{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T22:07:51Z","timestamp":1792620471312,"version":"4.5.0"},"reference-count":39,"publisher":"Editorial Committee of Annals of Thoracic and Cardiovascular Surgery","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["ATCS","Ann Thorac Cardiovasc Surg"],"published-print":{"date-parts":[[2017]]},"DOI":"10.5761\/atcs.oa.17-00045","type":"journal-article","created":{"date-parts":[[2017,7,17]],"date-time":"2017-07-17T22:08:06Z","timestamp":1500329286000},"page":"239-247","source":"Crossref","is-referenced-by-count":26,"title":["Glucose Variability Based on Continuous Glucose Monitoring Assessment Is Associated with Postoperative Complications after Cardiovascular Surgery"],"prefix":"10.5761","volume":"23","author":[{"given":"Hiroki","family":"Sato","sequence":"first","affiliation":[{"name":"Division of Thoracic and Cardiovascular Surgery, Niigata University Graduate School of Medical and Dental Science, Niigata, Niigata, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michihiro","family":"Hosojima","sequence":"additional","affiliation":[{"name":"Department of Clinical Nutrition Science, Niigata University Graduate School of Medical and Dental Science, Niigata, Niigata, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomomi","family":"Ishikawa","sequence":"additional","affiliation":[{"name":"Division of Nephrology and Rheumatology, Niigata University Graduate School of Medical and Dental Science, Niigata, Niigata, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenji","family":"Aoki","sequence":"additional","affiliation":[{"name":"Division of Thoracic and Cardiovascular Surgery, Niigata University Graduate School of Medical and Dental Science, Niigata, Niigata, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takeshi","family":"Okamoto","sequence":"additional","affiliation":[{"name":"Division of Thoracic and Cardiovascular Surgery, Niigata University Graduate School of Medical and Dental Science, Niigata, Niigata, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akihiko","family":"Saito","sequence":"additional","affiliation":[{"name":"Department of Applied Molecular Medicine, Niigata University Graduate School of Medical and Dental Science, Niigata, Niigata, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masanori","family":"Tsuchida","sequence":"additional","affiliation":[{"name":"Division of Thoracic and Cardiovascular Surgery, Niigata University Graduate School of Medical and Dental Science, Niigata, Niigata, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"3757","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1) Furnary AP, Wu Y, Bookin SO. Effect of hyperglycemia and continuous intravenous insulin infusions on outcomes of cardiac surgical procedures: the Portland Diabetic Project. Endocr Pract 2004; 10 Suppl 2: 21-33.","DOI":"10.4158\/EP.10.S2.21"},{"key":"2","doi-asserted-by":"crossref","unstructured":"2) Zerr KJ, Furnary AP, Grunkemeier GL, et al. Glucose control lowers the risk of wound infection in diabetics after open heart operations. Ann Thorac Surg 1997; 63: 356-61.","DOI":"10.1016\/S0003-4975(96)01044-2"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3) Kotagal M, Symons RG, Hirsch IB, et al. Perioperative hyperglycemia and risk of adverse events among patients with and without diabetes. Ann Surg 2015; 261: 97-103.","DOI":"10.1097\/SLA.0000000000000688"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4) Ascione R, Rogers CA, Rajakaruna C, et al. Inadequate blood glucose control is associated with in-hospital mortality and morbidity in diabetic and nondiabetic patients undergoing cardiac surgery. Circulation 2008; 118: 113-23.","DOI":"10.1161\/CIRCULATIONAHA.107.706416"},{"key":"5","doi-asserted-by":"crossref","unstructured":"5) Doenst T, Wijeysundera D, Karkouti K, et al. Hyperglycemia during cardiopulmonary bypass is an independent risk factor for mortality in patients undergoing cardiac surgery. J Thorac Cardiovasc Surg 2005; 130: 1144.","DOI":"10.1016\/j.jtcvs.2005.05.049"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6) Jones KW, Cain AS, Mitchell JH, et al. Hyperglycemia predicts mortality after CABG: postoperative hyperglycemia predicts dramatic increases in mortality after coronary artery bypass graft surgery. J Diabetes Complicat 2008; 22: 365-70.","DOI":"10.1016\/j.jdiacomp.2007.05.006"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7) van den Berghe G, Wouters P, Weekers F, et al. Intensive insulin therapy in critically ill patients. N Engl J Med 2001; 345: 1359-67.","DOI":"10.1056\/NEJMoa011300"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8) NICE-SUGAR Study Investigators, Finfer S, Chittock DR, et al. Intensive versus conventional glucose control in critically ill patients. N Engl J Med 2009; 360: 1283-97.","DOI":"10.1056\/NEJMoa0810625"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9) NICE-SUGAR Study Investigators, Finfer S, Liu B, et al. Hypoglycemia and risk of death in critically ill patients. N Engl J Med 2012; 367: 1108-18.","DOI":"10.1056\/NEJMoa1204942"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10) Ogawa S, Okawa Y, Sawada K, et al. Continuous postoperative insulin infusion reduces deep sternal wound infection in patients with diabetes undergoing coronary artery bypass grafting using bilateral internal mammary artery grafts: a propensity-matched analysis. Eur J Cardiothorac Surg 2016; 49: 420-6.","DOI":"10.1093\/ejcts\/ezv106"},{"key":"11","doi-asserted-by":"crossref","unstructured":"11) Tatsuishi W, Adachi H, Murata M, et al. Postoperative hyperglycemia and atrial fibrillation after coronary artery bypass graft surgery. Circ J 2015; 79: 112-8.","DOI":"10.1253\/circj.CJ-14-0989"},{"key":"12","doi-asserted-by":"crossref","unstructured":"12) Su G, Mi S, Tao H, et al. Association of glycemic variability and the presence and severity of coronary artery disease in patients with type 2 diabetes. Cardiovasc Diabetol 2011; 10: 19.","DOI":"10.1186\/1475-2840-10-19"},{"key":"13","doi-asserted-by":"crossref","unstructured":"13) Mendez CE, Mok KT, Ata A, et al. Increased glycemic variability is independently associated with length of stay and mortality in noncritically ill hospitalized patients. Diabetes Care 2013; 36: 4091-7.","DOI":"10.2337\/dc12-2430"},{"key":"14","doi-asserted-by":"crossref","unstructured":"14) Dossett LA, Cao H, Mowery NT, et al. Blood glucose variability is associated with mortality in the surgical intensive care unit. Am Surg 2008; 74: 679-85; discussion 685.","DOI":"10.1177\/000313480807400802"},{"key":"15","doi-asserted-by":"crossref","unstructured":"15) Egi M, Bellomo R, Stachowski E, et al. Variability of blood glucose concentration and short-term mortality in critically ill patients. Anesthesiology 2006; 105: 244-52.","DOI":"10.1097\/00000542-200608000-00006"},{"key":"16","doi-asserted-by":"crossref","unstructured":"16) Stamou SC, Nussbaum M, Carew JD, et al. Hypoglycemia with intensive insulin therapy after cardiac surgery: predisposing factors and association with mortality. J Thorac Cardiovasc Surg 2011; 142: 166-73.","DOI":"10.1016\/j.jtcvs.2010.09.064"},{"key":"17","doi-asserted-by":"crossref","unstructured":"17) Punke MA, Goepfert MS, Kluge S, et al. Perioperative glycemic control with a computerized algorithm versus conventional glycemic control in cardiac surgical patients undergoing cardiopulmonary bypass with blood cardioplegia. J Cardiothorac Vasc Anesth 2014; 28: 1273-7.","DOI":"10.1053\/j.jvca.2014.04.017"},{"key":"18","doi-asserted-by":"crossref","unstructured":"18) Lazar HL, McDonnell M, Chipkin SR, et al. The society of thoracic surgeons practice guideline series: Blood glucose management during adult cardiac surgery. Ann Thorac Surg 2009; 87: 663-9.","DOI":"10.1016\/j.athoracsur.2008.11.011"},{"key":"19","doi-asserted-by":"crossref","unstructured":"19) Keenan DB, Mastrototaro JJ, Voskanyan G, et al. Delays in minimally invasive continuous glucose monitoring devices: a review of current technology. J Diabetes Sci Technol 2009; 3: 1207-14.","DOI":"10.1177\/193229680900300528"},{"key":"20","doi-asserted-by":"crossref","unstructured":"20) Boom DT, Sechterberger MK, Rijkenberg S, et al. Insulin treatment guided by subcutaneous continuous glucose monitoring compared to frequent point-of-care measurement in critically ill patients: a randomized controlled trial. Crit Care 2014; 18: 453.","DOI":"10.1186\/s13054-014-0453-9"},{"key":"21","doi-asserted-by":"crossref","unstructured":"21) Schierenbeck F, Franco-Cereceda A, Liska J. Accuracy of 2 different continuous glucose monitoring systems in patients undergoing cardiac surgery. J Diabetes Sci Technol 2017; 11: 108-16.","DOI":"10.1177\/1932296816651632"},{"key":"22","doi-asserted-by":"crossref","unstructured":"22) Wilinska ME, Hovorka R. Glucose control in the intensive care unit by use of continuous glucose monitoring: what level of measurement error is acceptable? Clin Chem 2014; 60: 1500-9.","DOI":"10.1373\/clinchem.2014.225326"},{"key":"23","doi-asserted-by":"crossref","unstructured":"23) Aust H, Dinges G, Nardi-Hiebl S, et al. Feasibility and precision of subcutaneous continuous glucose monitoring in patients undergoing CABG surgery. J Cardiothorac Vasc Anesth 2014; 28: 1264-72.","DOI":"10.1053\/j.jvca.2014.02.022"},{"key":"24","doi-asserted-by":"crossref","unstructured":"24) Siegelaar SE, Barwari T, Hermanides J, et al. Microcirculation and its relation to continuous subcutaneous glucose sensor accuracy in cardiac surgery patients in the intensive care unit. J Thorac Cardiovasc Surg 2013; 146: 1283-9.","DOI":"10.1016\/j.jtcvs.2013.06.017"},{"key":"25","doi-asserted-by":"crossref","unstructured":"25) Holzinger U, Warszawska J, Kitzberger R, et al. Real-time continuous glucose monitoring in critically ill patients: a prospective randomized trial. Diabetes Care 2010; 33: 467-72.","DOI":"10.2337\/dc09-1352"},{"key":"26","doi-asserted-by":"crossref","unstructured":"26) Boyne MS, Silver DM, Kaplan J, et al. Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor. Diabetes 2003; 52: 2790-4.","DOI":"10.2337\/diabetes.52.11.2790"},{"key":"27","doi-asserted-by":"crossref","unstructured":"27) Rossetti P, Bondia J, Veh\u00ed J, et al. Estimating plasma glucose from interstitial glucose: the issue of calibration algorithms in commercial continuous glucose monitoring devices. Sensors (Basel) 2010; 10: 10936-52.","DOI":"10.3390\/s101210936"},{"key":"28","doi-asserted-by":"crossref","unstructured":"28) Jeon CY, Furuya EY, Berman MF, et al. The role of pre-operative and post-operative glucose control in surgical-site infections and mortality. PLoS ONE 2012; 7: e45616.","DOI":"10.1371\/journal.pone.0045616"},{"key":"29","doi-asserted-by":"crossref","unstructured":"29) Melduni RM, Schaff HV, Bailey KR, et al. Implications of new-onset atrial fibrillation after cardiac surgery on long-term prognosis: a community-based study. Am Heart J 2015; 170: 659-68.","DOI":"10.1016\/j.ahj.2015.06.015"},{"key":"30","doi-asserted-by":"crossref","unstructured":"30) Risnes I, Abdelnoor M, Almdahl SM, et al. Mediastinitis after coronary artery bypass grafting risk factors and long-term survival. Ann Thorac Surg 2010; 89: 1502-9.","DOI":"10.1016\/j.athoracsur.2010.02.038"},{"key":"31","doi-asserted-by":"crossref","unstructured":"31) Erdil N, Gedik E, Donmez K, et al. Predictors of postoperative atrial fibrillation after on-pump coronary artery bypass grafting: is duration of mechanical ventilation time a risk factor? Ann Thorac Cardiovasc Surg 2014; 20: 135-42.","DOI":"10.5761\/atcs.oa.12.02104"},{"key":"32","doi-asserted-by":"crossref","unstructured":"32) Wang M, Chen M, Ao H, et al. The effects of different BMI on blood loss and transfusions in Chinese patients undergoing coronary artery bypass grafting. Ann Thorac Cardiovasc Surg 2017; 23: 83-90.","DOI":"10.5761\/atcs.oa.16-00219"},{"key":"33","doi-asserted-by":"crossref","unstructured":"33) Sezai A, Shiono M. The role of \u03b2-blockers in cardiac perioperative management. Ann Thorac Cardiovasc Surg 2014; 20: 261-6.","DOI":"10.5761\/atcs.ed.13-00374"},{"key":"34","doi-asserted-by":"crossref","unstructured":"34) Nagaoka E, Arai H, Tamura K, et al. Prevention of atrial fibrillation with ultra-low dose landiolol after off-pump coronary artery bypass grafting. Ann Thorac Cardiovasc Surg 2014; 20: 129-34.","DOI":"10.5761\/atcs.oa.12.02003"},{"key":"35","doi-asserted-by":"crossref","unstructured":"35) Halkos ME, Puskas JD, Lattouf OM, et al. Elevated preoperative hemoglobin A1c level is predictive of adverse events after coronary artery bypass surgery. J Thorac Cardiovasc Surg 2008; 136: 631-40.","DOI":"10.1016\/j.jtcvs.2008.02.091"},{"key":"36","doi-asserted-by":"crossref","unstructured":"36) Tatsuishi W, Adachi H, Murata M, et al. Postoperative hyperglycemia and atrial fibrillation after coronary artery bypass graft surgery. Circ J 2015; 79: 112-8.","DOI":"10.1253\/circj.CJ-14-0989"},{"key":"37","doi-asserted-by":"crossref","unstructured":"37) Zhang Y, Han H, Wang J, et al. Impairment of human ether-\u00e1-go-go-related gene (HERG) K+ channel function by hypoglycemia and hyperglycemia. Similar phenotypes but different mechanisms. J Biol Chem 2003; 278: 10417-26.","DOI":"10.1074\/jbc.M211044200"},{"key":"38","doi-asserted-by":"crossref","unstructured":"38) Umpierrez GE, Smiley D, Jacobs S, et al. Randomized study of basal-bolus insulin therapy in the inpatient management of patients with type 2 diabetes undergoing general surgery (RABBIT 2 surgery). Diabetes Care 2011; 34: 256-61.","DOI":"10.2337\/dc10-1407"},{"key":"39","doi-asserted-by":"crossref","unstructured":"39) Polonsky WH, Peters AL, Hessler D. The Impact of Real-Time Continuous Glucose Monitoring in Patients 65 Years and Older. J Diabetes Sci Technol 2016; 10: 892-7.","DOI":"10.1177\/1932296816643542"}],"container-title":["Annals of Thoracic and Cardiovascular Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/atcs\/23\/5\/23_oa.17-00045\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,10,12]],"date-time":"2020-10-12T19:55:37Z","timestamp":1602532537000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/atcs\/23\/5\/23_oa.17-00045\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017]]},"references-count":39,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.5761\/atcs.oa.17-00045","relation":{},"ISSN":["1341-1098","2186-1005"],"issn-type":[{"value":"1341-1098","type":"print"},{"value":"2186-1005","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017]]}}}