{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T16:41:29Z","timestamp":1790613689823,"version":"4.1.0"},"reference-count":14,"publisher":"Japanese Society of Radiological Technology","issue":"12","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Nippon Hoshasen Gijutsu Gakkai Zasshi","Jpn. J. Radiol. Technol."],"published-print":{"date-parts":[[2022]]},"DOI":"10.6009\/jjrt.2022-1316","type":"journal-article","created":{"date-parts":[[2022,10,5]],"date-time":"2022-10-05T22:21:20Z","timestamp":1665008480000},"page":"1406-1414","source":"Crossref","is-referenced-by-count":2,"title":["Usefulness of an Ultrasound System with Automatic Bladder Urine Volume Measurement Using Artificial Intelligence Technology in Radiotherapy","Artificial intelligence\u6280\u8853\u3092\u6d3b\u7528\u3057\u305f\u8180\u80f1\u5bb9\u91cf\u81ea\u52d5\u8a08\u6e2c\u6a5f\u80fd\u642d\u8f09\u8d85\u97f3\u6ce2\u88c5\u7f6e\u306e\u653e\u5c04\u7dda\u6cbb\u7642\u306b\u304a\u3051\u308b\u6709\u7528\u6027"],"prefix":"10.6009","volume":"78","author":[{"given":"Mayuri","family":"Shibata","sequence":"first","affiliation":[{"name":"Division of Radiotherapy, Department of Medical Technology, Takarazuka City Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wataru","family":"Okada","sequence":"additional","affiliation":[{"name":"Division of Radiotherapy, Department of Medical Technology, Takarazuka City Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Keisuke","family":"Sano","sequence":"additional","affiliation":[{"name":"Division of Radiotherapy, Department of Medical Technology, Takarazuka City Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenji","family":"Nakamura","sequence":"additional","affiliation":[{"name":"Division of Radiotherapy, Department of Medical Technology, Takarazuka City Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yusuke","family":"Sakai","sequence":"additional","affiliation":[{"name":"Division of Radiotherapy, Department of Medical Technology, Takarazuka City Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshihiro","family":"Ueda","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Osaka International Cancer Institute"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenji","family":"Uemoto","sequence":"additional","affiliation":[{"name":"Miyakojima iGRT Clinic"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshiki","family":"Takei","sequence":"additional","affiliation":[{"name":"Department of Radiology, Kindai University Nara Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masao","family":"Tanooka","sequence":"additional","affiliation":[{"name":"Division of Radiotherapy, Department of Medical Technology, Takarazuka City Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"4040","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1\uff09\u2003Katanoda K, Hori M, Saito E, et al. Updated trends in cancer in Japan: incidence in 1985\u20132015 and mortality in 1958\u20132018: a sign of decrease in cancer incidence. J Epidemiol 2021; 31(7): 426\u2013450.","DOI":"10.2188\/jea.JE20200416"},{"key":"2","unstructured":"2\uff09\u2003\u65e5\u672c\u653e\u5c04\u7dda\u816b\u760d\u5b66\u4f1a\uff0e\u653e\u5c04\u7dda\u6cbb\u7642\u30ac\u30a4\u30c9\u30e9\u30a4\u30f32020\u5e74\u7248\uff0e\u91d1\u539f\u51fa\u7248\uff0c\u6771\u4eac\uff0c2012\uff0c248\u2013267."},{"key":"3","unstructured":"3\uff09\u2003\u5927\u897f\u6d0b\uff0c\u5510\u6fa4\u4e45\u7f8e\u5b50\uff0c\u5510\u6fa4\u514b\u4e4b\uff0e\u304c\u3093\u30fb\u653e\u5c04\u7dda\u7642\u6cd52017\u2002\u6539\u8a02\u7b2c7\u7248\uff0e\u79c0\u6f64\u793e\uff0c2017\uff0c971\u2013976."},{"key":"4","doi-asserted-by":"crossref","unstructured":"4\uff09\u2003Chen HH, Lin PT, Kuo LT, et al. Bladder volume reproducibility after water consumption in patients with prostate cancer undergoing radiotherapy: a systematic review and meta-analysis. Biomed J 2021; 44(6) (Suppl 2): S226\u2013S234.","DOI":"10.1016\/j.bj.2020.11.004"},{"key":"5","doi-asserted-by":"crossref","unstructured":"5\uff09\u2003Melian E, Mageras GS, Fuks Z, et al. Variation in prostate position quantitation and implications for three- dimensional conformal treatment planning. Int J Radiat Oncol Biol Phys 1997; 38(1): 73\u201381.","DOI":"10.1016\/S0360-3016(97)00221-6"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6\uff09\u2003Zelefsky MJ, Crean D, Mageras GS, et al. Quantification and predictors of prostate position variability in 50 patients evaluated with multiple CT scans during conformal radiotherapy. Radiother Oncol 1999; 50(2): 225\u2013234.","DOI":"10.1016\/S0167-8140(99)00011-0"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7\uff09\u2003Frank SJ, Dong L, Kudchadker RJ, et al. Quantification of prostate and seminal vesicle interfraction variation during IMRT. Int J Radiat Oncol Biol Phys 2008; 71(3): 813\u2013820.","DOI":"10.1016\/j.ijrobp.2007.10.028"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8\uff09\u2003Ung KA, White R, Mathlum M, et al. Comparison study of portable bladder scanner versus cone-beam CT scan for measuring bladder volumes in post-prostatectomy patients undergoing radiotherapy. J Med Imaging Radiat Oncol 2014; 58(3): 377\u2013383.","DOI":"10.1111\/1754-9485.12171"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9\uff09\u2003Stam MR, van Lin ENJT, van der Vight LP, et al. Bladder filling variation during radiation treatment of prostate cancer: can the use of a bladder ultrasound scanner and biofeedback optimize bladder filling? Int J Radiat Oncol Biol Phys 2006; 65(2): 371\u2013377.","DOI":"10.1016\/j.ijrobp.2005.12.039"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10\uff09\u2003Ohira S, Komiyama R, Kanayama N, et al. Improvement in bladder volume reproducibility using A-mode portable ultrasound bladder scanner in moderate-hypofractionated volumetric modulated arc therapy for prostate cancer patients. J Appl Clin Med Phys 2022; 23(4): e13546.","DOI":"10.1002\/acm2.13546"},{"key":"11","doi-asserted-by":"crossref","unstructured":"11\uff09\u2003Oh-Oka H, Nose R. Efficacy and problems of bladder volume measurement using portable three dimensional ultrasound scanning device: in particular, on measuring bladder volume lower than 100\u2009ml. Nippon Hinyokika Gakkai Zasshi 2005; 96(6): 601\u2013609.","DOI":"10.5980\/jpnjurol1989.96.601"},{"key":"12","unstructured":"12\uff09\u2003\u85ea\u4e2d\u5e78\u4e00\uff0c\u56db\u8c37\u6df3\u5b50\uff0c\u4ef2\u4e0a\u8c6a\u4e8c\u6717\uff0c\u4ed6\uff0e4\u7a2e\u985e\u306e\u8d85\u97f3\u6ce2\u691c\u67fb\u88c5\u7f6e\u306b\u3088\u308b\u8180\u80f1\u5185\u5bb9\u91cf\u6e2c\u5b9a\u306e\u59a5\u5f53\u6027\u306e\u6bd4\u8f03\uff0eJ Jpn WOCM\u20022016; 20(4): 420\u2013425."},{"key":"13","doi-asserted-by":"crossref","unstructured":"13\uff09\u2003Mullaney L, O\u2019Shea E, Dunne MT, et al. A comparison of bladder volumes based on treatment planning CT and BladderScan<sup>\u00ae<\/sup> BVi 6100 ultrasound device in a prostate radiation therapy population. Br J Radiol 2018; 91(1091): 20180160.","DOI":"10.1259\/bjr.20180160"},{"key":"14","doi-asserted-by":"crossref","unstructured":"14\uff09\u2003Fujioka C, Ishii K, Yamanaga T, et al. Optimal bladder volume at treatment planning for prostate cancer patients receiving volumetric modulated arc therapy. Pract Radiat Oncol 2016; 6(6): 395\u2013401.","DOI":"10.1016\/j.prro.2016.05.007"}],"container-title":["Japanese Journal of Radiological Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jjrt\/78\/12\/78_2022-1316\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,24]],"date-time":"2022-12-24T03:29:12Z","timestamp":1671852552000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jjrt\/78\/12\/78_2022-1316\/_article\/-char\/ja\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022]]},"references-count":14,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.6009\/jjrt.2022-1316","relation":{},"ISSN":["0369-4305","1881-4883"],"issn-type":[{"value":"0369-4305","type":"print"},{"value":"1881-4883","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022]]},"article-number":"2022-1316"}}