{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T15:16:13Z","timestamp":1785597373774,"version":"3.56.0"},"reference-count":18,"publisher":"Japanese Society of Radiological Technology","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Nippon Hoshasen Gijutsu Gakkai Zasshi","Jpn. J. Radiol. Technol."],"published-print":{"date-parts":[[2020]]},"DOI":"10.6009\/jjrt.2020_jsrt_76.4.356","type":"journal-article","created":{"date-parts":[[2020,4,19]],"date-time":"2020-04-19T18:04:58Z","timestamp":1587319498000},"page":"356-365","source":"Crossref","is-referenced-by-count":6,"title":["Impact of Aperture Shape Controller on Volumetric Modulated Arc Therapy Treatment Planning for Nasopharyngeal Cancer","\u7167\u5c04\u91ce\u958b\u53e3\u5f62\u72b6\u30b3\u30f3\u30c8\u30ed\u30fc\u30e9\u304c\u4e0a\u54bd\u982d\u304c\u3093VMAT \u6cbb\u7642\u8a08\u753b\u306b\u4e0e\u3048\u308b\u5f71\u97ff\u306b\u3064\u3044\u3066"],"prefix":"10.6009","volume":"76","author":[{"given":"Tatsuya","family":"Kamima","sequence":"first","affiliation":[{"name":"Radiation Oncology Department, The Cancer Institute Hospital, Japanese Foundation for Cancer Research"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yu","family":"Murakami","sequence":"additional","affiliation":[{"name":"Radiation Oncology Department, The Cancer Institute Hospital, Japanese Foundation for Cancer Research"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masato","family":"Arima","sequence":"additional","affiliation":[{"name":"Radiation Oncology Department, The Cancer Institute Hospital, Japanese Foundation for Cancer Research"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yosuke","family":"Sato","sequence":"additional","affiliation":[{"name":"Radiation Oncology Department, The Cancer Institute Hospital, Japanese Foundation for Cancer Research"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Minoru","family":"Yoshioka","sequence":"additional","affiliation":[{"name":"Radiation Oncology Department, The Cancer Institute Hospital, Japanese Foundation for Cancer Research"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomoharu","family":"Sato","sequence":"additional","affiliation":[{"name":"Radiation Oncology Department, The Cancer Institute Hospital, Japanese Foundation for Cancer Research"},{"name":"Department of Radiology, Toyo Public Health College"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"4040","reference":[{"key":"1","unstructured":"1) \u65e5\u672c\u653e\u5c04\u7dda\u816b\u760d\u5b66\u4f1a\uff0eIV\uff0e\u4e0a\u54bd\u982d\u764c\uff0e\u653e\u5c04\u7dda\u6cbb\u7642\u8a08\u753b\u30ac\u30a4\u30c9\u30e9\u30a4\u30f32016 \u5e74\u7248\uff0e2016; 97\u2013104."},{"key":"2","doi-asserted-by":"crossref","unstructured":"2) Lee N, Harris J, Garden AS, et al. Intensity-modulated radiation therapy with or without chemotherapy for nasopharyngeal carcinoma: Radiation Therapy Oncology Group Phase II Trial 0225. J Clin Oncol 2009; 27(22): 3684\u20133690.","DOI":"10.1200\/JCO.2008.19.9109"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3) Agnew CE, Irvine DM, McGarry CK. Correlation of phantombased and log file patient-specific QA with complexity scores for VMAT. J Appl Clin Med Phys 2014; 15(6): 4994.","DOI":"10.1120\/jacmp.v15i6.4994"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4) Ling CC, Zhang P, Archambault Y, et al. Commissioning and quality assurance of RapidArc radiotherapy delivery system. Int J Radiat Oncol Biol Phys 2008; 72(2): 575\u2013581.","DOI":"10.1016\/j.ijrobp.2008.05.060"},{"key":"5","doi-asserted-by":"crossref","unstructured":"5) Tatsumi D, Hosono MN, Nakada R, et al. Direct impact analysis of multi-leaf collimator leaf position errors on dose distributions in volumetric modulated arc therapy: a pass rate calculation between measured planar doses with and without the position errors. Phys Med Biol 2011; 56(20): N237\u2013246.","DOI":"10.1088\/0031-9155\/56\/20\/N03"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6) Peng J, Zhang Z, Zhou L, et al. A study on investigating the delivery parameter error effect on the variation of patient quality assurance during RapidArc treatment. Med Phys 2013; 40(3): 031703.","DOI":"10.1118\/1.4789631"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7) Xu Z, Wang IZ, Kumaraswamy LK, et al. Evaluation of dosimetric effect caused by slowing with multi-leaf collimator (MLC) leaves for volumetric modulated arc therapy (VMAT). Radiol Oncol 2016; 50(1): 121\u2013128.","DOI":"10.1515\/raon-2016-0008"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8) Wijesooriya K, Aliotta E, Benedict S, et al. RapidArc patient specific mechanical delivery accuracy under extreme mechanical limits using linac log files. Med Phys 2012; 39(4): 1846\u20131853.","DOI":"10.1118\/1.3690464"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9) Park JM, Park SY, Kim H. Modulation index for VMAT considering both mechanical and dose calculation uncertainties. Phys Med Biol 2015; 60(18): 7101\u20137125.","DOI":"10.1088\/0031-9155\/60\/18\/7101"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10) Ezzell GA, Burmeister JW, Dogan N, et al. IMRT commissioning: multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119. Med Phys 2009; 36(11): 5359\u20135373.","DOI":"10.1118\/1.3238104"},{"key":"11","doi-asserted-by":"crossref","unstructured":"11) McNiven AL, Sharpe MB, Purdie TG. A new metric for assessing IMRT modulation complexity and plan deliverability. Med Phys 2010; 37(2): 505\u2013515.","DOI":"10.1118\/1.3276775"},{"key":"12","doi-asserted-by":"crossref","unstructured":"12) Masi L, Doro R, Favuzza V, et al. Impact of plan parameters on the dosimetric accuracy of volumetric modulated arc therapy. Med Phys 2013; 40(7): 071718.","DOI":"10.1118\/1.4810969"},{"key":"13","doi-asserted-by":"crossref","unstructured":"13) \u4eca\u6c5f\u7984\u4e00\uff0c\u65e9\u4e59\u5973\u76f4\u4e5f\uff0c\u7af9\u4e2d\u91cd\u6cbb\uff0c\u4ed6\uff0e\u80ba\u5b9a\u4f4d\u653e\u5c04\u7dda\u6cbb\u7642\u306b\u304a\u3051\u308b\u7a4d\u7b97\u7dda\u91cf\u5206\u5e03\u306e\u4e8b\u5f8c\u8a55\u4fa1\u6cd5\u306e\u691c\u8a0e\uff0e\u65e5\u653e\u6280\u5b66\u8a8c 2016; 72(3): 251\u2013260.","DOI":"10.6009\/jjrt.2016_JSRT_72.3.251"},{"key":"14","unstructured":"14) \u65e5\u672c\u653e\u5c04\u7dda\u816b\u760d\u5b66\u4f1aQA \u59d4\u54e1\u4f1a\uff0e\u7dda\u91cf\u5206\u5e03\u306e\u8a55\u4fa1\u6307\u6a19 (D95, V20, HI, CI)\uff0e\u4f53\u5e79\u90e8\u5b9a\u4f4d\u653e\u5c04\u7dda\u6cbb\u7642\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\uff0e\u65e5\u653e\u7dda\u816b\u760d\u4f1a\u8a8c2006; 18(1): 1\u201317."},{"key":"15","doi-asserted-by":"crossref","unstructured":"15) Rajasekaran D, Jeevanandam P, Sukumar P, et al. A study on the correlation between plan complexity and gamma index analysis in patient specific quality assurance of volumetric modulated arc therapy. Rep Pract Oncol Radiother 2015; 20(1): 57\u201365.","DOI":"10.1016\/j.rpor.2014.08.006"},{"key":"16","doi-asserted-by":"crossref","unstructured":"16) Ohira S, Ueda Y, Isono M, et al. Can clinically relevant dose errors in patient anatomy be detected by gamma passing rate or modulation complexity score in volumetric-modulated arc therapy for intracranial tumors? J Radiat Res 2017; 58(5): 685\u2013692.","DOI":"10.1093\/jrr\/rrx006"},{"key":"17","doi-asserted-by":"crossref","unstructured":"17) Murakami Y, Magome T, Matsubayashi F, et al. Evaluation of organ-at-risk dose reduction with jaw tracking technique in flattening filter-free beams in lung stereotactic body radiation therapy. Phys Med 2019; 61: 70\u201376.","DOI":"10.1016\/j.ejmp.2019.04.018"},{"key":"18","doi-asserted-by":"crossref","unstructured":"18) McGarry CK, Agnew CE, Hussein M, et al. The role of complexity metrics in a multi-institutional dosimetry audit of VMAT. Br J Radiol 2016; 891057: 20150445.","DOI":"10.1259\/bjr.20150445"}],"container-title":["Japanese Journal of Radiological Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jjrt\/76\/4\/76_2020_JSRT_76.4.356\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T03:46:55Z","timestamp":1785556015000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jjrt\/76\/4\/76_2020_JSRT_76.4.356\/_article\/-char\/ja\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020]]},"references-count":18,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.6009\/jjrt.2020_jsrt_76.4.356","relation":{},"ISSN":["0369-4305","1881-4883"],"issn-type":[{"value":"0369-4305","type":"print"},{"value":"1881-4883","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020]]},"article-number":"2020_JSRT_76.4.356"}}