{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T15:28:38Z","timestamp":1787671718430,"version":"build-2736575974"},"reference-count":21,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","funder":[{"name":"Jesse B Jupiter Research Fund of the Wyss Medical Foundation"},{"DOI":"10.13039\/100016061","name":"Stichting de Drie Lichten","doi-asserted-by":"crossref","id":[{"id":"10.13039\/100016061","id-type":"DOI","asserted-by":"crossref"}]},{"name":"Catharine van Tussenbroek Foundation"},{"DOI":"10.13039\/501100014074","name":"Anna Fonds|NOREF","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100014074","id-type":"DOI","asserted-by":"crossref"}]},{"name":"Micha\u00ebl - van Vloten fonds"},{"DOI":"10.13039\/501100005797","name":"Vereniging Trustfonds Erasmus Universiteit Rotterdam","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100005797","id-type":"DOI","asserted-by":"crossref"}]},{"name":"Prins Bernhard Culture Fund"},{"DOI":"10.13039\/100018229","name":"Stichting Jo Kolk Studiefonds","doi-asserted-by":"crossref","id":[{"id":"10.13039\/100018229","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["J Am Acad Orthop Surg","JAAOS"],"published-print":{"date-parts":[[2026,1,1]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Volar plate fixation is a common surgical fixation method for distal radius fractures. The aim of the study was to perform a large-scale quantitative analysis of intact distal radius anatomy to (1) investigate the demographic and anatomical factors associated with lengths of locking screws for volar plate fixation and (2) determine the optimal screw distribution in a single-use distal radius set for the overall patient cohort, ensuring inclusion of all necessary screws while minimizing waste.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>CT scans from 198 wrists with an intact distal radius were evaluated. An open-source software module was used to automatically segment the distal radius and assemble a 3-dimensional anatomy for each patient. A quantitative map was computed to represent thickness across the volar surface. Variation in thickness was assessed in quantiles at the articular surface of the distal radius, using multivariate mixed modeling with respect to metaphyseal screw length and patient demographics.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Calculated across the entire patient cohort, the mean (95% percentile range) for each screw position was 10.2 (9.0 to 13.0) mm for the metaphyseal screw, 9.42 (6.7 to 13.8) mm for Qu1, 15.3 (11.4 to 20.5) mm for Qu2, 19.22 (15.6 to 22.3) mm for Qu3, 19.39 (16.2 to 23.0) mm for Qu4, and 16.22 (10.3 to 19.7) for Qu5. Female patients had a smaller mean thickness than male patients at Qu2 (\u22121.93 mm,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.003), Qu3 (\u22121.90 mm,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.003), Qu4 (\u22121.99 mm,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.002), and Qu5 (\u22122.21 mm,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001). For every 1 mm decrement in metaphyseal screw length, thickness was estimated to decrease by 0.518 mm (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001) at Qu2, 0.462 mm (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.002) at Qu3, and 0.462 mm (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.004) at Qu4.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>A high-resolution, high-fidelity anterior to posterior quantitative thickness map was constructed. This was used to find an effect of sex and metaphyseal screw length on distal locking screw length and an overall 95% percentile distribution of screw lengths.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.5435\/jaaos-d-25-00250","type":"journal-article","created":{"date-parts":[[2025,11,17]],"date-time":"2025-11-17T20:00:14Z","timestamp":1763409614000},"page":"e133-e143","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Quantitative Mapping of the Distal Radius to Aid Screw Selection for Volar Plate Fixation and Single-use Distal Radius Kits"],"prefix":"10.5435","volume":"34","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0520-1851","authenticated-orcid":false,"given":"Charlotte L. E.","family":"Laane","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jayanth S.","family":"Pratap","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rachel C.","family":"Cross","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Oscar","family":"Shen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mathieu M. E.","family":"Wijffels","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Neal C.","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abhiram R.","family":"Bhashyam","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,11,12]]},"reference":[{"key":"R1-20251219","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1016\/j.injury.2006.04.130","article-title":"Epidemiology of adult fractures: A review","volume":"37","author":"Court-Brown","year":"2006","journal-title":"Injury"},{"key":"R2-20251219","doi-asserted-by":"crossref","first-page":"908","DOI":"10.1053\/jhsu.2001.26322","article-title":"The frequency and epidemiology of hand and forearm fractures in the United States","volume":"26","author":"Chung","year":"2001","journal-title":"J Hand Surg Am"},{"key":"R3-20251219","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1186\/1471-2474-8-48","article-title":"Incidence and characteristics of distal radius fractures in a southern Swedish region","volume":"8","author":"Brogren","year":"2007","journal-title":"BMC Musculoskelet Disord"},{"key":"R4-20251219","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1186\/s12891-020-3097-8","article-title":"Epidemiology, classification, treatment and mortality of distal radius fractures in adults: An observational study of 23,394 fractures from the national Swedish fracture register","volume":"21","author":"Rundgren","year":"2020","journal-title":"BMC Musculoskelet Disord"},{"key":"R5-20251219","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1055\/s-0039-1685205","article-title":"Epidemiological and treatment trends of distal radius fractures across multiple age groups","volume":"8","author":"Azad","year":"2019","journal-title":"J Wrist Surg"},{"key":"R6-20251219","doi-asserted-by":"crossref","first-page":"110802","DOI":"10.1016\/j.injury.2023.05.033","article-title":"Changes in the incidence and treatment of distal radius fractures in adults\u2014A 22-year nationwide register study of 276,145 fractures","volume":"54","author":"Viberg","year":"2023","journal-title":"Injury"},{"key":"R7-20251219","doi-asserted-by":"crossref","first-page":"E346","DOI":"10.1097\/BOT.0000000000002049","article-title":"An economic analysis of direct costs of distal radius fixation and the implications of a disposable distal radius kit","volume":"35","author":"Lans","year":"2021","journal-title":"J Orthop Trauma"},{"key":"R8-20251219","doi-asserted-by":"crossref","first-page":"1282","DOI":"10.1016\/j.jhsa.2011.05.017","article-title":"Current and future national costs to medicare for the treatment of distal radius fracture in the elderly","volume":"36","author":"Shauver","year":"2011","journal-title":"J Hand Surg Am"},{"key":"R9-20251219","doi-asserted-by":"crossref","first-page":"103217","DOI":"10.1016\/j.otsr.2022.103217","article-title":"User satisfaction with single-use instruments versus reusable instruments for treating distal radius fractures with locking volar plates","volume":"108","author":"Descl\u00e9e de Maredsous","year":"2022","journal-title":"Orthop Traumatol Surg Res"},{"key":"R10-20251219","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1097\/BLO.0b013e318065b0bc","article-title":"Sterilization wrap inspections do not adequately evaluate instrument sterility","volume":"462","author":"Waked","year":"2007","journal-title":"Clin Orthop Relat Res"},{"key":"R11-20251219","doi-asserted-by":"crossref","first-page":"615","DOI":"10.1016\/j.jhsa.2006.01.011","article-title":"Volar fixed-angle plating of distal radius extension fractures: Influence of plate position on secondary loss of reduction: A biomechanic study in a cadaveric model","volume":"31","author":"Drobetz","year":"2006","journal-title":"J Hand Surg Am"},{"key":"R12-20251219","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1177\/230949901502300209","article-title":"Screw length in volar locking plate fixation for distal radial fractures","volume":"23","author":"Yuen","year":"2015","journal-title":"J Orthop Surg"},{"key":"R13-20251219","doi-asserted-by":"crossref","first-page":"354","DOI":"10.1177\/1753193419841269","article-title":"Predicting epiphyseal screw length in anterior plating of distal radial fractures","volume":"45","author":"Letissier","year":"2020","journal-title":"J Hand Surg Eur Vol"},{"key":"R14-20251219","doi-asserted-by":"crossref","first-page":"850","DOI":"10.1177\/1558944719831239","article-title":"Females are not proportionally smaller males: Relationships between radius anthropometrics and their sex differences","volume":"15","author":"Thom","year":"2020","journal-title":"Hand"},{"key":"R15-20251219","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1007\/s00402-014-2112-7","article-title":"Distal radius: Anatomical morphometric gender characteristics. Do anatomical pre-shaped plates pay attention on it?","volume":"135","author":"Oppermann","year":"2015","journal-title":"Arch Orthop Trauma Surg"},{"key":"R16-20251219","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1186\/s13018-015-0283-8","article-title":"The influence of distal screw length on the primary stability of volar plate osteosynthesis-a biomechanical study","volume":"10","author":"Baumbach","year":"2015","journal-title":"J Orthop Surg Res"},{"key":"R17-20251219","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1016\/j.jhsa.2011.12.013","article-title":"The effects of screw length on stability of simulated osteoporotic distal radius fractures fixed with volar locking plates","volume":"37","author":"Wall","year":"2012","journal-title":"J Hand Surg Am"},{"key":"R18-20251219","doi-asserted-by":"crossref","first-page":"674","DOI":"10.1111\/ans.17390","article-title":"Optimal screw length in volar locking plate osteosynthesis for distal radius fractures: A systematic review","volume":"92","author":"Gunaratne","year":"2022","journal-title":"ANZ J Surg"},{"key":"R19-20251219","doi-asserted-by":"crossref","first-page":"1186","DOI":"10.1016\/j.jhsa.2024.07.019","article-title":"Effect of screw length in volar plating for intra-articular distal radius fractures: A biomechanical study","volume":"49","author":"Hong","year":"2024","journal-title":"J Hand Surg Am"},{"key":"R20-20251219","doi-asserted-by":"crossref","first-page":"940","DOI":"10.1016\/j.jhsa.2015.01.008","article-title":"Predicting a safe screw length for volar plate fixation of distal radius fractures: Lunate depth as a marker for distal radius depth","volume":"40","author":"Ljungquist","year":"2015","journal-title":"J Hand Surg Am"},{"key":"R21-20251219","doi-asserted-by":"crossref","first-page":"646","DOI":"10.1016\/0002-9343(93)90218-E","article-title":"Consensus development conference: Diagnosis, prophylaxis, and treatment of osteoporosis","volume":"94","year":"1993","journal-title":"Am J Med"}],"container-title":["Journal of the American Academy of Orthopaedic Surgeons"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-25-00250","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T14:51:11Z","timestamp":1787669471000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-25-00250"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,12]]},"references-count":21,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.5435\/jaaos-d-25-00250","relation":{},"ISSN":["1067-151X","1940-5480"],"issn-type":[{"value":"1067-151X","type":"print"},{"value":"1940-5480","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,12]]},"assertion":[{"value":"2025-02-21","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-09-24","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}