{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,5,14]],"date-time":"2024-05-14T00:24:44Z","timestamp":1715646284874},"reference-count":23,"publisher":"Japanese Society of Radiological Technology","issue":"7","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Nippon Hoshasen Gijutsu Gakkai Zasshi","Jpn. J. Radiol. Technol."],"published-print":{"date-parts":[[2023]]},"DOI":"10.6009\/jjrt.2023-1375","type":"journal-article","created":{"date-parts":[[2023,6,13]],"date-time":"2023-06-13T22:11:57Z","timestamp":1686694317000},"page":"682-692","source":"Crossref","is-referenced-by-count":0,"title":["Verification of Dose Distribution in Cervical Cancer Brachytherapy Using Metal and Plastic Applicators","\u91d1\u5c5e\u304a\u3088\u3073\u6a39\u8102\u88fd\u30a2\u30d7\u30ea\u30b1\u30fc\u30bf\u3092\u7528\u3044\u305f\u5b50\u5bae\u9838\u304c\u3093\u8154\u5185\u7167\u5c04\u306b\u304a\u3051\u308b\u7dda\u91cf\u5206\u5e03\u306e\u691c\u8a3c"],"prefix":"10.6009","volume":"79","author":[{"given":"Fumihiro","family":"Tomita","sequence":"first","affiliation":[{"name":"Graduate School of Health Sciences, Department of Radiological Sciences, Ibaraki Prefectural University of Health Sciences"},{"name":"Department of Radiological Sciences, Ibaraki Prefectural University of Health Sciences"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiraku","family":"Fuse","sequence":"additional","affiliation":[{"name":"Department of Radiological Sciences, Ibaraki Prefectural University of Health Sciences"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tatsuya","family":"Fujisaki","sequence":"additional","affiliation":[{"name":"Department of Radiological Sciences, Ibaraki Prefectural University of Health Sciences"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kenji","family":"Yasue","sequence":"additional","affiliation":[{"name":"Department of Radiological Sciences, Ibaraki Prefectural University of Health Sciences"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sin","family":"Miyakawa","sequence":"additional","affiliation":[{"name":"Department of Radiological Sciences, Ibaraki Prefectural University of Health Sciences"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hideaki","family":"Ikoma","sequence":"additional","affiliation":[{"name":"Department of Radiation Technology, Ibaraki Prefectural Central Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomoyuki","family":"Yoshizawa","sequence":"additional","affiliation":[{"name":"Department of Radiology, Tsuchiura Kyodo General Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Katsuhiko","family":"Oyama","sequence":"additional","affiliation":[{"name":"Department of Radiology, Tsuchiura Kyodo General Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Satoshi","family":"Oyama","sequence":"additional","affiliation":[{"name":"Department of Radiology, Tsuchiura Kyodo General Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toshiyuki","family":"Okumura","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Ibaraki Prefectural Central Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshio","family":"Tamaki","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Fukushima Rosai Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"4040","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1\uff09\u2003Nakano T, Kato S, Ohno T, et al. Long-term results of high-dose rate intracavitary brachytherapy for squamous cell carcinoma of the uterine cervix. Cancer 2005; 103(1): 92\u2013101.","DOI":"10.1002\/cncr.20734"},{"key":"2","doi-asserted-by":"crossref","unstructured":"2\uff09\u2003Sturdza A, P\u00f6tter R, Fokdal LU, et al. Image guided brachytherapy in locally advanced cervical cancer: improved pelvic control and survival in RetroEMBRACE, a multicenter cohort study. Radiother Oncol 2016; 120(3): 428\u2013433.","DOI":"10.1016\/j.radonc.2016.03.011"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3\uff09\u2003Ohno T, Noda SE, Okonogi N, et al. In-room computed tomography-based brachytherapy for uterine cervical cancer: results of a 5-year retrospective study. J Radiat Res 2017; 58(4): 543\u2013551.","DOI":"10.1093\/jrr\/rrw121"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4\uff09\u2003Ohno T, Toita T, Tsujino K, et al. A questionnaire-based survey on 3D image-guided brachytherapy for cervical cancer in Japan: advances and obstacles. J Radiat Res 2015; 56(6): 897\u2013903.","DOI":"10.1093\/jrr\/rrv047"},{"key":"5","doi-asserted-by":"crossref","unstructured":"5\uff09\u2003Nath R, Anderson LL, Luxton G, et al. Dosimetry of interstitial brachytherapy sources: recommendations of the AAPM Radiation Therapy Committee Task Group No. 43. American Association of Physicists in Medicine. Med Phys 1995; 22(2): 209\u2013234.","DOI":"10.1118\/1.597458"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6\uff09\u2003Rivard MJ, Coursey BM, DeWerd LA, et al. Update of AAPM Task Group No. 43 Report: a revised AAPM protocol for brachytherapy dose calculations. Med Phys 2004; 31(3): 633\u2013674.","DOI":"10.1118\/1.1646040"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7\uff09\u2003Morcos M, Viswanathan AN, Enger SA. On the impact of absorbed dose specification, tissue heterogeneities, and applicator heterogeneities on Monte Carlo-based dosimetry of Ir-192, Se-75, and Yb-169 in conventional and intensity-modulated brachytherapy for the treatment of cervical cancer. Med Phys 2021; 48(5): 2604\u20132613.","DOI":"10.1002\/mp.14802"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8\uff09\u2003Sadeghi MH, Sina S, Mehdizadeh A, et al. The effect of tandem-ovoid titanium applicator on points A, B, bladder, and rectum doses in gynecological brachytherapy using <sup>192<\/sup>Ir. J Contemp Brachytherapy 2018; 10(1): 91\u201395.","DOI":"10.5114\/jcb.2018.74314"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9\uff09\u2003Fuse H, Hanada K, Fujisaki T, et al. Determination of scaling factors for a new plastic phantom at 6\u201315\u2009MeV electron beams. Radiat Phys Chem 2022; 193: 109994.","DOI":"10.1016\/j.radphyschem.2022.109994"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10\uff09\u2003Fuse H, Oyama S, Fujisaki T, et al. Mouthpiece polymer-gel dosimeter for in vivo oral dosimetry during head and neck radiotherapy. Appl Radiat Isot 2022; 186: 110301.","DOI":"10.1016\/j.apradiso.2022.110301"},{"key":"11","unstructured":"11\uff09\u2003Kawrakow I, Mainegra-Hing E, Rogers DWO, et al. The EGSnrc Code System: Monte Carlo Simulation of Electron and Photon Transport, NRCC Report PIRS-701. National Research Council Canada, 2020."},{"key":"12","doi-asserted-by":"crossref","unstructured":"12\uff09\u2003Chamberland MJ, Taylor RE, Rogers DW, et al. egs_brachy: a versatile and fast Monte Carlo code for brachytherapy. Phys Med Biol 2016; 61(23): 8214\u20138231.","DOI":"10.1088\/0031-9155\/61\/23\/8214"},{"key":"13","doi-asserted-by":"crossref","unstructured":"13\uff09\u2003Granero D, Vijande J, Ballester F, et al. Dosimetry revisited for the HDR <sup>192<\/sup>Ir brachytherapy source model mHDR-v2. Med Phys 2011; 38(1): 487\u2013494.","DOI":"10.1118\/1.3531973"},{"key":"14","doi-asserted-by":"crossref","unstructured":"14\uff09\u2003Taylor REP, Rogers DWO. EGSnrc Monte Carlo calculated dosimetry parameters for <sup>192<\/sup>Ir and <sup>169<\/sup>Yb brachytherapy sources. Med Phys 2008; 35(11): 4933\u20134944.","DOI":"10.1118\/1.2987676"},{"key":"15","unstructured":"15\uff09\u2003NuDat 3.0. Brookhaven National Laboratory. Decay data retrieval code. http:\/\/www.nndc.bnl.gov\/nudat3\/"},{"key":"16","doi-asserted-by":"crossref","unstructured":"16\uff09\u2003P\u00e9rez-Calatayud J, Granero D, Ballester F. Phantom size in brachytherapy source dosimetric studies. Med Phys 2004; 31(7): 2075\u20132081.","DOI":"10.1118\/1.1759826"},{"key":"17","doi-asserted-by":"crossref","unstructured":"17\uff09\u2003Low DA, Harms WB, Mutic S, et al. A technique for the quantitative evaluation of dose distributions. Med Phys 1998; 25(5): 656\u2013661.","DOI":"10.1118\/1.598248"},{"key":"18","doi-asserted-by":"crossref","unstructured":"18\uff09\u2003Okonogi N, Wakatsuki M, Mizuno H, et al. Preliminary survey of 3D image-guided brachytherapy for cervical cancer at representative hospitals in Asian countries. J Radiat Res 2020; 61(4): 608\u2013615.","DOI":"10.1093\/jrr\/rraa025"},{"key":"19","doi-asserted-by":"crossref","unstructured":"19\uff09\u2003Rossi G, Gainey M, Kollefrath M, et al. Suitability of the microDiamond detector for experimental determination of the anisotropy function of High Dose Rate <sup>192<\/sup>Ir brachytherapy sources. Med Phys 2020; 47(11): 5838\u20135851.","DOI":"10.1002\/mp.14488"},{"key":"20","doi-asserted-by":"crossref","unstructured":"20\uff09\u2003Perez-Calatayud J, Ballester F, Das RK, et al. Dose calculation for photon-emitting brachytherapy sources with average energy higher than 50\u2009keV: report of the AAPM and ESTRO. Med Phys 2012; 39(5): 2904\u20132929.","DOI":"10.1118\/1.3703892"},{"key":"21","doi-asserted-by":"crossref","unstructured":"21\uff09\u2003Famulari G, Renaud MA, Poole CM, et al. RapidBrachyMCTPS: a Monte Carlo-based treatment planning system for brachytherapy applications. Phys Med Biol 2018; 63(17): 175007.","DOI":"10.1088\/1361-6560\/aad97a"},{"key":"22","doi-asserted-by":"crossref","unstructured":"22\uff09\u2003Abe K, Kadoya N, Sato S, et al. Impact of a commercially available model-based dose calculation algorithm on treatment planning of high-dose-rate brachytherapy in patients with cervical cancer. J Radiat Res 2018; 59(2): 198\u2013206.","DOI":"10.1093\/jrr\/rrx081"},{"key":"23","doi-asserted-by":"crossref","unstructured":"23\uff09\u2003Beaulieu L, Carlsson Tedgren A, Carrier JFS, et al. Report of the Task Group 186 on model-based dose calculation methods in brachytherapy beyond the TG-43 formalism: current status and recommendations for clinical implementation. Med Phys 2012; 39(10): 6208\u20136236.","DOI":"10.1118\/1.4747264"}],"container-title":["Japanese Journal of Radiological Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jjrt\/79\/7\/79_2023-1375\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,13]],"date-time":"2024-05-13T04:36:59Z","timestamp":1715575019000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jjrt\/79\/7\/79_2023-1375\/_article\/-char\/ja\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023]]},"references-count":23,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.6009\/jjrt.2023-1375","relation":{},"ISSN":["0369-4305","1881-4883"],"issn-type":[{"value":"0369-4305","type":"print"},{"value":"1881-4883","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023]]},"article-number":"2023-1375"}}