{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T13:24:02Z","timestamp":1788528242867,"version":"build-2803163510"},"reference-count":39,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"18","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["J Am Acad Orthop Surg","JAAOS"],"published-print":{"date-parts":[[2026,9,15]]},"abstract":"<jats:sec>\n                    <jats:title\/>\n                    <jats:p>Pedicle screws and rods are the cornerstone of spine instrumentation. This article focuses on the practical usage of these implants in contemporary spine practice. Furthermore, we discuss strategies to optimize fixation in osteoporotic spine and implant-related considerations in preventing proximal junctional kyphosis. Cross-sectional imaging helps select the longest screws with maximum outer diameter that can be safely placed. Conical inner diameter with V-shaped thread provides best pullout strength. Dual-core, dual-thread screws are biomechanically superior to conventional screws. For pedicle screw placement, undertapping or no tapping and convergent trajectory is recommended. Polyaxial, uniaxial, and monoaxial screws have shown similar clinical and radiologic results. Cortical bone trajectory screws and sublaminar bands can provide alternative fixation options to pedicle screws. Cement augmentation through cannulated fenestrated screws is the most reliable method of pedicle screw augmentation in osteoporotic spine. Alternatively, biodegradable cement augmentation, HA-coated screws, and expandable screws can be used. Both titanium and cobalt-chromium rods have shown similar clinical and radiologic results. Precontoured rods are recommended to prevent notching. Multiple rods are recommended at L5-S1 and osteotomies to prevent complications. \u201cSoft landing\u201d using hooks or sublaminar band, and vertebroplasty at the cranial end of the construct may prevent proximal junctional kyphosis.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.5435\/jaaos-d-25-00786","type":"journal-article","created":{"date-parts":[[2026,4,15]],"date-time":"2026-04-15T11:01:30Z","timestamp":1776250890000},"page":"e2427-e2438","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Thoracolumbar Instrumentation Options: Biomechanical Implications"],"prefix":"10.5435","volume":"34","author":[{"ORCID":"https:\/\/orcid.org\/0009-0000-2909-0271","authenticated-orcid":false,"given":"Saurabh","family":"Rawall","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luke A.","family":"Hiatt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Steven","family":"Theiss","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sakthivel M.","family":"Rajaram","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,4,15]]},"reference":[{"key":"R1-20260904","doi-asserted-by":"crossref","first-page":"1061","DOI":"10.1302\/0301-620X.92B8.24237","article-title":"The biomechanics of pedicle screw-based instrumentation","volume":"92","author":"Cho","year":"2010","journal-title":"J Bone Joint Surg Br"},{"key":"R2-20260904","doi-asserted-by":"crossref","first-page":"E226","DOI":"10.1097\/BSD.0000000000000151","article-title":"Minimizing pedicle screw pullout risks: A detailed biomechanical analysis of screw design and placement","volume":"30","author":"Bianco","year":"2017","journal-title":"Clin Spine Surg"},{"key":"R4-20260904","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1016\/j.spinee.2012.01.014","article-title":"Assessment of pedicle screw pullout strength based on various screw designs and bone densities\u2014An ex vivo biomechanical study","volume":"12","author":"Kim","year":"2012","journal-title":"Spine J"},{"key":"R5-20260904","doi-asserted-by":"crossref","first-page":"947","DOI":"10.1016\/j.spinee.2013.03.010","article-title":"Characteristics of immediate and fatigue strength of a dual-threaded pedicle screw in cadaveric spines","volume":"13","author":"Brasiliense","year":"2013","journal-title":"Spine J"},{"key":"R6-20260904","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1097\/BRS.0b013e31819e2753","article-title":"Treatment of thoracic scoliosis: Are monoaxial thoracic pedicle screws the best form of fixation for correction?","volume":"34","author":"Lonner","year":"2009","journal-title":"Spine"},{"key":"R7-20260904","doi-asserted-by":"crossref","first-page":"669","DOI":"10.21037\/atm-21-881","article-title":"A comparison of monoaxial pedicle screw versus polyaxial pedicle screw in short-segment posterior fixation for the treatment of thoracolumbar fractured vertebra","volume":"9","author":"Yao","year":"2021","journal-title":"Ann Transl Med"},{"key":"R8-20260904","doi-asserted-by":"crossref","first-page":"e558","DOI":"10.1097\/BPO.0000000000000927","article-title":"Uniplanar versus fixed pedicle screws in the correction of thoracic kyphosis in the treatment of adolescent idiopathic scoliosis (AIS)","volume":"37","author":"Badve","year":"2017","journal-title":"J Pediatr Orthop"},{"key":"R9-20260904","doi-asserted-by":"crossref","first-page":"1257","DOI":"10.5435\/JAAOS-D-24-01088","article-title":"Management of pyogenic spondylodiscitis in adults","volume":"33","author":"Rawall","year":"2025","journal-title":"J Am Acad Orthop Surg"},{"key":"R10-20260904","doi-asserted-by":"crossref","first-page":"364","DOI":"10.3171\/spi.2005.3.5.0364","article-title":"Effects of pilot hole preparation technique on pedicle screw fixation in different regions of the osteoporotic thoracic and lumbar spine","volume":"3","author":"Carmouche","year":"2005","journal-title":"J Neurosurg Spine"},{"key":"R11-20260904","doi-asserted-by":"crossref","first-page":"1640","DOI":"10.1097\/BRS.0000000000000477","article-title":"Pedicle screw reinsertion using previous pilot hole and trajectory does not reduce fixation strength","volume":"39","author":"Kang","year":"2014","journal-title":"Spine"},{"key":"R12-20260904","doi-asserted-by":"crossref","first-page":"E4","DOI":"10.3171\/2021.10.FOCUS21526","article-title":"Does robot-assisted navigation influence pedicle screw selection and accuracy in minimally invasive spine surgery?","volume":"52","author":"Shafi","year":"2022","journal-title":"Neurosurg Focus"},{"key":"R13-20260904","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1016\/j.wneu.2019.10.079","article-title":"The era of cortical bone trajectory screws in spine surgery: A qualitative review with rating of evidence","volume":"134","author":"Cofano","year":"2020","journal-title":"World Neurosurg"},{"key":"R14-20260904","doi-asserted-by":"crossref","first-page":"1519","DOI":"10.1016\/j.spinee.2015.02.038","article-title":"The comparison of pedicle screw and cortical screw in posterior lumbar interbody fusion: A prospective randomized noninferiority trial","volume":"15","author":"Lee","year":"2015","journal-title":"Spine J"},{"key":"R15-20260904","doi-asserted-by":"crossref","first-page":"57","DOI":"10.3171\/2017.5.SPINE161154","article-title":"Cortical bone trajectory screw fixation versus traditional pedicle screw fixation for 2-level posterior lumbar interbody fusion: Comparison of surgical outcomes for 2-level degenerative lumbar spondylolisthesis","volume":"28","author":"Sakaura","year":"2018","journal-title":"J Neurosurg Spine"},{"key":"R16-20260904","doi-asserted-by":"crossref","first-page":"778","DOI":"10.1016\/j.jcot.2020.06.028","article-title":"Advancements in osteoporotic spine fixation","volume":"11","author":"Tandon","year":"2020","journal-title":"J Clin Orthop Trauma"},{"key":"R17-20260904","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1016\/j.spinee.2010.09.024","article-title":"Instrumentation of the osteoporotic spine: Biomechanical and clinical considerations","volume":"11","author":"Ponnusamy","year":"2011","journal-title":"Spine J"},{"key":"R18-20260904","doi-asserted-by":"crossref","first-page":"807","DOI":"10.3171\/2018.11.SPINE181154","article-title":"Sublaminar banding as an adjunct to pedicle screw-rod constructs: A review and technical note on novel hybrid constructs in spinal deformity surgery","volume":"30","author":"Viswanathan","year":"2019","journal-title":"J Neurosurg Spine"},{"key":"R19-20260904","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1097\/BPO.0000000000000235","article-title":"Hybrid fixation with sublaminar polyester bands in the treatment of neuromuscular scoliosis: A comparative analysis","volume":"35","author":"Albert","year":"2015","journal-title":"J Pediatr Orthop"},{"key":"R20-20260904","doi-asserted-by":"crossref","first-page":"1637","DOI":"10.1016\/j.spinee.2018.03.009","article-title":"Biomechanical comparative study of the stability of injectable pedicle screws with different lateral holes augmented with different volumes of polymethylmethacrylate in osteoporotic lumbar vertebrae","volume":"18","author":"Liu","year":"2018","journal-title":"Spine J"},{"key":"R21-20260904","doi-asserted-by":"crossref","first-page":"E351","DOI":"10.1097\/BSD.0b013e31828bfc85","article-title":"Biomechanical comparison of expansive pedicle screw and polymethylmethacrylate-augmented pedicle screw in osteoporotic synthetic bone in primary implantation: An experimental study","volume":"29","author":"Liu","year":"2016","journal-title":"Clin Spine Surg"},{"key":"R22-20260904","doi-asserted-by":"crossref","first-page":"1722","DOI":"10.1097\/BRS.0000000000004995","article-title":"Preoperative hounsfield units predict pedicle screw loosening in osteoporotic patients following short-segment lumbar fusion","volume":"49","author":"Narayanan","year":"2024","journal-title":"Spine"},{"key":"R23-20260904","doi-asserted-by":"crossref","first-page":"309","DOI":"10.3171\/2024.4.SPINE2424","article-title":"Change in spinal bone mineral density as estimated by hounsfield units following osteoporosis treatment with romosozumab, teriparatide, denosumab, and alendronate: An analysis of 318 patients: Presented at the 2024 AANS\/CNS joint section on disorders of the spine and peripheral nerves","volume":"41","author":"Mikula","year":"2024","journal-title":"J Neurosurg Spine"},{"key":"R24-20260904","doi-asserted-by":"crossref","first-page":"1350","DOI":"10.1016\/j.spinee.2013.04.022","article-title":"Rods in spinal surgery: A review of the literature","volume":"13","author":"Yoshihara","year":"2013","journal-title":"Spine J official J North Am Spine Soc"},{"key":"R25-20260904","doi-asserted-by":"crossref","first-page":"1265","DOI":"10.1007\/s43390-022-00556-y","article-title":"Systematic review and meta-analysis for the impact of rod materials and sizes in the surgical treatment of adult spine deformity","volume":"10","author":"Bowden","year":"2022","journal-title":"Spine Deform"},{"key":"R26-20260904","doi-asserted-by":"crossref","first-page":"2174","DOI":"10.3390\/jcm13082174","article-title":"The influence of increased pedicle screw diameter and thicker rods on surgical results in adolescents undergoing posterior spinal fusion for idiopathic scoliosis","volume":"13","author":"Grabala","year":"2024","journal-title":"J Clin Med"},{"key":"R27-20260904","doi-asserted-by":"crossref","first-page":"E312","DOI":"10.1097\/BRS.0000000000003269","article-title":"Mechanical analysis of notch-free pre-bent rods for spinal deformity surgery","volume":"45","author":"Yamada","year":"2020","journal-title":"Spine"},{"key":"R28-20260904","doi-asserted-by":"crossref","first-page":"1023","DOI":"10.3171\/2021.10.SPINE21745","article-title":"The lexicon of multirod constructs in adult spinal deformity: A concise description of when, why, and how","volume":"36","author":"Ramey","year":"2022","journal-title":"J Neurosurg Spine"},{"key":"R29-20260904","doi-asserted-by":"crossref","first-page":"415","DOI":"10.3171\/2019.9.SPINE19389","article-title":"The \u201ckickstand rod\u201d technique for correction of coronal imbalance in patients with adult spinal deformity: Initial case series","volume":"32","author":"Makhni","year":"2020","journal-title":"J Neurosurg Spine"},{"key":"R30-20260904","doi-asserted-by":"crossref","first-page":"118","DOI":"10.4103\/jcvjs.jcvjs_166_24","article-title":"A novel approach to partial reduction of high-grade spondylolisthesis with offset rods\u2014A report of two cases","volume":"16","author":"Rawall","year":"2025","journal-title":"J Craniovertebr Junction Spine"},{"key":"R31-20260904","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1007\/s00586-020-06597-z","article-title":"Cross-links in posterior pedicle screw-rod instrumentation of the spine: A systematic review on mechanical, biomechanical, numerical and clinical studies","volume":"30","author":"Cornaz","year":"2021","journal-title":"Eur Spine J"},{"key":"R32-20260904","doi-asserted-by":"crossref","first-page":"1895","DOI":"10.1007\/s00586-018-5664-3","article-title":"In vitro investigation of two connector types for continuous rod construct to extend lumbar spinal instrumentation","volume":"27","author":"Welke","year":"2018","journal-title":"Eur Spine J"},{"key":"R33-20260904","doi-asserted-by":"crossref","first-page":"842","DOI":"10.1016\/j.spinee.2021.01.011","article-title":"Instrumentation techniques to prevent proximal junctional kyphosis and proximal junctional failure in adult spinal deformity Correction\u2014A systematic review of biomechanical studies","volume":"21","author":"Doodkorte","year":"2021","journal-title":"Spine J"},{"key":"R34-20260904","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1007\/s43390-020-00278-z","article-title":"State of the art: Proximal junctional Kyphosis\u2014Diagnosis, management and prevention","volume":"9","author":"Sardar","year":"2021","journal-title":"Spine Deform"},{"key":"R35-20260904","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1016\/j.nec.2023.06.004","article-title":"Proximal junctional kyphosis and failure: Strategies for prevention","volume":"34","author":"Arora","year":"2023","journal-title":"Neurosurg Clin N Am"},{"key":"R36-20260904","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1016\/j.wneu.2016.08.008","article-title":"Spinal implant density and postoperative lumbar lordosis as predictors for the development of proximal junctional kyphosis in adult spinal deformity","volume":"95","author":"McClendon","year":"2016","journal-title":"World Neurosurg"},{"key":"R37-20260904","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1016\/j.jspd.2013.05.008","article-title":"Type of anchor at the proximal fusion level has a significant effect on the incidence of proximal junctional kyphosis and outcome in adults after long posterior spinal fusion","volume":"1","author":"Hassanzadeh","year":"2013","journal-title":"Spine Deform"},{"key":"R38-20260904","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1016\/j.jspd.2013.01.005","article-title":"Preliminary results of the effect of prophylactic vertebroplasty on the incidence of proximal junctional complications after posterior spinal fusion to the low thoracic spine","volume":"1","author":"Martin","year":"2013","journal-title":"Spine Deform"},{"key":"R39-20260904","doi-asserted-by":"crossref","first-page":"1489","DOI":"10.1016\/j.spinee.2017.05.017","article-title":"The effect of prophylactic vertebroplasty on the incidence of proximal junctional kyphosis and proximal junctional failure following posterior spinal fusion in adult spinal deformity: A 5-year follow-up study","volume":"17","author":"Raman","year":"2017","journal-title":"Spine J"},{"key":"R40-20260904","first-page":"37","article-title":"Is proximal triangular fixation better than the conventional method in adult spinal deformity surgery","volume":"78","author":"Tanaka","year":"2024","journal-title":"Acta Med Okayama"}],"container-title":["Journal of the American Academy of Orthopaedic Surgeons"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-25-00786","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T13:01:40Z","timestamp":1788526900000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-25-00786"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,15]]},"references-count":39,"journal-issue":{"issue":"18","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.5435\/jaaos-d-25-00786","relation":{},"ISSN":["1067-151X","1940-5480"],"issn-type":[{"value":"1067-151X","type":"print"},{"value":"1940-5480","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,15]]},"assertion":[{"value":"2025-06-22","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-02-15","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}