{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T22:05:03Z","timestamp":1789769103643,"version":"4.0.1"},"reference-count":14,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"19","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["J Am Acad Orthop Surg","JAAOS"],"published-print":{"date-parts":[[2026,10,1]]},"abstract":"<jats:sec>\n                    <jats:title>Introduction:<\/jats:title>\n                    <jats:p>Implant-implant impingement in total hip arthroplasty remains a primarily clinical diagnosis, with little technology available to demonstrate impingement radiographically. The purpose of this study was to determine the effectiveness of external rotation stress CT scans in evaluating for posterior impingement in patients with painful total hip prostheses.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Sixty-seven patients presenting with CT IMA (implant movement analysis) scans previously used for evaluation of potential aseptic loosening were identified between May 2021 and May 2024. Plain radiographs were evaluated to assess for acetabular cup abduction. CT IMA scans in external rotation IMA protocol position were evaluated to measure acetabular implant version and the distance between the femoral and acetabular components. Patients were separated into impingement and nonimpingement groups based on whether a clinical or intraoperative diagnosis of impingement had been made. Cup version, abduction, and implant-implant distances on the external rotation CT were compared between the groups. A receiver operating characteristic curve was created, and the area under the curve was calculated to determine an optimal implant-implant distance for diagnosing impingement.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Overall, 29 patients were diagnosed with impingement and 38 patients were diagnosed with other sources of hip pain. Linear regression showed a notable negative correlation (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.004) of measured cup version versus implant-implant distance. Implant-implant distance was markedly smaller in the impingement group versus the non-impingement group (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.0001). The receiver operating characteristic curve demonstrated 100% sensitivity and 89% specificity impingement when the implant-implant distance was &lt;5 mm, with an area under the curve of 0.98 \u00b1 0.02.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>External rotation stress CT scans used by the IMA protocol were 100% sensitive and 89% specific in identifying patients with posterior impingement when an implant-implant distance of &lt;5 mm was considered. This technology may help clinicians objectively define a diagnosis of impingement in total hip prostheses in the absence of other clinically identifiable sources of pain.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.5435\/jaaos-d-25-01440","type":"journal-article","created":{"date-parts":[[2026,3,18]],"date-time":"2026-03-18T11:00:14Z","timestamp":1773831614000},"page":"e2822-e2828","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["A Novel Technique for Diagnosing Posterior Implant-Implant Impingement After Total Hip Arthroplasty"],"prefix":"10.5435","volume":"34","author":[{"given":"Alexander","family":"Kovacs","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1091-9286","authenticated-orcid":false,"given":"Thomas","family":"Listopadzki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K. Keely","family":"Boyle","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4311-2240","authenticated-orcid":false,"given":"Scott R.","family":"Nodzo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,3,18]]},"reference":[{"key":"R1-20260918","doi-asserted-by":"crossref","first-page":"1386","DOI":"10.2106\/JBJS.N.01141","article-title":"Prevalence of total hip and knee replacement in the United States","volume":"97","author":"Maradit Kremers","year":"2015","journal-title":"J Bone Joint Surg Am"},{"key":"R2-20260918","doi-asserted-by":"crossref","first-page":"376","DOI":"10.1016\/j.cuor.2008.10.009","article-title":"Impingement in total hip replacement: Mechanisms and consequences","volume":"22","author":"Brown","year":"2008","journal-title":"Curr Orthop"},{"key":"R3-20260918","first-page":"1832","article-title":"Impingement with total hip replacement","volume":"89","author":"Malik","year":"2007","journal-title":"J Bone Joint Surg Am"},{"key":"R4-20260918","doi-asserted-by":"crossref","first-page":"9544119211069472","DOI":"10.1177\/09544119211069472","article-title":"Impingement in total hip arthroplasty: A geometric model","volume":"236","author":"Pryce","year":"2022","journal-title":"Proc Inst Mech Eng H"},{"key":"R5-20260918","doi-asserted-by":"crossref","first-page":"1300","DOI":"10.2106\/00004623-200009000-00010","article-title":"The effect of femoral component head size on posterior dislocation of the artificial hip joint","volume":"82","author":"Bartz","year":"2000","journal-title":"J Bone Joint Surg Am"},{"key":"R6-20260918","doi-asserted-by":"crossref","first-page":"315","DOI":"10.2106\/00004623-200003000-00003","article-title":"The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios","volume":"82","author":"D'Lima","year":"2000","journal-title":"J Bone Joint Surg Am"},{"key":"R7-20260918","doi-asserted-by":"crossref","first-page":"329","DOI":"10.4055\/cios20274","article-title":"Assessment of acetabular component anteversion after total hip arthroplasty: Comparison of anteroposterior and cross-table lateral radiographs with computed tomography scans","volume":"13","author":"Goyal","year":"2021","journal-title":"Clin Orthop Surg"},{"key":"R8-20260918","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1016\/j.carj.2015.11.003","article-title":"Imaging of the painful hip arthroplasty","volume":"67","author":"Hargunani","year":"2016","journal-title":"Can Assoc Radiol J"},{"key":"R9-20260918","doi-asserted-by":"crossref","first-page":"S270","DOI":"10.1016\/j.arth.2025.04.012","article-title":"Computed tomography with implant movement analysis in the work-up of painful total hip prostheses","volume":"40","author":"Listopadzki","year":"2025","journal-title":"J Arthroplasty"},{"key":"R10-20260918","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1080\/17453674.2020.1725345","article-title":"Low-dose CT-based implant motion analysis is a precise tool for early migration measurements of hip cups: A clinical study of 24 patients","volume":"91","author":"Broden","year":"2020","journal-title":"Acta Orthop"},{"key":"R11-20260918","doi-asserted-by":"crossref","first-page":"815","DOI":"10.1016\/j.orthres.2003.11.001","article-title":"Compliant positioning of total hip components for optimal range of motion","volume":"22","author":"Widmer","year":"2004","journal-title":"J Orthop Res"},{"key":"R12-20260918","doi-asserted-by":"crossref","first-page":"386","DOI":"10.1007\/s11999-015-4432-5","article-title":"What safe zone? The vast majority of dislocated THAs are within the lewinnek safe zone for acetabular component position","volume":"474","author":"Abdel","year":"2016","journal-title":"Clin Orthop Relat Res"},{"key":"R13-20260918","doi-asserted-by":"crossref","first-page":"S257","DOI":"10.1016\/j.arth.2023.04.031","article-title":"Does individualization of cup position affect prosthetic or bone impingement following total hip arthroplasty?","volume":"38","author":"Dennis","year":"2023","journal-title":"J Arthroplasty"},{"key":"R14-20260918","doi-asserted-by":"crossref","first-page":"S678","DOI":"10.1016\/j.arth.2022.02.112","article-title":"Three-dimensional functional impingement in total hip arthroplasty: A biomechanical analysis","volume":"37","author":"Debbi","year":"2022","journal-title":"J Arthroplasty"}],"container-title":["Journal of the American Academy of Orthopaedic Surgeons"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-25-01440","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T22:00:22Z","timestamp":1789768822000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-25-01440"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,18]]},"references-count":14,"journal-issue":{"issue":"19","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.5435\/jaaos-d-25-01440","relation":{},"ISSN":["1067-151X","1940-5480"],"issn-type":[{"value":"1067-151X","type":"print"},{"value":"1940-5480","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,18]]},"assertion":[{"value":"2025-11-19","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-02-07","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}