{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T20:01:32Z","timestamp":1760299292444},"reference-count":9,"publisher":"Georg Thieme Verlag KG","issue":"01","license":[{"start":{"date-parts":[[2022,4,20]],"date-time":"2022-04-20T00:00:00Z","timestamp":1650412800000},"content-version":"vor","delay-in-days":2301,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"},{"start":{"date-parts":[[2016,1,15]],"date-time":"2016-01-15T00:00:00Z","timestamp":1452816000000},"content-version":"tdm","delay-in-days":14,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["www.e-aps.org"],"crossmark-restriction":true},"short-container-title":["Arch Plast Surg"],"published-print":{"date-parts":[[2016,1]]},"abstract":"<jats:p>Titanium micro-mesh implants are widely used in orbital wall reconstructions because they have several advantageous characteristics. However, the rough and irregular marginal spurs of the cut edges of the titanium mesh sheet impede the efficacious and minimally traumatic insertion of the implant, because these spurs may catch or hook the orbital soft tissue, skin, or conjunctiva during the insertion procedure. In order to prevent this problem, we developed an easy method of inserting a titanium micro-mesh, in which it is wrapped with the aseptic transparent plastic film that is used to pack surgical instruments or is attached to one side of the inner suture package. Fifty-four patients underwent orbital wall reconstruction using a transconjunctival or transcutaneous approach. The wrapped implant was easily inserted without catching or injuring the orbital soft tissue, skin, or conjunctiva. In most cases, the implant was inserted in one attempt. Postoperative computed tomographic scans showed excellent placement of the titanium micro-mesh and adequate anatomic reconstruction of the orbital walls. This wrapping insertion method may be useful for making the insertion of titanium micro-mesh implants in the reconstruction of orbital wall fractures easier and less traumatic.<\/jats:p>","DOI":"10.5999\/aps.2016.43.1.84","type":"journal-article","created":{"date-parts":[[2016,2,2]],"date-time":"2016-02-02T09:11:01Z","timestamp":1454404261000},"page":"84-87","update-policy":"http:\/\/dx.doi.org\/10.5999\/crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["A Wrapping Method for Inserting Titanium Micro-Mesh Implants in the Reconstruction of Blowout Fractures"],"prefix":"10.1055","volume":"43","author":[{"given":"Tae Joon","family":"Choi","sequence":"additional","affiliation":[{"name":"Department of Plastic and Reconstructive Surgery, Kyung Hee University School of Medicine, Seoul, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jin Sik","family":"Burm","sequence":"additional","affiliation":[{"name":"Department of Plastic and Reconstructive Surgery, Kyung Hee University School of Medicine, Seoul, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Won Yong","family":"Yang","sequence":"additional","affiliation":[{"name":"Department of Plastic and Reconstructive Surgery, Kyung Hee University School of Medicine, Seoul, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sang Yoon","family":"Kang","sequence":"additional","affiliation":[{"name":"Department of Plastic and Reconstructive Surgery, Kyung Hee University School of Medicine, Seoul, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"194","published-online":{"date-parts":[[2022,4,20]]},"reference":[{"key":"ref1","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1016\/S0901-5027(05)80780-5","article-title":"Titanium mesh in orbital wall reconstruction","volume":"21","author":"AW Sugar","year":"1992","journal-title":"Int J Oral Maxillofac Surg"},{"key":"ref2","doi-asserted-by":"crossref","first-page":"555","DOI":"10.1097\/00001665-200111000-00010","article-title":"Various applications of titanium mesh screen implant to orbital wall fractures","volume":"12","author":"HS Park","year":"2001","journal-title":"J Craniofac Surg"},{"key":"ref3","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1054\/jcms.2001.0197","article-title":"Long-term results following reconstruction of craniofacial defects with titanium micro-mesh systems","volume":"29","author":"JJ Kuttenberger","year":"2001","journal-title":"J Craniomaxillofac Surg"},{"key":"ref4","first-page":"1022","article-title":"Incorporation of titanium mesh in orbital and midface reconstruction","volume":"110","author":"W Schubert","year":"2002","journal-title":"Plast Reconstr Surg"},{"key":"ref5","doi-asserted-by":"crossref","first-page":"1142","DOI":"10.1097\/SCS.0b013e3181e57241","article-title":"Orbital floor reconstruction","volume":"21","author":"R Tabrizi","year":"2010","journal-title":"J Craniofac Surg"},{"key":"ref6","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1055\/s-0031-1286120","article-title":"Orbital wall reconstruction with titanium mesh: retrospective study of 24 patients","volume":"4","author":"MF Gabrielli","year":"2011","journal-title":"Craniomaxillofac Trauma Reconstr"},{"key":"ref7","doi-asserted-by":"crossref","first-page":"362","DOI":"10.5999\/aps.2014.41.4.362","article-title":"Safety of silastic sheet for orbital wall reconstruction","volume":"41","author":"SJ Moon","year":"2014","journal-title":"Arch Plast Surg"},{"key":"ref8","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1016\/j.fjs.2014.02.002","article-title":"An innovative technique in orbital floor reconstruction avoiding complications: temporary use of the silicone guide","volume":"47","author":"TY Chang","year":"2014","journal-title":"Formosan J Surg"},{"key":"ref9","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1097\/00002341-199009000-00013","article-title":"Inferior rectus muscle entrapped by Teflon implant after orbital floor fracture repair","volume":"6","author":"JA Mauriello Jr","year":"1990","journal-title":"Ophthal Plast Reconstr Surg"}],"container-title":["Archives of Plastic Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.e-aps.org\/upload\/pdf\/aps-43-84.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/www.e-aps.org\/journal\/view.php?doi=10.5999\/aps.2016.43.1.84","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.5999\/aps.2016.43.1.84.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,4,20]],"date-time":"2022-04-20T23:31:59Z","timestamp":1650497519000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.5999\/aps.2016.43.1.84"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,1]]},"references-count":9,"journal-issue":{"issue":"01","published-online":{"date-parts":[[2022,4,20]]},"published-print":{"date-parts":[[2016,1]]}},"URL":"https:\/\/doi.org\/10.5999\/aps.2016.43.1.84","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["2234-6163","2234-6171"],"issn-type":[{"value":"2234-6163","type":"print"},{"value":"2234-6171","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,1]]},"assertion":[{"value":"2015-07-20","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2015-08-27","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2016-01-15","order":2,"name":"published","label":"Published online","group":{"name":"publication_history","label":"Publication History"}},{"value":"2016-01-15","order":3,"name":"published","label":"Print publication","group":{"name":"publication_history","label":"Publication History"}}]}}