{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T15:25:00Z","timestamp":1787671500004,"version":"build-2736575974"},"reference-count":15,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["J Am Acad Orthop Surg","JAAOS"],"published-print":{"date-parts":[[2026,3,1]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Current reliance on the expedited 510(k) approval pathway has driven rapid commercial availability of novel arthroscopic devices. Despite the low complication rates of arthroscopic procedures, products from this pathway are suspected to increase the rate of recalls and device malfunctions.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>This study aimed to characterize arthroscopic device recalls, analyze trends in recall incidence, and identify predictors of time to recall.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>A 20-year, retrospective, cross-sectional study was conducted using the Food and Drug Administration (FDA) Recalls database. Recalled devices approved under the FDA 510(k) pathway were identified and categorized by type, manufacturer, recall class, and cause. Statistical analyses included Poisson regression for trends and Cox proportional hazards modeling for predictors of time to recall.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>A total of 124 recalls were initiated during the study period (average 6.2 recalls\/year), with packaging and process control issues accounting for 50.7% of recalls. Recall incidence remained stable over time, although nearly half occurred in 2008, 2010, 2012, and 2019. Mean recall time was 491 days (95% confidence interval [CI], 444 to 539). Devices recalled due to material\/implant contamination had markedly shorter times (HR: 3.73 [95% CI, 1.78 to 7.82]), whereas process control issues prolonged recall times (HR: 0.56 [95% CI, 0.31 to 1.00]). Manufacturer was another predictor of time to recall, with one manufacturer exhibiting substantially extended recall times (HR: 0.45 [95% CI, 0.22 to 0.92]).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Arthroscopic device recalls are largely caused by packaging and process control issues, emphasizing the need for stricter quality assurance during manufacturing. Although recall incidence remained stable over the past two decades, variability in recall times highlights opportunities for improved manufacturer accountability and FDA oversight. Increasing procurement scrutiny, enhancing FDA audit practices, and integrating recall data with clinical outcomes can minimize disruptions in arthroscopic surgery.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Level of Evidence:<\/jats:title>\n                    <jats:p>Level III Therapeutic Study.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.5435\/jaaos-d-25-00371","type":"journal-article","created":{"date-parts":[[2025,9,4]],"date-time":"2025-09-04T21:00:10Z","timestamp":1757019610000},"page":"e738-e746","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Recalls of Arthroscopic Equipment After Food and Drug Administration 510(k) Approval: A Twenty-Year Analysis of Causes, Trends, and Time to Recall (2004 to 2024)"],"prefix":"10.5435","volume":"34","author":[{"given":"Thriaksh","family":"Rajan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian J.","family":"Hecht","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Comron","family":"Saifi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Prem N.","family":"Ramkumar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2098-7263","authenticated-orcid":false,"given":"R. Justin","family":"Mistovich","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,9,24]]},"reference":[{"key":"R2-20260220","doi-asserted-by":"crossref","first-page":"658","DOI":"10.5435\/JAAOS-D-22-00179","article-title":"The FDA and ensuring safety and effectiveness of devices, biologics, and technology","volume":"30","author":"Dubin","year":"2022","journal-title":"J Am Acad Orthop Surg"},{"key":"R3-20260220","doi-asserted-by":"crossref","first-page":"1558","DOI":"10.7326\/ANNALS-24-00728","article-title":"Modernizing medical device regulation: Challenges and opportunities for the 510(k) clearance process","volume":"177","author":"Kadakia","year":"2024","journal-title":"Ann Intern Med"},{"key":"R4-20260220","doi-asserted-by":"crossref","first-page":"e237699","DOI":"10.1001\/jamanetworkopen.2023.7699","article-title":"Risk of recall associated with modifications to high-risk medical devices approved through US food and Drug administration supplements","volume":"6","author":"Dubin","year":"2023","journal-title":"JAMA Netw Open"},{"key":"R5-20260220","first-page":"e093","article-title":"Complications after arthroscopic shoulder surgery: A review of the American board of orthopaedic surgery database","volume":"2","author":"Shin","year":"2018","journal-title":"J Am Acad Orthop Surg Glob Res Rev"},{"key":"R6-20260220","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1016\/S0749-8063(88)80030-6","article-title":"Complications in arthroscopic surgery performed by experienced arthroscopists","volume":"4","author":"Small","year":"1988","journal-title":"Arthroscopy"},{"key":"R7-20260220","doi-asserted-by":"crossref","first-page":"547","DOI":"10.2106\/JBJS.G.01439","article-title":"Medical errors in orthopaedics. Results of an AAOS member survey","volume":"91","author":"Wong","year":"2009","journal-title":"J Bone Joint Surg Am"},{"key":"R8-20260220","doi-asserted-by":"crossref","first-page":"517","DOI":"10.2106\/JBJS.15.00286","article-title":"Analysis of FDA-approved orthopaedic devices and their recalls","volume":"98","author":"Day","year":"2016","journal-title":"J Bone Joint Surg Am"},{"key":"R10-20260220","doi-asserted-by":"crossref","first-page":"854-9","DOI":"10.1016\/S0001-2092(07)70010-8","article-title":"Disinfection or sterilization? Four views on arthroscopes","volume":"37","author":"Crow","year":"1983","journal-title":"AORN J"},{"key":"R11-20260220","first-page":"158","article-title":"Minimally invasive orthopedic surgery: Arthroscopy","volume":"2","author":"Treuting","year":"2000","journal-title":"Ochsner J"},{"key":"R14-20260220","doi-asserted-by":"crossref","first-page":"987","DOI":"10.1177\/00034894211050434","article-title":"Spending and utilization on drugs prescribed by otolaryngologists to medicare beneficiaries, 2013 to 2017","volume":"131","author":"Shah","year":"2022","journal-title":"Ann Otol Rhinol Laryngol"},{"key":"R15-20260220","doi-asserted-by":"crossref","first-page":"1046","DOI":"10.1016\/j.arthro.2006.07.021","article-title":"Assessment of reprocessed arthroscopic shaver blades","volume":"22","author":"King","year":"2006","journal-title":"Arthroscopy"},{"key":"R16-20260220","doi-asserted-by":"crossref","first-page":"353","DOI":"10.52198\/22.STI.40.OS1553","article-title":"Improving operating room efficiency with single-use disposable instruments for total knee arthroplasty","volume":"40","author":"Crawford","year":"2022","journal-title":"Surg Technol Int"},{"key":"R17-20260220","first-page":"e48750","article-title":"A comprehensive review of postoperative analgesics used in orthopedic practice","volume":"15","author":"Goel","year":"2023","journal-title":"Cureus"},{"key":"R18-20260220","doi-asserted-by":"crossref","first-page":"103993","DOI":"10.1016\/j.drudis.2024.103993","article-title":"A retrospective regulatory analysis of FDA recalls carried out by pharmaceutical companies from 2012 to 2023","volume":"29","author":"Patel","year":"2024","journal-title":"Drug Discov Today"},{"key":"R19-20260220","article-title":"Association between regulatory submission characteristics and recalls of medical devices receiving 510(k) clearance. Medical devices and equipment","journal-title":"JAMA"}],"container-title":["Journal of the American Academy of Orthopaedic Surgeons"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-25-00371","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T14:44:14Z","timestamp":1787669054000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-25-00371"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,24]]},"references-count":15,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.5435\/jaaos-d-25-00371","relation":{},"ISSN":["1067-151X","1940-5480"],"issn-type":[{"value":"1067-151X","type":"print"},{"value":"1940-5480","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,24]]},"assertion":[{"value":"2025-03-20","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-07-15","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}