{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,14]],"date-time":"2025-05-14T13:43:44Z","timestamp":1747230224815,"version":"3.40.5"},"reference-count":15,"publisher":"Index Copernicus","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Otolaryngol Pol"],"published-print":{"date-parts":[[2024,4,9]]},"abstract":"<jats:p>&lt;b&gt;&lt;br&gt;Aim:&lt;\/b&gt; The aim of the study was to evaluate the results of electrical safety results of a prototype electromagnetic ear stimulation device in patients with tinnitus.&lt;\/br&gt; &lt;b&gt;&lt;br&gt;Material and methods:&lt;\/b&gt; The electrical safety tests of the prototype device for electro- and magnetostimulation of the hearing  organ were carried out at the Center for Attestation and Certification Tests in Gliwice. The tests concerned selected parameters including the PN-EN standard.&lt;\/br&gt; &lt;b&gt;&lt;br&gt;Results:&lt;\/b&gt; Safety studies of the prototype electrical stimulation device for the ear in patients with tinnitus were necessary to  perform the planned further preclinical studies. Obtained results regarding: identification and labeling of the device; protection against electric shock; checking protective earthing, functional earthing and potential equalization; checking the leakage current and auxiliary currents of the patient; checking the distances through the solid insulation and the use of thin  insulating spacers; checking the electrical strength of the device insulation; checking protection against mechanical hazards  of the device; checking the risk associated with surfaces, corners and edges, and checking the protection against excessive  temperatures and other threats comply with the standard PN-EN.&lt;\/br&gt; &lt;b&gt;&lt;br&gt;Conclusions:&lt;\/b&gt; No risk to the patient and medical staff. Tests of protection against mechanical hazards of the device have  shown that the only movable part whose contact with the patient could cause an unacceptable risk is the fan installed inside  the housing.&lt;\/br&gt;<\/jats:p>","DOI":"10.5604\/01.3001.0053.9036","type":"journal-article","created":{"date-parts":[[2024,2,23]],"date-time":"2024-02-23T15:05:05Z","timestamp":1708700705000},"page":"50-54","source":"Crossref","is-referenced-by-count":0,"title":["Electrical safety assessment of a prototype device for electromagnetic stimulation of the ear in patients with tinnitus"],"prefix":"10.5604","volume":"78","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8868-9679","authenticated-orcid":false,"given":"Jurek","family":"Olszewski","sequence":"first","affiliation":[{"name":"Clinic of Otolaryngology, Laryngological Oncology, Audiology and Phoniatrics at the 2nd Department of Otolaryngology of the Medical University of Lodz, Department of Polish Dialectology and Logopedics of the University of Lodz, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"3689","reference":[{"key":"612954r1","doi-asserted-by":"crossref","unstructured":"Portmann M., N\u00e8grevergne M., Aran J.M., Cazals Y.: Electrical stimulation of theear: clinical applications. Ann Otol Rhinol Laryngol., 1983; 92(6 Pt 1): 621\u2013622.","DOI":"10.1177\/000348948309200617"},{"key":"612954r2","doi-asserted-by":"crossref","unstructured":"Watanabe K., Okawara D., Baba S., Yagi T.: Electrocochleographic analysis ofthe suppression of tinnitus by electrical promontory stimulation. Audiology.,1997; 36(3): 147\u2013154.","DOI":"10.3109\/00206099709071968"},{"key":"612954r3","doi-asserted-by":"crossref","unstructured":"Dougall N., Maayan N., Soares-Weiser K., McDermott L.M., McIntosh A.:Transcranial magnetic stimulation (TMS) for schizophrenia. Cochrane Database Syst Rev., 2015; 20(8): CD006081.","DOI":"10.1002\/14651858.CD006081.pub2"},{"key":"612954r4","doi-asserted-by":"crossref","unstructured":"Nardone R., Tezzon F., H\u00f6ller Y. et al.: Transcranial magnetic stimulation(TMS)\/repetitive TMS in mild cognitive impairment and Alzheimer\u2019s disease. Acta Neurol Scand., 2014; 129(6): 351\u2013366.","DOI":"10.1111\/ane.12223"},{"key":"612954r5","doi-asserted-by":"crossref","unstructured":"Martin P.I., Treglia E., Naeser M.A. et al.: Language improvements after TMSplus modified CILT: Pilot, open-protocol study with two, chronic nonfluentaphasia cases. Restor Neurol Neurosci., 2014; 32(4): 483\u2013505.","DOI":"10.3233\/RNN-130365"},{"key":"612954r6","unstructured":"Olszewski J., Kowalski A., Mielczarek M.: The innovative generator of the magneticfield in tinnitus treatment. Am J Otolaryngol Head Neck Surg., 2018; 1(3): 1015."},{"key":"612954r7","doi-asserted-by":"crossref","unstructured":"Nore\u00f1a A.J., Mulders W.H., Robertson D.: Suppression of putative tinnitus--related activity by extra-cochlear electrical stimulation. J Neurophysiol.,2015; 113(1): 132\u2013143.","DOI":"10.1152\/jn.00580.2014"},{"key":"612954r8","doi-asserted-by":"crossref","unstructured":"Marks K.L., Martel D.T., Wu C. et al.: Auditory-somatosensory bimodal stimulation desynchronizes brain circuitry to reduce tinnitus in guinea pigs and humans.Sci Transl Med., 2018; 10(422): eaal3175. doi: 10.1126\/scitranslmed.aal3175.","DOI":"10.1126\/scitranslmed.aal3175"},{"key":"612954r9","doi-asserted-by":"crossref","unstructured":"Van Zwieten G., Janssen M.L.F., Smit J.V. et al.: Inhibition of experimental tinnitus with high frequency stimulation of the rat medial geniculate body. Neuromodulation., 2019; 22(4): 416\u2013424. doi: 10.1111\/ner.12795.","DOI":"10.1111\/ner.12795"},{"key":"612954r10","doi-asserted-by":"crossref","unstructured":"Zeng F.G., Djalilian H., Lin H.: Tinnitus treatment with precise and optimalelectric stimulation: opportunities and challenges. Curr Opin OtolaryngolHead Neck Surg., 2015; 23(5): 382\u2013387.","DOI":"10.1097\/MOO.0000000000000187"},{"key":"612954r11","doi-asserted-by":"crossref","unstructured":"Pollak T.A., Nicholson T.R., Edwards M.J., David A.S.: A systematic review oftranscranial magnetic stimulation in the treatment of functional (conversion)neurological symptoms. J Neurol Neurosurg Psychiatry., 2014; 85(2): 191\u2013197.","DOI":"10.1136\/jnnp-2012-304181"},{"key":"612954r12","doi-asserted-by":"crossref","unstructured":"Mielczarek M., Olszewski J.: Direct current stimulation of the ear in tinnitustreatment: a double-blind placebo-controlled study. Eur Arch Otorhinolaryngol., 2014; 271: 1815\u20131822.","DOI":"10.1007\/s00405-013-2849-6"},{"key":"612954r13","doi-asserted-by":"crossref","unstructured":"Olszewski J.: Evaluation the results of electromagnetic compatibility of a prototype device for ear stimulation in patients with tinnitus. Otolaryngol Pol.,2023; 77 (6) (zaakceptowana do publikacji).","DOI":"10.5604\/01.3001.0053.6157"},{"key":"612954r14","doi-asserted-by":"crossref","unstructured":"Olszewski J., Bieli\u0144ska M., Kowalski A.: Assessment of subjective tinnitus treatment results using a prototype device for electrical and magnetic stimulationof the ear- preliminary study. Life., 2022; 12(918): 1\u201310.","DOI":"10.3390\/life12060918"},{"key":"612954r15","doi-asserted-by":"crossref","unstructured":"Spencer S., Mielczarek M., Olszewski J. et al.: Effectiveness of bimodal auditory and electrical stimulation in patients with tinnitus: A feasibility study. FrontNeurosci., 2022; 16: 971633.","DOI":"10.3389\/fnins.2022.971633"}],"container-title":["Otolaryngologia Polska"],"original-title":[],"link":[{"URL":"https:\/\/otolaryngologypl.com\/gicid\/pdf\/01.3001.0053.9036","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/otolaryngologypl.com\/gicid\/pdf\/01.3001.0053.9036","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,4,16]],"date-time":"2024-04-16T09:43:21Z","timestamp":1713260601000},"score":1,"resource":{"primary":{"URL":"https:\/\/otolaryngologypl.com\/gicid\/01.3001.0053.9036"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,9]]},"references-count":15,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2024,4,9]]}},"URL":"https:\/\/doi.org\/10.5604\/01.3001.0053.9036","relation":{},"ISSN":["0030-6657","2300-8423"],"issn-type":[{"type":"print","value":"0030-6657"},{"type":"electronic","value":"2300-8423"}],"subject":[],"published":{"date-parts":[[2024,4,9]]}}}