{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,18]],"date-time":"2026-01-18T02:11:27Z","timestamp":1768702287666,"version":"3.49.0"},"reference-count":62,"publisher":"Wiley","issue":"11","license":[{"start":{"date-parts":[[2017,11,1]],"date-time":"2017-11-01T00:00:00Z","timestamp":1509494400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"DOI":"10.13039\/100008102","name":"University of Cincinnati","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100008102","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal AWWA"],"published-print":{"date-parts":[[2017,11]]},"abstract":"<jats:p>US corrosion control practice often assumes that the orthophosphate component of blended phosphate corrosion inhibitors causes the formation of low\u2010solubility lead\u2013orthophosphate solids that control lead release into drinking water. This study identified the solids that formed on the interior surface of a lead service line and a galvanized steel pipe excavated from a system using a proprietary blended phosphate chemical. The scale was analyzed by X\u2010ray diffraction, X\u2010ray fluorescence, and scanning electron microscopy\/energy dispersive spectroscopy. Instead of crystalline lead\u2013orthophosphate solids, a porous amorphous layer rich in aluminum, calcium, phosphorus, and lead was observed at the lead pipe scale\u2013water interface. Thus, the mechanism inhibiting lead release into the water was not a thermodynamically predictable passivating lead\u2013orthophosphate scale, but rather an amorphous barrier deposit that was possibly vulnerable to disturbances. Galvanized pipe scales showed relatively crystalline iron and zinc compounds, with additional surface deposition of aluminum, phosphorus, calcium, and lead.<\/jats:p>","DOI":"10.5942\/jawwa.2017.109.0121","type":"journal-article","created":{"date-parts":[[2017,6,23]],"date-time":"2017-06-23T19:14:42Z","timestamp":1498245282000},"source":"Crossref","is-referenced-by-count":53,"title":["Scale Formation Under Blended Phosphate Treatment for a Utility With Lead Pipes"],"prefix":"10.1002","volume":"109","author":[{"given":"Lauren W.","family":"Wasserstrom","sequence":"first","affiliation":[{"name":"AWWA  Denver Colo."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stephanie A.","family":"Miller","sequence":"additional","affiliation":[{"name":"Trinity Consultants  Westerville Ohio"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Simoni","family":"Triantafyllidou","sequence":"additional","affiliation":[{"name":"US Environmental Protection Agency (USEPA), Office of Research and Development National Risk Management Research Laboratory  Cincinnati Ohio"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael K.","family":"Desantis","sequence":"additional","affiliation":[{"name":"Oakridge Institute for Science and Education, hosted at USEPA, Office of Research and Development National Risk Management Research Laboratory  Cincinnati Ohio"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael R.","family":"Schock","sequence":"additional","affiliation":[{"name":"US Environmental Protection Agency (USEPA), Office of Research and Development National Risk Management Research Laboratory  Cincinnati Ohio"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2017,11]]},"reference":[{"key":"e_1_2_9_2_1","volume-title":"Internal Corrosion of Water Distribution Systems","author":"AWWARF (AWWA Research Foundation) & DVGW\u2010TZW (Technologiezentrum Wasser)","year":"1996"},{"key":"e_1_2_9_3_1","volume-title":"Lead Control Strategies","author":"AWWARF","year":"1990"},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.5006\/1.3580857"},{"key":"e_1_2_9_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.scitotenv.2011.10.048"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.5006\/1.3585211"},{"issue":"5","key":"e_1_2_9_7_1","first-page":"192","article-title":"Mental Health Effects of Lead on Children","volume":"7","author":"Bryce\u2010Smith D.","year":"1978","journal-title":"Ambio,"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.1002\/j.1551-8833.2000.tb08820.x"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.corsci.2008.06.007"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.2166\/wh.2009.015"},{"key":"e_1_2_9_11_1","unstructured":"CDC (Centers for Disease Control and Prevention) 2012.What Do Parents Need to Know to Protect Their Children?www.cdc.gov\/nceh\/lead\/acclpp\/blood_lead_levels.htm(accessed February 2017)."},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.1089\/ees.2015.0073"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.1021\/es501342j"},{"key":"e_1_2_9_14_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1747-6593.1992.tb00750.x"},{"key":"e_1_2_9_15_1","doi-asserted-by":"publisher","DOI":"10.5942\/jawwa.2016.108.0086"},{"key":"e_1_2_9_16_1","doi-asserted-by":"publisher","DOI":"10.2166\/wst.2004.0086"},{"key":"e_1_2_9_17_1","doi-asserted-by":"publisher","DOI":"10.1021\/es4003636"},{"key":"e_1_2_9_18_1","unstructured":"DeSantis M.K.&Schock M.R. 2014.Ground Truthing the \u2018Conventional Wisdom\u2019 of Lead Corrosion Control Using Mineralogical Analysis.Proc. AWWA 2014 Water Quality Technology Conference New Orleans."},{"key":"e_1_2_9_19_1","unstructured":"DeSantis M.K.;Schock M.R.; &Bennett\u2010Stamper C. 2012.Incorporation of Phosphate in Destabilized PbO2Scales Proc. AWWA 2012 Water Quality Technology Conference Toronto."},{"key":"e_1_2_9_20_1","unstructured":"e\u2010CFR (Electronic Code of Federal Regulations) 2017.National Primary Drinking Water Regulations. Title 40 Part 141 Subpart I Control of Lead and Copper.www.ecfr.gov\/cgi\u2010bin\/text\u2010idx?tpl=\/ecfrbrowse\/Title40\/40cfr141_main_02.tpl(accessed March 2017)."},{"key":"e_1_2_9_21_1","doi-asserted-by":"publisher","DOI":"10.1021\/es4034952"},{"key":"e_1_2_9_22_1","doi-asserted-by":"publisher","DOI":"10.1021\/es802789w"},{"key":"e_1_2_9_23_1","doi-asserted-by":"publisher","DOI":"10.1002\/j.1551-8833.2002.tb09383.x"},{"key":"e_1_2_9_24_1","unstructured":"Friedman R.M.;Cortez E.;Liu J.;Pacholec F.;Lechner J.B.; &Dwyer J.J. 1995.Analysis of Film Formation Using Phosphate Inhibitors in Systems With Various Water Qualities.Proc. AWWA 1995 Water Quality Technology Conference New Orleans."},{"key":"e_1_2_9_25_1","unstructured":"Friedman R.M.;Pacholec F.;Powell R.M.; &Lechner J.B. 1994.Blended Poly\/orthophosphate Inhibition of Heavy Metal Corrosion in Potable Water Delivery Systems Proc. AWWA 1994 Water Quality Technology Conference San Francisco."},{"key":"e_1_2_9_26_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF01783621"},{"key":"e_1_2_9_27_1","doi-asserted-by":"publisher","DOI":"10.2105\/AJPH.2015.303003"},{"key":"e_1_2_9_28_1","unstructured":"HDR Engineering 2009.An Analysis of the Correlation Between Lead Released From Galvanized Iron Piping and the Contents of Lead in Drinking Water. Summary report Bellevue Wash."},{"key":"e_1_2_9_29_1","doi-asserted-by":"publisher","DOI":"10.2166\/wh.2008.044"},{"key":"e_1_2_9_30_1","doi-asserted-by":"publisher","DOI":"10.1002\/j.1551-8833.2003.tb10343.x"},{"key":"e_1_2_9_31_1","doi-asserted-by":"publisher","DOI":"10.1002\/j.1551-8833.1991.tb07182.x"},{"key":"e_1_2_9_32_1","doi-asserted-by":"publisher","DOI":"10.1039\/b111379h"},{"key":"e_1_2_9_33_1","doi-asserted-by":"publisher","DOI":"10.1002\/j.1551-8833.2005.tb10847.x"},{"key":"e_1_2_9_34_1","doi-asserted-by":"publisher","DOI":"10.1289\/ehp.7688"},{"key":"e_1_2_9_35_1","unstructured":"Lechner J.B.&Ziemba L.M. 1989.Use of Blended Ortho\/Poly Phosphate in Corrosion Control.Proc. AWWA 1989 Annual Conference and Exposition Los Angeles."},{"key":"e_1_2_9_36_1","doi-asserted-by":"publisher","DOI":"10.1038\/jes.2012.129"},{"key":"e_1_2_9_37_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10653-012-9480-0"},{"key":"e_1_2_9_38_1","doi-asserted-by":"publisher","DOI":"10.1089\/ees.2014.0400"},{"key":"e_1_2_9_39_1","doi-asserted-by":"publisher","DOI":"10.1002\/j.1551-8833.2011.tb11437.x"},{"key":"e_1_2_9_40_1","unstructured":"McFadden M.;Reiber S.;Kwan P.; &Giani R. 2009.Investigation of Sorptive and Desorptive Processes Between Lead and Iron Corrosion Scales in Plumbing Materials.Proc. AWWA 2009 Water Quality Technology Conference Seattle."},{"key":"e_1_2_9_41_1","unstructured":"McFarren E.F.;Buelow R.W.;Thurnau R.C.;Gardels M.;Sorrell R.K.;Snyder P.; &Dressman R.C. 1977.Water Quality Deterioration in the Distribution System.AWWA 1997 Water Quality Technology Conference Kansas City Mo."},{"key":"e_1_2_9_42_1","doi-asserted-by":"publisher","DOI":"10.1002\/j.1551-8833.2002.tb09506.x"},{"key":"e_1_2_9_43_1","volume-title":"Munsell Soil Color Charts","year":"2000"},{"key":"e_1_2_9_44_1","unstructured":"Myers J.R. 1973.Corrosion of Galvanized Steel Potable\u2010Hot\u2010Water Pipes Hickam Air Force Base Hawaii.Australasian Corrosion Engineering May:29."},{"key":"e_1_2_9_45_1","doi-asserted-by":"publisher","DOI":"10.1289\/ehp.1409144"},{"key":"e_1_2_9_46_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtemb.2014.07.004"},{"key":"e_1_2_9_47_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.envint.2014.07.005"},{"key":"e_1_2_9_48_1","unstructured":"NTP (National Toxicology Program) 2012.National Toxicology Program Monograph on Health Effects of Low\u2010Level Lead. US Department of Health and Human Services National Toxicology Program Office of Health Assessment and Translation."},{"key":"e_1_2_9_49_1","doi-asserted-by":"publisher","DOI":"10.1021\/acs.est.6b04034"},{"key":"e_1_2_9_50_1","unstructured":"Rhoads G.C.;Brown M.J.;Cory\u2010Slechta D.A.;Dietrich K.N.;Gardner S.L.;Gottesfeld P.;Hansen K.;Kosnett M.;McCormick D.;McKee\u2010Huger E.;Parsons P.;Reyes B.;Sandel M.; &Williams D. 2012.Low Level Lead Exposure Harms Children: A Renewed Call for Primary Prevention Centers for Disease Control and Prevention www.cdc.gov\/nceh\/lead\/acclpp\/final_document_030712.pdf(accessed March 2017)."},{"key":"e_1_2_9_51_1","volume-title":"Contribution of Service Line and Plumbing Fixtures to Lead and Copper Rule Compliance Issues","author":"Sandvig A.","year":"2008"},{"key":"e_1_2_9_52_1","unstructured":"Schock M.R. 2004.Solubility Models and Their Limitations.AWWA 2004 Annual Conference and Exposition Orlando Fla."},{"key":"e_1_2_9_53_1","unstructured":"Schock M.R. 1985.Treatment or Water Quality Adjustment to Attain MCLs in Metallic Potable Water Plumbing Systems. EPA\/600\/9\u201085\/007 US Environmental Protection Agency Office of Drinking Water and Office of Research and Development Cincinnati."},{"key":"e_1_2_9_54_1","doi-asserted-by":"publisher","DOI":"10.5942\/jawwa.2014.106.0064"},{"key":"e_1_2_9_55_1","doi-asserted-by":"publisher","DOI":"10.1002\/j.1551-8833.2005.tb07521.x"},{"key":"e_1_2_9_56_1","unstructured":"Schock M.R.;Wagner I.; &Oliphant R. 1996(2nd ed.).The Corrosion and Solubility of Lead in Drinking Water. InInternal Corrosion of Water Distribution Systems.AWWA Research Foundation Denver & DVGW Forschungsstelle Karlsruhe Germany 131\u2013230."},{"issue":"6","key":"e_1_2_9_57_1","first-page":"491","article-title":"Scientific Basis for Control of Lead in Drinking Water by Water Treatment","volume":"35","author":"Sheiham I.","year":"1981","journal-title":"Journal of the Institute of Water Engineers and Scientists,"},{"key":"e_1_2_9_58_1","doi-asserted-by":"publisher","DOI":"10.2166\/aqua.2003.0042"},{"key":"e_1_2_9_59_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.watres.2011.10.006"},{"key":"e_1_2_9_60_1","doi-asserted-by":"publisher","DOI":"10.1080\/10643389.2011.556556"},{"key":"e_1_2_9_61_1","unstructured":"USEPA (US Environmental Protection Agency) 2016.Optimal Corrosion Control Treatment Evaluation Technical Recommendations for Primacy Agencies and Public Water Systems. EPA 816\u2010B\u201016\u2010003. USEPA Office of Water (4606M) Cincinnati."},{"key":"e_1_2_9_62_1","unstructured":"USEPA 1991.Final Regulatory Impact Analysis of National Primary Drinking Water Regulations for Lead and Copper. Prepared by Wade Miller Associates Inc. & Abt Associates Inc. EPA Contract 68\u2010C0\u20100069 Work Assignment No. 0\u20102. USEPA Washington."},{"issue":"3","key":"e_1_2_9_63_1","first-page":"258","article-title":"Comparison of Film Formation Using Phosphate Inhibitors in Systems With Comparable Water Qualities","volume":"111","author":"Vesecky S.M.","year":"1997","journal-title":"Journal of the New England Water Works Association,"}],"container-title":["Journal AWWA"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/awwa.onlinelibrary.wiley.com\/doi\/pdf\/10.5942\/jawwa.2017.109.0121","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,17]],"date-time":"2023-09-17T00:34:49Z","timestamp":1694910889000},"score":1,"resource":{"primary":{"URL":"https:\/\/awwa.onlinelibrary.wiley.com\/doi\/10.5942\/jawwa.2017.109.0121"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,11]]},"references-count":62,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2017,11]]}},"alternative-id":["10.5942\/jawwa.2017.109.0121"],"URL":"https:\/\/doi.org\/10.5942\/jawwa.2017.109.0121","archive":["Portico"],"relation":{},"ISSN":["0003-150X","1551-8833"],"issn-type":[{"value":"0003-150X","type":"print"},{"value":"1551-8833","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,11]]}}}