{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T15:18:52Z","timestamp":1787671132108,"version":"build-2736575974"},"reference-count":14,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"13","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["J Am Acad Orthop Surg","JAAOS"],"published-print":{"date-parts":[[2026,7,1]]},"abstract":"<jats:sec>\n                    <jats:title>Background and Purpose:<\/jats:title>\n                    <jats:p>This study investigated depth-dose alterations caused by bone cement in solid phantoms during vertebroplasty. Dose variations of megavoltage (MV) photon beams after traversing high-density bone cement were measured to estimate the effective density of bone cement.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>\n                      A phantom mimicking human anatomy was fabricated with 2.5-cm acrylic embedded with bone cement. An Elekta VersaHD linear accelerator was used with 6 MV and 6 MV flattening filter-free (FFF) photon beams, field sizes ranging from 3 \u00d7 3 cm\n                      <jats:sup>2<\/jats:sup>\n                      to 10 \u00d7 10 cm\n                      <jats:sup>2<\/jats:sup>\n                      . Depth dose, planar dose, and point dose were measured using an Advanced Markus chamber, PTW 1600 two-dimensional array, and Semiflex three-dimensional ion chamber. These were compared with calculated doses from treatment plans with various overridden density values for bone cement.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Minimal differences in percent depth dose were observed after MV photons (6 MV and 6 MV FFF) penetrated the bone cement. At 1 cm beyond cement, measured versus calculated doses differed by 1.2% to 2.7%. Within 1 to 5 cm behind cement, dose discrepancies were within 3% to 5%. At 3-cm depth behind cement, point-dose differences measured by the Semiflex chamber indicated smaller deviations at lower override densities, with an optimal match at 0.6 g\/cm\n                      <jats:sup>3<\/jats:sup>\n                      . The two-dimensional array showed near-perfect gamma passing rates (\u223c100%) at an overridden density of 0.8 g\/cm\n                      <jats:sup>3<\/jats:sup>\n                      , demonstrating the smallest center-point dose discrepancies. A higher override density of 1.4 g\/cm\n                      <jats:sup>3<\/jats:sup>\n                      yielded results similar to the plan without density override, suggesting minimal advantage at higher override densities.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>\n                      This study revealed that dose perturbations induced by bone cement caused the treatment planning system to underestimate actual delivered doses by approximately 3% to 5%. Optimal density override values for bone cement in treatment planning systems appear to be around 0.6 to 0.8 g\/cm\n                      <jats:sup>3<\/jats:sup>\n                      . Clinical trials and further data acquisition are necessary to validate precise density values due to variability in cement composition and incomplete cement infusion.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.5435\/jaaos-d-25-00869","type":"journal-article","created":{"date-parts":[[2026,4,21]],"date-time":"2026-04-21T14:05:11Z","timestamp":1776780311000},"page":"e1818-e1827","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Assessment of Dose Calculation Accuracy for Bone Cement Implants in Radiation Therapy Planning Systems"],"prefix":"10.5435","volume":"34","author":[{"given":"Po-Wei","family":"Wu","sequence":"first","affiliation":[{"name":"Department of Post-Baccalaureate Medicine, College of Medicine, National Chung Hsing University, Taichung, Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuan-Chun","family":"Lai","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Changhua Christian Hospital, Changhua, Taiwan"},{"name":"Department of Medical Imaging and Radiological Sciences, Central Taiwan University of Science and Technology, Taichung, Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1297-4825","authenticated-orcid":false,"given":"Wei-Hsun","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Post-Baccalaureate Medicine, College of Medicine, National Chung Hsing University, Taichung, Taiwan"},{"name":"Department of Orthopedic Surgery, Changhua Christian Hospital, Changhua, Taiwan"},{"name":"Department of Golden-Ager Industry Management, Chaoyang University of Technology, Taichung, Taiwan"},{"name":"Department of Medical Imaging and Radiology, Shu-Zen Junior College of Medicine and Management, Kaohsiung, Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,4,21]]},"reference":[{"key":"R1-20260622","doi-asserted-by":"crossref","first-page":"652","DOI":"10.1016\/j.ijrobp.2008.02.060","article-title":"Stereotactic body radiosurgery for spinal metastases: A critical review","volume":"71","author":"Sahgal","year":"2008","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"R2-20260622","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1016\/j.ejmp.2021.04.023","article-title":"Addressing the dosimetric impact of bone cement and vertebroplasty in stereotactic body radiation therapy","volume":"85","author":"Dumas","year":"2021","journal-title":"Phys Med"},{"key":"R3-20260622","first-page":"571571","article-title":"Does vertebroplasty affect radiation dose distribution?: Comparison of spatial dose distributions in a cement-injected vertebra as calculated by treatment planning system and actual spatial dose distribution","volume":"2012","author":"Komemushi","year":"2012","journal-title":"Radiol Res Pract"},{"key":"R4-20260622","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1016\/j.meddos.2010.05.005","article-title":"Proton range uncertainty due to bone cement injected into the vertebra in radiation therapy planning","volume":"36","author":"Lim","year":"2011","journal-title":"Med Dosim"},{"key":"R5-20260622","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.phro.2020.04.004","article-title":"Impact of radiopacified bone cement on radiotherapy dose calculation","volume":"14","author":"Crowe","year":"2020","journal-title":"Phys Imaging Radiat Oncol"},{"key":"R6-20260622","doi-asserted-by":"crossref","first-page":"64","DOI":"10.2478\/lpts-2022-0012","article-title":"Study on mass and linear attenuation coefficients of PMMA as human tissue-equivalent material","volume":"59","author":"Hamideenl","year":"2022","journal-title":"Latvian J Phys Tech Sci"},{"key":"R7-20260622","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1120\/jacmp.v17i1.5700","article-title":"Soft tissue and water substitutes for megavoltage photon beams: An EGSnrc-based evaluation","volume":"17","author":"Aslam","year":"2016","journal-title":"J Appl Clin Med Phys"},{"key":"R8-20260622","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1016\/j.meddos.2010.05.005","article-title":"Proton range uncertainty due to bone cement injected into the vertebra in radiation therapy planning","volume":"36","author":"Lim","year":"2011","journal-title":"Med Dosim"},{"key":"R9-20260622","doi-asserted-by":"crossref","first-page":"1160","DOI":"10.18203\/2320-6012.ijrms20230854","article-title":"Comparison of 2D and 3D gamma evaluation method in patient specific intensity-modulated radiotherapy quality assurance","volume":"11","author":"Shukla","year":"2023","journal-title":"Int J Res Med Sci"},{"key":"R10-20260622","doi-asserted-by":"crossref","first-page":"3661","DOI":"10.1118\/1.2952643","article-title":"The extraction of true profiles for TPS commissioning and its impact on IMRT patient-specific QA","volume":"35","author":"Yan","year":"2008","journal-title":"Med Phys"},{"key":"R11-20260622","doi-asserted-by":"crossref","first-page":"1057","DOI":"10.1002\/jbm.820200802","article-title":"Influence of mixing technique on some properties of PMMA bone cement","volume":"20","author":"Eyerer","year":"1986","journal-title":"J Biomed Mater Res"},{"key":"R12-20260622","doi-asserted-by":"crossref","first-page":"5717","DOI":"10.1118\/1.4963207","article-title":"The effect of density variation on photon dose calculation and its impact on intensity modulated radiotherapy and stereotactic body radiotherapy","volume":"43","author":"Liu","year":"2016","journal-title":"Med Phys"},{"key":"R13-20260622","first-page":"326","article-title":"Influence of temperature and vacuum mixing on bone cement properties","volume":"334","author":"Semeds","year":"1997","journal-title":"Clin Orthop Relat Res"},{"key":"R14-20260622","doi-asserted-by":"crossref","first-page":"143","DOI":"10.3109\/17453679308994555","article-title":"Porosity of bone cement reduced by mixing and collecting under vacuum","volume":"64","author":"Wang","year":"1993","journal-title":"Acta Orthop Scand"}],"container-title":["Journal of the American Academy of Orthopaedic Surgeons"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-25-00869","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T14:39:23Z","timestamp":1787668763000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-25-00869"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,21]]},"references-count":14,"journal-issue":{"issue":"13","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.5435\/jaaos-d-25-00869","relation":{},"ISSN":["1067-151X","1940-5480"],"issn-type":[{"value":"1067-151X","type":"print"},{"value":"1940-5480","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,21]]},"assertion":[{"value":"2025-07-13","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-02-18","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}