar Hounsfield units predicts osteoporosis-related complications following lumbar spine fusion","volume":"12","author":"St Jeor","year":"2022","journal-title":"Glob Spine J"},{"key":"R16-20251205","doi-asserted-by":"crossref","first-page":"668","DOI":"10.1016\/j.jocd.2022.09.002","article-title":"Inter-rater reliability and correlation of L1 Hounsfield unit measurements with DXA scores","volume":"25","author":"Mooney","year":"2022","journal-title":"J Clin Densitom"},{"key":"R17-20251205","doi-asserted-by":"crossref","first-page":"716","DOI":"10.3171\/2019.11.SPINE19868","article-title":"Computed tomography Hounsfield unit-based prediction of pedicle screw loosening after surgery for degenerative lumbar spine disease","volume":"32","author":"Zou","year":"2020","journal-title":"J Neurosurg Spine"},{"key":"R18-20251205","doi-asserted-by":"crossref","first-page":"734","DOI":"10.1016\/j.jos.2018.04.006","article-title":"Hounsfield unit of screw trajectory as a predictor of pedicle screw loosening after single level lumbar interbody fusion","volume":"23","author":"Sakai","year":"2018","journal-title":"J Orthop Sci"},{"key":"R19-20251205","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.jocn.2023.04.019","article-title":"Importance of computed tomography Hounsfield units in predicting S1 screw loosening after lumbosacral fusion","volume":"113","author":"Ishikawa","year":"2023","journal-title":"J Clin Neurosci"},{"key":"R20-20251205","doi-asserted-by":"crossref","first-page":"18279","DOI":"10.1038\/s41598-022-23142-8","article-title":"Value of computed tomography Hounsfield units in predicting pedicle screw loosening in the thoracic spine","volume":"12","author":"Lee","year":"2022","journal-title":"Sci Rep"},{"key":"R21-20251205","doi-asserted-by":"crossref","first-page":"960","DOI":"10.1186\/s12891-021-04833-1","article-title":"Hounsfield unit value on CT as a predictor of cage subsidence following stand-alone oblique lumbar interbody fusion for the treatment of degenerative lumbar diseases","volume":"22","author":"Zhou","year":"2021","journal-title":"BMC Musculoskelet Disord"},{"key":"R22-20251205","doi-asserted-by":"crossref","first-page":"1620","DOI":"10.1038\/s41598-023-28555-7","article-title":"CT Hounsfield unit is a reliable parameter for screws loosening or cages subsidence in minimally invasive transforaminal lumbar interbody fusion","volume":"13","author":"Yao","year":"2023","journal-title":"Sci Rep"},{"key":"R23-20251205","doi-asserted-by":"crossref","first-page":"1291","DOI":"10.1007\/s00590-021-03103-z","article-title":"Risk factors for cage subsidence and clinical outcomes after transforaminal and posterior lumbar interbody fusion","volume":"32","author":"Amorim-Barbosa","year":"2022","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"R24-20251205","doi-asserted-by":"crossref","first-page":"149","DOI":"10.21037\/jss-22-102","article-title":"The importance of Hounsfield units in adult spinal deformity surgery: Finding an optimal threshold to minimize the risk of mechanical complications","volume":"9","author":"Chanbour","year":"2023","journal-title":"J Spine Surg"},{"key":"R25-20251205","doi-asserted-by":"crossref","first-page":"E7","DOI":"10.3171\/2020.5.FOCUS20192","article-title":"The association between lower Hounsfield units of the upper instrumented vertebra and proximal junctional kyphosis in adult spinal deformity surgery with a minimum 2-year follow-up","volume":"49","author":"Duan","year":"2020","journal-title":"Neurosurg Focus"},{"key":"R26-20251205","doi-asserted-by":"crossref","first-page":"1086","DOI":"10.3390\/medicina59061086","article-title":"The relationship between the Hounsfield units value of the upper instrumented vertebra and the severity of proximal junctional fracture after adult spinal deformity surgery","volume":"59","author":"Yoshie","year":"2023","journal-title":"Medicina (Kaunas)"},{"key":"R27-20251205","doi-asserted-by":"crossref","first-page":"384","DOI":"10.3340\/jkns.2013.54.5.384","article-title":"Correlation between bone mineral density measured by dual-energy X-ray absorptiometry and Hounsfield units measured by diagnostic CT in lumbar spine","volume":"54","author":"Lee","year":"2013","journal-title":"J Korean Neurosurg Soc"},{"key":"R28-20251205","doi-asserted-by":"crossref","first-page":"920167","DOI":"10.3389\/fendo.2022.920167","article-title":"Hounsfield unit for assessing bone mineral density distribution within cervical vertebrae and its correlation with the intervertebral disc degeneration","volume":"13","author":"Liang","year":"2022","journal-title":"Front Endocrinol (Lausanne)"}],"container-title":["Journal of the American Academy of Orthopaedic Surgeons"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-24-01435","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T14:51:19Z","timestamp":1787669479000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-24-01435"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,18]]},"references-count":31,"journal-issue":{"issue":"24","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.5435\/jaaos-d-24-01435","relation":{},"ISSN":["1067-151X","1940-5480"],"issn-type":[{"value":"1067-151X","type":"print"},{"value":"1940-5480","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,18]]},"assertion":[{"value":"2024-12-03","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-03-02","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}