{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,16]],"date-time":"2026-11-16T05:18:41Z","timestamp":1794806321874,"version":"4.9.1"},"reference-count":31,"publisher":"Archives of Pathology and Laboratory Medicine","issue":"12","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,12]]},"abstract":"<jats:sec>\n                    <jats:title>Context.\u2014<\/jats:title>\n                    <jats:p>Transporting specimens can expose them to uncontrolled environmental factors. Whole blood viability is a commonly used preanalytic marker of quality for analysis of white blood cells.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objective.\u2014<\/jats:title>\n                    <jats:p>To evaluate whole blood viability as a marker for transportation and specimen integrity for lymphocyte subset evaluation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design.\u2014<\/jats:title>\n                    <jats:p>More than 9000 whole blood specimens, transported during a 4-year period, and their lymphocyte subset evaluation results were analyzed retrospectively. Viability was measured by using the Cellaca MX imaging cytometer, and lymphocyte and lymphocyte subset counts were determined with flow cytometry. Specimen cell viability results were stratified based on different transportation factors to discern their potential effects. Lymphocyte subset evaluation results from specimens with lower viability were compared with those from optimal viability specimens.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results.\u2014<\/jats:title>\n                    <jats:p>\n                      Cell viability of transported specimens exhibited seasonal variation, decreasing during the warm summer months (median, 77.0% versus 83.4% in other seasons). The decline in viability negatively correlated with ambient temperature during transportation (\n                      <jats:italic>r<\/jats:italic>\n                      = \u22120.7876). Longer transportation time (&gt;60 hours) also caused a decrease in viability (median, 64.0%). While we observed a decrease in absolute cell counts for CD45\n                      <jats:sup>+<\/jats:sup>\n                      lymphocytes, CD3\n                      <jats:sup>+<\/jats:sup>\n                      T cells, CD8\n                      <jats:sup>+<\/jats:sup>\n                      T cells, and CD19\n                      <jats:sup>+<\/jats:sup>\n                      B cells in specimens with low viability (50%\u201380%), the differences were well within the assay\u2019s total allowable error.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions.\u2014<\/jats:title>\n                    <jats:p>Control of preanalytic factors is critical for laboratory testing. Whole blood viability is a sensitive indicator of transport conditions and time, but it is not a specific predictor of quality for the main lymphocyte populations in cellular immunology testing.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.5858\/arpa.2026-0046-oa","type":"journal-article","created":{"date-parts":[[2026,8,8]],"date-time":"2026-08-08T02:47:49Z","timestamp":1786157269000},"page":"956-962","source":"Crossref","is-referenced-by-count":1,"title":["Cellular Viability of Whole Blood Specimens Is a Sensitive Indicator of Transport Conditions"],"prefix":"10.5858","volume":"150","author":[{"given":"Scott M.","family":"Ennis","sequence":"first","affiliation":[{"name":"From the Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, Minnesota"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yifei K.","family":"Yang","sequence":"additional","affiliation":[{"name":"From the Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, Minnesota"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amir A.","family":"Sadighi Akha","sequence":"additional","affiliation":[{"name":"From the Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, Minnesota"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Attila","family":"Kum\u00e1novics","sequence":"additional","affiliation":[{"name":"From the Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, Minnesota"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"3906","reference":[{"issue":"7","key":"i1543-2165-150-12-956-b01","series-title":"Clin Chem","first-page":"1338","article-title":"Errors in a stat laboratory: types and frequencies 10 years later","volume":"53","author":"Carraro","year":"2007","unstructured":"Carraro P,Plebani M. Errors in a stat laboratory: types and frequencies 10 years later. Clin Chem. 2007;53(7):1338\u20131342. doi:10.1373\/clinchem.2007.088344"},{"issue":"3","key":"i1543-2165-150-12-956-b02","series-title":"Clin Chem Lab Med","first-page":"357","article-title":"Preanalytical quality improvement: in pursuit of harmony, on behalf of European Federation for Clinical Chemistry and Laboratory Medicine (EFLM) Working group for Preanalytical Phase (WG-PRE)","volume":"53","author":"Lippi","year":"2015","unstructured":"Lippi G,Banfi G,Church S, et al. Preanalytical quality improvement: in pursuit of harmony, on behalf of European Federation for Clinical Chemistry and Laboratory Medicine (EFLM) Working group for Preanalytical Phase (WG-PRE). Clin Chem Lab Med. 2015;53(3):357\u2013370. doi:10.1515\/cclm-2014-1051"},{"key":"i1543-2165-150-12-956-b03","article-title":"PRE04 Handling, Transport, Processing, and Storage of Blood Specimens for Routine Laboratory Examinations","author":"Clinical and Laboratory Standards Institute","year":"2023","unstructured":"Clinical and Laboratory Standards Institute. PRE04 Handling, Transport, Processing, and Storage of Blood Specimens for Routine Laboratory Examinations. Clinical and Laboratory Standards Institute; 2023."},{"issue":"6","key":"i1543-2165-150-12-956-b04","series-title":"Clin Chem Lab Med","first-page":"1047","article-title":"How to meet ISO15189:2012 pre-analytical requirements in clinical laboratories: a consensus document by the EFLM WG-PRE","volume":"59","author":"Vermeersch","year":"2021","unstructured":"Vermeersch P,Frans G,von Meyer A,Costelloe S,Lippi G,Simundic AM. How to meet ISO15189:2012 pre-analytical requirements in clinical laboratories: a consensus document by the EFLM WG-PRE. Clin Chem Lab Med. 2021;59(6):1047\u20131061. doi:10.1515\/cclm-2020-1859"},{"key":"i1543-2165-150-12-956-b05","article-title":"CAP Checklist: Laboratory General","author":"College of American Pathologists","year":"2024","unstructured":"College of American Pathologists. CAP Checklist: Laboratory General. College of American Pathologists; 2024."},{"key":"i1543-2165-150-12-956-b06","series-title":"Clin Biochem","first-page":"3","article-title":"Hematology and coagulation preanalytics for clinical chemists: factors intrinsic to the sample and extrinsic to the patient","volume":"115","author":"Winter","year":"2023","unstructured":"Winter WE,Pittman DL,Harris NS. Hematology and coagulation preanalytics for clinical chemists: factors intrinsic to the sample and extrinsic to the patient. Clin Biochem. 2023;115:3\u201312. doi:10.1016\/j.clinbiochem.2022.11.012"},{"issue":"9","key":"i1543-2165-150-12-956-b07","series-title":"J Clin Pathol","first-page":"772","article-title":"Pseudopyropoikilocytosis: a striking artefact","volume":"49","author":"Bain","year":"1996","unstructured":"Bain BJ,Liesner R. Pseudopyropoikilocytosis: a striking artefact. J Clin Pathol. 1996;49(9):772\u2013773. doi:10.1136\/jcp.49.9.772"},{"issue":"suppl 1","key":"i1543-2165-150-12-956-b08","series-title":"Int J Lab Hematol","first-page":"170","article-title":"Pre- and postanalytical errors in haematology","volume":"41","author":"De la Salle","year":"2019","unstructured":"De la Salle B. Pre- and postanalytical errors in haematology. Int J Lab Hematol. 2019;41(suppl 1):170\u2013176. doi:10.1111\/ijlh.13007"},{"issue":"3","key":"i1543-2165-150-12-956-b09","series-title":"Arch Pathol Lab Med","first-page":"336","article-title":"Changes in automated complete blood cell count and differential leukocyte count results induced by storage of blood at room temperature","volume":"126","author":"Gulati","year":"2002","unstructured":"Gulati GL,Hyland LJ,Kocher W,Schwarting R. Changes in automated complete blood cell count and differential leukocyte count results induced by storage of blood at room temperature. Arch Pathol Lab Med. 2002;126(3):336\u2013342. doi:10.5858\/2002-126-0336-CIACBC"},{"key":"i1543-2165-150-12-956-b10","series-title":"J Immunol Methods","first-page":"113822","article-title":"Functional immunological assays","volume":"537","author":"Kumanovics","year":"2025","unstructured":"Kumanovics A,Askar M,Sadighi Akha AA. Functional immunological assays. J Immunol Methods. 2025;537:113822. doi:10.1016\/j.jim.2025.113822"},{"key":"i1543-2165-150-12-956-b11","series-title":"J Immunol Methods","first-page":"1","article-title":"Recommendations for the evaluation of specimen stability for flow cytometric testing during drug development","volume":"418","author":"Brown","year":"2015","unstructured":"Brown L,Green CL,Jones N, et al. Recommendations for the evaluation of specimen stability for flow cytometric testing during drug development. J Immunol Methods. 2015;418:1\u20138. doi:10.1016\/j.jim.2015.01.008"},{"issue":"5","key":"i1543-2165-150-12-956-b12","series-title":"Cytometry B Clin Cytom","first-page":"286","article-title":"Validation of cell-based fluorescence assays: practice guidelines from the ICSH and ICCS\u2014part II\u2014preanalytical issues","volume":"84","author":"Davis","year":"2013","unstructured":"Davis BH,Dasgupta A,Kussick S,Han JY,Estrellado A; ICSH\/ICCS Working Group. Validation of cell-based fluorescence assays: practice guidelines from the ICSH and ICCS\u2014part II\u2014preanalytical issues. Cytometry B Clin Cytom. 2013;84(5):286\u2013290. doi:10.1002\/cyto.b.21105"},{"issue":"1","key":"i1543-2165-150-12-956-b13","series-title":"Cytometry B Clin Cytom","first-page":"1","article-title":"Impact of preanalytical variables on granulocytic surface antigen expression: a review","volume":"65","author":"Elghetany","year":"2005","unstructured":"Elghetany MT,Davis BH. Impact of preanalytical variables on granulocytic surface antigen expression: a review. Cytometry B Clin Cytom. 2005;65(1):1\u20135. doi:10.1002\/cyto.b.20051"},{"issue":"6","key":"i1543-2165-150-12-956-b14","series-title":"Transfusion","first-page":"1501","article-title":"Evaluation of peripheral blood stem cell quality in products transported by traditional courier or commercial overnight shipping services","volume":"54","author":"Howard","year":"2014","unstructured":"Howard A,Chitphakdithai P,Waller EK, et al. Evaluation of peripheral blood stem cell quality in products transported by traditional courier or commercial overnight shipping services. Transfusion. 2014;54(6):1501\u20131507. doi:10.1111\/trf.12533"},{"issue":"2","key":"i1543-2165-150-12-956-b15","series-title":"Biosci Rep","first-page":"BSR20203827","article-title":"Effects of storage time and temperature on highly multiparametric flow analysis of peripheral blood samples; implications for clinical trial samples","volume":"41","author":"Jerram","year":"2021","unstructured":"Jerram A,Guy TV,Beutler L, et al. Effects of storage time and temperature on highly multiparametric flow analysis of peripheral blood samples; implications for clinical trial samples. Biosci Rep. 2021;41(2):BSR20203827. doi:10.1042\/BSR20203827"},{"key":"i1543-2165-150-12-956-b16","series-title":"J Transl Med","first-page":"26","article-title":"Shipping blood to a central laboratory in multicenter clinical trials: effect of ambient temperature on specimen temperature, and effects of temperature on mononuclear cell yield, viability and immunologic function","volume":"9","author":"Olson","year":"2011","unstructured":"Olson WC,Smolkin ME,Farris EM, et al. Shipping blood to a central laboratory in multicenter clinical trials: effect of ambient temperature on specimen temperature, and effects of temperature on mononuclear cell yield, viability and immunologic function. J Transl Med. 2011;9:26. doi:10.1186\/1479-5876-9-26"},{"issue":"17","key":"i1543-2165-150-12-956-b17","series-title":"Int J Mol Sci","first-page":"13479","article-title":"Influence of pre-analytic conditions on quantity of lymphocytes","volume":"24","author":"Proschmann","year":"2023","unstructured":"Proschmann U,Shalchi Amirkhiz P,Andres P, et al. Influence of pre-analytic conditions on quantity of lymphocytes. Int J Mol Sci. 2023;24(17):13479. doi:10.3390\/ijms241713479"},{"issue":"3","key":"i1543-2165-150-12-956-b18","series-title":"Cancers (Basel)","first-page":"473","article-title":"Impact of pre-analytical and analytical variables associated with sample preparation on flow cytometric stainings obtained with EuroFlow panels","volume":"14","author":"Sedek","year":"2022","unstructured":"Sedek L,Flores-Montero J,van der Sluijs A, et al. Impact of pre-analytical and analytical variables associated with sample preparation on flow cytometric stainings obtained with EuroFlow panels. Cancers (Basel). 2022;14(3):473. doi:10.3390\/cancers14030473"},{"key":"i1543-2165-150-12-956-b19","author":"Clinical Laboratory Standard of Practice: Cellular Immunology","year":"2020","unstructured":"Clinical Laboratory Standard of Practice: Cellular Immunology. New York State Department of Health. 2020. https:\/\/www.wadsworth.org\/regulatory\/clep\/clinical-labs\/laboratory-standards. Accessed April 20, 2026."},{"key":"i1543-2165-150-12-956-b20","article-title":"Climate Data Online |Data Tools |Local Climatological Data (LCD) National Centers for Environmental Information","unstructured":"Climate Data Online |Data Tools |Local Climatological Data (LCD) National Centers for Environmental Information. https:\/\/www.ncdc.noaa.gov\/cdo-web\/datatools\/lcd. Accessed January 1, 2025."},{"key":"i1543-2165-150-12-956-b21","article-title":"Mayo Clinic Laboratories","author":"United States Shipping Guides","unstructured":"United States Shipping Guides. Mayo Clinic Laboratories. https:\/\/www.mayocliniclabs.com\/-\/media\/it-mmfiles\/Special-Instructions\/6\/5\/2\/united-states-shipping-guide. Accessed May 1, 2025."},{"key":"i1543-2165-150-12-956-b22","article-title":"T, B, and Natural Killer (NK) Cells, Blood","author":"Mayo Clinic Laboratories: Quantitative Lymphocyte Subsets","unstructured":"Mayo Clinic Laboratories: Quantitative Lymphocyte Subsets: T, B, and Natural Killer (NK) Cells, Blood. Mayo Clinic Laboratories. https:\/\/www.mayocliniclabs.com\/test-catalog\/overview\/9336. Accessed March 21, 2026."},{"key":"i1543-2165-150-12-956-b23","article-title":"Mayo Clinic Laboratories: CD4 Count for Immune Monitoring, Blood","unstructured":"Mayo Clinic Laboratories: CD4 Count for Immune Monitoring, Blood. https:\/\/www.mayocliniclabs.com\/test-catalog\/overview\/84348. Accessed March 20, 2026."},{"issue":"2","key":"i1543-2165-150-12-956-b24","series-title":"Cytometry","first-page":"53","article-title":"Selection of lymphocyte gating protocol has an impact on the level of reliability of T-cell subsets in aging specimens","volume":"50","author":"Bergeron","year":"2002","unstructured":"Bergeron M,Nicholson JK,Phaneuf S, et al. Selection of lymphocyte gating protocol has an impact on the level of reliability of T-cell subsets in aging specimens. Cytometry. 2002;50(2):53\u201361. doi:10.1002\/cyto.10092"},{"issue":"1","key":"i1543-2165-150-12-956-b25","series-title":"J Immunol Methods","first-page":"29","article-title":"Comparison of T and B cell analyses on fresh and aged blood","volume":"73","author":"Nicholson","year":"1984","unstructured":"Nicholson JK,Jones BM,Cross GD,McDougal JS. Comparison of T and B cell analyses on fresh and aged blood. J Immunol Methods. 1984;73(1):29\u201340. doi:10.1016\/0022-1759(84)90028-0"},{"key":"i1543-2165-150-12-956-b26","article-title":"R: a language and environment for statistical computing","unstructured":"R: a language and environment for statistical computing. R Foundation for Statistical Computing. https:\/\/www.R-project.org\/. Accessed June 1, 2025."},{"key":"i1543-2165-150-12-956-b27","article-title":"HHS Panel on Antiretroviral Guidelines for Adults and Adolescents\u2014A Working Group of the Office of AIDS Research Advisory Council (OARAC)","unstructured":"HHS Panel on Antiretroviral Guidelines for Adults and Adolescents\u2014A Working Group of the Office of AIDS Research Advisory Council (OARAC). https:\/\/www.ncbi.nlm.nih.gov\/books\/NBK586306\/. Updated September 25, 2025. Accessed March 20, 2026."},{"key":"i1543-2165-150-12-956-b28","series-title":"Clin Biochem","first-page":"13","article-title":"The impact of environmental factors on external and internal specimen transport","volume":"115","author":"Pierre","year":"2023","unstructured":"Pierre CC,Wiencek JR. The impact of environmental factors on external and internal specimen transport. Clin Biochem. 2023;115:13\u201321. doi:10.1016\/j.clinbiochem.2022.11.005"},{"key":"i1543-2165-150-12-956-b29","series-title":"Clin Chim Acta","first-page":"110","article-title":"Big data analysis reveals the existence of seasonal pseudohyperkalaemia even in temperate climates","volume":"497","author":"Rampul","year":"2019","unstructured":"Rampul A,Nowrungsah D,Madurai S,Pillay TS. Big data analysis reveals the existence of seasonal pseudohyperkalaemia even in temperate climates. Clin Chim Acta. 2019;497:110\u2013113. doi:10.1016\/j.cca.2019.07.021"},{"issue":"5","key":"i1543-2165-150-12-956-b30","series-title":"J Appl Lab Med","first-page":"1002","article-title":"Global heatwaves threaten integrity of patient test results: a dire warning for the lab medicine community","volume":"8","author":"Hart","year":"2023","unstructured":"Hart S,Wiencek JR. Global heatwaves threaten integrity of patient test results: a dire warning for the lab medicine community. J Appl Lab Med. 2023;8(5):1002\u20131005. doi:10.1093\/jalm\/jfad040"},{"issue":"6","key":"i1543-2165-150-12-956-b31","series-title":"J Appl Lab Med","first-page":"973","article-title":"Impact of ambient seasonal temperature on specimens stored in courier lockboxes","volume":"2","author":"Wiencek","year":"2018","unstructured":"Wiencek JR,Nichols JH. Impact of ambient seasonal temperature on specimens stored in courier lockboxes. J Appl Lab Med. 2018;2(6):973\u2013976. doi:10.1373\/jalm.2017.025247"}],"container-title":["Archives of Pathology &amp; Laboratory Medicine"],"original-title":[],"link":[{"URL":"https:\/\/aplm.kglmeridian.com\/view\/journals\/arpa\/150\/12\/article-p956.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aplm.kglmeridian.com\/downloadpdf\/journals\/arpa\/150\/12\/article-p956.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/aplm.kglmeridian.com\/downloadpdf\/journals\/arpa\/150\/12\/article-p956.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,11,16]],"date-time":"2026-11-16T04:28:39Z","timestamp":1794803319000},"score":1,"resource":{"primary":{"URL":"https:\/\/aplm.kglmeridian.com\/view\/journals\/arpa\/150\/12\/article-p956.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,12]]},"references-count":31,"journal-issue":{"issue":"12"},"URL":"https:\/\/doi.org\/10.5858\/arpa.2026-0046-oa","relation":{},"ISSN":["1543-2165","0003-9985"],"issn-type":[{"value":"1543-2165","type":"electronic"},{"value":"0003-9985","type":"print"}],"subject":[],"published":{"date-parts":[[2026,12]]}}}