{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T10:28:59Z","timestamp":1790159339825,"version":"4.1.0"},"reference-count":25,"publisher":"Korean Academy of Rehabilitation Medicine","issue":"4","license":[{"start":{"date-parts":[[2022,8,31]],"date-time":"2022-08-31T00:00:00Z","timestamp":1661904000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["e-arm.org"],"crossmark-restriction":true},"short-container-title":["Ann Rehabil Med"],"published-print":{"date-parts":[[2022,8,31]]},"abstract":"<jats:p>Objective To assess the accuracies and validities of popular smart bands for heart rate (HR) measurement in cardiovascular disease (CVD) patients during a graded exercise test (GXT).Methods Seventy-eight patients were randomly assigned to wear two different smart bands out of three possible choices: Samsung Galaxy Fit 2, Xiaomi Mi Band 5, or Partron PWB-250 on each wrist. A 12-lead exercise electrocardiogram (ECG) and patch-type single-lead ECG were used to assess the comparative HR accuracy of the smart bands. The HR was recorded during the GXT using the modified Bruce protocol.Results The concordance correlation coefficients (r&lt;sub&gt;c&lt;\/sub&gt;) were calculated to provide a measure of agreement between each device and the ECG. In all conditions, the Mi Band 5 and Galaxy Fit 2\u2019 correlations were r&lt;sub&gt;c&lt;\/sub&gt;&gt;0.90, while the PWB-250 correlation was r&lt;sub&gt;c&lt;\/sub&gt;=0.58 at rest. When evaluating the accuracy according to the magnitude of HR, all smart bands performed well (r&lt;sub&gt;c&lt;\/sub&gt;&gt;0.90) when the HR was below 100 but accuracy tended to decrease with higher HR values.Conclusion This study showed that the three smart bands had a high level of accuracy for HR measurements during low-intensity exercise. However, during moderate-intensity and high-intensity exercise, all the three smart bands performed less accurately. Further studies are needed to find a more optimal smart band for HR measurement that can be used for precise HR monitoring during formal cardiac rehabilitation exercise training, including at high and maximal intensity (Clinical Trial Registration No. cris.nih.go.kr\/KCT0007036).<\/jats:p>","DOI":"10.5535\/arm.22050","type":"journal-article","created":{"date-parts":[[2022,8,31]],"date-time":"2022-08-31T02:32:42Z","timestamp":1661913162000},"page":"209-218","update-policy":"https:\/\/doi.org\/10.5535\/crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Accuracy and Validity of Commercial Smart Bands for Heart Rate Measurements During Cardiopulmonary Exercise Test"],"prefix":"10.5535","volume":"46","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8223-2945","authenticated-orcid":true,"given":"Chul","family":"Kim","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3051-9287","authenticated-orcid":true,"given":"Seung Hyoun","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8623-7994","authenticated-orcid":true,"given":"Mi Rim","family":"Suh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"3481","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjmed.2004.01.009"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.7326\/0003-4819-143-9-200511010-00010"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1016\/j.tcm.2017.02.005"},{"key":"ref4","first-page":"2432","volume-title":"AHA\/ACCF secondary prevention and risk reduction therapy for patients with coronary and other atherosclerotic vascular disease: 2011 update: a guideline from the American Heart Association and American College of Cardiology Foundation endorsed by the World Heart Federation and the Preventive Cardiovascular Nurses Association","author":"Smith","year":"2011"},{"key":"ref5","first-page":"119","volume-title":"2017 ESC Guidelines for the management of acute myocardial infarction in patients presenting with ST-segment elevation: the Task Force for the management of acute myocardial infarction in patients presenting with ST-segment elevation of the European Society of Cardiology (ESC)","author":"Ibanez","year":"2018"},{"key":"ref6","volume-title":"","year":"2013"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1177\/2047487313501093"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.5535\/arm.2018.42.1.154"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.b5631"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijcard.2016.08.120"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1186\/1471-2261-13-82"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.3414\/me9112"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1007\/s12471-020-01432-y"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1249\/mss.0000000000001284"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.2196\/14707"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.21037\/cdt.2019.06.05"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.2196\/mhealth.7043"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1177\/2055207618770322"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.21037\/cdt.2019.04.08"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.2196\/11889"},{"key":"ref21","first-page":"78","volume-title":"Comparison of wearables for self-monitoring of heart rate in coronary rehabilitation patients","author":"Heyken","year":"2021"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.2007.121558"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.1161\/hc3901.095960"},{"key":"ref24","volume-title":"","author":"McBride","year":"2005"},{"key":"ref25","first-page":"1334","volume-title":"American College of Sports Medicine position stand: quantity and quality of exercise for developing and maintaining cardiorespiratory, musculoskeletal, and neuromotor fitness in apparently healthy adults: guidance for prescribing exercise","author":"Garber","year":"2011"}],"container-title":["Annals of Rehabilitation Medicine"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/e-arm.org\/upload\/pdf\/arm-22050.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/e-arm.org\/journal\/view.php?doi=10.5535\/arm.22050","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/e-arm.org\/upload\/pdf\/arm-22050.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,9,7]],"date-time":"2022-09-07T20:44:49Z","timestamp":1662583489000},"score":1,"resource":{"primary":{"URL":"http:\/\/e-arm.org\/journal\/view.php?doi=10.5535\/arm.22050"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,8,31]]},"references-count":25,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2022,8]]}},"URL":"https:\/\/doi.org\/10.5535\/arm.22050","relation":{},"ISSN":["2234-0645","2234-0653"],"issn-type":[{"value":"2234-0645","type":"print"},{"value":"2234-0653","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,8,31]]},"assertion":[{"value":"2022-05-04","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-07-01","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-08-31","order":2,"name":"published","label":"Published online","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-08-31","order":3,"name":"published","label":"Print publication","group":{"name":"publication_history","label":"Publication History"}}]}}