{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,6,25]],"date-time":"2023-06-25T04:23:50Z","timestamp":1687667030285},"reference-count":21,"publisher":"Japanese Society of Radiological Technology","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Nippon Hoshasen Gijutsu Gakkai Zasshi","Jpn. J. Radiol. Technol."],"published-print":{"date-parts":[[2023]]},"DOI":"10.6009\/jjrt.2023-1349","type":"journal-article","created":{"date-parts":[[2023,4,13]],"date-time":"2023-04-13T22:13:32Z","timestamp":1681424012000},"page":"544-554","source":"Crossref","is-referenced-by-count":0,"title":["Study of Phantom Length Correction for kV-Cone Beam CT Dose Evaluation Method Using Farmer-type Ionization Chamber and Cylindrical Phantom","\u30d5\u30a1\u30fc\u30de\u5f62\u96fb\u96e2\u7bb1\u7dda\u91cf\u8a08\u3068\u5186\u67f1\u5f62\u30d5\u30a1\u30f3\u30c8\u30e0\u3092\u7528\u3044\u305fkV-cone beam CT\u7dda\u91cf\u8a55\u4fa1\u6cd5\u306b\u304a\u3051\u308b\u30d5\u30a1\u30f3\u30c8\u30e0\u9577\u88dc\u6b63\u65b9\u6cd5\u306e\u691c\u8a0e"],"prefix":"10.6009","volume":"79","author":[{"given":"Masataka","family":"Sakamoto","sequence":"first","affiliation":[{"name":"Department of Radiology, Hamamatsu University Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Koji","family":"Sasaki","sequence":"additional","affiliation":[{"name":"Graduate School of Radiological Technology, Gunma Prefectural College of Health Sciences"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hayato","family":"Tsuno","sequence":"additional","affiliation":[{"name":"Graduate School of Radiological Technology, Gunma Prefectural College of Health Sciences"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"4040","reference":[{"key":"1","unstructured":"1\uff09\u2003\u897f\u5c3e\u798e\u6cbb\uff0e\u65e5\u672c\u533b\u5b66\u7269\u7406\u5b66\u4f1a\u2002QA\/QC\u59d4\u54e1\u4f1a\u5831\u544a\u2002\u753b\u50cf\u8a98\u5c0e\u653e\u5c04\u7dda\u6cbb\u7642\u81e8\u5e8a\u5c0e\u5165\u306e\u305f\u3081\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\uff08\u7565\u79f0\uff1aIGRT\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\uff09\uff0e\u533b\u7269\u7406\u20022010; 30(2): 49\u201353."},{"key":"2","doi-asserted-by":"crossref","unstructured":"2\uff09\u2003Klein EE, Hanley J, Bayouth J, et al. Task Group 142 report: Quality assurance of medical accelerators. Med Phys 2009; 36(9): 4197\u20134212.","DOI":"10.1118\/1.3190392"},{"key":"3","unstructured":"3\uff09\u2003\u65e5\u672c\u653e\u5c04\u7dda\u6280\u8853\u5b66\u4f1a\u653e\u5c04\u7dda\u6cbb\u7642\u5206\u79d1\u4f1a\u2002\u7de8\uff0e\u653e\u5c04\u7dda\u533b\u7642\u6280\u8853\u5b66\u53e2\u66f8\uff0833\uff09\u2002\u653e\u5c04\u7dda\u6cbb\u7642\u306b\u304a\u3051\u308b\u4f4d\u7f6e\u7167\u5408\u3068\u30bb\u30c3\u30c8\u30a2\u30c3\u30d7\u306e\u5b9f\u969b\uff0e\u65e5\u672c\u653e\u5c04\u7dda\u6280\u8853\u5b66\u4f1a\u51fa\u7248\u59d4\u54e1\u4f1a\uff0c\u4eac\u90fd\uff0c2015."},{"key":"4","doi-asserted-by":"crossref","unstructured":"4\uff09\u2003Murphy MJ, Balter J, Balter S, et al. The management of imaging dose during image-guided radiotherapy: Report of AAPM Task Group 75. Med Phys 2007; 34(10): 4041\u20134063.","DOI":"10.1118\/1.2775667"},{"key":"5","doi-asserted-by":"crossref","unstructured":"5\uff09\u2003Bissonnette J-P, Balter PA, Dong L, et al. Quality assurance for image-guided radiation therapy utilizing CT-based technologies: A report of AAPM TG-179. Med Phys 2012; 39(4): 1946\u20131963.","DOI":"10.1118\/1.3690466"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6\uff09\u2003International Commission on Radiological Protection. Managing patient dose in computed tomography. Ann ICRP 2000; 30(4): 7\u201345.","DOI":"10.1016\/S0146-6453(01)00049-5"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7\uff09\u2003Rehani MM, Gupta R, Bartling S, et al. Radiological Protection in Cone Beam Computed Tomography (CBCT). ICRP Publication 129. Ann ICRP 2015; 44(1): 9\u2013127.","DOI":"10.1177\/0146645315575485"},{"key":"8","unstructured":"8\uff09\u2003\u65e5\u672c\u533b\u5b66\u7269\u7406\u5b66\u4f1a\u2002\u7de8\uff0e\u5916\u90e8\u653e\u5c04\u7dda\u6cbb\u7642\u306b\u304a\u3051\u308b\u6c34\u5438\u53ce\u7dda\u91cf\u306e\u6a19\u6e96\u8a08\u6e2c\u6cd5\uff08\u6a19\u6e96\u8a08\u6e2c\u6cd512\uff09\uff0e\u901a\u5546\u7523\u696d\u7814\u7a76\u6240\uff0c\u6771\u4eac\uff0c2012."},{"key":"9","doi-asserted-by":"crossref","unstructured":"9\uff09\u2003Ma C-M, Coffey CW, DeWerd LA, et al. AAPM protocol for 40\u2013300\u2009kV x-ray beam dosimetry in radiotherapy and radiobiology. Med Phys 2001; 28(6): 868\u2013893.","DOI":"10.1118\/1.1374247"},{"key":"10","unstructured":"10\uff09\u2003International Atomic Energy Agency. Status of Computed Tomography Dosimetry for Wide Cone Beam Scanners. IAEA Human Health Reports No. 5. IAEA, 2011."},{"key":"11","unstructured":"11\uff09\u2003American Association of Physicists in Medicine. Comprehensive Methodology for the Evaluation of Radiation Dose in X-Ray Computed Tomography. AAPM Task Group 111. AAPM, 2010."},{"key":"12","doi-asserted-by":"crossref","unstructured":"12\uff09\u2003\u6cb3\u91ce\u53cb\u5b8f\uff0c\u8352\u6728\u4e0d\u6b21\u7537\uff0c\u4e2d\u53e3\u88d5\u4e8c\uff0c\u4ed6\uff0e\u753b\u50cf\u8a98\u5c0e\u653e\u5c04\u7dda\u6cbb\u7642\u306b\u304a\u3051\u308bkV-cone beam CT\u306e\u88ab\u3070\u304f\u7dda\u91cf\u306e\u8a55\u4fa1\uff0e\u65e5\u653e\u6280\u5b66\u8a8c\u20022013; 69(7): 753\u2013760.","DOI":"10.6009\/jjrt.2013_JSRT_69.7.753"},{"key":"13","doi-asserted-by":"crossref","unstructured":"13\uff09\u2003Hioki K, Araki F, Ohno T, et al. Absorbed dose measurements for kV-cone beam computed tomography in image-guided radiation therapy. Phys Med Biol 2014; 59(23): 7297\u20137313.","DOI":"10.1088\/0031-9155\/59\/23\/7297"},{"key":"14","unstructured":"14\uff09\u2003Seltzer SM\uff0cHubbell JH\uff0e\u524d\u8d8a\u4e45\u2002\u76e3\u4fee\uff0e\u653e\u5c04\u7dda\u533b\u7642\u6280\u8853\u5b66\u53e2\u66f8\uff0811\uff09\u5149\u5b50\u6e1b\u5f31\u4fc2\u6570\u30c7\u30fc\u30bf\u30d6\u30c3\u30af\uff0e\u65e5\u672c\u653e\u5c04\u7dda\u6280\u8853\u5b66\u4f1a\u51fa\u7248\u59d4\u54e1\u4f1a\uff0c\u4eac\u90fd\uff0c1995."},{"key":"15","unstructured":"15\uff09\u2003\u65e5\u672c\u533b\u5b66\u7269\u7406\u5b66\u4f1a\u8a08\u6e2c\u59d4\u54e1\u4f1a\u96fb\u4f4d\u8a08\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u30ef\u30fc\u30ad\u30f3\u30b0\u30b0\u30eb\u30fc\u30d7\uff0e\u96fb\u8377\u6e2c\u5b9a\u306e\u4e0d\u78ba\u304b\u3055\uff0e\u653e\u5c04\u7dda\u6cbb\u7642\u7528\u7dda\u91cf\u8a08\u306b\u7528\u3044\u3089\u308c\u308b\u96fb\u4f4d\u8a08\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\uff0e\u65e5\u672c\u533b\u5b66\u7269\u7406\u5b66\u4f1a\uff0c2017\uff0c72."},{"key":"16","unstructured":"16\uff09\u2003International Atomic Energy Agency. Absorbed Dose Determination in External Beam Radiotherapy. IAEA Technical Reports Series No. 398. IAEA, 2000."},{"key":"17","doi-asserted-by":"crossref","unstructured":"17\uff09\u2003Yoo S, Grimm D, Zhu R, et al. Clinical implementation of AAPM TG61 protocol for kilo-voltage X-ray beam dosimetry. Med Phys 2002; 29(10): 2269\u20132273.","DOI":"10.1118\/1.1508376"},{"key":"18","unstructured":"18\uff09\u2003\u65e5\u672c\u653e\u5c04\u7dda\u6280\u8853\u5b66\u4f1a\u8a08\u6e2c\u5206\u79d1\u4f1a\uff0e\u653e\u5c04\u7dda\u6280\u8853\u5b66\u4f1a\u53e2\u66f8\uff0825\uff09\u533b\u7642\u88ab\u3070\u304f\u6e2c\u5b9a\u30c6\u30ad\u30b9\u30c8\uff08\u6539\u8a022\u7248\uff09\uff0e\u65e5\u672c\u653e\u5c04\u7dda\u6280\u8853\u5b66\u4f1a\u51fa\u7248\u59d4\u54e1\u4f1a\uff0c\u4eac\u90fd\uff0c2012."},{"key":"19","doi-asserted-by":"crossref","unstructured":"19\uff09\u2003Mori S, Endo M, Nishizawa K, et al. Enlarged longitudinal dose profiles in cone-beam CT and the need for modified dosimetry. Med Phys 2005; 32(4): 1061\u20131069.","DOI":"10.1118\/1.1877852"},{"key":"20","doi-asserted-by":"crossref","unstructured":"20\uff09\u2003Lin PP-J, Herrnsdorf L. Pseud helical scan for the dose profile measurements of 160-mm-wide cone-beam MDCT. AJR 2010; 194(4): 897\u2013902.","DOI":"10.2214\/AJR.09.3048"},{"key":"21","doi-asserted-by":"crossref","unstructured":"21\uff09\u2003Descamps C, Gonzalez M, Garrigo E, et al. Measurements of the dose delivered during CT exams using AAPM Task Group Report No.111. J Appl Clin Med Phys 2012; 13(6): 293\u2013302.","DOI":"10.1120\/jacmp.v13i6.3934"}],"container-title":["Japanese Journal of Radiological Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jjrt\/79\/6\/79_2023-1349\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,6,24]],"date-time":"2023-06-24T03:49:14Z","timestamp":1687578554000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jjrt\/79\/6\/79_2023-1349\/_article\/-char\/ja\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023]]},"references-count":21,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.6009\/jjrt.2023-1349","relation":{},"ISSN":["0369-4305","1881-4883"],"issn-type":[{"value":"0369-4305","type":"print"},{"value":"1881-4883","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023]]},"article-number":"2023-1349"}}