{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T17:20:30Z","timestamp":1788283230564,"version":"build-2803163510"},"reference-count":31,"publisher":"Ovid Technologies (Wolters Kluwer Health)","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["J Am Acad Orthop Surg","JAAOS"],"abstract":"<jats:sec>\n                    <jats:title>Introduction:<\/jats:title>\n                    <jats:p>Total ankle arthroplasty (TAA) has become a viable alternative to ankle arthrodesis (AA) in recent years. However, implant longevity is a concern because malalignment of either the tibial or talar implants has been shown to predispose to premature wear and necessary revision surgery. Thus, customized surgical tools such as computer navigation and patient-specific instrumentation have been used to theoretically improve intraoperative alignment of implants. The primary outcome of this study is to compare alignment between a computer-assisted navigation (CAN) system for TAA, a preexisting patient-specific instrumentation (PSI) system, and SRG fluoroscopic techniques.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>TAA was done on 36 artificial ankle joint specimens by a single surgeon: 12 using CAN, 12 with PSI, and 12 with SRG instrumentation. All specimens were scanned both preoperatively and postoperatively using a high-precision 3D scanning tool. Resections and implant placements were then analyzed in 3D processing software and compared between surgical modalities. Statistical analysis included one-way ANOVA with associated Tukey tests to assess for differences between groups.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      We found that tibial resections were overall most accurate using CAN, with tibial slope measurements demonstrating significant improvements over PSI (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001) and conventional instrumentation (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001). PSI was more accurate than SRG when considering the axial cut height of the tibial resection (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001). In the talar resections, CAN was statistically superior to SRG methods in two of three measured categories (slope:\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001, axial cut height:\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001). However, PSI fared better than CAN in those same categories (slope:\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.002, axial cut height:\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001). Employment of the CAN system also decreased implant placement variability (CAN: \u00b1 0.47 mm, \u00b1 0.62 deg; PSI: \u00b1 0.63 mm, \u00b1 1.03 deg; SRG: \u00b1 0.73 mm, \u00b1 1.21 deg).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>In this laboratory-based TAA study, we found that both CAN and PSI demonstrated advantages over SRG instrumentation regarding implant placement accuracy. Tibial resections were found to be overall most accurate under CAN guidance, and talar resections were found to be overall most accurate under PSI guidance. In addition, the observed reduction in implant placement variability has potential positive implications for surgeons. However, as this study was conducted on artificial specimens, effects of soft tissue and preoperative deformities or pathologies were not considered. Future studies should include cadaveric specimens with various pathologies to better simulate conditions encountered in an operating room.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Level of Evidence:<\/jats:title>\n                    <jats:p>Level II \u2013 Lesser Quality RCT or Prospective Comparative Study.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.5435\/jaaos-d-26-00134","type":"journal-article","created":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T17:00:46Z","timestamp":1788282046000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Accuracy and Precision of Computer-assisted Navigation Compared With Patient-Specific Instrumentation and Conventional Methods in Total Ankle Arthroplasty"],"prefix":"10.5435","author":[{"ORCID":"https:\/\/orcid.org\/0009-0007-9373-8766","authenticated-orcid":false,"given":"Cole","family":"Herbel","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ramiro","family":"Lopez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matt","family":"Rueff","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zachary","family":"Tupper","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cyril","family":"Hamad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6198-9233","authenticated-orcid":false,"given":"Edward T.","family":"Haupt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,9,1]]},"reference":[{"key":"R1-20260901","doi-asserted-by":"crossref","first-page":"996","DOI":"10.1053\/j.jfas.2023.06.009","article-title":"Ankle distraction arthroplasty: A survivorship review and meta-analysis","volume":"62","author":"Ghasemi","year":"2023","journal-title":"J Foot Ankle Surg"},{"key":"R2-20260901","doi-asserted-by":"crossref","first-page":"102537","DOI":"10.1016\/j.jcot.2024.102537","article-title":"Current concepts in ankle arthrodesis","volume":"56","author":"Puri","year":"2024","journal-title":"J Clin Orthopaedics Trauma"},{"key":"R3-20260901","doi-asserted-by":"crossref","first-page":"699","DOI":"10.3113\/FAI.2012.0699","article-title":"Functional outcomes after ankle arthrodesis in elderly patients","volume":"33","author":"Strasser","year":"2012","journal-title":"Foot Ankle Int"},{"key":"R4-20260901","doi-asserted-by":"crossref","first-page":"24730114251329051","DOI":"10.1177\/24730114251329051","article-title":"Association of adjunctive procedures, patient demographics, or intraoperative factors and the risk of complications or reoperation following total ankle arthroplasty or ankle arthrodesis","volume":"10","author":"Lopez","year":"2025","journal-title":"Foot Ankle Orthop"},{"key":"R5-20260901","doi-asserted-by":"crossref","first-page":"952","DOI":"10.1177\/1071100717709566","article-title":"Supramalleolar osteotomy for tibial component malposition in total ankle replacement","volume":"38","author":"Deforth","year":"2017","journal-title":"Foot Ankle Int"},{"key":"R6-20260901","doi-asserted-by":"crossref","first-page":"1179","DOI":"10.2106\/JBJS.I.00287","article-title":"Misalignment of total ankle components can induce high joint contact pressures","volume":"92","author":"Espinosa","year":"2010","journal-title":"J Bone Joint Surg Am volume"},{"key":"R7-20260901","doi-asserted-by":"crossref","first-page":"1361","DOI":"10.1007\/s00402-014-2067-8","article-title":"Failure modes for total ankle arthroplasty: A statistical analysis of the Norwegian arthroplasty register","volume":"134","author":"Sadoghi","year":"2014","journal-title":"Arch Orthop Trauma Surg"},{"key":"R8-20260901","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1177\/1071100720949852","article-title":"Patient-reported outcome measures and radiological outcomes in mobile-bearing total ankle arthroplasty with varus or valgus deformity","volume":"42","author":"Allport","year":"2021","journal-title":"Foot Ankle Int"},{"key":"R9-20260901","doi-asserted-by":"crossref","first-page":"24730114251318735","DOI":"10.1177\/24730114251318735","article-title":"Does timing of hindfoot reconstruction before or after primary total knee arthroplasty impact reoperation rates?","volume":"10","author":"Dohse","year":"2025","journal-title":"Foot Ankle Orthop"},{"key":"R10-20260901","doi-asserted-by":"crossref","first-page":"1927","DOI":"10.2106\/JBJS.L.00404","article-title":"Differences in outcomes following total ankle replacement in patients with neutral alignment compared with tibiotalar joint malalignment","volume":"95","author":"Queen","year":"2013","journal-title":"J Bone Joint Surg Am volume"},{"key":"R11-20260901","doi-asserted-by":"crossref","first-page":"24730114211061493","DOI":"10.1177\/24730114211061493","article-title":"Accuracy of weightbearing CT scans for patient-specific instrumentation in total ankle arthroplasty","volume":"6","author":"Thompson","year":"2021","journal-title":"Foot Ankle Orthop"},{"key":"R12-20260901","doi-asserted-by":"crossref","first-page":"665","DOI":"10.1177\/1071100714531232","article-title":"Total ankle arthroplasty accuracy and reproducibility using preoperative CT scan-derived, patient-specific guides","volume":"35","author":"Berlet","year":"2014","journal-title":"Foot Ankle Int"},{"key":"R13-20260901","doi-asserted-by":"crossref","first-page":"1163","DOI":"10.1177\/1071100715585561","article-title":"Radiographic outcomes of preoperative CT scan\u2013derived patient-specific total ankle arthroplasty","volume":"36","author":"Hsu","year":"2015","journal-title":"Foot Ankle Int"},{"key":"R14-20260901","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1177\/19386400211068262","article-title":"Accuracy of CT-Derived patient-specific instrumentation for total ankle arthroplasty: The impact of the severity of preoperative varus ankle deformity","volume":"16","author":"Umbel","year":"2023","journal-title":"Foot Ankle Specialist"},{"key":"R15-20260901","doi-asserted-by":"crossref","first-page":"225","DOI":"10.4055\/cios.2015.7.2.225","article-title":"Evaluation of the accuracy and precision of a next generation computer-assisted surgical system","volume":"7","author":"Angibaud","year":"2015","journal-title":"Clin Orthop Surg"},{"key":"R16-20260901","doi-asserted-by":"crossref","first-page":"2257","DOI":"10.1016\/j.jse.2020.03.014","article-title":"Computer navigation leads to more accurate glenoid targeting during total shoulder arthroplasty compared with 3-dimensional preoperative planning alone","volume":"29","author":"Schoch","year":"2020","journal-title":"J Shoulder Elbow Surg"},{"key":"R17-20260901","doi-asserted-by":"crossref","first-page":"997","DOI":"10.1177\/1071100719849084","article-title":"Total ankle arthroplasty survival and risk factors for failure","volume":"40","author":"Escudero","year":"2019","journal-title":"Foot Ankle Int"},{"key":"R18-20260901","doi-asserted-by":"crossref","first-page":"412","DOI":"10.1177\/1071100716682086","article-title":"Accuracy and reproducibility using patient-specific instrumentation in total ankle arthroplasty","volume":"38","author":"Daigre","year":"2016","journal-title":"Foot Ankle Int"},{"key":"R19-20260901","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1016\/j.fas.2018.02.008","article-title":"Accuracy of patient-specific instrumentation in total ankle arthroplasty: A comparative study","volume":"25","author":"Saito","year":"2019","journal-title":"Foot Ankle Surg"},{"key":"R20-20260901","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1016\/j.fcl.2017.01.011","article-title":"Experience with navigation in total ankle arthroplasty. Is it worth the cost?","volume":"22","author":"Reb","year":"2017","journal-title":"Foot Ankle Clin"},{"key":"R21-20260901","doi-asserted-by":"crossref","first-page":"1043","DOI":"10.1302\/0301-620X.98B8.37240","article-title":"Component alignment and clinical outcome following total knee arthroplasty: A randomised controlled trial comparing an intramedullary alignment system with patient-specific instrumentation","volume":"98-B","author":"Huijbregts","year":"2016","journal-title":"Bone Joint J"},{"key":"R22-20260901","doi-asserted-by":"crossref","first-page":"1112147","DOI":"10.3389\/fsurg.2023.1112147","article-title":"Comparison of navigation systems for total knee arthroplasty: A systematic review and meta-analysis","volume":"10","author":"Luan","year":"2023","journal-title":"Front Surg"},{"key":"R23-20260901","doi-asserted-by":"crossref","first-page":"635","DOI":"10.2106\/JBJS.M.01496","article-title":"Computer navigation for total knee arthroplasty reduces revision rate for patients less than sixty-five years of age","volume":"97","author":"de Steiger","year":"2015","journal-title":"J bone joint Surg Am volume"},{"key":"R24-20260901","doi-asserted-by":"crossref","first-page":"2105","DOI":"10.1097\/CORR.0000000000001324","article-title":"Are there differences in accuracy or outcomes scores among navigated, robotic, patient-specific instruments or standard cutting guides in TKA? A network meta-analysis","volume":"478","author":"Bouch\u00e9","year":"2020","journal-title":"Clin Orthop Relat Res"},{"key":"R25-20260901","doi-asserted-by":"crossref","first-page":"e18083","DOI":"10.1097\/MD.0000000000018083","article-title":"Comparison of computer-assisted navigation and conventional instrumentation for bilateral total knee arthroplasty","volume":"98","author":"Hsu","year":"2019","journal-title":"Medicine (Baltimore)"},{"key":"R26-20260901","first-page":"e21.00200","article-title":"Comparison of surgical time, short-term adverse events, and implant placement accuracy between manual, robotic-assisted, and computer-navigated total hip arthroplasty: A network meta-analysis of randomized controlled trials","volume":"6","author":"Kunze","year":"2022","journal-title":"J Am Acad Orthop Surg Glob Res Rev"},{"key":"R27-20260901","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1186\/s42836-021-00100-9","article-title":"After 25 years of computer-navigated total knee arthroplasty, where do we stand today?","volume":"3","author":"Shah","year":"2021","journal-title":"Arthroplasty"},{"key":"R28-20260901","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1007\/s10195-012-0205-z","article-title":"Is computer-assisted total knee replacement for beginners or experts? Prospective study among three groups of patients treated by surgeons with different levels of experience","volume":"13","author":"Confalonieri","year":"2012","journal-title":"J Orthop Traumatol"},{"key":"R29-20260901","doi-asserted-by":"crossref","first-page":"014504","DOI":"10.1115\/1.4049545","article-title":"Application-specific learning curve with a modern computer-assisted orthopedic surgery system for joint arthroplasty","volume":"15","author":"Dai","year":"2021","journal-title":"J Med Devices"},{"key":"R30-20260901","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1016\/j.artd.2019.01.002","article-title":"Trends in computer navigation and robotic assistance for total knee arthroplasty in the United States: An analysis of patient and hospital factors","volume":"5","author":"Antonios","year":"2019","journal-title":"Arthroplasty Today"},{"key":"R31-20260901","doi-asserted-by":"crossref","first-page":"184","DOI":"10.3390\/jpm12020184","article-title":"Comparative cost analysis of four different computer-assisted technologies to implant a total knee arthroplasty over conventional instrumentation","volume":"12","author":"Christen","year":"2022","journal-title":"J Pers Med"}],"container-title":["Journal of the American Academy of Orthopaedic Surgeons"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-26-00134","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T17:00:51Z","timestamp":1788282051000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.5435\/JAAOS-D-26-00134"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,1]]},"references-count":31,"URL":"https:\/\/doi.org\/10.5435\/jaaos-d-26-00134","relation":{},"ISSN":["1067-151X","1940-5480"],"issn-type":[{"value":"1067-151X","type":"print"},{"value":"1940-5480","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,1]]},"assertion":[{"value":"2026-01-29","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-07-16","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}